Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Toward new engagement paradigms for intraocular lenses: Light-initiated bonding of capsular bag to lens materials

  • Marcos, Susana
  • Alejandre, Nicolás
  • Lamela, Jorge
  • Dorronsoro, Carlos
  • Kochevar, I.E.
8 págs.; 5 figs., © 2015 The Association for Research in Vision and Ophthalmology, Inc. PURPOSE. Successful intraocular lens procedures, that is, implantation of accommodating intraocular lenses (A-IOL), require firm engagement of the IOL haptics to the capsular bag. We evaluated the use of photochemical bonding to engage IOL materials to the capsular bag. METHODS. Freshly enucleated eyes of New Zealand rabbits were used in two types of photobonding experiments using Rose Bengal (RB) photoinitiation and green light (532-nm) irradiation. First, RB-stained capsular bag strips were photobonded ex vivo to IOL polymer [poly(2-hydroxyethyl methacrylate) pHEMA] strips in an atmosphere of air and of nitrogen. Second, IOLs were implanted intracapsularly and photobonded intraocularly. Irradiation times were between 30 and 180 seconds, and laser irradiance was between 0.25 and 0.65 W/cm2. The strength of the bonding was tested using a custom-developed uniaxial extensiometry system and the breakage load (the load that caused breakage per bonded area) was calculated. RESULTS. The breakage load of ex vivo capsule–pHEMA bonds increased exponentially with irradiation time, using 0.45 W/cm2. In air, the average breakage load across all conditions was 1 g/mm2 and 1.6 times lower than that in a nitrogen atmosphere. Intraocularly, RB-stained IOLs were strongly photobonded to the capsule bag with breakage loads > 0.8 g/mm2. CONCLUSIONS. Breakage of the photobonded linkage between IOL material and capsular bag required loads substantially greater than the maximum force of ciliary muscle, suggesting that this technology may introduce a new paradigm for engagement of A-IOLs. The bonding produced in air was stronger than that in nitrogen atmosphere, suggesting that oxygen is involved in the chemical mechanism for photobonding., Supported by European Research Council (ERC) EU Seventh Framework Program (FP/2007-2013)/ERC grant agreement, ERC- 2011-AdC 294099 (SM), Spanish Government Grants FIS2011- 25637 (SM) and FIS2013-49544-EXP (CD), and Juan de la Cierva postdoctoral fellowship (JL)., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Material properties from air puff corneal deformation by numerical simulations on model corneas

  • Bekesi, Nandor
  • Dorronsoro, Carlos
  • Hoz, A. de la
  • Marcos, Susana
19 págs.; 11 figs.; 2 tabs., Objective To validate a new method for reconstructing corneal biomechanical properties from air puff corneal deformation images using hydrogel polymer model corneas and porcine corneas. Methods Air puff deformation imaging was performed on model eyes with artificial corneas made out of three different hydrogel materials with three different thicknesses and on porcine eyes, at constant intraocular pressure of 15 mmHg. The cornea air puff deformation was modeled using finite elements, and hyperelastic material parameters were determined through inverse modeling, minimizing the difference between the simulated and the measured central deformation amplitude and central-peripheral deformation ratio parameters. Uniaxial tensile tests were performed on the model cornea materials as well as on corneal strips, and the results were compared to stress-strain simulations assuming the reconstructed material parameters. Results The measured and simulated spatial and temporal profiles of the air puff deformation tests were in good agreement (< 7% average discrepancy). The simulated stress-strain curves of the studied hydrogel corneal materials fitted well the experimental stress-strain curves from uniaxial extensiometry, particularly in the 0-0.4 range. Equivalent Young?s moduli of the reconstructed material properties from air-puff were 0.31, 0.58 and 0.48 MPa for the three polymer materials respectively which differed < 1% from those obtained from extensiometry. The simulations of the same material but different thickness resulted in similar reconstructed material properties. The air-puff reconstructed average equivalent Young?s modulus of the porcine corneas was 1.3 MPa, within 18% of that obtained from extensiometry. Conclusions Air puff corneal deformation imaging with inverse finite element modeling can retrieve material properties of model hydrogel polymer corneas and real corneas, which are in good correspondence with those obtained from uniaxial extensiometry, suggesting that this is a promising technique to retrieve quantitative corneal biomechanical properties., This work was supported by the European Research Council under the European Union’s Seventh Framework Program ERC Advanced Grant agreement no. 294099 (erc.europa.eu) to SM; Comunidad de Madrid and EU Marie Curie COFUND program (FP7) 291820 (mvisionconsortium.org/) to NB; Ministerio de Economia y Competitividad Grant FIS2014-56643-R (www.mineco.gob.es) to SM; Ministerio de Economia y Competitividad Grant FIS2013-49544-EXP (www.mineco.gob.es) to CD; Ministerio de Economia y Competitividad FPI Fellowship BES-2015-072197 (www.idi.mineco.gob.es) to AdlH., Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Intraocular photobonding to enable accommodating intraocular lens function

