Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cosmogenic production of tritium in dark matter detectors

  • Amaré, J.
  • Castel, J.
  • Cebrián, S.
  • Coarasa, I.
  • Cuesta, C.
  • Dafni, T.
  • Galán, J.
  • García, E.
  • Garza, J.G.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Luzón, G.
  • Martínez, M.
  • Mirallas, H.
  • Oliván, M.A.
  • Ortigoza, Y.
  • Ortiz de Solórzano, A.
  • Puimedón, J.
  • Ruiz-Chóliz, E.
  • Sarsa, M.L.
  • Villar, J.A.
  • Villar, P.
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and long half-life) when induced in the detector medium, and because it can be generated in any material as a spallation product. Quantification of cosmogenic production of tritium is not straightforward, neither experimentally nor by calculations. In this work, a method for the calculation of production rates at sea level has been developed and applied to some of the materials typically used as targets in dark matter detectors (germanium, sodium iodide, argon and neon); it is based on a selected description of tritium production cross sections over the entire energy range of cosmic nucleons. Results have been compared to available data in the literature, either based on other calculations or from measurements. The obtained tritium production rates, ranging from a few tens to a few hundreds of nuclei per kg and per day at sea level, point to a significant contribution to the background in dark matter experiments, requiring the application of specific protocols for target material purification, material storing underground and limiting the time the detector is on surface during the building process in order to minimize the exposure to the most dangerous cosmic ray components.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Performance of ANAIS-112 experiment after the first year of data taking

  • Amaré, J.
  • Cebrián, S.
  • Coarasa, I.
  • Cuesta, C.
  • García, E.
  • Martínez, M.
  • Oliván, M.A.
  • Ortigoza, Y.
  • de Solórzano, A.O.
  • Puimedón, J.
  • Salinas, A.
  • Sarsa, M.L.
  • Villar, P.
  • Villar, J.A.
ANAIS is a direct detection dark matter experiment aiming at the study of the annual modulation expected in the interaction rate. It uses same target and technique as the DAMA/LIBRA experiment, which reported a highly significant positive modulation compatible with that expected for dark matter particles distributed in the galactic halo. However, other very sensitive experiments do not find any hint of particles with the required properties, although comparison is model dependent. In 2017, ANAIS-112 experiment was installed at the Canfranc Underground Laboratory (LSC), in Spain, and after the commissioning run for calibration and general assessment, ANAIS-112 started data taking in dark matter mode on August 3rd, 2017. It consists of nine NaI(Tl) modules, amounting 112.5 kg of mass in total. Here we report on the experimental apparatus and detector performance after the first year of data taking. Total live time available amounts to 341.72 days, being the corresponding exposure 105.32 kg × year. ANAIS-112 has achieved an analysis energy threshold of 1 keVee and an average background in the region of interest, from 1 to 6 keVee, of 3.6 counts/keVee/kg/day after correcting by the event selection efficiencies. In these conditions, ANAIS-112 will be able to test the DAMA/LIBRA result at three sigma level in five years of data taking.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

ANAIS-112 sensitivity in the search for dark matter annual modulation

  • Coarasa, I.
  • Amaré, J.
  • Cebrián, S.
  • Cuesta, C.
  • García, E.
  • Martínez, M.
  • Oliván, M.A.
  • Ortigoza, Y.
  • de Solórzano, A.O.
  • Puimedón, J.
  • Salinas, A.
  • Sarsa, M.L.
  • Villar, P.
  • Villar, J.A.
The annual modulation measured by the DAMA/LIBRA experiment can be explained by the interaction of dark matter WIMPs in NaI(Tl) scintillator detectors. Other experiments, with different targets or techniques, exclude the region of parameters singled out by DAMA/LIBRA, but the comparison of their results relies on several hypotheses regarding the dark matter model. ANAIS-112 is a dark matter search with 112.5 kg of NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC) to test the DAMA/LIBRA result in a model independent way. We analyze its prospects in terms of the a priori critical and detection limits of the experiment. A simple figure of merit has been obtained to compare the different experiments looking for the annual modulation observed by DAMA/LIBRA. We conclude that after 5 years of measurement, ANAIS-112 can detect the annual modulation in the 3 s region compatible with the DAMA/LIBRA result.