Pasar al contenido principal

SISTEMAS OPTICOS AVANZADOS DE MODULACION ESPECTRAL Y DE POLARIZACION -APLICACION EN DERMATOSCOPIA

FIS2015-66328-C3-3-R

•
Nombre agencia financiadora Ministerio de Economía y Competitividad
Acrónimo agencia financiadora MINECO
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2015
Plan Estatal 2013-2016 Plan Estatal de Investigación Científica y Técnica y de Innovación
Unidad de gestión Dirección General de Investigación Científica y Técnica
Centro beneficiario UNIVERSIDAD MIGUEL HERNANDEZ DE ELCHE
Identificador persistente http://dx.doi.org/10.13039/501100003329

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Depolarizing metrics for plant samples imaging

  • van Eeckhout, Albert
  • Garcia-Caurel, Enric
  • Garnatje, Teresa
  • Durfort, Mercè
  • Escalera, Juan Carlos
  • Vidal, Josep
  • Gil, José L.
  • Campos, Juan
  • Lizana, Ángel
Optical methods, as fluorescence microscopy or hyperspectral imaging, are commonly used for plants visualization and characterization. Another powerful collection of optical techniques is the so-called polarimetry, widely used to enhance image contrast in multiple applications. In the botanical applications framework, in spite of some works have already highlighted the depolarizing print that plant structures left on input polarized beams, the potential of polarimetric methods has not been properly exploited. In fact, among the few works dealing with polarization and plants, most of them study light scattered by plants using the Degree of Polarization (DoP) indicator. Other more powerful depolarization metrics are nowadays neglected. In this context, we highlight the potential of different depolarization metrics obtained using the Mueller matrix (MM) measurement: the Depolarization Index and the Indices of Polarimetric Purity. We perform a qualitative and quantitative comparison between DoP- and MM-based images by studying a particular plant, the Hedera maroccana. We show how Mueller-based metrics are generally more suitable in terms of contrast than DoP-based measurements. The potential of polarimetric measurements in the study of plants is highlighted in this work, suggesting they can be applied to the characterization of plants, plant taxonomy, water stress in plants, and other botanical studies., This research was supported by the Spanish MINECO (FIS2015-66328-C3-1-R, FIS2015-66328-C3-3-R and fondos FEDER, all to JC); Catalan Government (SGR 2014-1639 to JC)., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Depolarizing metrics for plant samples imaging

  • Van Eeckhout, A.
  • Garcia-Caurel, E.
  • Garnatje, T.
  • Durfort, M.
  • Escalera, J.C.
  • Vidal, J.
  • Gil, J.J.
  • Campos, J.
  • Lizana, A.
Optical methods, as fluorescence microscopy or hyperspectral imaging, are commonly used for plants visualization and characterization. Another powerful collection of optical techniques is the so-called polarimetry, widely used to enhance image contrast in multiple applications. In the botanical applications framework, in spite of some works have already highlighted the depolarizing print that plant structures left on input polarized beams, the potential of polarimetric methods has not been properly exploited. In fact, among the few works dealing with polarization and plants, most of them study light scattered by plants using the Degree of Polarization (DoP) indicator. Other more powerful depolarization metrics are nowadays neglected. In this context, we highlight the potential of different depolarization metrics obtained using the Mueller matrix (MM) measurement: the Depolarization Index and the Indices of Polarimetric Purity. We perform a qualitative and quantitative comparison between DoP- and MM-based images by studying a particular plant, the Hedera maroccana. We show how Mueller-based metrics are generally more suitable in terms of contrast than DoP-based measurements. The potential of polarimetric measurements in the study of plants is highlighted in this work, suggesting they can be applied to the characterization of plants, plant taxonomy, water stress in plants, and other botanical studies.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Polarization gating based on Mueller matrices

  • Lizana, Angel|||0000-0002-4861-8657
  • Van Eeckhout, Albert|||0000-0003-2540-2746
  • Adamczyk, Kamil
  • Rodríguez Mangues, Carla
  • Escalera Merino, Juan Carlos|||0000-0003-4618-627X
  • Garcia-Caurel, Enric
  • Moreno, Ignacio|||0000-0002-1550-0601
  • Campos Coloma, Juan|||0000-0002-2479-4373
We present mathematical formulas generalizing polarization gating (PG) techniques. PG refers to a collection of imaging methods based on the combination of different controlled polarization channels. In particular, we show how using the measured Mueller matrix (MM) of a sample, a widespread number of PG configurations can be evaluated just from analytical expressions based on the MM coefficients. We also show the interest of controlling the helicity of the states of polarization used for PG-based metrology, as this parameter has an impact in the image contrast of samples. In addition, we highlight the interest of combining PG techniques with tools of data analysis related to the MM formalism, such as the well-known MM decompositions. The method discussed in this work is illustrated with the results of polarimetric measurements done on artificial phantoms and real ex-vivo tissues.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Polarimetric imaging of biological tissues based on the indices of polarimetric purity