  • Alejandre, Nicolás
  • Gutierrez-Contreras, R.
  • Dorronsoro, Carlos
  • Marcos, Susana
9 pags., 4 figs., Purpose: Accommodating intraocular lenses (A-IOLs) require capturing the ciliary muscle forces. Prior work demonstrated strong photo-initiated bonding between strips of capsular bag and poly(2-hydroxyethyl methacrylate); (pHEMA) polymer in an extraocular setting. We demonstrate that photobonding can be achieved intraocularly. Methods: Phacoemulsification was performed in porcine eyes (<24 hours postmortem). A commercial intraocular lens (IOL; pHEMA-MMA material) was inserted in the capsular bag. Surface contact between the lens and capsular bag was ensured by continuous air infusion into the anterior chamber of the eye, which provided sufficient pressure at the interface, as well as oxygen. The capsular bag and IOL then were stained with 0.1% photosensitizer Rose Bengal (RB) solution. A fiberoptic probe connected to a diode-laser (532 nm) was used to locally irradiate the capsular bag–IOL interface intraocularly. The bonding breaking load was evaluated in a uniaxial stretcher. Results: Photobonding occurred in the 0.8 to 1.6 W/cm irradiance range and 2.5 to 7 minutes irradiation time. Average forces of 0.12 N stretched but did not break the bond. These forces, applied uniaxially, are higher than the summed net accommodating force of the ciliary muscle along the entire equator (0.08 N). In two cases, the zonulae broke before the bonded region. Conclusions: Photobonding between the capsular bag and IOL polymer can be achieved intraocularly, in a procedure compatible with standard cataract surgery. This technique will enable the mechanisms of A-IOLs not to rely on capsular bag integrity or natural haptic fibrosis. Translational Relevance: Intraocular photobonding holds promise to enable operation of A-IOLs to restore accommodation in presbyopia, affecting 100% of the population <45 years old. Intraocular bonding of polymer material to ocular tissue also may find other applications in ophthalmology., This study was funded by the European Research Council under the European Union’s Seventh Framework Programme (FP7/2007-2013)/ERC Grant Agreement ERC-2011-AdG-294099 to SM. The current study was also supported by the Spanish government grants FIS2014-56643-R and FIS2017-84753-R to SM; and the FIS2013-49544-EXP to CD. The authors want to thank the Surface Spectroscopies & Surface Plasmon Photonics Group (Instituto de Estructura de la Materia, CSIC) for technical assistance.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Fluorescence Depth Measurements of Rose Bengal Diffused into Cornea and pHEMA measured by Two-photon Fluorescence Microscopy

  • Germann, James
  • Gutierrez-Contreras, R.
  • Dorronsoro, Carlos
  • Kochevar, Irene E.
  • Marcos, Susana
This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017., Support ERC-2011-AdG-294099, FIS2014-56643, FIS2013-49544-EXP, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Contribución de congreso (ConferenceOutput)

Intraocular photobonding for accommodating intraocular lenses

  • Gutierrez-Contreras, R.
  • Alejandre, Nicolás
  • Dorronsoro, Carlos
  • Marcos, Susana
This is an abstract that was submitted for the 2017 ARVO Annual Meeting, held in Baltimore, MD, May 7-11, 2017., Support European Research Conuncil ERC-2011-AdG-294099; Spanish Government FIS2014-56643R and FIS2013-49544-EXP, Peer reviewed