Robustness of steel truss bridges: laboratory testing of a full-scale 21-metre bridge span

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Calderón García, Pedro Antonio|||0000-0002-9783-9333
  • Adam, Jose M|||0000-0002-9205-8458
  • Bertolesi, Elisa
[EN] This study aimed to experimentally analyse the robustness of riveted steel bridges based on truss-type structures and to define practical recommendations for early detection of local failures before they cause progressive structural collapse. Although there are many experimental studies on robustness and progressive collapse on buildings, those on bridges are either theoretical or deal with actual collapses. This paper describes a unique case of a 21m full-scale bridge span tested under laboratory conditions with an extensive monitoring system, together with an experimental study to evaluate structural behaviour and robustness as damage or failure progressed in its elements. A linear-static finite-element analysis was also included to examine other possible causes not included in the experiment. The results proved the structural redundancy of this type of truss structure based on the joints¿ resistance to bending moments and gave rise to a series of practical structural health recommendations to identify early failures and avoid progressive or sudden bridge collapse. The study carried out and the recommendations it produced are now being applied in three similar bridge case studies., We would like to express our gratitude to the FGV (Ferrocarrils de la Generalitat Valenciana) and FCC Construcción S.A., CHM Obras e Infraestructuras S.A., Contratas y Ventas S.A. and CALSENS S.L. for giving us the opportunity to test a bridge at the ICITECH facilities, also to Juan Antonio García Cerezo, of FGV, for his invaluable cooperation and recommendations. We also wish to show our gratitude for the magnificent work on the bridge by Jesús Martínez, Eduardo Luengo and Daniel Tasquer. The tests on the bridge meant that much of the Structures Laboratory was out of service for other work, for which we owe a debt of gratitude to our ICITECH colleagues for their infinite patience and understanding.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Robustness of RC building structures with infill masonry walls: tests on a purpose-built structure

  • Buitrago, Manuel|||0000-0002-5561-5104
  • Calderón García, Pedro Antonio|||0000-0002-9783-9333
  • Adam, Jose M|||0000-0002-9205-8458
  • Bertolesi, Elisa
  • Juan Sagaseta
[EN] Structural robustness is a significant property towards improving resilience of buildings, i.e. enhance their ability to withstand and recover from extreme events which often can cause local damage and progressive collapse. It is widely accepted that robustness depends on the capacity of the structure to activate alternative load paths (ALPs) after the failure of load-bearing elements, e.g. columns. Early evidence during World War II showed that progressive collapse of some buildings was avoided by the presence of masonry infill walls. Subsequent studies focused on this effect for cases of sudden column removal although most of these studies were analytical, numerical and only looked at internal columns which are generally less vulnerable to accidental events compared to corner and edge columns. The aim of this study was to analyse how infill walls can improve the robustness of reinforced concrete (RC) buildings in corner columns failure scenarios. A purpose-built 3D two-storey full-scale RC building structure with infill masonry walls was tested. The contribution of masonry infill walls was analysed in terms of: i) load redistribution, ii) ALPs, and iii) Dynamic Amplification Factors (DAFs) to be applied in linear-static analyses. The test was highly monitored by 38 strain gauges, 38 LVDTs and 2 accelerometers to register the vertical and lateral response. The results showed that masonry infill walls had a significant influence on the structural response and activated the predominant ALPs at very small deflections., This work was carried out with the support of a 2017 Leonardo Grant for Researchers and Cultural Creators from the BBVA Foundation. The authors would also like to express their gratitude to the Levantina, Ingenieria y Construccion S.L. (LIC) company for funding the construction of the building, and to the Generalitat Valenciana/Fons Social Europeu [APOSTD/2019/101] and Universitat Politecnica de Valencia [PAID-10-17] for funding received under different postdoctoral programs.