Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 42
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Description and commissioning of NEXT-MM prototype: first results from operation in a Xenon-Trimethylamine gas mixture

  • Alvarez, V.
  • Aznar, F.
  • Borges, F. I. G. M.
  • Calvet, D.
  • Carcel, S.
  • Castel, J.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Dafni, T.
  • Dias, T. H. V. T.
  • Diaz, J.
  • Druillole, F.
  • Egorov, M.
  • Evtoukhovitch, P.
  • Fernandes, L. M. P.
  • Ferrario, P.
  • Ferreira, A. L.
  • Ferrer-Ribas, E.
  • Freitas, E. D. C.
  • Gehman, V. M.
  • Gil, A.
  • Giomataris, I.
  • Goldschmidt, A.
  • Gomez, H.
  • Gomez-Cadenas, J. J.
  • Gonzalez-Diaz, D.
  • Gutierrez, R. M.
  • Hauptman, J.
  • Hernando Morata, J. A.
  • Herrera, D. C.
  • Iguaz, F. J.
  • Irastorza, I. G.
  • Jinete, M. A.
  • Labarga, L.
  • Laing, A.
  • Le Coguie, A.
  • Liubarsky, I.
  • Lopes, J. A. M.
  • Lorca, D.
  • Losada, M.
  • Luzon, G.
  • Marí Romero, Antonio Francisco
  • Martin-Albo, J.
  • Martinez, A.
  • Martinez-Lema, G.
  • Miller, T.
  • Moiseenko, A.
  • Mols, J. P.
  • Monrabal, F.
  • Monteiro, C. M. B.
  • Moutinho, L. M.
  • Munoz Vidal, J.
  • Natal da Luz, H.
  • Navarro, G.
  • Nebot Guinot, M.
  • Nigren, D.
  • Oliveira, C.A.B.
  • Palma, R.
  • Perez, J.
  • Pérez Aparicio, José Luis
  • Renner, J.
  • Ripoll, L.
  • Rodriguez, A.
  • Rodriguez, J.
  • Santos, F. P.
  • dos Santos, J. M. F.
  • Segui, L.
  • Serra, L.
  • Shuman, D.
  • Simon, A.
  • Sofka, C.
  • Sorel, M.
  • Tomas, A.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J. F. C. A.
  • Villar, J.A.
  • Webb, R. C.
  • White, J. T.
  • Yahlali, N.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] A technical description of NEXT-MM and its commissioning and first performance is reported. Having an active volume of ∼35 cm drift × 28 cm diameter, it constitutes the largest Micromegas-read TPC operated in Xenon ever constructed, made by a sectorial arrangement of the 4 largest single wafers manufactured with the Microbulk technique to date. It is equipped with a suitably pixelized readout and with a sufficiently large sensitive volume (∼23 l) so as to contain long (∼20 cm) electron tracks. First results obtained at 1 bar for Xenon and Trymethylamine (Xe-(2%)TMA) mixture are presented. The TPC can accurately reconstruct extended background tracks. An encouraging full-width half-maximum of 11.6 % was obtained for ∼29 keV gammas without resorting to any data post-processing., The NEXT Collaboration acknowledges funding support from the following agencies and institutions: the Spanish Ministerio de Economia y Competitividad under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), Consolider-Ingenio 2010 CSD2007- 00042 (CPAN), and under contracts ref. FPA2008-03456, FPA2009-13697-C04-04; FCT(Lisbon) and FEDER under grant PTDC/FIS/103860/2008; the European Commission under the European Research Council T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231. Part of these grants are funded by the European Regional Development Fund (ERDF/FEDER). J. Renner (LBNL) acknowledges the support of a US DOE NNSA Stewardship Science Graduate Fellowship under contract no. DE-FC52-08NA28752. F.I. acknowledges the support from the Eurotalents program. We are also grateful to our colleagues of the RD-51 collaboration for helpful discussions and encouragement. Finally, authors would like to acknowledge the use of Servicio General de Apoyo a la Investigacion-SAI of the Universidad de Zaragoza and R. de Oliveira and his team at CERN for the manufacturing of the Micromegas readouts.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

NEXT-100 Technical Design Report (TDR). Executive summary

  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Catalá Civera, José Manuel|||0000-0002-0617-1762
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Monzó Ferrer, José María|||0000-0001-6554-3231
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Borges, F.I.G.M.
  • Cárcel García, Sara
  • Carmona, J. M.
  • Castel, J.
  • Cebrián, S.
  • Marí Romero, Antonio Francisco
  • Palma Guerrero, Roberto
  • Pérez Aparicio, José Luis
[EN] In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (ßß0v) in 136XE at the Laboratorio Subterráneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while keeping the operating pressure at a manageable level. The readout plane performing the energy measurement is composed of Hamamatsu R11410-10 photomultipliers, specially designed for operation in low-background, xenon-based detectors. Each individual PMT will be isolated from the gas by an individual, pressure resistant enclosure and will be coupled to the sensitive volume through a sapphire window. The tracking plane consists in an array of Hamamatsu S10362-11-050P MPPCs used as tracking pixels. They will be arranged in square boards holding 64 sensors (8 x 8) with a 1-cm pitch. The inner walls of the TPC, the sapphire windows and the boards holding the MPPCs will be coated with tetraphenyl butadiene (TPB), a wavelength shifter, to improve the light collection. © 2012 IOP Publishing Ltd and Sissa Medialab srl., The NEXT Collaboration acknowledges support from the following agencies and institutions: the Spanish Ministerio de Economia y Competitividad under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04 and RYC-2008-03169; the Portuguese Foundation for Science and Technology under grant PTDC/FIS/112272/2009 ("High Pressure Xenon Doped Mixtures for NEXT Collaboration"); the European Commission under the European Research Council Starting Grant ERC-2009-StG-240054 (T-REX) of the IDEAS program of the 7th EU Framework Program; and the Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231. J. Renner (LBNL) acknowledges the support of a US DOE NNSA Stewardship Science Graduate Fellowship under contract no. DE-FC52-08NA28752.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy gamma-rays

  • Álvarez, V.
  • Borges, F.I.G.M.
  • Cárcel, S.
  • Castel, J.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Dafni, T.
  • Dias, T.H.V.T.
  • Díaz, J.
  • Egorov, M.
  • Evtoukhovitch, P.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Gil, A.
  • Goldschmidt, A.
  • Gómez, H.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D.C.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jinete, M.A.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lopes, J.A.M.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí Romero, Antonio Francisco
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • Miller, T.
  • Moiseenko, A.
  • Monrabal, F.
  • Monteiro C.M.B.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Natal da Luz, H.
  • Navarro, G.
  • Nebot-Guinot, D.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Palma, R.
  • Pérez, J.
  • Pérez Aparicio, José Luis
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, A.
  • Rodríguez, J.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Segui, L.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Tomás, A.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Vázquez, D.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.C.
  • White, J.T.
  • Yahlali, N.
  • Aznar, F.
  • Calvet, D.
  • Druillole, F.
  • Ferrer-Ribas, E.
  • García, J.A.
  • Giomataris, I.
  • Gracia, J.
  • Le Coguie, A.
  • Mols, J.P.
  • Pons, P.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Ruiz, E.
[EN] NEXT-MM is a general-purpose high pressure (10 bar, ∼25 l active volume) Xenon- based TPC, read out in charge mode with an 0.8 cm×0.8 cm-segmented 700 cm2 plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT 0νββ experiment, although the experiment s first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy γ -rays emitted by a 241 Am source when interacting with the Xenon gas (Eγ = 26, 30, 59.5 keV). The localized nature of such events above atmospheric pressure, the long drift times, as well as the possibility to determine their production time from the associated α particle in coincidence, allow the extraction of primordial properties of the TPC filling gas, namely the drift velocity, diffusion and attachment coefficients. In this work we focus on the little explored combination of Xe and trimethylamine (TMA) for which, in particular, such properties are largely unknown. This gas mixture offers potential advantages over pure Xenon when aimed at Rare Event Searches, mainly due to its Penning characteristics, wave-length shifting properties and reduced diffusion, and it is being actively investigated by our collaboration. The chamber is currently operated at 2.7 bar, as an intermediate step towards the envisaged 10 bar. We report here its performance as well as a first implementation of the calibration procedures that have allowed the extension of the previously reported energy resolution to the whole readout plane (10.6% FWHM@30 keV), NEXT is supported by the following agencies and institutions: the Ministerio de Econom´ıa y Competitividad (MINECO) of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04 and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02- 05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009. J. Renner (LBNL) acknowledges the support of a US DOE NNSA Stewardship Science Graduate Fellowship under contract no. DE-FC52- 08NA28752. The development of NEXT-MM in particular has important contributions from the European Research Council T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; and also MINECO under grants FPA2008-03456, FPA2011-24058 and CPAN under grant CSD2007- 00042. This work would not have been possible without the encouragement of our RD51 colleages and the dedicated effort of R. de Oliveira and his team at CERN to provide these unique detectors. Discussions with O. Sahin, R. Veenhof, S. Biagi and C. Acevedo are greatly acknowledged. DGD gratefully acknowledges the ‘Charpak award’ for this work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment

