Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 8
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Response of parylene-coated NaI(Tl) scintillators at low temperature

  • Coron, N.
  • Cuesta, C.
  • García, E.
  • Ginestra, C.
  • Girard, T.A.
  • De Marcillac, P.
  • Martínez, M.
  • Ortigoza, Y.
  • De Solórzano, A.O.
  • Pobes, C.
  • Puimedón, J.
  • Redon, T.
  • Sarsa, M.L.
  • Torres, L.
  • Valko, P.
  • Villar, J.A.
Despite that it is widely used as a scintillator at room temperature, the hygroscopicity of NaI complicates its handling and limits its application for many purposes, for example as a cryogenic detector. To overcome this problem we study coating materials that can act as humidity barriers, in particular parylene, a polymer that can be deposited in very radiopure, thin and conformal layers. In this work, several NaI(Tl) samples coated with 2-5 µm parylene-C were tested at low temperature. Luminescence spectra under X-ray excitation are presented at several temperatures as well as the light output vs temperature at 1.5-300 K. Several thermoluminescence peaks were observed at around 60, 95 and 150 K during warm up to room temperature The mechanical resistance of the coating under thermal cycles was also investigated, and we observed a degradation of the optical appearance and the light output after cooling down to about 100 mK, which compromises the reusability of the samples.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Neutron Spectrometry with Scintillating Bolometers of LiF and Sapphire

  • Coron, N.
  • Cuesta, C.
  • Garcia, E.
  • Ginestra, C.
  • Gironnet, J.
  • De Marcillac, P.
  • Martinez, M.
  • Ortigoza, Y.
  • Ortiz de Solorzano, A./Puimedon, J.
  • Redon, T.
  • Rolon, T.
  • Sarsa, M.L.
  • Torres, L.
  • Villar, J.A.
Two scintillating bolometers of LiF (33 g) and Al2O3 (50 g) at 20 mK, inside a lead shielding at the Canfranc Underground Laboratory, were irradiated with neutrons from a source of 252Cf. The analysis of nuclear recoils registered by sapphire and (n, a) captures by 6Li shows the feasibility of these cryogenic devices to measure the spectral flux of a neutron field. Data unfolding was done assuming that the spectral flux is a piecewise constant function defined on six energy groups. It can be solved by using non-negative least squares without additional assumptions on the neutron flux. The model provides consistent results with the spectra of the observed events in bolometers, giving a fast neutron flux of F(E > 0.1 MeV) = 0.20 n s-1cm-2 with a 15% uncertainty after 3 hours of live time. After our analysis, it can be concluded that nuclear recoils in sapphire are more useful than (n, a) captures in LiF for spectrometry of fast neutrons.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Slow scintillation time constants in NaI(Tl) for different interacting particles

  • Cuesta, C.
  • Oliván, M.A.
  • Amaré, J.
  • Cebrián, S.
  • García, E.
  • Ginestra, C.
  • Martínez, M.
  • Ortigoza, Y.
  • Ortiz de Solórzano, A.
  • Pobes, C.
  • Puimedón, J.
  • Sarsa, M.L.
  • Villar, J.A.
  • Villar, P.
Very large thallium doped sodium iodide crystals operated underground and in very low background environment in the context of a dark matter search experiment have been used to determine scintillation components in the tens of ms range in the light pulse induced by different interacting particles: γ/μ and α.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Preliminary results of ANAIS-25

  • Amaré, J.
  • Cebrián, S.
  • Cuesta, C.
  • García, E.
  • Ginestra, C.
  • Martínez, M.
  • Oliván, M.A.
  • Ortigoza, Y.
  • Ortiz de Solórzano, A.
  • Pobes, C.
  • Puimedón, J.
  • Sarsa, M.L.
  • Villar, J.A.
  • Villar, P.
The ANAIS (Annual Modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory. 250 kg of ultrapure NaI(Tl) crystals will be used as a target, divided into 20 modules, each coupled to two photomultipliers. Two NaI(Tl) crystals of 12.5 kg each, grown by Alpha Spectra from a powder having a potassium level under the limit of our analytical techniques, form the ANAIS-25 set-up. The background contributions are being carefully studied and preliminary results are presented: their natural potassium content in the bulk has been quantified, as well as the uranium and thorium radioactive chains presence in the bulk through the discrimination of the corresponding alpha events by PSA, and due to the fast commissioning, the contribution from cosmogenic activated isotopes is clearly identified and their decay observed along the first months of data taking. Following the procedures established with ANAIS-0 and previous prototypes, bulk NaI(Tl) scintillation events selection and light collection efficiency have been also studied in ANAIS-25.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Annual modulation results from three-year exposure of ANAIS-112

  • Amaré, J.
  • Cebrián, S.
  • Cintas, D.
  • Coarasa, I.
  • García, E.
  • Martínez, M.
  • Oliván, M.A.
  • Ortigoza, Y.
  • Ortiz de Solórzano, A.
  • Puimedón, J.
  • Salinas, A.
  • Sarsa, M.L.
  • Villar, P.
ANAIS (annual modulation with NaI scintillators) is a dark matter direct detection experiment consisting of 112.5 kg of NaI(Tl) detectors in operation at the Canfranc Underground Laboratory (LSC), in Spain, since August 2017. ANAIS’ goal is to confirm or refute in a model independent way the DAMA/LIBRA positive result: an annual modulation in the low-energy detection rate having all the features expected for the signal induced by dark matter particles in a standard galactic halo. This modulation, observed for about 20 years, is in strong tension with the negative results of other very sensitive experiments, but a model-independent comparison is still lacking. By using the same target material, NaI(Tl), such a comparison is more direct and almost independent in dark matter particle and halo models. Here, we present the annual modulation analysis corresponding to three years of ANAIS data (for an effective exposure of 313.95 kg×y), applying a blind procedure, which updates the one developed for the 1.5 years analysis, and later applied to 2 years. The analysis also improves the background modeling in the fitting of the region of interest rates. We obtain for the best fit in the [1–6] keV ([2–6] keV) energy region a modulation amplitude of –0.0034±0.0042 cpd/kg/keV (0.0003±0.0037 cpd/kg/keV), supporting the absence of modulation in our data, and incompatible with the DAMA/LIBRA result at 3.3 (2.6) σ , for a sensitivity of 2.5 (2.7) σ . Moreover, we include two complementary analyses: a phase-free annual modulation search and the exploration of the possible presence of a periodic signal at other frequencies. Finally, we carry out several consistency checks of our result, and we update the ANAIS-112 projected sensitivity for the scheduled 5 years of operation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Dark Matter Annual Modulation Results from the ANAIS-112 Experiment

