Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 67
Encontrada(s) 1 página(s)

Biblos-e Archivo. Repositorio Institucional de la UAM
Publicación Artículo científico (JournalArticle)

Electroluminescence TPCs at the thermal diffusion limit

  • Henriques, C. A.O.
  • Labarga Echeverría, Luis Alfonso
  • The Next Collaboration
Artículo escrito por un elevado número de autores, solo se referencian el que aparece en primer lugar, el nombre del grupo de colaboración, si le hubiere, y los autores pertenecientes a la UAM, The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the 136Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO2, CH4 and CF4) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/m for pure xenon down to 2.5 mm/m using additive concentrations of about 0.05%, 0.2% and 0.02% for CO2, CH4 and CF4, respectively. Our results show that CF4 admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH4 presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO2 and CH4 show potential as molecular additives in a large xenon TPC. While CO2 has some operational constraints, making it difficult to be used in a large TPC, CH4 shows the best performance and stability as molecular additive to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%, which is only slightly worse than the one obtained for pure xenon. We demonstrate the possibility to have an electroluminescence TPC operating very close to the thermal diffusion limit without jeopardizing the TPC performance, if CO2 or CH4 are chosen as additives.[Figure not available: see fulltext.], The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union’s Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Skłodowska-Curie Grant Agreements No.674896, 690575 and 740055; the Ministerio de Economía y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the María de Maetzu Program MDM-2016-0692;the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020(Texas A&M) and DE-SC0017721 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionalidel Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coatingof various parts of the NEXT-White TPC.
Biblos-e Archivo. Repositorio Institucional de la UAM
Publicación Artículo científico (JournalArticle)

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

  • Fernandes, A. F.M.
  • Labarga Echeverría, Luis Alfonso
  • NEXT collaboration
Artículo escrito por un elevado número de autores, solo se referencian el que aparece en primer lugar, los autores pertenecientes a la UAM y el nombre del grupo de colaboración, si lo hubiere, High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe–He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the EL region, the EL yield is lowered by ∼ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures, The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787- NEXT; the European Union’s Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economía y Competitividad of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the María de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015; the U.S. Department of Energy under contracts number DEAC02-06CH11357 (Argonne National Laboratory), DE-AC02- 07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A& M) and DE-SC0019223 / DESC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramón y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment
Biblos-e Archivo. Repositorio Institucional de la UAM
Publicación Artículo científico (JournalArticle)

Sensitivity of the NEXT experiment to Xe-124 double electron capture

  • Martínez-Lema, G.
  • NEXT collaboration
  • Labarga Echeverría, Luis Alfonso
Artículo escrito por un elevado número de autores, solo se referencian el que aparece en primer lugar, el nombre del grupo de colaboración, si le hubiere, y los autores pertenecientes a la UAM, Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture (2νEC EC) has been predicted for a number of isotopes, but only observed in 78Kr, 130Ba and, recently, 124Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, 0νEC EC. Here we report on the current sensitivity of the NEXT-White detector to 124Xe 2νEC EC and on the extrapolation to NEXT-100. Using simulated data for the 2νEC EC signal and real data from NEXT-White operated with 124Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124Xe and for a 5-year run, a sensitivity to the 2νEC EC half-life of 6 × 1022 y (at 90% confidence level) or better can be reached
Biblos-e Archivo. Repositorio Institucional de la UAM
Publicación Artículo científico (JournalArticle)

Mitigation of backgrounds from cosmogenic 137Xe in xenon gas experiments using 3He neutron capture

  • Rogers, L.
  • Labarga Echeverría, Luis Alfonso
  • NEXT collaboration
Artículo escrito por un elevado número de autores, solo se referencian el que aparece en primer lugar, los autores pertenecientes a la UAM y el nombre del grupo de colaboración, si lo hubiere, This is the Accepted Manuscript version of an article accepted for publication in Journal of Physics G: Nuclear and Particle Physics. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at 10.1088/1361-6471/ab8915, 136Xe is used as the target medium for many experiments searching for 0νββ. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of 137Xe created by the capture of neutrons on 136Xe. This isotope decays via beta decay with a half-life of 3.8 min and a Q β of ∼4.16 MeV. This work proposes and explores the concept of adding a small percentage of 3He to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from 137Xe activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory, The work described was supported by the Department of Energy under Award numbers DE-SC0019054 and DE-SC0019223. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union’s Framework Program for Research and Innovation Horizon 2020 (2014–2020) under the Marie Skłodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economía y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the María de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FISNUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011. Finally, we are grateful to the Laboratorio Subterráneo de Canfranc for hosting and supporting the NEXT experiment
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The Event Detection System in the NEXT-White Detector

  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Simón Estévez, Ander
  • Monrabal Capilla, Francesc
  • Rodriguez-Samaniego, Javier
  • Querol-Segura, Marc
[EN] This article describes the event detection system of the NEXT-White detector, a 5 kg high pressure xenon TPC with electroluminescent amplification, located in the Laboratorio Subterráneo de Canfranc (LSC), Spain. The detector is based on a plane of photomultipliers (PMTs) for energy measurements and a silicon photomultiplier (SiPM) tracking plane for offline topological event filtering. The event detection system, based on the SRS-ATCA data acquisition system developed in the framework of the CERN RD51 collaboration, has been designed to detect multiple events based on online PMT signal energy measurements and a coincidence-detection algorithm. Implemented on FPGA, the system has been successfully running and evolving during NEXT-White operation. The event detection system brings some relevant and new functionalities in the field. A distributed double event processor has been implemented to detect simultaneously two different types of events thus allowing simultaneous calibration and physics runs. This special feature provides constant monitoring of the detector conditions, being especially relevant to the lifetime and geometrical map computations which are needed to correct high-energy physics events. Other features, like primary scintillation event rejection, or a double buffer associated with the type of event being searched, help reduce the unnecessary data throughput thus minimizing dead time and improving trigger efficiency., The NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT, the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FISNUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The electronics of the energy plane of the NEXT-White detector

  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Laing, A.
  • Rodriguez-Samaniego, Javier
  • Querol-Segura, Marc
  • Monrabal, Francesc
  • Gómez-Cadenas, J.J.
[EN] This paper describes the electronics of NEXT-White (NEW) detector PMT plane, a high pressure xenon TPC with electroluminescent amplification (HPXe-EL) currently operating at the Laboratorio Subterraneo de Canfranc (LSC) in Huesca, Spain. In NEXT-White the energy of the event is measured by a plane of photomultipliers (PMTs) located behind a transparent cathode. The PMTs are Hamamatsu R11410-10 chosen due to their low radioactivity. The electronics have been designed and implemented to fulfill strict requirements: an overall energy resolution below 1% and a radiopurity budget of 20 mBq unit(-1) in the chain of Bi-214. All the components and materials have been carefully screened to assure a low radioactivity level and at the same time meet the required front-end electronics specifications. In order to reduce low frequency noise effects and enhance detector safety a grounded cathode connection has been used for the PMTs. This implies an AC-coupled readout and baseline variations in the PMT signals. A detailed description of the electronics and a novel approach based on a digital baseline restoration to obtain a linear response and handle AC coupling effects is presented. The final PMT channel design has been characterized with linearity better than 0.4% and noise below 0.4mV., We acknowledge support from the following agencies and institutions: the European Research Council (ERC), Spain under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program, Spain SEV-2014-0398 and the Maria de Maetzu Program, Spain MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT and FEDER, Spain through the program COMPETE, projects PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and de-sc0017721 (University of Texas at Arlington); and the University of Texas at Arlington. We acknowledge partial support from the European Union Horizon 2020 research and innovation programme, Spain under the Marie Sklodowska-Curie grant agreements No. 690575 and 674896. We also warmly acknowledge the Laboratorio Nazionale di Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Mitigation of backgrounds from cosmogenic Xe-137 in xenon gas experiments using He-3 neutron capture

  • Rogers, L.
  • Jones, B. J. P.
  • Laing, A.
  • Pingulkar, S.
  • Smithers, B.
  • Woodruff, K.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I. J.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Benlloch-Rodríguez, J. M.
  • Borges, F. I. G. M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Xe-136 is used as the target medium for many experiments searching for 0 nu beta beta. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of Xe-137 created by the capture of neutrons on Xe-136. This isotope decays via beta decay with a half-life of 3.8 min and a Q(beta) of similar to 4.16 MeV. This work proposes and explores the concept of adding a small percentage of He-3 to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from Xe-137 activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory., The work described was supported by the Department of Energy under Award numbers DE-SC0019054 and DE-SC0019223. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Program for Research and Innovation Horizon 2020 (2014-2020) under the Marie Skodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Background rejection in NEXT using deep neural networks

  • Renner, J.
  • Farbin, A.
  • Muñoz Vidal, J.
  • Benlloch-Rodríguez, J.M.
  • Botas, A.
  • Ferrario, P.
  • Gómez-Cadenas, J.J.
  • Álvarez, V.
  • Azevedo, C.D.R.
  • Borges, F.I.G.
  • Cárcel, S.
  • Carrión, J.V.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] We investigate the potential of using deep learning techniques to reject background events in searches for neutrinoless double beta decay with high pressure xenon time projection chambers capable of detailed track reconstruction. The differences in the topological signatures of background and signal events can be learned by deep neural networks via training over many thousands of events. These networks can then be used to classify further events as signal or background, providing an additional background rejection factor at an acceptable loss of efficiency. The networks trained in this study performed better than previous methods developed based on the use of the same topological signatures by a factor of 1.2 to 1.6, and there is potential for further improvement., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain and FEDER under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; GVA under grant PROMETEO/2016/120. Fermilab is operated by Fermi Research Alliance, LLC under Contract No. DE-AC02-07CH11359 with the United States Department of Energy. JR acknowledges support from a Fulbright Junior Research Award.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment

  • Ferrario, P.
  • Laing, A.
  • Lopez-March, N.
  • Gomez-Cadenas, J. J.
  • Azevedo, C. D. R.
  • Borges, F.I.G.
  • Carcel, S.
  • Cebrian, S.
  • Cervera, A.
  • C.A.N. Conde
  • Dafni, T.
  • Diaz, J.
  • Diesburg, M.
  • Pérez-Aparicio, José L.
  • Querol, M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT experiment aims to observe the neutrinoless double beta decay of 136Xe in a high-pressure xenon gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qββ . This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype. Single electrons resulting from the interactions of 22Na 1275 keV gammas and electron-positron pairs produced by conversions of gammas from the 228Th decay chain were used to represent the background and the signal in a double beta decay. These data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 ± 1.4 (stat.)%, while maintaining an efficiency of 66.7 ± 1.% for signal events., This work was supported by the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04 and FIS2012-37947-C04; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008; and the Fermi National Accelerator Laboratory under U.S. Department of Energy Contract No. DE-AC02-07CH11359
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Demonstration of background rejection using deep convolutional neural networks in the NEXT experiment

  • Kekic, M.
  • Adams, C.
  • Woodruff, K.
  • Renner, J.
  • Church, E.
  • Del Tutto, M.
  • Hernando Morata, J. A.
  • Gomez-Cadenas, J. J.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Convolutional neural networks (CNNs) are widely used state-of-the-art computer vision tools that are becoming increasingly popular in high-energy physics. In this paper, we attempt to understand the potential of CNNs for event classification in the NEXT experiment, which will search for neutrinoless double-beta decay in Xe-136. To do so, we demonstrate the usage of CNNs for the identification of electron-positron pair production events, which exhibit a topology similar to that of a neutrinoless double-beta decay event. These events were produced in the NEXT-White high-pressure xenon TPC using 2.6 MeV gamma rays from a Th-228 calibration source. We train a network on Monte Carlo-simulated events and show that, by applying on-the-fly data augmentation, the network can be made robust against differences between simulation and data. The use of CNNs offers significant improvement in signal efficiency and background rejection when compared to previous non-CNN-based analyses, This study used computing resources from Artemisa, co-funded by the European Union through the 2014-2020 FEDER Operative Programme of the Comunitat Valenciana, project DIFEDER/2018/048. This research used resources of the Argonne Leadership Computing Facility, which is a DOE Office of Science User Facility supported under Contract DE-AC02-06CH11357. The NEXT collaboration acknowledges support from the following agencies and institutions: Xunta de Galicia (Centro singularde investigacion de Galicia accreditation 2019-2022), by European Union ERDF, and by the "Maria de Maeztu" Units of Excellence program MDM-2016-0692 and the Spanish Research State Agency"; the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-20140398 and CEX2018-000867-S; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015 18820. JMA acknowledges support from Fundacion Bancaria "la Caixa" (ID 100010434), grant code LCF/BQ/PI19/11690012. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Characterisation of NEXT-DEMO using xenon Ka X-rays

  • Lorca, D.
  • Martín Albo, J.
  • Laing, A.
  • Ferrario, P.
  • Gómez Cadenas, J.J.
  • Álvarez, V.
  • Borges, F.I.G.
  • Camargo, M.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Marí Romero, Antonio Francisco
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Pérez Aparicio, José Luis
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT experiment aims to observe the neutrinoless double beta decay of 136Xe in a high-pressure xenon gas TPC using electroluminescence (EL) to amplify the signal from ionization. Understanding the response of the detector is imperative in achieving a consistent and well understood energy measurement. The abundance of xenon K-shell X-ray emission during data taking has been identified as a multitool for the characterisation of the fundamental parameters of the gas as well as the equalisation of the response of the detector. The NEXT-DEMO prototype is a 1.5 kg volume TPC filled with natural xenon. It employs an array of 19 PMTs as an energy plane and of 256 SiPMs as a tracking plane with the TPC light tube and SiPM surfaces being coated with tetraphenyl butadiene (TPB) which acts as a wavelength shifter for the VUV scintillation light produced by xenon. This paper presents the measurement of the properties of the drift of electrons in the TPC, the effects of the EL production region, and the extraction of position dependent correction constants using Ka X-ray deposits. These constants were used to equalise the response of the detector to deposits left by gammas from 22Na., This work was supported by the following agencies and institutions: the European Research Council under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04 and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Investigation of the CRT performance of a PET scanner based in liquid xenon: a Monte Carlo study

  • Gómez-Cadenas, J. J.
  • Benlloch-Rodriguez, J. M.
  • Ferrario, Paola
  • Monrabal, F.
  • Rodriguez-Samaniego, Javier
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
The measurement of the time of flight of the two 511 keV gammas recorded in coincidence in a PET scanner provides an effective way of reducing the random background and therefore increases the scanner sensitivity, provided that the coincidence resolving time (CRT) of the gammas is sufficiently good. Existing commercial systems based in LYSO crystals, such as the GEMINIS of Philips, reach CRT values of 600 ps (FWHM). In this paper we present a Monte Carlo investigation of the CRT performance of a PET scanner exploiting the scintillating properties of liquid xenon. We find that an excellent CRT of 60 70 ps (depending on the PDE of the sensor) can be obtained if the scanner is instrumented with silicon photomultipliers (SiPMs) sensitive to the ultraviolet light emitted by xenon. Alternatively, a CRT of 120 ps can be obtained instrumenting the scanner with (much cheaper) blue-sensitive SiPMs coated with a suitable wavelength shifter. These results show the excellent time of flight capabilities of a PET device based in liquid xenon., The authors acknowledge support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT, the Ministerio de Economia y Competitividad and FEDER of Spain, the Severo Ochoa Program SEV-2014-0398 and GVA under grant PROMETEO/2016/120; we acknowledge enlightening discussions with J. Varela and C. Lerche.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Contribución de congreso (ConferenceOutput)

Product Validation in Creative Processes: A Gender Perspective in Industrial Design Projects

  • Rojas, Juan-Carlos
  • Higuera-Trujillo, Juan Luis
  • Muniz, Gerardo
  • Marín-Morales, Javier|||0000-0003-1271-2892
[EN] Design education and practice are continuously evolving. Educational institutions must include intellectual complexities and new curriculum to support good design education. The design education future emerges multidisciplinary knowledge, teaching innovation and employment necessities. This paper describes a methodology centered in product validation with industrial design students. Focusing on discovering the student experience during the project execution, in addition to observing closely the female design student's perception on the methodology and process developed. The academic project was the design of a novel tool board. The students developed the proposed project in a period of eight weeks. Sixteen students participated as a sample of this research. The methodology consisted of eight phases that spanned from project brief to project conclusion, introducing two phases focused on validation exercises for the elements created to reach the solution of the tool board. During the end of the two evaluation phases, two surveys were applied asking for information on his previous experience during his design education and three elements that assessment the design methodology implementation: utility, novelty, and relevance. Using multiple choice and Likert scale answers the students answered the surveys. The survey's findings revealed relevant information on the project implementation focused on evaluation phases during the product design. The results revealed how students reflected on their previous experience developing projects, and how the design tool board integrate important phases like validation. Also, the students evaluated with a positive value the utility, novelty, and relevance of the developed project. However, the most important finding was the female perception comparing male students. The female assessment of novelty and relevance increased during project implementation, highlighting novelty as a perceived element to a greater range than men. This research results allowed us to discover more information about female students experience with creative and validation processes., The authors would also like to acknowledge the financial support provided by the NOVUS grant ID: N20-158-41 (Validación científica como herramienta educativa en proyectos de carácter creativo), as well as the support of the Writing Lab and TecLabs at Tecnologico de Monterrey, Mexico, throughout the production of this work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ionization and scintillation of nuclear recoils in gaseous xenon