  • Van Eeckhout, Albert|||0000-0003-2540-2746
  • Lizana, Angel|||0000-0002-4861-8657
  • Garcia-Caurel, Enric
  • Gil Pérez, José Jorge|||0000-0003-1740-2244
  • Sansa, Adrià
  • Rodríguez Mangues, Carla
  • Estévez, Irene|||0000-0003-3693-8335
  • González, Emilio
  • Escalera Merino, Juan Carlos|||0000-0003-4618-627X
  • Moreno, Ignacio|||0000-0002-1550-0601
  • Campos Coloma, Juan|||0000-0002-2479-4373
We highlight the interest of using the indices of polarimetric purity (IPPs) to the inspection of biological tissues. The IPPs were recently proposed in the literature and they result in a further synthetization of the depolarizing properties of samples. Compared with standard polarimetric images of biological samples, IPP-based images lead to larger image contrast of some biological structures and to a further physical interpretation of the depolarizing mechanisms inherent to the samples. In addition, unlike other methods, their calculation do not require advanced algebraic operations (as is the case of polar decompositions), and they result in 3 indicators of easy implementation. We also propose a pseudo-colored encoding of the IPP information that leads to an improved visualization of samples. This last technique opens the possibility of tailored adjustment of tissues contrast by using customized pseudo-colored images. The potential of the IPP approach is experimentally highlighted along the manuscript by studying 3 different ex-vivo samples. A significant image contrast enhancement is obtained by using the IPP-based methods, compared to standard polarimetric images.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Indices of polarimetric purity to enhance the image quality in biophotonics applications

  • Van Eeckhout, Albert|||0000-0003-2540-2746
  • Lizana, Angel|||0000-0002-4861-8657
  • Garcia-Caurel, Enric
  • Gil, José J.
  • Sansa, Adrià
  • Rodríguez Mangues, Carla
  • Estévez, Irene|||0000-0003-3693-8335
  • González, Emilio
  • Zhang, Haolin
  • Escalera Merino, Juan Carlos|||0000-0003-4618-627X
  • Ossikovski, Razvigor
  • Moreno, Ignacio|||0000-0002-1550-0601
  • Campos Coloma, Juan|||0000-0002-2479-4373
Recently, a set of polarimetric indicators, the Indices of Polarimetric Purity (IPPs), were described in the literature. These indicators allow synthesize depolarization content of samples, and provide further analysis of depolarizers than other existing polarimetric indicators. We demonstrate the potential of the IPPs as a criterion to characterize and classify depolarizing samples. In particular, the method is firstly analyzed through a series of basic polarization experiments, and we prove how differences in the depolarizing capability of samples, concealed from the commonly used depolarization index P∆, are identified with the IPPs. In the second part of this work, the method is experimentally highlighted by studying a rabbit leg ex-vivo sample. The obtained images of the ex-vivo sample illustrate how IPPs provide a significant enhancement in the image contrast of some biological tissues and, in some cases, present new information hidden in the usual polarimetric channels. Moreover, new physical interpretation of the sample can be derived from the IPPs which allow us to synthesize the depolarization behavior. Finally, we also propose a pseudo-colored encoding of the IPPs information that provides an improved visualization of the samples. This last technique opens the possibility to highlight a specific tissue structure by properly adjusting the pseudo-colored formula.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Dual polarization split lenses

  • Cofré, Aarón|||0000-0001-5916-3902
  • Vargas, Asticio|||0000-0002-2364-2351
  • Torres Ruiz, Fabian A.|||0000-0001-9952-7002
  • Campos Coloma, Juan|||0000-0002-2479-4373
  • Lizana, Angel|||0000-0002-4861-8657
  • Sánchez López, María del Mar
  • Moreno, Ignacio|||0000-0002-1550-0601
We report the realization of polarization sensitive split lens configurations. While split lenses can be used to easily generate different types of controlled structured light patterns, their realization has been limited so far to scalar beams. Here we propose and experimentally demonstrate their generalization to vectorial split lenses, leading to light patterns with customized intensity and state of polarization. We demonstrate how these polarization split lenses can be experimentally implemented by means of an optical system using two liquid crystal spatial light modulators, each one phase modulating one orthogonal polarization component. As a result, we demonstrate the experimental generation of vectorial beams with different shapes generated with these dual polarization split lenses. Excellent experimental results are provided in each case. The proposed technique is a simple method to generate structured light beams with polarization diversity, with potential applications in polarimetry, customized illuminators or quantum optics.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Depolarizing metrics for plant samples imaging

  • Van Eeckhout, Albert|||0000-0003-2540-2746
  • Garcia-Caurel, Enric
  • Garnatje, Teresa|||0000-0001-6295-6217
  • Durfort, Mercè
  • Escalera Merino, Juan Carlos|||0000-0003-4618-627X
  • Vidal, Josep
  • Gil Pérez, José Jorge|||0000-0003-1740-2244
  • Campos Coloma, Juan|||0000-0002-2479-4373
  • Lizana, Angel|||0000-0002-4861-8657
Optical methods, as fluorescence microscopy or hyperspectral imaging, are commonly used for plants visualization and characterization. Another powerful collection of optical techniques is the so-called polarimetry, widely used to enhance image contrast in multiple applications. In the botanical applications framework, in spite of some works have already highlighted the depolarizing print that plant structures left on input polarized beams, the potential of polarimetric methods has not been properly exploited. In fact, among the few works dealing with polarization and plants, most of them study light scattered by plants using the Degree of Polarization (DoP) indicator. Other more powerful depolarization metrics are nowadays neglected. In this context, we highlight the potential of different depolarization metrics obtained using the Mueller matrix (MM) measurement: the Depolarization Index and the Indices of Polarimetric Purity. We perform a qualitative and quantitative comparison between DoP- and MM-based images by studying a particular plant, the Hedera maroccana. We show how Mueller-based metrics are generally more suitable in terms of contrast than DoP-based measurements. The potential of polarimetric measurements in the study of plants is highlighted in this work, suggesting they can be applied to the characterization of plants, plant taxonomy, water stress in plants, and other botanical studies.