  • Cebrian, S.
  • Perez, J.
  • Bandac, I.
  • Labarga, L.
  • Alvarez, V.
  • Barrado, A. I.
  • Bettini, A.
  • Borges, F. I. G. M.
  • Camargo, M.
  • Carcel, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Conde, E.
  • Dafni, T Diaz, J.
  • Fernandes, L. M. P.
  • Fernandez, M.
  • Ferrario, P.
  • Ferreira, A. L.
  • Freitas, E. D. C.
  • Gehman, V. M.
  • Goldschmidt, A.
  • Gomez-Cadenas, J. J.
  • Gonzalez-Diaz, D.
  • Gutierrez, R. M.
  • Hauptman, J.
  • Hernando Morata, J. A.
  • Herrera, D. C.
  • Irastorza, I. G.
  • Laing, A.
  • Liubarsky, I.
  • Lopez-March, N.
  • Lorca, D.
  • Losada, M.
  • Luzon, G.
  • Marí Peláez, Antonio
  • Martin-Albo, J.
  • Martinez, A.
  • Martinez-Lema, G.
  • Miller, T.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C. M. B.
  • Moutinho, L. M.
  • Munoz Vidal, J.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C. A. B.
  • Ortiz de Solorzano, A.
  • Pérez Aparicio, José Luis
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodriguez, J.
  • Santos, F. P.
  • dos Santos, J. M. F.
  • Serra, L.
  • Shuman, D.
  • Simon, A.
  • Sofka, C.
  • Sorel, M.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J. F. C. A.
  • Villar, J. A.
  • Webb, R. C.
  • White, J. T.
  • Yahlali, N.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radio-purity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radio pure tracking plane, in direct contact with the gas detector medium, was a challenge since the needed components have typically activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper and silicon photomultipliers., We deeply acknowledge John Murphy and Carl Jackson from SensL Technologies Ltd for their efficient collaboration in the analysis of SiPMs. We very much thank also Vicenzo Mancini from SOMACIS company for the care in the development of radiopure kapton PCBs. Special thanks are due to LSC directorate and staff for their strong support for performing the measurements at the LSC Radiopurity Service. The NEXT Collaboration acknowledges funding support from the following agencies and institutions: the European Research Council under the Advanced Grant 339787-NEXT and the T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; the Spanish Ministerio de Economia y Competitividad under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04, and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences of the US DoE under Contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, Projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements

  • Alvarez, V.
  • Bandac, I.
  • Bettini, A.
  • Borges, F. I. G. M.
  • Carcel, S.
  • Castel, J.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Dafni, T.
  • Marí Romero, Antonio Francisco
  • Palma, R.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Pérez Aparicio, José Luis
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The "Neutrino Experiment with a Xenon Time-Projection Chamber" (NEXT) is intended to investigate the neutrinoless double beta decay of Xe-136, which requires a severe suppression of potential backgrounds. An extensive screening and material selection process is underway for NEXT since the control of the radiopurity levels of the materials to be used in the experimental set-up is a must for rare event searches. First measurements based on Glow Discharge Mass Spectrometry and gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) are described here. Activity results for natural radioactive chains and other common radionuclides are summarized, being the values obtained for some materials like copper and stainless steel very competitive. The implications of these results for the NEXT experiment are also discussed., We deeply acknowledge LSC directorate and staff for their strong support for performing the measurements at the LSC Radiopurity Service. The NEXT Collaboration acknowledges funding support from the following agencies and institutions: the Spanish Ministerio de Economia y Competitividad under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), Consolider-Ingenio 2010 CSD2007-00042 (CPAN), and under contracts ref. FPA2008-03456, FPA2009-13697-C04-04; FCT(Lisbon) and FEDER under grant PTDC/FIS/103860/2008; the European Commission under the European Research Council T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231. Part of these grants are funded by the European Regional Development Fund (ERDF/FEDER). J. Renner (LBNL) acknowledges the support of a US DOE NNSA Stewardship Science Graduate Fellowship under contract no. DE-FC52-08NA28752. F.I. acknowledges the support from the Eurotalents program.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm

  • Gonzalez Diaz, Diego
  • Borges, F. I. G.
  • Camargo, M.
  • Carcel, S.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Dafni, T.
  • Fernandes, L. M. P.
  • Pérez Aparicio, José Luis
  • Rodríguez Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in similar to 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +/- 0.13 mm-sigma (longitudinal), 0.95 +/- 0.20 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent' mixture. The TPC, that houses 1.1 kg of gas in its fiducial volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8 mm x 8 mm x 1.2 mm for approximately 10 cm/MeV-long electron tracks. Resolution in energy (epsilon) at full width half maximum (R) inside the fiducial volume ranged from R = 14.6% (30 keV) to R = 4.6% (1.275 MeV). This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the neutrino-less double beta decay (beta beta 0 nu) in Xe-136, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks. In particular, the obtained energy resolution has been decomposed in its various contributions and improvements towards achieving the R =1.4%root MeV/epsilon levels obtained in small sensors are discussed, The NEXT collaboration acknowledges funding support from the following agencies and institutions: European Research Council under Advanced Grant 339787-NEXT and Starting Grant 240054-TREX, Spanish Ministerio de Economia y Competitividad under grants Consolider-Ingenio 2010 CSD2008-0037 (CUP) and CSD2007-00042 (CPAN), contracts FPA2008-03456 and FPA2009-13697; Portuguese Fundacao para a Ciencia e a Tecnologia; European FEDER under grant PPTDC/FIS/103860/2008; US Department Of Energy under contract DE-AC02-05CH11231.
Biblos-e Archivo. Repositorio Institucional de la UAM
Publicación Artículo científico (JournalArticle)

Radon and material radiopurity assessment for the NEXT double beta decay experiment

  • Cebrián, S.
  • Pérez, J.
  • Labarga Echeverría, Luis Alfonso
Artículo escrito por un elevado número de autores, solo se referencian el que aparece en primer lugar, el nombre del grupo de colaboración, si le hubiere, y los autores pertenecientes a la UAM, The ”Neutrino Experiment with a Xenon TPC” (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low backgroundgermanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too, The NEXT Collaboration acknowledges funding support from the following agencies and institutions: the European Research Council under the Advanced Grant 339787-NEXT and the T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; the Spanish Ministerio de Economía y Competitividad under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04, and FIS2012-37947- C04; the Director, Office of Science, Office of Basic Energy Sciences of the US DoE under Contract no. DE-AC02- 05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, Projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009. S. Cebrián acknowledges the support from the University of Zaragoza (Convocatoria propia de proyectos de investigación para Jóvenes Investigadores 2014). Special thanks are due to LSC directorate and staff for their strong support for performing the measurements at the LSC Radiopurity Service
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Axion searches with microwave filters: The RADES project

  • Álvarez Melcón, Alejandro
  • Arguedas Cuendis, Sergio
  • Cogollos, Cristian
  • Díaz-Morcillo, Alejandro
  • Döbrich, Babette
  • Gallego, Juan Daniel
  • Gimeno, Benito
  • Irastorza, Igor G.
  • Lozano-Guerrero, Antonio José
  • Malbrunot, Chloé
  • Navarro, Pablo
  • Peña-Garay, Carlos
  • Redondo, Javier
  • Vafeiadis, Theodoros
  • Wuensch, Walter
We propose, design and construct a variant of the conventional axion haloscope concept that could be competitive in the search for dark matter axions of masses in the decade 10–100 μeV. Theses masses are located somewhat above the mass range in which existing experiments have reached sensitivity to benchmark QCD axion models. Our haloscope consists of an array of small microwave cavities connected by rectangular irises, in an arrangement commonly used in radio-frequency filters. The size of the unit cavity determines the main resonant frequency, while the possibility to connect a large number of cavities allows to reach large detection volumes. We develop the theoretical framework of the detection concept, and present design prescriptions to optimize detection capabilities. We describe the design and realization of a first small-scale prototype of this concept, called Relic Axion Detector Exploratory Setup (RADES). It consists of a copper-coated stainless steel five-cavities microwave filter with the detecting mode operating at around 8.4 GHz. This structure has been electromagnetically characterized at 2 K and 298 K, and it is now placed in ultra-high vacuum in one of the twin-bores of the 9 T CAST dipole magnet at CERN. We describe the data acquisition system developed for relic axion detection, and present preliminary results of the electromagnetic properties of the microwave filter, which show the potential of filters to reach QCD axion window sensitivity at X-band frequencies., This work has been funded by the Spanish Agencia Estatal de Investigacion (AEI) and Fondo Europeo de Desarrollo Regional (FEDER) under project FPA-2016-76978, and Fundacion Seneca Ref. 20147/EE/17, and was supported by the CERN Doctoral Studentship programme. IGI acknowledges also support from the European Research Council (ERC) under grant ERC-2009-StG-240054 (T-REX project). JR is supported by the Ramon y Cajal Fellowship 2012-10597, the grant FPA2015-65745-P (MINECO/FEDER), the EU through the ITN “Elusives” H2020-MSCA-ITN-2015/674896 and the Deutsche Forschungsgemeinschaft under grant SFB-1258 as a Mercator Fellow. CPG was supported by PROMETEO II/2014/050 of Generalitat Valenciana, FPA2014-57816-P of MINECO and by the European Union’s Horizon 2020 research and innovation program under the Marie Sklodowska-Curie grant agreements 690575 and 674896., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Search for solar axions by the CERN axion solar telescope with He 3 buffer gas: Closing the hot dark matter gap