  • Renner, J.
  • Gehman, V. M.
  • Goldschmidt, A.
  • Matis, H. S.
  • Miller, T.
  • Nakajima, Y.
  • Nygren, D.
  • Oliveira, C. A. B.
  • Shuman, D.
  • Alvarez, V.
  • Borges, F. I. G.
  • Carcel, S.
  • Castel, J.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Dafni, T.
  • Dias, T. H. V. T.
  • Diaz, J.
  • Evtoukhovitch, P.
  • Fernandes, L. M. P.
  • Ferrario, P.
  • Ferreira, A. L.
  • Freitas, E. D. C.
  • Gomez, H.
  • Gomez-Cadenas, J. J.
  • Gonzalez-Diaz, D.
  • Gutierrez, R. M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D. C.
  • Iguaz, F. J.
  • Irastorza, I. G.
  • Jinete, M. A.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lopes, J. A. M.
  • Lorca, D.
  • Losada, M.
  • Luzon, G.
  • Mari, A.
  • Martin-Albo, J.
  • Martinez, A.
  • Moiseenko, A.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C. M. B.
  • Moutinho, L. M.
  • Muñoz Vidal, J.
  • Natal da Luz, H.
  • Navarro, G.
  • Nebot-Guinot, M.
  • Palma, R.
  • Perez, J.
  • Pérez Aparicio, José Luis
  • Ripoll, L.
  • Rodriguez, A.
  • Rodriguez, J.
  • Santos, F. P.
  • dos Santos, J. M. F.
  • Segui, L.
  • Serra, L.
  • Simon, A.
  • Sofka, C.
  • Sorel, M.
  • Tomas, A.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J. F. C. A.
  • Villar, J. A.
  • Webb, R. C.
  • White, J.
  • Yahlali, N.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Gil, A.|||0000-0001-7192-6992
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
Abstract Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope α-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yields for nuclear recoils. The ability to discriminate between electronic and nuclear recoils using the ratio of ionization to primary scintillation is demonstrated. These results encourage further investigation on the use of xenon in the gas phase as a detector medium in dark matter direct detection experiments., This work was supported by the following agencies and institutions: the Director, Office of Science, Office of Basic Energy Sciences, of the U.S. Department of Energy, and the National Energy Research Scientific Computing Center (NERSC), supported by the Office of Science of the U.S. Department of Energy, both under Contract no. DE-AC02-05CH11231; the European Research Council under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under Grants CONSOLIDER-Ingenio 2010 C5D2008-0037 (CUP), FPA2009-13697-004-04, FPA2009-13697-C04-01, FIS2012-37947-C04-01, FIS2012-37947-C04-02, FIS2012-37947-C04-03, and FIS2012-37947-C04-04; and the Portuguese FCT and FEDER through the program COMPETE, Projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009. J. Renner acknowledges the support of a Department of Energy National Nuclear Security Administration Stewardship Science Graduate Fellowship, grant number DE-FC52-08NA28752.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Radiopurity assessment of the energy readout for the NEXT double beta decay experiment

  • Cebrian, S.
  • Perez, J.
  • Bandac, I.
  • Labarga, L.
  • Azevedo, C. D. R.
  • Benlloch-Rodriguez, J. M.
  • Borges, F. I. G. M.
  • Botas, A.
  • Carcel, S.
  • Carrión, J.V.
  • Conde, C. A. N.
  • Diaz, J.
  • Diesburg, M.
  • Escada, J.
  • Querol-Segura, Marc
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The "Neutrino Experiment with a Xenon Time-Projection Chamber" (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4 × 10¿4 counts per keV, kg and year, satisfying the sensitivity requirements of the NEXT experiment., Special thanks are due to LSC directorate and staff for their strong support for performing the measurements at the LSC Radiopurity Service. We are really grateful to Grzegorz Zuzel for the radon emanation measurements. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the GVA of Spain under grant PROMETEO/2016/120; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A & and the University of Texas at Arlington.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Electron drift properties in high pressure gaseous xenon

  • Simon, A.
  • Felkai, R.
  • Martinez-Lema, G.
  • Monrabal, F.
  • Gonzalez-Diaz, D.
  • Sorel, M.
  • Hernando Morata, J. A.
  • Gomez-Cadenas, J. J.
  • Adams, C.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and di¿usion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent ampli¿cation, a 1:2 scale model of the future NEXT-100detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December2016. The drift parameters have been measured using 83mKr for a range of reduced drift ¿elds at two di¿erent pressure regimes, namely 7.2 bar and 9.1 bar. Theresults have been compared with Magboltz simulations. Agreement at the 5% level or better has been found for drift velocity, longitudinal di¿usion and transverse di¿usion., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT and FEDER through the program COMPETE, projects PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and de-sc0017721 (University of Texas at Arlington); and the University of Texas at Arlington. We also warmly acknowledge the Laboratorio Nazionale di Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The Next White (NEW) detector

  • Monrabal, F.
  • Gomez-Cadenas, J. J.
  • Laing, A.
  • Benlloch-Rodriguez, J. M.
  • Carcel, S.
  • Carrion, J
  • Felkai, R.
  • Martinez, A.
  • Musti, M.
  • Ouero, M.
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
[EN] Conceived to host 5 kg of xenón at a pressure of 15 bar in the ¿ducial volume,the NEXTWhite (NEW)apparatus is currently the largest high pressure xenon gas TPC using electroluminescent ampli¿cation in the world. It is also a 1:2 scale model of the NEXT-100 detector scheduled to start searching for ßß0¿ decays in 136Xe in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2017 at the Canfranc Underground Laboratory (LSC), in Spain. This paper describes the detector and associated infrastructures., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT and FEDER through the program COMPETE, projects PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contract numbers DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0017721 (University of Texas at Arlington), and DE-AC02-06CH11357 (Argonne National Laboratory); and the University of Texas at Arlington. We also warmly acknowledge the Laboratorio Nazionale di Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Electroluminescence TPCs at the thermal diffusion limit

  • Henriques, C. A. O.
  • Monteiro, C. M. B.
  • Gonzalez-Diaz, D.
  • Azevedo, C. D. R.
  • Freitas, E. D. C.
  • Mano, R. D. P.
  • Jorge, M. R.
  • Fernandes, A. F. M.
  • Gomez-Cadenas, J. J.
  • Fernandes, L. M. P.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the 136Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO2, CH4 and CF4) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/ sqrt(¿) for pure xenon down to 2.5 mm/sqrt(m) using additive concentrations of about 0.05%, 0.2% and 0.02% for CO2, CH4 and CF4, respectively. Our results show that CF4 admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH4 presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO2 and CH4 show potential as molecular additives in a large xenon TPC. While CO2 has some operational constraints, making it difficult to be used in a large TPC, CH4 shows the best performance and stability as molecular additive to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%, which is only slightly worse than the one obtained for pure xenon. We demonstrate the possibility to have an electroluminescence TPC operating very close to the thermal diffusion limit without jeopardizing the TPC performance, if CO2 or CH4 are chosen as additives., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-AC02-06CH11357 (Argonne National Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0017721 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A programmable, multichannel power supply for SiPMs with temperature compensation loop and Ethernet interface

  • Querol-Segura, Marc
  • Rodriguez-Samaniego, Javier
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
Among the different techniques available, the SiPM power supply described in this paper uses output voltage and sensor temperature feedback. A high-resolution ADC digitizes both the output voltage and an analog signal proportional to the SiPM temperature for each of its 16 independent outputs. The appropriate change in the bias voltage is computed in a micro-controller and this correction is applied via a high resolution DAC to the control input of a DC/DC module that produces the output voltage. This method allows a reduction in gain variations from typically 30% to only 0.5% in a 10ºC range. The power supply is housed in a 3U-height aluminum box. A 2.8 touch screen on the front panel provides local access to the configuration and monitoring functions using a graphical interface. The unit has an Ethernet interface on its rear side to provide remote operation and integration in slow control systems using the encrypted and secure SSH protocol. A LabVIEW application with SSH interface has been designed to operate the power supply from a remote computer. The power supply has good characteristics, such as 85 V output range with 1 mV resolution and stability better than 2 mVP, excellent output load regulation and programmable rise and fall voltage ramps. Commercial power supplies from well-known manufacturers can show far better specifications though can also result in an over featured and over costly solution for typical applications., The authors acknowledge support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A & and the University of Texas at Arlington.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air

  • Ghosh, S.
  • Haefner, J.
  • Martín-Albo, J.
  • Guenette, R.
  • Li, X.
  • Loya Villalpando, A.A.
  • Burch, C.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Benlloch-Rodríguez, J.M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm We also see that the reflectance of PIFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM-2016-0692; the Generalitat Valenciana under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington (USA). DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC2015-18820. JM-A acknowledges support from Fundacion Bancaria "la Caixa" (ID 100010434), grant code LCF/BQ/PI19/11690012. Finally, we thank Brendon Bullard, Paolo Giromini and Neeraj Tata for helpful discussions and assistance with preliminary measurements.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Microscopic simulation of xenon-based optical TPCs in the presence of molecular additives

  • Azevedo, C.D.R.
  • Gonzalez-Diaz, D.
  • Biagi, S. F.
  • Oliveira, C. A. B.
  • Henriques, C. A. O.
  • Escada, J.
  • Monrabal, F.
  • Gomez-Cadenas, J. J.
  • Alvarez, V.
  • Querol-Segura, Marc
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] We introduce a simulation framework for the transport of high and low energy electrons in xenon-based optical time projection chambers (OTPCs). The simulation relies on elementary cross sections (electron-atom and electron-molecule) and incorporates, in order to compute the gas scintillation, the reaction/quenching rates (atom-atom and atom-molecule) of the first 41 excited states of xenon and the relevant associated excimers, together with their radiative cascade. The results compare positively with observations made in pure xenon and its mixtures with CO2 and CF4 in a range of pressures from 0.1 to 10 bar. This work sheds some light on the elementary processes responsible for the primary and secondary xenon-scintillation mechanisms in the presence of additives, that are of interest to the OTPC technology., DGD is supported by the Ramon y Cajal program (Spain) under contract number RYC-2015-18820. The authors want to acknowledge the RD51 collaboration for encouragement and support during the elaboration of this work, and in particular discussions with F. Resnati, A. Milov, V. Peskov, M. Suzuki and A. F. Borghesani. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the GVA of Spain under grant PROM-ETEO/2016/120; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A& and the University of Texas at Arlington.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Demonstration of Single-Barium-Ion Sensitivity for Neutrinoless Double-Beta Decay Using Single-Molecule Fluorescence Imaging