  • Amaré, Julio
  • Cebrián, Susana
  • Cintas, David
  • Coarasa, Iván
  • García, Eduardo
  • Martínez, María
  • Oliván, Miguel
  • Ortigoza, Ysrael
  • Ortiz de Solórzano, Alfonso
  • Puimedón, Jorge
  • Salinas, Ana
  • Sarsa, María
  • Villar, Patricia
An annual modulation in the interaction rate of galactic dark matter particles is foreseen due to Earth’s movement around the Sun; the DAMA/LIBRA observation of a modulation signal compatible with expectations has intrigued the community for twenty years. The ANAIS-112 experiment, with a target of 112.5 kg of NaI(Tl), has been running smoothly at the Canfranc Underground Laboratory (Spain) since 2017. It aims to test this observation using the same detection technique and target. Results on the modulation search from two years of data (220.7 kg·y) have been presented and the analysis of three years (313.6 kg·y) is underway. Under the hypothesis of modulation, the deduced amplitudes from best fits are in all cases compatible with zero for the two energy regions at [2–6] and [1–6] keV; the results agree with the expected sensitivity for the considered exposure and fully support the goal of achieving a 3σ sensitivity to explore the DAMA/LIBRA result for a five-year operation. Here, the ANAIS-112 set-up and performance will be briefly recapped and the annual modulation results and prospects will be discussed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Machine-learning techniques applied to three-year exposure of ANAIS–112

  • Coarasa, I.
  • Apilluelo, J.
  • Amaré, J.
  • Cebrián, S.
  • Cintas, D.
  • García, E.
  • Martínez, M.
  • Oliván, M. A.
  • Ortigoza, Y.
  • Ortiz de Solórzano, A.
  • Puimedón, J.
  • Salinas, A.
  • Sarsa, M. L.
  • Villar, P.
ANAIS is a direct dark matter detection experiment aiming at the confirmation or refutation of the DAMA/LIBRA positive annual modulation signal in the low energy detection rate, using the same target and technique. ANAIS–112, located at the Canfranc Underground Laboratory in Spain, is operating an array of 3×3 ultrapure NaI(Tl) crystals with a total mass of 112.5 kg since August 2017. The trigger rate in the region of interest (1-6 keV) is dominated by non-bulk scintillation events. In order to discriminate these noise events from bulk scintillation events, robust filtering protocols have been developed. Although this filtering procedure works very well above 2 keV, the measured rate from 1 to 2 keV is about 50% higher than expected according to our background model, and we cannot discard non-bulk scintillation events as responsible of that excess. In order to improve the rejection of noise events, a Boosted Decision Tree has been developed and applied. With this new PMT-related noise rejection algorithm, the ANAIS–112 background between 1 and 2 keV is reduced by almost 30%, leading to an increase in sensitivity to the annual modulation signal. The reanalysis of the three years of ANAIS–112 data with this technique is also presented.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Toward a clinical practice guide in pharmacogenomics testing for functional polymorphisms of drug-metabolizing enzymes. Gene/drug pairs and barriers perceived in Spain

  • Agúndez, J. A. G.
  • Abad-Santos, F.
  • Aldea, A.
  • Alonso-Navarro, H.
  • Bernal, M. L.
  • Borobia, A. M.
  • Borrás, E.
  • Carballo, M.
  • Carvajal, A.
  • García-Muñiz, J. D.
  • Gervasini,G.
  • Jiménez-Jiménez,F. J.
  • Lucena,M. I.
  • Martínez,C.
  • Sacristán,J. A.
  • Salado,I.
  • Sinués,B.
  • Vicente,J.
  • García-Martín,E.
The development of clinical practice recommendation sor guide lines forthe clinical use of biomarkersis an issue of great importance with regard to averse drug reactions. Thepoten-tial of pharmacogenomic biomarkers has been extensively investigate dinrecent years. However, several barriers to implementing the use of pharmacogenomics testing exist. We conducted asurvey among members of the Spanish Societies of Pharmacology and Clinical Pharmacology to obtain in format in about the perception of uch barrier sand to compare the perceptions of participants about the relative importance of ma jorgene/drug pairs. Of 11 potential barriers, the highest importance was attributed to lack of institutional support for pharmacogenomics testing, and to the issues related to the lackof guidelines. Of the proposed gene/drug pairs the highest importance was as signed to HLA-B/abacavir, UGT1A1/irinotecan, andCYP2D6/tamoxifen. In this perspective article, we compare there lative importanceof 29 gene /drug pairs in the Spanish study witht hat of the same pair sinthe American Society for Clinical Pharmacology and Therapeutics study, and we provide suggestions and area soffocus to developaguide for clinical practice in pharmacogenomics testing.