  • Arik, M.
  • Aune, S.
  • Barth, K.
  • Belov, A.
  • Borghi, S.
  • Bräuninger, H.
  • Cantatore, G.
  • Carmona, J.M.
  • Cetin, S.A.
  • Collar, J.I.
  • Da Riva, E.
  • Dafni, T.
  • Davenport, M.
  • Eleftheriadis, C.
  • Elias, N.
  • Fanourakis, G.
  • Ferrer-Ribas, E.
  • Friedrich, P.
  • Galán, J.
  • García, J.A.
  • Gardikiotis, A.
  • Garza, J.G.
  • Gazis, E.N.
  • Geralis, T.
  • Georgiopoulou, E.
  • Giomataris, I.
  • Gninenko, S.
  • Gómez, H.
  • Gómez Marzoa, M.
  • Gruber, E.
  • Guthörl, T.
  • Hartmann, R.
  • Hauf, S.
  • Haug, F.
  • Hasinoff, M.D.
  • Hoffmann, D.H.H.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jacoby, J.
  • Jakovcic, K.
  • Karuza, M.
  • Königsmann, K.
  • Kotthaus, R.
  • Krcmar, M.
  • Kuster, M.
  • Lakic, B.
  • Lang, P.M.
  • Laurent, J.M.
  • Liolios, A.
  • Ljubicic, A.
  • Luzón, G.
  • Neff, S.
  • Niinikoski, T.
  • Nordt, A.
  • Papaevangelou, T.
  • Pivovaroff, M.J.
  • Raffelt, G.
  • Riege, H.
  • Rodríguez, A.
  • Rosu, M.
  • Ruz, J.
  • Savvidis, I.
  • Shilon, I.
  • Silva, P.S.
  • Solanki, S.K.
  • Stewart, L.
  • Tomás, A.
  • Tsagri, M.
  • Van Bibber, K.
  • Vafeiadis, T.
  • Villar, J.
  • Vogel, J.K.
  • Yildiz, S.C.
  • Zioutas, K.
The CERN Axion Solar Telescope has finished its search for solar axions with 3He buffer gas, covering the search range 0.64  eV≲ma≲1.17  eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess x rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of gaγ≲3.3×10−10  GeV−1 at 95% C.L., with the exact value depending on the pressure setting. Future direct solar axion searches will focus on increasing the sensitivity to smaller values of gaγ, for example by the currently discussed next generation helioscope International AXion Observatory.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

TREX-DM: a low background Micromegas-based TPC for low mass WIMP detection

  • Iguaz, F.J.
  • Garza, J.G.
  • Aznar, F.
  • Castel, J.F.
  • Cebrián, S.
  • Dafni, T.
  • García, J.A.
  • Gómez, H.
  • González-Diaz, D.
  • Irastorza, I.G.
  • Lagraba, A.
  • Luzón, G.
  • Peiró, A.
  • Rodríguez, A.
Dark Matter experiments are recently focusing their detection techniques in low- mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we present the TREX-DM experiment, a low background Micromegas-based TPC for low-mass WIMP detection. Its main goal is the operation of an active detection mass ~0.300 kg, with an energy threshold below 0.4 keVee and fully built with previously selected radiopure materials. This article describes the actual setup, the first results of the comissioning in Ar+2%iC4H10 at 1.2 bar and the future updates for a possible physics run at the Canfranc Underground Laboratory in 2016. A first background model is also presented, based on Geant4 simulations and a muon/electron discrimination method. In a conservative scenario, TREX-DM could be sensitive to DAMA/LIBRA and other hints of positive WIMPs signals, with some space for improvement with a neutron/electron discrimination method or the use of other light gases.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy gamma-rays

  • Álvarez, V.
  • Borges, F.I.G.M.
  • Cárcel, S.
  • Castel, J.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Dafni, T.
  • Dias, T.H.V.T.
  • Díaz, J.
  • Egorov, M.
  • Esteve R.
  • Evtoukhovitch, P.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Gil, A.
  • Goldschmidt, A.
  • Gómez, H.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D.C.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jinete, M.A.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lopes, J.A.M.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí, A.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • Miller, T.
  • Moiseenko, A.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Natalda Luz, H.
  • Navarro, G.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Palma, R.
  • Pérez, J.
  • Pérez Aparicio, J.L.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, A.
  • Rodríguez, J.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Segui, L.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Tomás, A.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Vázquez, D.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.C.
  • White, J.T.
  • Yahlali, N.
  • Aznar, F.
  • Calvet, D.
  • Druillole, F.
  • Ferrer-Ribas, E.
  • García, J.A.
  • Giomataris, I.
  • Gracia, J.
  • Le Coguie, A.
  • Mols, J.P.
  • Pons, P.
  • Ruiz, E.
NEXT-MM is a general-purpose high pressure (10 bar, 25 l active volume) Xenonbased TPC, read out in charge mode with an 0:8 cm 0:8 cm-segmented 700 cm2 plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT 0nbb experiment, although the experiment’s first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy g- rays emitted by a 241Am source when interacting with the Xenon gas (Eg = 26, 30, 59:5 keV). The localized nature of such events around atmospheric pressure, the long drift times, as well as the possibility to determine their production time from the associated a particle in coincidence, allow the extraction of primordial properties of the TPC filling gas, namely the drift velocity, diffusion and attachment coefficients. In this work we focus on the little explored combination of Xe and trimethylamine (TMA) for which, in particular, such properties are largely unknown. This gas mixture offers potential advantages over pure Xenon when aimed at Rare Event Searches, mainly 2014 JINST 9 C04015 due to its Penning characteristics, wave-length shifting properties and reduced diffusion, and it is being actively investigated by our collaboration. The chamber is currently operated at 2.7 bar, as an intermediate step towards the envisaged 10 bar. We report here its performance as well as a first implementation of the calibration procedures that have allowed the extension of the previously reported energy resolution to the whole readout plane
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

New solar axion search using the CERN Axion Solar Telescope with He4 filling

  • Arik, M.
  • Aune, S.
  • Barth, K.
  • Belov, A.
  • Bräuninger, H.
  • Bremer, J.
  • Burwitz, V.
  • Cantatore, G.
  • Carmona, J.M.
  • Cetin, S.A.
  • Collar, J.I.
  • Da Riva, E.
  • Dafni, T.
  • Davenport, M.
  • Dermenev, A.
  • Eleftheriadis, C.
  • Elias, N.
  • Fanourakis, G.
  • Ferrer-Ribas, E.
  • Galván, J.
  • García, J.A.
  • Gardikiotis, A.
  • Garza, J.G.
  • Gazis, E.N.
  • Geralis, T.
  • Georgiopoulou, E.
  • Giomataris, I.
  • Gninenko, S.
  • Gómez Marzoa, M.
  • Hasinoff, M.D.
  • Hoffmann, D.H.H.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jacoby, J.
  • Jakovcic, K.
  • Karuza, M.
  • Kavuk, M.
  • Krcmar, M.
  • Kuster, M.
  • Lakic, B.
  • Laurent, J.M.
  • Liolios, A.
  • Ljubicic, A.
  • Luzón, G.
  • Neff, S.
  • Niinikoski, T.
  • Nordt, A.
  • Ortega, I.
  • Papaevangelou, T.
  • Pivovaroff, M.J.
  • Raffelt, G.
  • Rodríguez, A.
  • Rosu, M.
  • Ruz, J.
  • Savvidis, I.
  • Shilon, I.
  • Solanki, S.K.
  • Stewart, L.
  • Tomás, A.
  • Vafeiadis, T.
  • Villar, J.
  • Vogel, J.K.
  • Yildiz, S.C.
  • Zioutas, K.
The CERN Axion Solar Telescope (CAST) searches for a --> conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. Two parallel magnet bores can be filled with helium of adjustable pressure to match the x-ray refractive mass m-a to the axion search mass ma. After the vacuum phase (2003–2004), which is optimal for ma <0.02 eV, we used 4He in 2005–2007 to cover the mass range of 0.02–0.39 eV and 3He in 2009–2011 to scan from 0.39 to 1.17 eV. After improving thedetectors and shielding, we returned to 4He in 2012 to investigate a narrow ma range around 0.2 eV (“candidate setting” of our earlier search) and 0.39–0.42 eV, the upper axion mass range reachable with 4He, to “cross the axion line” for the KSVZ model. We have improved the limit on the axion-photon coupling...
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Search for chameleons with CAST

  • Anastassopoulos, V.
  • Arik, M.
  • Aune, S.
  • Barth, K.
  • Belov, A.
  • Bräuninger, H.
  • Cantatore, G.
  • Carmona, J.M.
  • Cetin, S.A.
  • Christensen, F.
  • Collar, J.I.
  • Dafni, T.
  • Davenport, M.
  • Desch, K.
  • Dermenev, A.
  • Eleftheriadis, C.
  • Fanourakis, G.
  • Ferrer-Ribas, E.
  • Friedrich, P.
  • Galán, J.
  • García, J.A.
  • Gardikiotis, A.
  • Garza, J.G.
  • Gazis, E.N.
  • Geralis, T.
  • Giomataris, I.
  • Hailey, C.
  • Haug, F.
  • Hasinoff, M.D.
  • Hoffmann, D.H.H.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jacoby, J.
  • Jakobsen, A.
  • Jakovcic, K.
  • Kaminski, J.
  • Karuza, M.
  • Kavuk, M.
  • Krcmar, M.
  • Krieger, C.
  • Krüger, A.
  • Lakic, B.
  • Laurent, J.M.
  • Liolios, A.
  • Ljubicic, A.
  • Luzón, G.
  • Neff, S.
  • Ortega, I.
  • Papaevangelou, T.
  • Pivovaroff, M.J.
  • Raffelt, G.
  • Riege, H.
  • Rosu, M.
  • Ruz, J.
  • Savvidis, I.
  • Solanki, S.K.
  • Vafeiadis, T.
  • Villar, J.A.
  • Vogel, J.K.
  • Yildiz, S.C.
  • Zioutas, K.
  • Brax, P.
  • Lavrentyev, I.
  • Upadhye, A.
In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter (ßm) and to photons (ß¿) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1keV to 400eV CAST became sensitive to the converted solar chameleon spectrum which peaks around 600eV. Even though we have not observed any excess above background, we can provide a 95% C.L. limit for the coupling strength of chameleons to photons of ß¿¿1011 for 1<ßm<106.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Experimental Searches for the Axion and Axion-Like Particles