  • McDonald, A.D.
  • Jones, B.J.P.
  • Nygren, D.R.
  • Adams, C.
  • Azevedo, C.D.R.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel García, Sara
  • Carrión Burguete, José Vicente
  • Cebrian, S.
  • Conde, C.A.N.
  • Diaz, J.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] A new method to tag the barium daughter in the double-beta decay of Xe-136 is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba++) resolution at a transparent scanning surface is demonstrated. A single-step photobleach confirms the single ion interpretation. Individual ions are localized with superresolution (similar to 2 nm), and detected with a statistical significance of 12.9 sigma over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double-beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers., NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Advanced Grant No. 339787-NEXT, the Ministerio de Economia y Competitividad of Spain under Grants No. FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398, the Generalitat Valenciana (GVA) of Spain under Grant No. PROMETEO/2016/120, the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008, the U.S. Department of Energy under Contracts No. DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and No. DE-FG02-13ER42020 (Texas A&M) and No. DE-SC0017721 (University of Texas at Arlington), and the University of Texas at Arlington.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Demonstration of the event identification capabilities of the NEXT-White detector

  • Ferrario, Paola
  • Benlloch-Rodríguez, J.M.
  • Díaz López, G.
  • Hernando Morata, J.A.
  • Kekic, M.
  • Renner, J.
  • Usón, A.
  • Gómez-Cadenas, J.J.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a 228Th calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of 71.6 ± 1.5 stat ± 0.3 sys% for a background acceptance of 20.6 ± 0.4 stat ± 0.3 sys% is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/FBD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Secondary scintillation yield of xenon with sub-percent levels of CO2 additive for rare-event detection

  • HENRIQUES, C.A.
  • Freitas, E.D.C.
  • Azevedo, C.D.R.
  • González-Díaz, D.
  • Mano, R.D.P.
  • Jorge, M.R.
  • Fernandes, L.M.P.
  • Monteiro, C.M.B.
  • Gómez-Cadenas, J.J.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel García, Sara
  • Carrión Burguete, José Vicente
  • Querol-Segura, Marc
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Xe-CO2 mixtures are important alternatives to pure xenon in Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification with applications in the important field of rare event detection such as directional dark matter, double electron capture and double beta decay detection. The addition of CO2 to pure xenon at the level of 0.05-0.1% can reduce significantly the scale of electron diffusion from 10 mm/root m to 2.5 mm/root m, with high impact on the discrimination of the events through pattern recognition of the topology of primary ionization trails. We have measured the electroluminescence (EL) yield of Xe-CO2 mixtures, with sub-percent CO2 concentrations. We demonstrate that the EL production is still high in these mixtures, 70% and 35% relative to that produced in pure xenon, for CO2 concentrations around 0.05% and 0.1%, respectively. The contribution of the statistical fluctuations in EL production to the energy resolution increases with increasing CO2 concentration, being smaller than the contribution of the Fano factor for concentrations below 0.1% CO2. (C) 2017 The Author. Published by Elsevier B.V., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the GVA of Spain under grant PROMETEO/2016/120; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A & the University of Texas at Arlington. C.A.O.H., E.D.C.F., C.M.B.M. and C.D.R.A. acknowledge FCT under grants PD/BD/105921/2014, SFRH/BPD/109180/2015, SFRH/BPD/76842/2011 and SFRH/BPD/79163/2011, respectively.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Sensitivity of the NEXT experiment to 124-Xe double electron capture

  • Martinez-Lema, G.
  • Martinez-Vara, M.
  • Sorel, M.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Borges, F. I. G. M.
  • Byrnes, N.
  • Carcel, S.
  • Carrión, J. V.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite di erent, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture has been predicted for a number of isotopes, but only observed in 78Kr, 130Ba and, recently, 124Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process. Here we report on the current sensitivity of the NEXT-White detector to 124Xe 2 ECEC and on the extrapolation to NEXT-100. Using simulated data for the 2 ECEC signal and real data from NEXT-White operated with 124Xe-depleted gas as background, we de ne an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124Xe and for a 5-year run, a sensitivity to the two-neutroni double electron capture half-life of 6x10exp22 years (at 90% con dence level) or better can be reached., The NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment

  • Cebrian, S.
  • Perez, J.
  • Bandac, I.
  • Labarga, L.
  • Alvarez, V.
  • Barrado, A. I.
  • Bettini, A.
  • Borges, F. I. G. M.
  • Camargo, M.
  • Carcel, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Conde, E.
  • Dafni, T Diaz, J.
  • Fernandes, L. M. P.
  • Fernandez, M.
  • Ferrario, P.
  • Ferreira, A. L.
  • Freitas, E. D. C.
  • Gehman, V. M.
  • Goldschmidt, A.
  • Gomez-Cadenas, J. J.
  • Gonzalez-Diaz, D.
  • Gutierrez, R. M.
  • Hauptman, J.
  • Hernando Morata, J. A.
  • Herrera, D. C.
  • Irastorza, I. G.
  • Laing, A.
  • Liubarsky, I.
  • Lopez-March, N.
  • Lorca, D.
  • Losada, M.
  • Luzon, G.
  • Marí Peláez, Antonio
  • Martin-Albo, J.
  • Martinez, A.
  • Martinez-Lema, G.
  • Miller, T.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C. M. B.
  • Moutinho, L. M.
  • Munoz Vidal, J.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C. A. B.
  • Ortiz de Solorzano, A.
  • Pérez Aparicio, José Luis
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodriguez, J.
  • Santos, F. P.
  • dos Santos, J. M. F.
  • Serra, L.
  • Shuman, D.
  • Simon, A.
  • Sofka, C.
  • Sorel, M.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J. F. C. A.
  • Villar, J. A.
  • Webb, R. C.
  • White, J. T.
  • Yahlali, N.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
The Neutrino Experiment with a Xenon Time-Projection Chamber (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radio-purity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radio pure tracking plane, in direct contact with the gas detector medium, was a challenge since the needed components have typically activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper and silicon photomultipliers., We deeply acknowledge John Murphy and Carl Jackson from SensL Technologies Ltd for their efficient collaboration in the analysis of SiPMs. We very much thank also Vicenzo Mancini from SOMACIS company for the care in the development of radiopure kapton PCBs. Special thanks are due to LSC directorate and staff for their strong support for performing the measurements at the LSC Radiopurity Service. The NEXT Collaboration acknowledges funding support from the following agencies and institutions: the European Research Council under the Advanced Grant 339787-NEXT and the T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; the Spanish Ministerio de Economia y Competitividad under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04, and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences of the US DoE under Contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, Projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

  • Fernandes, A.F.M.
  • Henriques, C.A.O.
  • Mano, R.D.P.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Silva, P.A.O.C.
  • Gómez-Cadenas, J.J.
  • Freitas, E.D.C.
  • Fernandes, L.M.P.
  • Monteiro, C.M.B.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Bailey, K.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the EL region, the EL yield is lowered by similar to 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economa y Competitividad of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Mara de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015; the U.S. Department of Energy under contracts number DEAC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A& M) and DE-SC0019223/DESC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

An improved measurement of electron-ion recombination in high-pressure xenon gas

  • Serra, L.
  • Sorel, M.
  • Alvarez, V.
  • Borges, F. I. G.
  • Camargo, M.
  • Carcel, S.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Dafni, T.
  • Diaz, J.
  • Marí Romero, Antonio Francisco
  • Pérez Aparicio, José Luis
  • Querol Galve, Marcos
  • Webb, Rachel
  • Yahlali Haddou, Nadia
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
We report on results obtained with the NEXT-DEMO prototype of the NEXT-100 high-pressure xenon gas time projection chamber (TPC), exposed to an alpha decay calibration source. Compared to our previous measurements with alpha particles, an upgraded detector and improved analysis techniques have been used. We measure event-by-event correlated fluctuations between ionization and scintillation due to electron-ion recombination in the gas, with correlation coeffcients between -0.80 and -0.56 depending on the drift field conditions. By combining the two signals, we obtain a 2.8% FWHM energy resolution for 5.49 MeV alpha particles and a measurement of the optical gain of the electroluminescent TPC. The improved energy resolution also allows us to measure the specific activity of the radon in the gas due to natural impurities. Finally, we measure the average ratio of excited to ionized atoms produced in the xenon gas by alpha particles to be 0:561 0:045, translating into an average energy to produce a primary scintillation photon ofWex = (39:2 3:2) eV., This work was supported by the following agencies and institutions: the European Research Council under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04 and FIS2012-37947-C04; the Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Sensitivity of a tonne-scale NEXT detector for neutrinoless double-beta decay searches

