Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Fault relay zones evolving through distributed longitudinal fractures: The case of the Teruel graben system (Iberian Chain, Spain)

  • Peiro, Alba
  • Simón, José Luis
  • Román-Berdiel, Teresa
A new type of fault relay zone in extensional contexts, dominated by distributed along-strike or longitudinal fractures, is defined. It contrasts with the classical models reported in the literature, in which transverse connecting faults controlled by the own relay kinematics prevail. The new model is based on structural features of the Teruel graben system, as well as on analogue modelling. Relay zones between the NW-SE to NNW-SSE striking faults that delimit the eastern boundary of the Jiloca Graben (Calamocha, Sierra Palomera and Concud faults), together with the Teruel Fault, have been studied. All of these relay faults show recent (Neogene-Quaternary) ruptures at different scales, mostly parallel to the macrostructural trend and to the maximum horizontal stress (S<inf>Hmax</inf>) trajectories (i.e., orthogonal to the ENE-WSW regional extension direction that characterises the nearly biaxial or radial stress regime active during Upper Pliocene-Quaternary times). Transverse ruptures are almost absent, with the exception of the northern relay zone (Calamocha-Sierra Palomera), where an incipient NE-SW striking connecting fault does exist. Analogue models have been run under a biaxial extension regime similar to the regional one. They allowed analysing the main factors controlling fracture propagation, depending on the ratio of extension velocities and the orientation of the master faults relative to extension directions. Laboratory fracture patterns, as in the natural studied examples, are mostly controlled by the inherited anisotropies and, in a greater extent, by the imposed extension trajectories, which results in a clear prevalence of longitudinal fractures. Such external controls, usually disregarded in numerical and analogue modelling, tend to induce fault coalescence through along-strike (parallel or at very-low-angle) propagation resulting in a final braided fault pattern.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Frasnian–Famennian (Upper Devonian) conodont biofacies and global events in the compte section (Central Pyrenees, Spain)

  • Barrera-Lahoz, Héctor
  • Valenzuela-Ríos, José Ignacio
  • Liao, Jau-Chyn
Detailed studies on conodont biofacies from upper Frasnian to middle Famennian in the Compte section (Central Pyrenees area) allow recognition of different eustatic fluctuations and the Kellwasser, Nehden, and Condroz events. Five conodont biofacies have been identified: Palmatolepis, Palmatolepis–Polygnathus, Polygnathus–Palmatolepis, Palmatolepis–Icriodus and the new Icriodus–Palmatolepis biofacies. The evolution of conodont biofacies during the end Frasnian reflects a sudden regressive episode at the base of FZ13b subzone and a maximum transgressive trend at the top of FZ13b subzone, which aligns with the Upper Kellwasser Event. The Kellwasser crisis dramatically reduces the conodont biodiversity, which recovers during the lower Famennian. A transgressive trend is recorded during the Palmatolepis crepida–Palmatolepis gl. prima zone interval, which may be referred to as the Nehden Event. Within La Mena Formation two regressive trends are identified by sharp conodont biofacies changes in the Palmatolepis rhomboidea and Palmatolepis gr. gracilis zones: the lower and upper Condroz Events.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

El controvertido complejo conglomerático de Sierra Pelarda (Cordillera Ibérica central): el reciclado de clastos en un modelo integral morfo-tecto-sedimentario

  • Simón Gómez, José Luis
  • Arlegui Crespo, Luis E.
  • Luzón Aguado, Aránzazu
  • Peiro Chamarro, Alba
  • Soriano Jiménez, Mª Asunción
  • Liesa Carrera, Carlos L.
El complejo conglomerático de la Sierra Pelarda (Cordillera Ibérica central) ha sido objeto de controversia debido a la disparidad de interpretaciones sobre su origen y edad. Este trabajo presenta un modelo morfo-tecto-sedimentario integral que demuestra que la presencia ubicua de cantos silíceos es resultado de la herencia litológica y el reciclado continuo de clastos a lo largo del Cenozoico. El grueso de los depósitos, denominado Conjunto 1 (C1), es una potente serie inclinada del Eoceno medio-superior, correspondiente a la UTS T2 de la Cuenca de Montalbán. Los conjuntos posteriores (C2, C3, C4) son depósitos neógeno-cuaternarios derivados de la erosión de C1. La parte alta de la sierra es un relieve residual que no quedó arrasado por la Superficie de Erosión Fundamental (SEF) y fue sobreelevado por la falla de Cucalón-Pancrudo, la mayor estructura extensional en la Cordillera Ibérica centro-oriental. Esta falla representa la inversión negativa de una estructura transpresiva previa y ha desplazado la superficie de aplanamiento SEF3 unos 280-300 m (salto neto de 305-325 m) en los últimos 3,5 Ma. Estos resultados corroboran la hipótesis de una edad paleógena para el complejo conglomerático original, planteada en los primeros trabajos, y refutan el modelo de una gran unidad aluvial plio-cuaternaria.