  • Graham, P.W.
  • Irastorza, I.G.
  • Lamoreaux, S.K.
  • Lindner, A.
  • Van Bibber, K.A.
Four decades after its prediction, the axion remains the most compelling solution to the strong-CP problem and a well-motivated dark matter candidate, inspiring a host of elegant and ultrasensitive experiments based on axion-photon mixing. This article reviews the experimental situation on several fronts. The microwave cavity experiment is making excellent progress in the search for dark matter axions in the µeV range and may plausibly be extended up to 100 µeV. Within the past several years, however, researchers have realized that axions are pervasive throughout string theories, but with masses that fall naturally in the neV range, for which an NMR-based search is under development. Both searches for axions emitted from the Sun's burning core and purely laboratory experiments based on photon regeneration have recently made great progress, with ambitious projects proposed for the coming decade. Each of these campaigns has pushed the state of the art in technology, enabling large gains in sensitivity and mass reach. Furthermore, each modality has been exploited in order to search for more generalized axion-like particles, which we also discuss in this review. We are hopeful, even optimistic, that the next review of the subject will concern the discovery of the axion, its properties, and its exploitation as a probe of early universe cosmology and structure formation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment

  • Cebrián, S.
  • Pérez, J.
  • Bandac, I.
  • Labarga, L.
  • Álvarez, V.
  • Barrado, A.I.
  • Bettini, A.
  • Borges, F.I.G.M.
  • Camargo, M.
  • Cárcel, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Conde, E.
  • Dafni, T.
  • Díaz, J.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Fernández, M.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Morata, J.A.H.
  • Herrera, D.C.
  • Irastorza, I.G.
  • Laing, A.
  • Liubarsky, I.
  • López-March, N.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí, A.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • Miller, T.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Vidal, J.M.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Ortiz de Solórzano, A.
  • Aparicio, J.L.P.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Santos, F.P.
  • Santos, J.M.F.D.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.C.
  • White, J.T.
  • Yahlali, N.
The ``Neutrino Experiment with a Xenon Time-Projection Chamber'' (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterr'aneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8×10-4 counts keV-1 kg-1 y-1, have been identified.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

TREX-DM: a low background Micromegas-based TPC for low-mass WIMP detection

  • Iguaz, F J
  • Garza, J G
  • Aznar, F
  • Castel, J F
  • Cebrián, S
  • Dafni, T
  • García, J A
  • Irastorza, I G
  • Lagraba, A
  • Luzón, G
  • Peiró, A
Dark Matter experiments are recently focusing their detection techniques in low- mass WIMPs, which requires the use of light elements and low energy threshold. In this context, we describe the TREX-DM experiment, a low background Micromegas-based TPC for low-mass WIMP detection. Its main goal is the operation of an active detection mass ~0.3 kg, with an energy threshold below 0.4 keVee and fully built with previously selected radiopure materials. This work describes the commissioning of the actual setup situated in a laboratory on surface and the updates needed for a possible physics run at the Canfranc Underground Laboratory (LSC) in 2016. A preliminary background model of TREX-DM is also presented, based on a Geant4 simulation, the simulation of the detector’s response and two discrimination methods: a conservative muon/electron and one based on a neutron source. Based on this background model, TREX-DM could be competitive in the search for low-mass WIMPs. In particular it could be sensitive, e.g., to the low-mass WIMP interpretation of the DAMA/LIBRA and other hints in a conservative scenario.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Lessons from the operation of the 'Penning-Fluorescent' TPC and prospects

  • Gonzalez-Diaz, Diego
  • Aznar, F.
  • Castel, J.
  • Cebrián, S.
  • Dafni, T.
  • García, J A.
  • Garza, J G.
  • Gómez, H.
  • Herrera, D C.
  • Iguaz, F J.
  • García Irastorza, I.
  • Lagraba, A.
  • Luzón, G.
  • Rodríguez, A.
  • Ruiz-Choliz, E.
  • Segui, L.
  • Tomás, A.
  • Ferrer-Ribas, E.
  • Giomataris, I.
We have recently reported the development of a new type of high-pressure Xenon time projection chamber operated with an ultra-low diffusion mixture and that simultaneously displays Penning effect and fluorescence in the near-visible region (300 nm). The concept, dubbed 'Penning-Fluorescent' TPC, allows the simultaneous reconstruction of primary charge and scintillation with high topological and calorimetric fidelity.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

TREX-DM: a low-background Micromegas-based TPC for low-mass WIMP detection

  • Iguaz, F.J.
  • Garza, J.G.
  • Aznar, F.
  • Castel, J.F.
  • Cebrián, S.
  • Dafni, T.
  • García, J.A.
  • Irastorza, I.G.
  • Lagraba, A.
  • Luzón, G.
  • Peiró, A.
If Dark Matter is made of Weakly Interacting Massive Particles (WIMPs) with masses below~20 GeV, the corresponding nuclear recoils in mainstream WIMP experiments are of energies too close, or below, the experimental threshold. Gas Time Projection Chambers (TPCs) can be operated with a variety of target elements, offer good tracking capabilities and, on account of the amplification in gas, very lowthresholds are achievable. Recent advances in electronics and in novel radiopure TPC readouts, especially micro-mesh gas structure (Micromegas), are improving the scalability and low-background prospects of gaseous TPCs. Here we present TREX-DM, a prototype to test the concept of a Micromegasbased TPC to search for low-mass WIMPs. The detector is designed to host an active mass of ~0.300 kg of Ar at 10 bar, or alternatively ~0.160 kg of Ne at 10 bar, with an energy threshold below 0.4 keVee, and is fully built with radiopure materials. We will describe the detector in detail, the results from the commissioning phase on surface, as well as a preliminary background model. The anticipated sensitivity of this technique may go beyond current experimental limits for WIMPs of masses of 2–8 GeV.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Modelling the behaviour of microbulk Micromegas in xenon/trimethylamine gas

  • Ruiz-Choliz, E.
  • González-Díaz, D.
  • Diago, A.
  • Castel, J.
  • Dafni, T.
  • Herrera, D.C.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Luzón, G.
  • Mirallas, H.
  • Sahin, O.
  • Veenhof, R.
We model the response of a state of the art micro-hole single-stage charge amplification device ('microbulk' Micromegas) in a gaseous atmosphere consisting of xenon/trimethylamine at various concentrations and pressures. The amplifying structure, made with photo-lithographic techniques similar to those followed in the fabrication of gas electron multipliers (GEMs), consisted of a 100 mu m-side equilateral-triangle pattern with 50 pm-diameter holes placed at its vertexes. Once the primary electrons are guided into the holes by virtue of an optimized field configuration, avalanches develop along the 50 [an-height channels etched out of the original doubly copper-clad polyimide foil. In order to properly account for the strong field gradients at the holes' entrance as well as for the fluctuations of the avalanche process (that ultimately determine the achievable energy resolution), we abandoned the hydrodynamic framework, resorting to a purely microscopic description of the electron trajectories as obtained from elementary cross-sections. We show that achieving a satisfactory description needs additional assumptions about atom-molecule (Penning) transfer reactions and charge recombination to be made.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research

  • Aznar, F.
  • Castel, J.
  • Christensen, F.E.
  • Dafni, T.
  • Decker, T.A.
  • Ferrer-Ribas, E.
  • Garcia, J.A.
  • Giomataris, I.
  • Garza, J.G.
  • Hailey, C.J.
  • Hill, R.M.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jakobsen, A.C.
  • Luzon, G.
  • Mirallas, H.
  • Papaevangelou, T.
  • Pivovaroff, M.J.
  • Ruz, J.
  • Vafeiadis, T.
  • Vogel, J.K.
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas detector of the microbulk technology. The detector is made from radiopure materials and is placed at the focal point of a similar to 5 cm diameter, 1.5 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) assembled from thermally-formed (or "slumped") glass substrates deposited with multilayer coatings. The system has been conceived as a technological pathfinder for the future International Axion Observatory (IAXO), as it combines two of the techniques (optic and detector) proposed in the conceptual design of the project. It is innovative for two reasons: it is the first time an x-ray optic has been designed and fabricated specifically for axion research, and the first time a Micromegas detector has been operated with an x-ray optic. The line has been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and is currently looking for solar axions. The combination of the XRT and Micromegas detector provides the best signal-to-noise ratio obtained so far by any detection system of the CAST experiment with a background rate of 5.4 x 10(-3) counts per hour in the energy region-of-interest and signal spot area.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The IAXO Helioscope