  • Adams, C.
  • Alvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Borges, F. I. G. M.
  • Byrnes, N.
  • Carcel, S.
  • Carrión, J.V.
  • Cebrian, S.
  • Church, E.
  • Conde, C. A. N.
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta (0 nu beta beta) decay of Xe-136 using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of 0 nu beta beta decay better than 10(27) years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM2016-0692; the Generalitat Valenciana of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under grants 877040 and 877041; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges support from the Ramon y Cajal program (Spain) under contract number RYC-2015-18820. JM-A acknowledges support from Fundacion Bancaria la Caixa (ID 100010434), grant code LCF/BQ/PI19/11690012, and from the Plan GenT program of the Generalitat Valenciana, grant code CIDEGENT/2019/049. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Neutral Bremsstrahlung Emission in Xenon Unveiled

  • Henriques, C.A.O.
  • Amedo, P.
  • Teixeira, J. M. R.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Para, A.
  • Martín-Albo,J.
  • Saa Hernandez, A.
  • Gómez-Cadenas, J. J.
  • Nygren, D. R.
  • Monteiro, C.M.B.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Lopez-March, N.
  • Rodríguez, J.
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White time projection chamber (TPC) and a dedicated setup. Detailed comparison with first-principle calculations allows us to assign this scintillation mechanism to neutral bremsstrahlung (NBrS), a process that is postulated to exist in xenon that has been largely overlooked., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Advanced Grant No. 339787-NEXT; the European Unions Framework Program for Research and Innovation Horizon 2020 (20142020) under Grant Agreements No. 674896, No. 690575, and No. 740055; the Ministerio de Economa y Competitividad and the Ministerio de Ciencia, Innovacin y Universidades of Spain under Grants No. FIS2014-53371-C04 and No. RTI2018-095979, the Severo Ochoa Program Grants No. SEV-2014-0398 and No. CEX2018-000867-S, and the Mara de Maeztu Program MDM-2016-0692; the Generalitat Valenciana under Grants No. PROMETEO/2016/120 and No. SEJI/2017/011; the Portuguese FCT under Project No. PTDC/FIS-NUC/3933/2021 and under Project No. UIDP/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under Contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), No. DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), No. DE-FG02-13ER42020 (Texas A&M), and No. DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington (USA). D. G.-D. acknowledges Ramon y Cajal program (Spain) under Contract No. RYC- 2015-18820. J. M.-A. acknowledges support from Fundacin Bancaria la Caixa (ID 100010434), Grant No. LCF/BQ/PI19/11690012. We would like to thank Lorenzo Muniz for insightful discussions on the subtleties of electron transport in gases.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Radiogenic backgrounds in the NEXT double beta decay experiment

  • Novella, P.
  • Palmeiro, B.
  • Sorel, M.
  • Usón, A.
  • Ferrario, P.
  • Gómez-Cadenas, J. J.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Benlloch-Rodríguez, J. M.
  • Borges, F. I. G. M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity- induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterraneo de Canfranc with xenon depleted in Xe-136 are analyzed to derive a total background rate of (0.84 +/- 0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT collaboration. A spectral fit to this model yields the specific contributions of Co-60, K-40, Bi-214 and Tl-208 to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25 +/- 0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5 sigma after 1 year of data taking. The background measurement in a Q(beta beta)+/- 100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75 +/- 0.12) events., The NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The front-end electronics for the 1.8-kchannel SiPM tracking plane in the NEW detector

  • Rodríguez, Javier
  • Lorca, D.
  • Monrabal, F.
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Esteve Bosch, Raul|||0000-0002-1289-6938
[EN] NEW is the first phase of NEXT-100 experiment, an experiment aimed at searching for neutrinoless double-beta decay. NEXT technology combines an excellent energy resolution with tracking capabilities thanks to a combination of optical sensors, PMTs for the energy measurement and SiPMs for topology reconstruction. Those two tools result in one of the highest background rejection potentials in the field. This work describes the tracking plane that will be constructed for the NEW detector which consists of close to 1800 sensors with a 1-cm pitch arranged in twenty- eight 64-SiPM boards. Then it focuses in the development of the electronics needed to read the 1800 channels with a front-end board that includes per-channel differential transimpedance input amplifier, gated integrator, automatic offset voltage compensation and 12-bit ADC. Finally, a de- scription of how the FPGA buffers data, carries out zero suppression and sends data to the DAQ interface using CERN RD-51 SRS s DTCC link specification complements the description of the electronics of the NEW detector tracking plane., The authors would like to acknowledge the collaboration of the membership of the NEXT experiment. The European Commision under the European Research Council 2013 Advanced Grant 339787 - NEXT, the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04 and FIS2012-37947-C04-04 (also co-financed by FEDER). The Director, Office of Science, Office of Basic Energy Sciences, of the US Department of Energy under contract no. DE-AC02-05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm

  • Gonzalez Diaz, Diego
  • Borges, F. I. G.
  • Camargo, M.
  • Carcel, S.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Dafni, T.
  • Fernandes, L. M. P.
  • Pérez Aparicio, José Luis
  • Rodríguez Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and gamma-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in similar to 1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3 +/- 0.13 mm-sigma (longitudinal), 0.95 +/- 0.20 mm-sigma (transverse) along 1 m drift) besides forming a convenient Penning-Fluorescent' mixture. The TPC, that houses 1.1 kg of gas in its fiducial volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8 mm x 8 mm x 1.2 mm for approximately 10 cm/MeV-long electron tracks. Resolution in energy (epsilon) at full width half maximum (R) inside the fiducial volume ranged from R = 14.6% (30 keV) to R = 4.6% (1.275 MeV). This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the neutrino-less double beta decay (beta beta 0 nu) in Xe-136, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks. In particular, the obtained energy resolution has been decomposed in its various contributions and improvements towards achieving the R =1.4%root MeV/epsilon levels obtained in small sensors are discussed, The NEXT collaboration acknowledges funding support from the following agencies and institutions: European Research Council under Advanced Grant 339787-NEXT and Starting Grant 240054-TREX, Spanish Ministerio de Economia y Competitividad under grants Consolider-Ingenio 2010 CSD2008-0037 (CUP) and CSD2007-00042 (CPAN), contracts FPA2008-03456 and FPA2009-13697; Portuguese Fundacao para a Ciencia e a Tecnologia; European FEDER under grant PPTDC/FIS/103860/2008; US Department Of Energy under contract DE-AC02-05CH11231.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Sensitivity of NEXT-100 to neutrinoless double beta decay

  • Martín-Albo, J.
  • Muñoz Vidal, J.
  • Ferrario, P.
  • Nebot-Guinot, M.
  • Gomez-Cadenas, J. J.
  • Azevedo, C.D.R.
  • Borges, F.I.G.
  • Carcel, S.
  • Querol, M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta (0¿ßß) decay of 136Xe. The detector possesses two features of great value for 0¿ßß searches: energy resolution better than 1% FWHM at the Q value of 136Xe and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most 4 × 10¿4 counts keV¿1 kg¿1 yr¿1. Accordingly, the detector will reach a sensitivity to the 0¿ßß-decay half-life of 2.8 × 1025 years (90% CL) for an exposure of 100 kg·year, or 6.0 × 1025 years after a run of 3 effective years., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Econom¿ıa y Competitividad of Spain under grants CONSOLIDERIngenio 2010 CSD2008-0037 (CUP), FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A&M); and the University of Texas at Arlington. We thank Joshua B. Albert for useful discussions regarding the cosmogenic backgrounds.
Addi. Archivo Digital para la Docencia y la Investigación
Publicación Artículo científico (JournalArticle)

Fluorescent bicolour sensor for low-background neutrinoless double β decay experiments

  • Rivilla de la Cruz, Iván
  • Aparicio Gil, Borja
  • Bueno, Juan M.
  • Casanova Casas, David
  • Tonnelé, Claire
  • Freixa Fernández, Zoraida
  • Herrero Gómez, Pablo
  • Rogero Blanco, Celia
  • Miranda, José I.
  • Martínez Ojeda, Rosa M.
  • Monrabal, Francesc
  • Olave Fernández, Beñat
  • Schäfer, Thomas
  • Artal, Pablo
  • Nygren, David
  • Cossío Mora, Fernando Pedro
  • Gómez Cadenas, Juan J.
Observation of the neutrinoless double β decay is the only practical way to establish that neutrinos are their own antiparticles1. Because of the small masses of neutrinos, the lifetime of neutrinoless double β decay is expected to be at least ten orders of magnitude greater than the typical lifetimes of natural radioactive chains, which can mimic the experimental signature of neutrinoless double β decay2. The most robust identification of neutrinoless double β decay requires the definition of a signature signal—such as the observation of the daughter atom in the decay—that cannot be generated by radioactive backgrounds, as well as excellent energy resolution. In particular, the neutrinoless double β decay of 136Xe could be established by detecting the daughter atom, 136Ba2+, in its doubly ionized state3,4,5,6,7,8. Here we demonstrate an important step towards a ‘barium-tagging’ experiment, which identifies double β decay through the detection of a single Ba2+ ion. We propose a fluorescent bicolour indicator as the core of a sensor that can detect single Ba2+ ions in a high-pressure xenon gas detector. In a sensor made of a monolayer of such indicators, the Ba2+ dication would be captured by one of the molecules and generate a Ba2+-coordinated species with distinct photophysical properties. The presence of such a single Ba2+-coordinated indicator would be revealed by its response to repeated interrogation with a laser system, enabling the development of a sensor able to detect single Ba2+ ions in high-pressure xenon gas detectors for barium-tagging experiments., We acknowledge support from the following agencies and institutions: the European Research Council (ERC) under Advanced Grant 339787-NEXT; the Ministry of Science and Innovation of Spain and FEDER under grants FIS2014-53371-C04, FIS2016-76163-R, MAT2016-78293-C6-5-R, MINECO/FEDER CT2016-80955-P, CTQ2016-80375-P and CTQ2014-51912-REDC; Interred PCTEFA V-A Spain/France/Andorra Program (EFA 194/16/TNSI); the Basque Government (GV/EJ) under grants IT-1346-19 and IT-1180-19; and Agencia de Ciencia y Tecnología de la Región de Murcia (19897/GERM/15).
Addi. Archivo Digital para la Docencia y la Investigación
Publicación Artículo científico (JournalArticle)