  • Ferrer Ribas, E.
  • Armengaud, E.
  • Avignone, F.T.
  • Betz, M.
  • Brax, P.
  • Brun, P.
  • Cantatore, G.
  • Carmona, J.M.
  • Carosi, G.P.
  • Caspers, F.
  • Caspi, S.
  • Cetin, S.A.
  • Chelouchem, D.
  • Christensen, F.E.
  • Dael, A.
  • Dafni, T.
  • Davenport, M.
  • Derbin, A.V.
  • Desch, K.
  • Diago, A.
  • Dobrich, B.
  • Dratchnev, I.
  • Dudarev, A.
  • Eleftheriadis, C.
  • Fanourakis, G.
  • Galan, J.
  • Garcia, J.A.
  • Garza, J.G.
  • Geralis, T.
  • Gimeno, B.
  • Giomatarisl, I.
  • Gninenko, S.
  • Gomez, H.
  • Gonzalez-Diaz, D.
  • Guendelman, E.
  • Hailey, C.J.
  • Hiramatsu, T.
  • Hoffmann, D.H.H.
  • Horns, D.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Isern, J.
  • Imai, K.
  • Jaeckel, J.
  • Jakobsen, A.C.
  • Jakovcic, K.
  • Kaminski, J.
  • Kawasaki, M.
  • Karuza, M.
  • Krcmar, M.
  • Kousouris, K.
  • Krieger, C.
  • Lakic, B.
  • Limousin, O.
  • Lindner, A.
  • Liolios, A.
  • Luzon, G.
  • Matsuki, S.
  • Muratova, V.N.
  • Nones, C.
  • Ortega, I.
  • Papaevangelou, T.
  • Pivovaroff, M.J.
  • Raffelt, G.
  • Redondo, J.
  • Ringwald, A.
  • Russenschuck, S.
  • Ruz, J.
  • Saikawa, K.
  • Savvidis, I.
  • Sekiguchi, T.
  • Semertzidis, Y.K.
  • Shilon, I.
  • Sikivie, P.
  • Silva, H.
  • ten Kate, H.H.J.
  • Tomas, A.
  • Troitsky, S.
  • Vafeiadis, T.
  • van Bibber, K.
  • Vedrine, P.
  • Villar, J.A.
  • Vogel, J.K.
  • Walckiers, L.
  • Weltman, A.
  • Wester, W.
  • Yildiz, S.C.
  • Zioutas, K.
The IAXO (International Axion Experiment) is a fourth generation helioscope with a sensitivity, in terms of detectable signal counts, at least 104 better than CAST phase-I, resulting in sensitivity on ga¿ one order of magnitude better. To achieve this performance IAXO will count on a 8-coil toroidal magnet with 60 cm diameter bores and equipped with X-ray focusing optics into 0.20 cm2 spots coupled to ultra-low background Micromegas X-ray detectors. The magnet will be on a platform that will allow solar tracking for 12 hours per day. The next short term objectives are to prepare a Technical Design Report and to construct the first prototypes of the hardware main ingredients: demonstration coil, X-ray optics and low background detector while refining the physics case and studying the feasibility studies for Dark Matter axions.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements

  • Álvarez, V.
  • Bandac, I.
  • Bettini, A.
  • Borges, F.I.G.M.
  • Cárcel, S.
  • Castel, J.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Dafni, T.
  • Dias, T.H.V.T.
  • Díaz, J.
  • Egorov, M.
  • Esteve, R.
  • Evtoukhovitch, P.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Gil, A.
  • Goldschmidt, A.
  • Gómez, H.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D.C.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jinete, M.A.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lopes, J.A.M.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • A.Marí, A.
  • Martín-Albo, J.
  • Martínez, A.
  • Miller, T.
  • Moiseenko, A.
  • Monrabal, A.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Natal da Luz, H.
  • Navarro, G.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Ortiz de Solórzano, A.
  • Palma, R.
  • Pérez, J.J.
  • Pérez Aparicio, J.L.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, A.
  • Rodríguez, J.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Segui, L.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Tomás, A.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Vázquez, D.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.C.
  • White, J.T.
  • Yahlali, N.
The “Neutrino Experiment with a Xenon Time-Projection Chamber” (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds. An extensive screening and material selection process is underway for NEXT since the control of the radiopurity levels of the materials to be used in the experimental set-up is a must for rare event searches. First measurements based on Glow Discharge Mass Spectrometry and gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterr´aneo de Canfranc (Spain) are described here. Activity results for natural radioactive chains and other common radionuclides are summarized, being the values obtained for some materials like copper and stainless steel very competitive. The implications of these results for the NEXT experiment are also discussed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

New CAST limit on the axion-photon interaction

  • Anastassopoulos, V.
  • Aune, S.
  • Barth, K.
  • Belov, A.
  • Bräuninger, H.
  • Cantatore, G.
  • Carmona, J.M.
  • Castel, J.F.
  • Cetin, S.A.
  • Christensen, F.
  • Collar, J.I.
  • Dafni, T.
  • Davenport, M.
  • Decker, T.A.
  • Dermenev, A.
  • Desch, K.
  • Eleftheriadis, C.
  • Fanourakis, G.
  • Ferrer-Ribas, E.
  • Fischer, H.
  • García, J.A.
  • Gardikiotis, A.
  • Garza, J.G.
  • Gazis, E.N.
  • Geralis, T.
  • Giomataris, I.
  • Gninenko, S.
  • Hailey, C.J.
  • Hasinoff, M.D.
  • Hoffmann, D.H.H.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jakobsen, A.
  • Jacoby, J.
  • Jakovcic, K.
  • Kaminski, J.
  • Karuza, M.
  • Kralj, N.
  • Krcmar, M.
  • Kostoglou, S.
  • Krieger , Ch.
  • Lakic, B.
  • Laurent, J.M.
  • Liolios, A.
  • Ljubicic, A.
  • Luzón, G.
  • Maroudas, M.
  • Miceli, L.
  • Neff, S.
  • Ortega, I.
  • Papaevangelou, T.
  • Paraschou, K.
  • Pivovaroff, M.J.
  • Raffelt, G.
  • Rosu, M.
  • Ruz, J.
  • Chóliz, E.R.
  • Savvidis, I.
  • Schmidt, S.
  • Semertzidis, Y.K.
  • Solanki, S.K.
  • Stewart, L.
  • Vafeiadis, T.
  • Vogel, J.K.
  • Yildiz, S.C.
  • Zioutas, K.
Hypothetical low-mass particles, such as axions, provide a compelling explanation for the dark matter in the universe. Such particles are expected to emerge abundantly from the hot interior of stars. To test this prediction, the CERN Axion Solar Telescope (CAST) uses a 9 T refurbished Large Hadron Collider test magnet directed towards the Sun. In the strong magnetic field, solar axions can be converted to X-ray photons which can be recorded by X-ray detectors. In the 2013-2015 run, thanks to low-background detectors and a new X-ray telescope, the signal-to-noise ratio was increased by about a factor of three. Here, we report the best limit on the axion-photon coupling strength (0.66 × 10 -10 GeV -1 at 95% confidence level) set by CAST, which now reaches similar levels to the most restrictive astrophysical bounds.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The potential of discrimination methods in a high pressure xenon TPC for the search of the neutrinoless double-beta decay of Xe-136

  • Iguaz, F.J.
  • Aznar, F.
  • Castel, J.F.
  • Cebrián, S.
  • Dafni, T.
  • Galán, J.
  • Garza, J.G.
  • Irastorza, I.G.
  • Luzón, G.
  • Mirallas, H.
  • Ruiz-Choliz, E.
In the search for the neutrinoless double beta decay of 136Xe, a high pressure xenon time projection chamber (HPXe-TPC) has two advantages over liquid xenon TPCs: a better energy resolution and the access to topological features, which may provide extra discrimination from background events. The PandaX-III experiment has recently proposed a 200 kg HPXe-TPC based on Micromegas readout planes, to be located at the Jinping Underground Laboratory in China. Its detection concept is based on two results obtained within the T-REX project: Micromegas readouts can be built with extremely low levels of radioactivity; and the operation in xenon-trimethylamine at 10 bar in realistic experimental conditions has proven an energy resolution of 3% FWHM at the region of interest. In this work, two discrimination methods are applied to simulated signal and background data in a generic 200 kg HPXe-TPC, based on two well-known algorithms of graph theory: the identification of connections and the search for the longest path. Rejection factors greater than 100 are obtained for small pixel sizes and a signal efficiency of 40%. Moreover, a new observable (the blob charge density) rejects better surface contaminations, which makes the use of a trigger signal (T0) not imperative in this experiment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Micromegas for dark matter searches: CAST/IAXO & TREX-DM experiments

  • Garza, J.G.
  • Aune, S.
  • Aznar, F.
  • Castel, J.F.
  • Cebrian, S.
  • Dafni, T.
  • Ferrer-Ribas, E.
  • Galan, J.
  • Garcia, J.A.
  • Giomataris, I.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Luzon, G.
  • Mirallas, H.
  • Papaevangelou, T.
  • Peiro, A.
  • Tomas, A.
  • Vafeiadis, T.
The most compelling candidates for Dark Matter to day are WIMPs and axions. The applicability of gasesous Time Projection Chambers (TPCs) with Micromesh Gas Structures (Micromegas) to the search of these particles is explored within this work. Both particles would produce an extremely low rate at very low energies in particle detectors. Micromegas detectors can provide both low background rates and low energy threshold, due to the high granularity, radiopurity and uniformity of the readout. Small (few cm wide) Micromegas detectors are used to image the ax ion-induced x-ray signal expected in the CERN Axion Solar Telescope (CAST) experiment. We show the background levels obtained in CAST and the prospects to further reduce them to the values required by the Internation Axion Observatory (IAXO). We also present TREX-DM. a scaled-up version of the Micromegas used in axion research, but this time dedicated to the low-mass WIMP detection. TREX-DM is a high-pressure Micromegas-based TPC designed to host a few hundreds of grams of light nuclei (argon or neon) with energy thresholds potentially at the level of 100 eV. The detector is described in detail, as well as the results of the commissioning and characterization phase on surface. Besides, the background model of TREX-DM is presented, along with the anticipated sensitivity of this search, which could go beyond current experimental limits.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Improved search for solar chameleons with a GridPix detector at CAST

  • Anastassopoulos, V.
  • Aune, S.
  • Barth, K.
  • Belov, A.
  • Brauninger, H.
  • Cantatore, G.
  • Carmona, J.M.
  • Castel, J.F.
  • Cetin, S.A.
  • Christensen, F.
  • Dafni, T.
  • Davenport, M.
  • Dermenev, A.
  • Desch, K.
  • Dobrich, B.
  • Eleftheriadis, C.
  • Fanourakis, G.
  • Ferrer-Ribas, E.
  • Fischer, H.
  • Funk, W.
  • Garcia, J.A.
  • Gardikiotis, A.
  • Garza, J.G.
  • Gazis, E.N.
  • Geralis, T.
  • Giomataris, I.
  • Gninenko, S.
  • Hailey, C.J.
  • Hasinoff, M.D.
  • Hoffmann, D.H.H.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jakobsen, A.
  • Jacoby, J.
  • Jakovcic, K.
  • Kaminski, J.
  • Karuza, M.
  • Kostoglou, S.
  • Kralj, N.
  • Krcmar, M.
  • Krieger, C.
  • Lakic, B.
  • Laurent, J.M.
  • Liolios, A.
  • Ljubicic, A.
  • Luzon, G.
  • Maroudas, M.
  • Miceli, L.
  • Neff, S.
  • Ortega, I.
  • Papaevangelou, T.
  • Paraschou, K.
  • Pivovaroff, M.J.
  • Raffelt, G.
  • Rosu, M.
  • Ruz, J.
  • Choliz, E.R.
  • Savvidis, I.
  • Schmidt, S.
  • Semertzidis, Y.K.
  • Solanki, S.K.
  • Stewart, L.
  • Vafeiadis, T.
  • Vogel, J.K.
  • Vretenar, M.
  • Wuensch, W.
  • Yildiz, S.C.
  • Zioutas, K.
  • Brax, P.
We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No significant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling, beta(gamma) less than or similar to 5.7 x 10(10) for 1 < beta(m) < 10(6) at 95% C.L. improving our previous results by a factor two and for the first time reaching sensitivity below the solar luminosity bound for tachocline magnetic fields up to 12.5 T.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Cosmogenic production of tritium in dark matter detectors

  • Amaré, J.
  • Castel, J.
  • Cebrián, S.
  • Coarasa, I.
  • Cuesta, C.
  • Dafni, T.
  • Galán, J.
  • García, E.
  • Garza, J.G.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Luzón, G.
  • Martínez, M.
  • Mirallas, H.
  • Oliván, M.A.
  • Ortigoza, Y.
  • Ortiz de Solórzano, A.
  • Puimedón, J.
  • Ruiz-Chóliz, E.
  • Sarsa, M.L.
  • Villar, J.A.
  • Villar, P.
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and long half-life) when induced in the detector medium, and because it can be generated in any material as a spallation product. Quantification of cosmogenic production of tritium is not straightforward, neither experimentally nor by calculations. In this work, a method for the calculation of production rates at sea level has been developed and applied to some of the materials typically used as targets in dark matter detectors (germanium, sodium iodide, argon and neon); it is based on a selected description of tritium production cross sections over the entire energy range of cosmic nucleons. Results have been compared to available data in the literature, either based on other calculations or from measurements. The obtained tritium production rates, ranging from a few tens to a few hundreds of nuclei per kg and per day at sea level, point to a significant contribution to the background in dark matter experiments, requiring the application of specific protocols for target material purification, material storing underground and limiting the time the detector is on surface during the building process in order to minimize the exposure to the most dangerous cosmic ray components.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Axion searches with microwave filters: The RADES project

  • Melcón, A.Á.
  • Cuendis, S.A.
  • Cogollos, C.
  • Díaz-Morcillo, A.
  • Döbrich, B.
  • Gallego, J.D.
  • Gimeno, B.
  • Irastorza, I.G.
  • Lozano-Guerrero, A.J.
  • Malbrunot, C.
  • Navarro, P.
  • Garay, C.P.
  • Redondo, J.
  • Vafeiadis, T.
  • Wuensch, W.
We propose, design and construct a variant of the conventional axion haloscope concept that could be competitive in the search for dark matter axions of masses in the decade 10-100 µeV. Theses masses are located somewhat above the mass range in which existing experiments have reached sensitivity to benchmark QCD axion models. Our haloscope consists of an array of small microwave cavities connected by rectangular irises, in an arrangement commonly used in radio-frequency filters. The size of the unit cavity determines the main resonant frequency, while the possibility to connect a large number of cavities allows to reach large detection volumes. We develop the theoretical framework of the detection concept, and present design prescriptions to optimize detection capabilities. We describe the design and realization of a first small-scale prototype of this concept, called Relic Axion Detector Exploratory Setup (RADES). It consists of a copper-coated stainless steel five-cavities microwave filter with the detecting mode operating at around 8.4 GHz. This structure has been electromagnetically characterized at 2 K and 298 K, and it is now placed in ultra-high vacuum in one of the twin-bores of the 9 T CAST dipole magnet at CERN. We describe the data acquisition system developed for relic axion detection, and present preliminary results of the electromagnetic properties of the microwave filter, which show the potential of filters to reach QCD axion window sensitivity at X-band frequencies.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Reseña (Review)

New experimental approaches in the search for axion-like particles

  • Irastorza, I.G.
  • Redondo, J.
Axions and other very light axion-like particles appear in many extensions of the Standard Model, and are leading candidates to compose part or all of the missing matter of the Universe. They also appear in models of inflation, dark radiation, or even dark energy, and could solve some long-standing astrophysical anomalies. The physics case of these particles has been considerably developed in recent years, and there are now useful guidelines and powerful motivations to attempt experimental detection. Admittedly, the lack of a positive signal of new physics at the high energy frontier, and in underground detectors searching for weakly interacting massive particles, is also contributing to the increase of interest in axion searches. The experimental landscape is rapidly evolving, with many novel detection concepts and new experimental proposals. An updated account of those initiatives is lacking in the literature. In this review we attempt to provide such an update. We will focus on the new experimental approaches and their complementarity, but will also review the most relevant recent results from the consolidated strategies and the prospects of new generation experiments under consideration in the field. We will also briefly review the latest developments of the theory, cosmology and astrophysics of axions and we will discuss the prospects to probe a large fraction of relevant parameter space in the coming decade.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Imaging in (high pressure) Micromegas TPC detectors

  • Luzón, G.
  • Cebrián, S.
  • Castel, J.
  • Dafni, T.
  • Galán, J.
  • Garza, J. G.
  • Irastorza, I. G.
  • Iguaz, F. J.
  • Mirallas, H.
  • Ruíz-Choliz, E.
The T-REX project of the group of the University of Zaragoza includes a number of R&D and prototyping activities to explore the applicability of gaseous Time Projection Chambers (TPCs) with Micromesh Gas Structures (Micromegas) in rare event searches where the pattern recognition of the signal is crucial for background discrimination. In the CAST experiment (CERN Axion Solar Telescope) a background level as low as 0.8 × 10-6 counts keV-1 cm-2 s-1 was achieved. Prototyping and simulations promise a 105 better signal-to-noise ratio than CAST for the future IAXO (International Axion Observatory) using x-ray telescopes. A new strategy is also explored in the search of WIMPS based on high gas pressure: the TREX-DM experiment, a low energy threshold detector. In both cases, axion and WIMP searches, the image of the expected signal is quite simple: a one cluster deposition coming from the magnet bore in the case of axions and, if possible, with a tadpole form in the case of WIMPs. It is the case of double beta decay (DBD) where imaging and pattern recognition play a major role. Results obtained in Xe + trimethylamine (TMA) mixture point to a reduction in electron diffusion which improves the quality of the topological pattern, with a positive impact on the discrimination capability, as shown in TREX-ßß prototype. Microbulk Micromegas are able to image the DBD ionization signature with high quality while, at the same time, measuring its energy deposition with a resolution of at least a ~ 3% FWHM at the transition energy Qßß and even better (up to ~ 1% FWHM) as extrapolated from low energy events. That makes Micromegas-based HPXe TPC a very competitive technique for the next generation DBD experiments (as PANDAX-III). Here, it will be shown the last results of the TREX project detectors and software concerning Axions, Dark matter and double beta decay.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Background assessment for the TREX dark matter experiment

  • Castel, J.
  • Cebrian, S.
  • Coarasa, I.
  • Dafni, T.
  • Galan, J.
  • Iguaz, F.J.
  • García Irastorza, I.
  • Luzón, G.
  • Mirallas, H.
  • Ortiz de Solórzano, A.
  • Ruiz-Chóliz, E.
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with Micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20l\{-69pt}begin{document}$$\sim 20l$$\end{document} of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The Micromegas are read with a self-triggered acquisition, being thresholds below 0.4 keV (electron equivalent) at reach. A low background level in the lowest energy region is another essential requirement. To assess the expected background, all the relevant sources have been considered, including the measured fluxes of gamma radiation, muons and neutrons at the Canfranc Laboratory, together with the activity of most of the components used in the detector and ancillary systems, obtained in a complete assay program. The background contributions have been simulated by means of a dedicated application based on Geant4 and a custom-made code for the detector response. The background model developed for the detector presently installed in Canfranc points to levels from 1 to 10 counts keV-1kg-1day-1\documentclass[12pt]{minimal}{-\begin{document}$$\hbox {keV}<^>{-1}\ \hbox {kg}<^>{-1}\ \hbox {day}<^>{-1}$$\end{document} in the region of interest, making TREX-DM competitive in the search for low-mass WIMPs. A roadmap to further decrease it down to 0.1 counts keV(-1)kg(-1)day(-1)}\ \hbox {day}<^>{-1}$$\end{document} is underway.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Status of the TREX-DM experiment at the Canfranc Underground Laboratory