Boosting background suppression in the NEXT experiment through Richardson-Lucy deconvolution

  • The NEXT collaboration
  • Almazán, H.
  • Aparicio Gil, Borja
  • Aranburu Leiva, Ane Izaskun
  • Benlloch-Rodríguez, J.M.
  • Cossío Mora, Fernando Pedro
  • Ferrario, P.
  • Generowicz, J.
  • Gómez Cadenas, Juan J.
  • Herrero, P.
  • Martínez-Vara, M.
  • Monrabal, Francesc
  • Oblak, E.
  • Odriozola Gimeno, Mikel
  • Ripoll, L.
  • Rivilla de la Cruz, Iván
  • Rogero Blanco, Celia
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • Dos Santos, J.M.F.
  • Sorel, M.
  • Stanford, C.
  • Teixeira, J.M.R.
  • Thapa, P.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Vuong, T.T.
  • Webb, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
Next-generation neutrinoless double beta decay experiments aim for half-life sensitivities of similar to 10(27) yr, requiring suppressing backgrounds to < 1 count/tonne/yr. For this, any extra background rejection handle, beyond excellent energy resolution and the use of extremely radiopure materials, is of utmost importance. The NEXT experiment exploits differences in the spatial ionization patterns of double beta decay and single-electron events to discriminate signal from background. While the former display two Bragg peak dense ionization regions at the opposite ends of the track, the latter typically have only one such feature. Thus, comparing the energies at the track extremes provides an additional rejection tool. The unique combination of the topology-based background discrimination and excellent energy resolution (1% FWHM at the Q-value of the decay) is the distinguishing feature of NEXT. Previous studies demonstrated a topological background rejection factor of 5 when reconstructing electron-positron pairs in the Tl-208 1.6 MeV double escape peak (with Compton events as background), recorded in the NEXT-White demonstrator at the Laboratorio Subterraneo de Canfranc, with 72% signal efficiency. This was recently improved through the use of a deep convolutional neural network to yield a background rejection factor of similar to 10 with 65% signal efficiency. Here, we present a new reconstruction method, based on the Richardson-Lucy deconvolution algorithm, which allows reversing the blurring induced by electron diffusion and electroluminescence light production in the NEXT TPC. The new method yields highly refined 3D images of reconstructed events, and, as a result, significantly improves the topological background discrimination. When applied to real-data 1.6 MeV e(-)e(+) pairs, it leads to a background rejection factor of 27 at 57% signal efficiency., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM-2016-0692; the Generalitat Valenciana under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); the University of Texas at Arlington (U.S.A.); and the Pazy Foundation (Israel) under grants 877040 and 877041. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. JM-A acknowledges support from Fundacion Bancaria "la Caixa" (ID 100010434), grant code LCF/BQ/PI19/11690012. AS acknowledges support from the Kreitman School of Advanced Graduate Studies at Ben-Gurion University. Document
Biblos-e Archivo. Repositorio Institucional de la UAM
Publicación Artículo científico (JournalArticle)

Radon and material radiopurity assessment for the NEXT double beta decay experiment

  • Cebrián, S.
  • Pérez, J.
  • Labarga Echeverría, Luis Alfonso
Artículo escrito por un elevado número de autores, solo se referencian el que aparece en primer lugar, el nombre del grupo de colaboración, si le hubiere, y los autores pertenecientes a la UAM, The ”Neutrino Experiment with a Xenon TPC” (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in 136Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low backgroundgermanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too, The NEXT Collaboration acknowledges funding support from the following agencies and institutions: the European Research Council under the Advanced Grant 339787-NEXT and the T-REX Starting Grant ref. ERC-2009-StG-240054 of the IDEAS program of the 7th EU Framework Program; the Spanish Ministerio de Economía y Competitividad under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FPA2009-13697-C04-04, and FIS2012-37947- C04; the Director, Office of Science, Office of Basic Energy Sciences of the US DoE under Contract no. DE-AC02- 05CH11231; and the Portuguese FCT and FEDER through the program COMPETE, Projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009. S. Cebrián acknowledges the support from the University of Zaragoza (Convocatoria propia de proyectos de investigación para Jóvenes Investigadores 2014). Special thanks are due to LSC directorate and staff for their strong support for performing the measurements at the LSC Radiopurity Service
Dipòsit Digital de la UB
Publicación Artículo científico (JournalArticle)

Conditions for statistical determination of the neutrino mass spectrum in radiative emission of neutrino pairs in atoms

  • Song, Ningqiang
  • Boyero Garcia, R.
  • Gomez-Cadenas, J.J.
  • González García, Ma. Concepción
  • Peralta Conde, A.
  • Taron i Roca, Josep
The photon spectrum in macrocoherent atomic deexcitation via radiative emission of neutrino pairs has been proposed as a sensitive probe of the neutrino mass spectrum, capable of competing with conventional neutrino experiments. In this paper we revisit this interesting proposal in order to quantify the requirements for statistical determination of some of the properties of the neutrino spectrum, in particular, the neutrino mass scale and the mass ordering. Our results are shown as the product of the experimental lifetime, the target volume, and the number density of atoms which have to be set in a coherence state with a given electric field in the target, needed for determination of these properties with a given confidence level.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Demonstration of the event identification capabilities of the NEXT-White detector

  • NEXT Collaboration
  • Álvarez Puerta, Vicente
  • Benlloch Rodríguez, José María
  • Botas, A.
  • Cárcel, Sara
  • Carrión, J. V.
  • Díaz Medina, José
  • Felkai, Ryan
  • Kekic, Marija
  • Laing, Andrew
  • López-March, Neus
  • Martínez Pérez, Alberto
  • Martinez-Lema, G.
  • Musti, M.
  • Muñoz Vidal, Javier
  • Nebot Guinot, Miquel
  • Novella, Pau
  • Palmeiro, Brais
  • Querol, Marc
  • Renner, Joshua
  • Rodríguez Samaniego, Javier
  • Romo Luque, Carmen
  • Simón, Ander
  • Sorel, Michel
  • Simón, Ander
  • Yahlali, Nadia
In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a Th calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of 71.6 ± 1.5 ± 0.3 % for a background acceptance of 20.6 ± 0.4 ± 0.3 % is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies. [Figure not available: see fulltext.]
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Energy calibration of the NEXT-White detector with 1% resolution near Q ββ of 136Xe

  • NEXT Collaboration
  • Álvarez Puerta, Vicente
  • Benlloch Rodríguez, José María
  • Botas, A.
  • Cárcel, Sara
  • Carrión, J. V.
  • Díaz Medina, José
  • Felkai, Ryan
  • Kekic, Marija
  • Laing, Andrew
  • López-March, Neus
  • Martínez Pérez, Alberto
  • Martinez-Lema, G.
  • Musti, M.
  • Muñoz Vidal, Javier
  • Nebot Guinot, Miquel
  • Novella, Pau
  • Palmeiro, Brais
  • Querol, Marc
  • Renner, Joshua
  • Rodríguez Samaniego, Javier
  • Romo Luque, Carmen
  • Simón, Ander
  • Sorel, Michel
  • Simón, Ander
  • Yahlali, Nadia
Excellent energy resolution is one of the primary advantages of electroluminescent high-pressure xenon TPCs. These detectors are promising tools in searching for rare physics events, such as neutrinoless double-beta decay (ββ0ν), which require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for ββ0ν searches. [Figure not available: see fulltext.]
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Radiogenic backgrounds in the NEXT double beta decay experiment

  • NEXT Collaboration
  • Álvarez Puerta, Vicente
  • Benlloch Rodríguez, José María
  • Botas, A.
  • Cárcel, Sara
  • Carrión, J. V.
  • Díaz Medina, José
  • Felkai, Ryan
  • Kekic, Marija
  • Laing, Andrew
  • López-March, Neus
  • Martínez Pérez, Alberto
  • Martinez-Lema, G.
  • Musti, M.
  • Muñoz Vidal, Javier
  • Nebot Guinot, Miquel
  • Novella, Pau
  • Palmeiro, Brais
  • Querol, Marc
  • Renner, Joshua
  • Rodríguez Samaniego, Javier
  • Romo Luque, Carmen
  • Simón, Ander
  • Sorel, Michel
  • Simón, Ander
  • Yahlali, Nadia
Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity- induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterráneo de Canfranc with xenon depleted in Xe are analyzed to derive a total background rate of (0.84±0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT collaboration. A spectral fit to this model yields the specific contributions of Co, K, Bi and Tl to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25±0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5σ after 1 year of data taking. The background measurement in a Q±100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75±0.12) events. [Figure not available: see fulltext.].
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Electron drift and longitudinal diffusion in high pressure xenon-helium gas mixtures