  • Aznar, F.
  • Castel, J.
  • Cebrián, S.
  • Coarasa, I.
  • Dafni, T.
  • Galán, J.
  • Irastorza, I.G.
  • Luzón, G.
  • Mirallas, H.
  • Ortiz De Solórzano, A.
  • Peiró, A.
  • Ruiz-Chóliz, E.
The TREX-DM experiment is conceived to look for low mass WIMPs by means of a gas time projection chamber equipped with novel micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold 20 l of pressurized gas up to 10 bar, which corresponds to 0.30 kg of Ar, or alternatively, 0.16 kg of Ne. The micromegas will be read with a self-triggered acquisition, allowing for effective thresholds below 0.4 keV (electron equivalent). The preliminary background model, following a complete material screening program, points to levels of the order of 1-10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive. The status of the commissioning, description of the background model and the corresponding WIMP sensitivity will be presented here.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Contribución de congreso (ConferenceOutput)

Low Background Micromegas in CAST

  • Garza, J.G.
  • Aune, S.
  • Aznar, F.
  • Calvet, D.
  • Castel, J.F.
  • Christensen, F.E.
  • Dafni, T.
  • Davenport, M.
  • Decker, T.
  • Ferrer-Ribas, E.
  • Galán, J.
  • García, J.A.
  • Giomataris, I.
  • Hill, R.M.
  • Iguaz, F.J.
  • García Irastorza, I.
  • AJakobsen, A.C.
  • Jourde, D.
  • Mirallas, H.
  • Ortega, I.
  • Papaevangelou, T.
  • Pivovaroff, M.J.
  • Ruz, J.
  • Tomás, A.
  • Vafeiadis, T.
  • Vogel, J.K.
Solar axions could be converted into x-rays inside the strong magnetic field of an axion helioscope, triggering the detection of this elusive particle. Low background x-ray detectors are an essential component for the sensitivity of these searches. We report on the latest developments of the Micromegas detectors for the CERN Axion Solar Telescope (CAST), including technological pathfinder activities for the future International Axion Observatory (IAXO). The use of low background techniques and the application of discrimination algorithms based on the high granularity of the readout have led to background levels below 10-6 counts/keV/cm2/s, more than a factor 100 lower than the first generation of Micromegas detectors. The best levels achieved at the Canfranc Underground Laboratory (LSC) are as low as 10-7 counts/keV/cm2/s, showing good prospects for the application of this technology in IAXO. The current background model, based on underground and surface measurements, is presented, as well as the strategies to further reduce the background level. Finally, we will describe the R&D paths to achieve sub-keV energy thresholds, which could broaden the physics case of axion helioscopes.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The TREX-DM experiment at the Canfranc Underground Laboratory

  • Castel, J.
  • Cebrián, S.
  • Dafni, T.
  • Galán, J.
  • Irastorza, I.G.
  • Luzón, G.
  • Margalejo, C.
  • Mirallas, H.
  • Ortiz De Solórzano, A.
  • Peiró, A.
  • Ruiz-Chóliz, E.
TREX-DM (TPC Rare Event eXperiment for Dark Matter) is intended to look for low mass WIMPs in the Canfranc Underground Laboratory (LSC) in Spain, using light elements (Ne, Ar) as target in a high pressure TPC equipped with Micromegas readouts. Here, a description of the detector, the first results from commissioning data and the expected sensitivity from the developed background model are briefly presented.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

First results on the search for chameleons with the KWISP detector at CAST

  • Arguedas Cuendis, S.
  • Baier, J.
  • Barth, K.
  • Baum, S.
  • Bayirli, A.
  • Belov, A.
  • Bräuninger, H.
  • Cantatore, G.
  • Carmona, J.M.
  • Castel, J.F.
  • Cetin, S.A.
  • Dafni, T.
  • Davenport, M.
  • Dermenev, A.
  • Desch, K.
  • Döbrich, B.
  • Fischer, H.
  • Funk, W.
  • García, J.A.
  • Gardikiotis, A.
  • Garza, J.G.
  • Gninenko, S.
  • Hasinoff, M.D.
  • Hoffmann, D.H.H.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Jakovcic, K.
  • Kaminski, J.
  • Karuza, M.
  • Krieger, C.
  • Lakic, B.
  • Laurent, J.M.
  • Luzón, G.
  • Maroudas, M.
  • Miceli, L.
  • Neff, S.
  • Ortega, I.
  • Ozbey, A.
  • Pivovaroff, M.J.
  • Rosu, M.
  • Ruz, J.
  • Chóliz, E.R.
  • Schmidt, S.
  • Schumann, M.
  • Semertzidis, Y.K.
  • Solanki, S.K.
  • Stewart, L.
  • Tsagris, I.
  • Vafeiadis, T.
  • Vogel, J.K.
  • Vretenar, M.
  • Yildiz, S.C.
  • Zioutas, K.
We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of solar chameleons. The displacements are detected by a Michelson interferometer with a homodyne readout scheme. The sensor benefits from the focusing action of the ABRIXAS X-ray telescope installed at CAST, which increases the chameleon flux on the membrane. A mechanical chopper placed between the telescope output and the detector modulates the incoming chameleon stream. We present the results of the solar chameleon measurements taken at CAST in July 2017, setting an upper bound on the force acting on the membrane of 80pN at 95% confidence level. The detector is sensitive for direct coupling to matter 104 = ßm = 108, where the coupling to photons is locally bound to ß¿ = 1011.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Microbulk Micromegas in non-flammable mixtures of argon and neon at high pressure

  • Iguaz, F. J.
  • Dafni, T.
  • Canellas, C.
  • Castel, J. F.
  • Cebrián, S.
  • Garza, J. G.
  • García Irastorza, I.
  • Luzón, G.
  • Mirallas, H.
  • Ruiz-Chóliz, E.
We report on a systematic characterization of microbulk Micromegas readouts in high-pressure Ar+1%iC4H10 and Ne+2%iC4H10 mixtures. Experimental data on gain, electron transmission and energy resolution are presented for a wide range of drift and amplification voltages and pressures from 1 bar to 10 bar for the argon mixture and from 5 bar to 10 bar in the neon mixture, in steps of 1 bar. Maximum gains higher than 1.7 × 103 (1.7 × 104) in the argon (neon) mixture are measured for all pressures, without the significant decrease with pressure typically observed in other amplification structures. A competitive energy resolution at 22.1 keV, but with a slight degradation with pressure, is observed: from 10.8% at 1 bar to 15.6% FWHM at 10 bar in Ar+1%iC4H10 and from 8.3% at 5 bar to 15.0% FWHM at 10 bar in Ne+2%iC4H10. The experimental setup, procedure and the results will be presented and discussed in detail. The work is motivated by the TREX-DM experiment, that is operating in the Laboratorio Subterráneo de Canfranc with the mentioned mixtures, although the results may be of interest for other applications of time projection chambers at high pressures.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The T-REX project: Micromegas for rare event searches

  • Dafni, T.
  • Aune, S.
  • Castel, J.
  • Cebrián, S.
  • Fanourakis, G.
  • Ferrer-Ribas, E.
  • Fortuño, D.
  • Galán, J.
  • García, J.A.
  • Gardikiotis, A.
  • Garza, J.G.
  • Geralis, T.
  • Giomataris, I.
  • Gómez, H.
  • Herrera, D.C.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Luzón, G.
  • Mols, J.P.
  • Ortiz, A.
  • Papaevangelou, T.
  • Rodríguez, A.
  • Ruz, J.
  • Segui, L.
  • Tomás, A.
  • Vafeiadis, T.
  • Yildiz, S.C.
The T-REX project aims at developing novel readout techniques for Time Projection Chambers for experiments searching for Rare Events. The Micromegas detectors are a good option, because of their good performance regarding low background levels, energy and time resolution, gain and stability of operation. In the present we will shortly refer to two particular cases, on one hand their performance in the CAST experiment and on the other the studies carried out within NEXT, a neutrinoless double-beta decay experiment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Performance of micromegas detectors in the CAST Experiment

  • Yildiz, S.C.
  • Aune, S.
  • Dafni, T.
  • Davenport, M.
  • Fanourakis, G.
  • Ferrer-Ribas, E.
  • Galán, J.
  • García, J.A.
  • Gardikiotis, A.
  • Garza, J.G.
  • Geralis, T.
  • Giomataris, I.
  • Gómez, H.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Papaevangelou, T.
  • Rodríguez, A.
  • Ruz, J.
  • Tomás, A.
  • Vafeiadis, T.
CERN Axion Solar Telescope (CAST) experiment is searching for axions coming from the Sun. Inside transverse magnetic fields, axions can be converted into X-rays, which can be detected by X-ray detectors. The expected energy of the signal in CAST is in the 1-10 keV range. Low noise and low background detectors are necessary to increase the sensitivity of the experiment. Micro Mesh Gaseous Structure (micromegas) detectors have been used in CAST since the beginning, providing good energy and spatial resolution for CAST's needs. CAST has been intensely studying micromegas detectors to develop new technologies. Initially, CAST detectors consisted of a micromegas, a Time Projection Chamber (TPC) and a Charged Couple Device (CCD), however the improvements in micromegas technologies encouraged CAST to replace the TPC with 2 new micromegas detectors. In some periods during CAST run, ultra low background has been observed in one of the micromegas detectors and it is being investigated through simulations and laboratory tests carried out at Canfranc Underground Laboratory. If this low background is indeed not a systematic effect, it can open new possibilities on rare event searches.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Conceptual design of the International Axion Observatory (IAXO)

  • Armengaud, E.
  • Avignone, F.T.
  • Betz, M.
  • Brax, P.
  • Brun, P.
  • Cantatore, G.
  • Carmona, J.M.
  • Carosi, G.
  • Caspers, F.
  • Caspi, S.
  • Cetin, S.A.
  • Chelouche, D.
  • Christensen, F.E.
  • Dael, A.
  • Dafni, T.
  • Davenport, M.
  • Derbin, A.V.
  • Desch, K.
  • Diago, A.
  • Döbrich, B.
  • Dratchnev, I.
  • Dudarev, A.
  • Eleftheriadis, C.
  • Fanourakis, G.
  • Ferrer-Ribas, E.
  • Galán, J.
  • García, J.A.
  • Garza, J.G.
  • Geralis, T.
  • Gimeno, B.
  • Giomataris, I.
  • Gninenko, S.
  • Gómez, H.
  • González-Díaz, D.
  • Guendelman, E.
  • Hailey, C.J.
  • Hiramatsu, T.
  • Hoffmann, D.H.H.
  • Horns, D.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Isern, J.
  • Imai, K.
  • Jakobsen, A.C.
  • Jaeckel, J.
  • Jakovcic, K.
  • Kaminski, J.
  • Kawasaki, M.
  • Karuza, M.
  • Krcmar, M.
  • Kousouris, K.
  • Krieger, C.
  • Lakic, B.
  • Limousin, O.
  • Lindner, A.
  • Liolios, A.
  • Luzón, G.
  • Matsuki, S.
  • Muratova, V.N.
  • Nonesa, C.
  • Ortega, I.
  • Papaevangelou, T.
  • Pivovaroff, M.J.
  • Raffelt, G.
  • Redondo, J.
  • Ringwald, A.
  • Russenschuck, S.
  • Ruz, J.
  • Saikawa, K.
  • Savvidis, I.
  • Sekiguchi, T.
  • Semertzidis, Y.K.
  • Shilon, I.
  • Sikivie, P.
  • Silva, H.
  • ten Kate, H.
  • Tomas, A.
  • Troitsky, S.
  • Vafeiadis, T.
  • van Bibber, K.
  • Vedrine, P.
  • Villar, J.A.
  • Vogel, J.K.
  • Walckiers, L.
  • Weltman, A.
  • Wester, W.
  • Yildiz, S.C.
  • Zioutas, K.
The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4–5 orders of magnitude more sensitive than CAST, currently the most powerful axion helioscope, reaching sensitivity to axion-photon couplings down to a few × 10−12 GeV−1 and thus probing a large fraction of the currently unexplored axion and ALP parameter space. IAXO will also be sensitive to solar axions produced by mechanisms mediated by the axion-electron coupling gae with sensitivity — for the first time — to values of gae not previously excluded by astrophysics. With several other possible physics cases, IAXO has the potential to serve as a multi-purpose facility for generic axion and ALP research in the next decade. In this paper we present the conceptual design of IAXO, which follows the layout of an enhanced axion helioscope, based on a purpose-built 20 m-long 8-coils toroidal superconducting magnet. All the eight 60cm-diameter magnet bores are equipped with focusing x-ray optics, able to focus the signal photons into ∼ 0.2 cm2 spots that are imaged by ultra-low-background Micromegas x-ray detectors. The magnet is built into a structure with elevation and azimuth drives that will allow for solar tracking for ∼ 12 h each day.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Future axion searches with the International Axion Observatory (IAXO)

  • Irastorza, I.G.
  • Avignone, F.T.
  • Cantatore, G.
  • Carmona, J.M.
  • Caspi, S.
  • Cetin, S.A.
  • Christensen, F.E.
  • Dael, A.
  • Dafni, T.
  • Davenport, M.
  • Derbin, A.V.
  • Desch, K.
  • Diago, A.
  • Döbrich, B.
  • Dudarev, A.
  • Eleftheriadis, C.
  • Fanourakis, G.
  • Ferrer-Ribas, E.
  • Galán, J.
  • García, J.A.
  • Garza, J.G.
  • Geralis, T.
  • Gimeno, B.
  • Giomataris, I.
  • Gninenko, S.
  • Gómez, H.
  • Guendelman, E.
  • Hailey, C.J.
  • Hiramatsu, T.
  • Hoffmann, D.H.H.
  • Horns, D.
  • Iguaz, F.J.
  • Isern, J.
  • Jakobsen, A.C.
  • Jaeckel, J.
  • Jakovcic, K.
  • Kaminski, J.
  • Kawasaki, M.
  • Krmar, M.
  • Krieger, C.
  • Lakic, B.
  • Lindner, A.
  • Liolios, A.
  • Luzón, G.
  • Ortega, I.
  • Papaevangelou, T.
  • Pivovaroff, M.J.
  • Raffelt, G.
  • Redondo, J.
  • Ringwald, A.
  • Russenschuck, S.
  • Ruz, J.
  • Saikawa, K.
  • Savvidis, I.
  • Sekiguchi, T.
  • Shilon, I.
  • Sikivie, P.
  • Silva, H.
  • Ten Kate, H.
  • Tomas, A.
  • Troitsky, S.
  • Vafeiadis, T.
  • Van Bibber, K.
  • Vedrine, P.
  • Villar, J.A.
  • Vogel, J.K.
  • Walckiers, L.
  • Wester, W.
  • Yildiz, S.C.
  • Zioutas, K.
The International Axion Observatory (IAXO) is a new generation axion helioscope aiming at a sensitivity to the axion-photon coupling of ga¿ gsim few × 10-12 GeV-1, i.e. 1–1.5 orders of magnitude beyond the one achieved by CAST, currently the most sensitive axion helioscope. The main elements of IAXO are an increased magnetic field volume together with extensive use of x-ray focusing optics and low background detectors, innovations already successfully tested in CAST. Additional physics cases of IAXO could include the detection of electron-coupled axions invoked to explain the white dwarf cooling, relic axions, and a large variety of more generic axion-like particles (ALPs) and other novel excitations at the low-energy frontier of elementary particle physics.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Low X-ray background measurements at the Underground Canfranc Laboratory

  • Galán, J.
  • Aune, S.
  • Dafni, T.
  • Fanourakis, G.
  • Ferrer-Ribas, E.
  • García, J.A.
  • Gardikiotis, A.
  • Geralis, T.
  • Giomataris, I.
  • Gómez, H.
  • Garza, J.G.
  • Herrera, D.C.
  • Iguaz, F.J.
  • Irastorza, I.G.
  • Luzón, G.
  • Papaevangelou, T.
  • Rodríguez, A.
  • Ruz, J.
  • Seguí, L.
  • Tomás, A.
  • Vafeiadis, T.
  • Yildiz, S.C.
Micromegas detectors, thanks to the good spatial and temporal discrimination capabilities, are good candidates for rare event search experiments. Recent X-ray background levels achieved by these detectors in the CAST experiment have motivated further studies in the nature of the background levels measured. In particular, different shielding configurations have been tested at the Canfranc Underground Laboratory, using a microbulk type detector which was previously running at the CAST experiment. The first results underground show that this technology, which is made of low radiative materials, is able to reach background levels up to 2x10^-7 keV^-1 s^-1 cm^-2 with a proper shielding. Moreover, the experimental background measurements are complemented with Geant4 simulations which allow to understand the origin of the background, and to optimize future shielding set-ups.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm

  • González-Díaz, D.
  • Álvarez, V.
  • Borges, F.I.G.
  • Camargo, M.
  • Cárcel, S.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Dafni, T.
  • Díaz, J.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D.C.
  • García-Irastorza, I.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lopez-March, N.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí, A.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • Miller, T.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Pérez, J.
  • Pérez Aparicio, J.L.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Santos, F.P.
  • Dos Santos, J.M.F.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
  • Azevedo, C.
  • Aznar, F.
  • Calvet, D.
  • Castel, J.
  • Ferrer-Ribas, E.
  • García, J.A.
  • Giomataris, I.
  • Gómez, H.
  • Iguaz, F.J.
  • Lagraba, A.
  • Le Coguie, A.
  • Mols, J.P.
  • Sahin, Ö.
  • Rodríguez, A.
  • Ruiz-Choliz, E.
  • Segui, L.
  • Tomás, A.
  • Veenhof, R.
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and ¿-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in ~1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3±0.13mm-s (longitudinal), 0.95±0.20mm-s (transverse) along 1 m drift) besides forming a convenient ''Penning-Fluorescent'' mixture. The TPC, that houses 1.1 kg of gas in its fiducial volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8mm×8mm×1.2mm for approximately 10 cm/MeV-long electron tracks. Resolution in energy (e) at full width half maximum (R) inside the fiducial volume ranged from R=14.6% (30 keV) to R=4.6%(1.275MeV). This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the neutrino-less double beta decay (ßß0¿) in 136Xe, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks. In particular, the obtained energy resolution has been decomposed in its various contributions and improvements towards achieving the R=1.4%v1MeV/e levels obtained in small sensors are discussed.