  • NEXT Collaboration
  • Álvarez Puerta, Vicente
  • Benlloch Rodríguez, José María
  • Botas, A.
  • Cárcel, Sara
  • Carrión, J. V.
  • Díaz Medina, José
  • Felkai, Ryan
  • Kekic, Marija
  • Laing, Andrew
  • López-March, Neus
  • Martínez Pérez, Alberto
  • Martinez-Lema, G.
  • Musti, M.
  • Muñoz Vidal, Javier
  • Nebot Guinot, Miquel
  • Novella, Pau
  • Palmeiro, Brais
  • Querol, Marc
  • Renner, Joshua
  • Rodríguez Samaniego, Javier
  • Romo Luque, Carmen
  • Simón, Ander
  • Sorel, Michel
  • Simón, Ander
  • Yahlali, Nadia
We report new measurements of the drift velocity and longitudinal diffusion coefficients of electrons in pure xenon gas and in xenon-helium gas mixtures at 1-9 bar and electric field strengths of 50-300 V/cm. In pure xenon we find excellent agreement with world data at all E/P, for both drift velocity and diffusion coefficients. However, a larger value of the longitudinal diffusion coefficient than theoretical predictions is found at low E/P in pure xenon, below the range of reduced fields usually probed by TPC experiments. A similar effect is observed in xenon-helium gas mixtures at somewhat larger E/P. Drift velocities in xenon-helium mixtures are found to be theoretically well predicted. Although longitudinal diffusion in xenon-helium mixtures is found to be larger than anticipated, extrapolation based on the measured longitudinal diffusion coefficients suggest that the use of helium additives to reduce transverse diffusion in xenon gas remains a promising prospect.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

The electronics of the energy plane of the NEXT-White detector

  • Álvarez Puerta, Vicente
  • Herrero Bosch, Vicente
  • Esteve, R.
  • Laing, Andrew
  • Rodríguez Samaniego, Javier
  • Querol, Marc
  • Monrabal, Francesc
  • Toledo, J.F.
  • Gómez Cadenas, Juan José
This paper describes the electronics of NEXT-White (NEW) detector PMT plane, a high pressure xenon TPC with electroluminescent amplification (HPXe-EL) currently operating at the Laboratorio Subterráneo de Canfranc (LSC) in Huesca, Spain. In NEXT-White the energy of the event is measured by a plane of photomultipliers (PMTs) located behind a transparent cathode. The PMTs are Hamamatsu R11410-10 chosen due to their low radioactivity. The electronics have been designed and implemented to fulfill strict requirements: an overall energy resolution below 1% and a radiopurity budget of 20 mBq unit in the chain of Bi. All the components and materials have been carefully screened to assure a low radioactivity level and at the same time meet the required front-end electronics specifications. In order to reduce low frequency noise effects and enhance detector safety a grounded cathode connection has been used for the PMTs. This implies an AC-coupled readout and baseline variations in the PMT signals. A detailed description of the electronics and a novel approach based on a digital baseline restoration to obtain a linear response and handle AC coupling effects is presented. The final PMT channel design has been characterized with linearity better than 0.4% and noise below 0.4mV.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

  • NEXT Collaboration
  • Fernandes, A.F.M.
  • Álvarez Puerta, Vicente
  • Benlloch Rodríguez, José María
  • Cárcel, Sara
  • Carrión, J. V.
  • Díaz Medina, José
  • Felkai, Ryan
  • Herrero-Gómez, P.
  • Kekic, Marija
  • López-March, Neus
  • Martinez-Lema, G.
  • Muñoz Vidal, Javier
  • Novella, Pau
  • Palmeiro, Brais
  • Querol, Marc
  • Renner, Joshua
  • Romo Luque, Carmen
  • Sorel, Michel
  • Simón, Ander
  • Yahlali, Nadia
High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe–He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the EL region, the EL yield is lowered by ∼ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures. [Figure not available: see fulltext.].
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Sensitivity of a tonne-scale NEXT detector for neutrinoless double-beta decay searches

  • Weiss-Babai, R.
  • Rogero, Celia
  • Cárcel, Sara
  • Carrión, J. V.
  • Díaz, J.
  • Felkai, R.
  • López-March, Neus
  • Martín-Albo, Justo
  • Martínez, Alejandro
  • Martínez-Vara, M.
  • Muñoz Vidal, J.
  • Novella, Pau
  • Palmeiro, Brais
  • Romo-Luque, Carmen
  • Sorel, Michel
  • Usón, A.
  • Yahlali, Nadia
  • Álvarez Puerta, Vicente
  • Ballester, F.
  • Esteve, Raúl
  • Herrero Bosch, Vicente
  • Mora, Francisco José
  • Rodríguez, J.
  • Toledo, J. F.
The NEXT collaboration: et al., The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta (0νββ) decay of 136Xe using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of 0νββ decay better than 1027 years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union’s Framework Programme for Research and Innovation Horizon 2020 (2014–2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economía y Competitividad and the Ministerio de Ciencia, Innovación y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the María de Maeztu Program MDM2016-0692; the Generalitat Valenciana of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under grants 877040 and 877041; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223 / DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges support from the Ramón y Cajal program (Spain) under contract number RYC-2015-18820. JM-A acknowledges support from Fundación Bancaria la Caixa (ID 100010434), grant code LCF/BQ/PI19/11690012, and from the Plan GenT program of the Generalitat Valenciana, grant code CIDEGENT/2019/049., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

The dynamics of ions on phased radio-frequency carpets in high pressure gases and application for barium tagging in xenon gas time projection chambers

  • Jones, B.J.P.
  • Álvarez Puerta, Vicente
  • Ballester, F.
  • Cárcel, Sara
  • Carrión, J. V.
  • Díaz, J.
  • Esteve, Raúl
  • Herrero-Gómez, P.
  • Herrero Bosch, Vicente
  • López-March, Neus
  • Martín-Albo, Justo
  • Martínez, Alejandro
  • Martínez-Vara, M.
  • Mora, Francisco José
  • Muñoz Vidal, J.
  • Novella, Pau
  • Palmeiro, Brais
  • Querol, Marc
  • Rodríguez, J.
  • Rogero, Celia
  • Romo-Luque, Carmen
  • Sorel, Michel
  • Toledo, J. F.
  • Usón, A.
  • Yahlali, Nadia
NEXT Collaboration: et al., Radio-frequency (RF) carpets with ultra-fine pitches are examined for ion transport in gases at atmospheric pressures and above. We develop new analytic and computational methods for modeling RF ion transport at densities where dynamics are strongly influenced by buffer gas collisions. An analytic description of levitating and sweeping forces from phased arrays is obtained, then thermodynamic and kinetic principles are used to calculate ion loss rates in the presence of collisions. This methodology is validated against detailed microscopic SIMION simulations. We then explore a parameter space of special interest for neutrinoless double beta decay experiments: transport of barium ions in xenon at pressures from 1 to 10 bar. Our computations account for molecular ion formation and pressure dependent mobility as well as finite temperature effects. We discuss the challenges associated with achieving suitable operating conditions, which lie beyond the capabilities of existing devices, using presently available or near-future manufacturing techniques., The University of Texas at Arlington NEXT group is supported by the Department of Energy, USA under Early Career Award number DE-SC0019054 (BJPJ), by Department of Energy, USA Award DE-SC0019223 (DRN), the National Science Foundation, USA under award number NSF CHE 2004111 (FWF), and the Robert A Welch Foundation, Y-2031-20200401 (FWF). The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union’s Framework Programme for Research and Innovation Horizon 2020 (2014–2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economía Competitividad and the Ministerio de Ciencia, Innovación Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the María de Maeztu Program MDM-2016-0692; from Fundacion Bancaria la Caixa (ID 100010434), grant code LCF/BQ/PI19/11690012; the Generalitat Valenciana of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under grants 877040 and 877041; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory, USA), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M). DGD acknowledges support from the Ramón y Cajal program (Spain) under contract number RYC-2015-18820. JM-A acknowledges support from Fundación Bancaria la Caixa (ID 100010434), grant code LCF/BQ/PI19/11690012, and from the Plan GenT program of the Generalitat Valenciana , grant code CIDEGENT/2019/049., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Sensitivity of NEXT-100 to neutrinoless double beta decay

  • The, NEXT collaboration
  • Martín-Albo, J.
  • Muñoz Vidal, J.
  • Ferrario, P.
  • Nebot-Guinot, M.
  • Gómez-Cadenas, J.J.
  • Álvarez, V.
  • Azevedo, C.D.R.
  • Borges, F.I.G.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Goldschmidt, A.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernando Morata, J.A.
  • Herrero, V.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • Liubarsky, I.
  • López-March, N.
  • Lorca, D.
  • Losada, M.
  • Martínez-Lema, G.
  • Martínez, A.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Novella, P.
  • Nygren, D.
  • Palmeiro, B.
  • Para, A.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
  • Yepes-Ramírez, H.
NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta (0¿ßß) decay of 136Xe. The detector possesses two features of great value for 0¿ßß searches: energy resolution better than 1% FWHM at the Q value of 136Xe and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most 4 × 10-4 counts keV-1 kg-1 yr-1. Accordingly, the detector will reach a sensitivity to the 0¿ßß-decay half-life of 2.8 × 1025 years (90% CL) for an exposure of 100 kg·year, or 6.0 × 1025 years after a run of 3 effective years.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment

  • Cebrián, S.
  • Pérez, J.
  • Bandac, I.
  • Labarga, L.
  • Álvarez, V.
  • Barrado, A.I.
  • Bettini, A.
  • Borges, F.I.G.M.
  • Camargo, M.
  • Cárcel, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Conde, E.
  • Dafni, T.
  • Díaz, J.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Fernández, M.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Morata, J.A.H.
  • Herrera, D.C.
  • Irastorza, I.G.
  • Laing, A.
  • Liubarsky, I.
  • López-March, N.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí, A.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • Miller, T.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Vidal, J.M.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Ortiz de Solórzano, A.
  • Aparicio, J.L.P.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Santos, F.P.
  • Santos, J.M.F.D.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.C.
  • White, J.T.
  • Yahlali, N.
The ``Neutrino Experiment with a Xenon Time-Projection Chamber'' (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterr'aneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8×10-4 counts keV-1 kg-1 y-1, have been identified.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The NEXT double beta decay experiment

  • A Laing on behalf of the NEXT collaboration
  • Cebrian, S
NEXT (Neutrino Experiment with a Xenon TPC) is a neutrinoless double- beta (ßß0¿) decay experiment at Laboratorio Subterra ´neo de Canfranc (LSC). It is an electroluminescent Time Projection Chamber filled with high pressure 136Xe gas with separated function capabilities for calorimetry and tracking. Energy resolution and background suppression are the two key features of any neutrinoless double beta decay experiment. NEXT has both good energy resolution (< 1% FWHM) and an extra handle for background identification provided by track reconstruction. We expect a background rate of 4 × 10-4 counts keV-1 kg-1 yr-1, and a sensitivity to the Majorana neutrino mass of between 80–160 meV (depending on NME) after a run of 3 effective years of the 100 kg scale NEXT-100 detector. The initial phase of NEXT-100, called NEW, is currently being commissioned at LSC. It will validate the NEXT background rate expectations and will make first measurements of the two neutrino ßß2¿ mode of 136Xe. Furthermore, the NEXT technique can be extrapolated to the tonne scale, thus allowing the full exploration of the inverted hierarchy of neutrino masses. These proceedings review NEXT R&D results, the status of detector commissioning at LSC and the NEXT physics case.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

First proof of topological signature in the high pressure xenon gas TPC with electroluminescence amplification for the NEXT experiment

  • Ferrario, P.
  • Laing, A.
  • López-March, N.
  • Gómez-Cadenas, J. J.
  • Álvarez, V.
  • Azevedo, C.D.R.
  • Borges, F.I.G.
  • Cárcel, S.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Dafni, T.
  • Díaz, J.
  • Diesburg, M.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Goldschmidt, A.
  • González-Díaz, D.
  • Gutiérrez, R. M.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernando Morata, J. A.
  • Irastorza, I.G.
  • Labarga, L.
  • Lebrun, P.
  • Liubarsky, I.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí, A.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • Miller, T.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Nebot-Guinot, M
  • Novella, P.
  • Nygren, D.
  • Para, A.
  • Pérez, J.
  • Pérez Aparicio, J. L.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Santos, F.P.
  • dos Santos, J. M. F.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
  • Yepes-Ramírez, H.
The NEXT experiment aims to observe the neutrinoless double beta decay of 136Xe in a high-pressure xenon gas TPC using electroluminescence (EL) to amplify the signal from ionization. One of the main advantages of this technology is the possibility to reconstruct the topology of events with energies close to Qßß. This paper presents the first demonstration that the topology provides extra handles to reject background events using data obtained with the NEXT-DEMO prototype. Single electrons resulting from the interactions of 22Na 1275 keV gammas and electron- positron pairs produced by conversions of gammas from the 228Th decay chain were used to represent the background and the signal in a double beta decay. These data were used to develop algorithms for the reconstruction of tracks and the identification of the energy deposited at the end-points, providing an extra background rejection factor of 24.3 ± 1.4 (stat.)%, while maintaining an efficiency of 66.7 ± 1.% for signal events.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The NEXT experiment

  • Gomez-Cadenas, J.J.
  • on behalf of the NEXT collaboration
NEXT (Neutrino Experiment with a Xenon TPC) is an experiment to search neutrinoless double beta decay processes (ßß0¿ßß0¿). The isotope chosen by NEXT is 136Xe. The NEXT technology is based in the use of time projection chambers operating at a typical pressure of 15 bar and using electroluminescence to amplify the signal (HPXe). The main advantages of the experimental technique are: a) excellent energy resolution; b) the ability to reconstruct the trajectory of the two electrons emitted in the decays, a unique feature of the HPXe which further contributes to the suppression of backgrounds; c) scalability to large masses; and d) the possibility to reduce the background to negligible levels thanks to the barium tagging technology (BaTa). The NEXT roadmap was designed in four stages: i) Demonstration of the HPXe technology with prototypes deploying a mass of natural xenon in the range of 1 kg; ii) Characterisation of the backgrounds to the ßß0¿ßß0¿ signal and measurement of the ßß2¿ßß2¿ signal with the NEW detector, deploying 10 kg of enriched xenon and operating at the LSC; iii) Search for ßß0¿ßß0¿ decays with the NEXT-100 detector, which deploys 100 kg of enriched xenon; iv) Search for ßß0¿ßß0¿ decays with the BEXT detector, which will deploy masses in the range of the ton and will introduce two additional handles, only possible in a HPXe: a) A magnetic field, capable of further enhancing the topological signal of NEXT; and b) barium-tagging (a technique pioneered by the EXO experiment which is also accessible to NEXT). The first stage of NEXT has been successfully completed during the period 2009–2013. The prototypes NEXT-DEMO (IFIC) and NEXT-DBDM (Berkeley) were built and operated for more than two years. These apparatuses have demonstrated the main features of the technology. The experiment is currently developing its second phase. The NEW detector is being constructed during 2014 and will operate in the LSC during 2015. The NEXT-100 detector will be built and commissioned during 2016 and 2017 and will start data taking in 2018. NEXT-100 could discover ßß0¿ßß0¿ processes if the period of the decay is equal or less than 6×10256×1025 year. The fourth phase of the experiment (BEXT) could start in 2020.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Backgrounds and sensitivity of the NEXT double beta decay experiment

  • Nebot-Guinot, M.
  • Ferrario, P.
  • Martín-Albo, J.
  • Muñoz Vidal, J.
  • Gómez-Cadena, J.J.
  • on behalf of the NEXT Collaboration
NEXT (Neutrino Experiment with a Xenon TPC) is a neutrinoless double-beta (ßß0¿ßß0¿) decay experiment that will operate at the Canfranc Underground Laboratory (LSC). It is an electroluminescent high-pressure gaseous xenon Time Projection Chamber (TPC) with separate read-out planes for calorimetry and tracking. Energy resolution and background suppression are the two key features of any neutrinoless double beta decay experiment. NEXT has both good energy resolution (<1% FWHM) at the Q value of 136Xe and an extra handle for background identification provided by track reconstruction. With the background model of NEXT, based on the detector simulation and the evaluation of the detector radiopurity, we can determine the sensitivity to a measurement of the ßß2¿ßß2¿ mode in NEW and to a ßß0¿ßß0¿ search in NEXT100. In this way we can predict the background rate of 5×10-4 counts/(keV kg yr)5×10-4 counts/(keV kg yr), and a sensitivity to the Majorana neutrino mass down to 100 meV after a 5-years run of NEXT100.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Background rejection in NEXT using deep neural networks

  • Renner, J.
  • Farbin, A.
  • Vidal, J.M.
  • Benlloch-Rodríguez, J.M.
  • Botas, A.
  • Ferrario, P.
  • Gómez-Cadenas, J.J.
  • Álvarez, V.
  • Azevedo, C.D.R.
  • Borges, F.I.G.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Goldschmidt, A.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Morata, J.A.H.
  • Herrero, V.
  • Jones, B.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • Liubarsky, I.
  • López-March, N.
  • Lorca, D.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Ripoll, L.
  • Rodríguez, J.
  • Santos, F.P.
  • Dos Santos, J.M.F.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • White, J.
  • Webb, R.
  • Yahlali, N.
  • Yepes-Ramírez, H.
We investigate the potential of using deep learning techniques to reject background events in searches for neutrinoless double beta decay with high pressure xenon time projection chambers capable of detailed track reconstruction. The differences in the topological signatures of background and signal events can be learned by deep neural networks via training over many thousands of events. These networks can then be used to classify further events as signal or background, providing an additional background rejection factor at an acceptable loss of efficiency. The networks trained in this study performed better than previous methods developed based on the use of the same topological signatures by a factor of 1.2 to 1.6, and there is potential for further improvement.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Secondary scintillation yield of xenon with sub-percent levels of CO2 additive for rare-event detection

  • Henriques, C.A.O.
  • Freitas, E.D.C.
  • Azevedo, C.D.R.
  • González-Díaz, D.
  • Mano, R.D.P.
  • Jorge, M.R.
  • Fernandes, L.M.P.
  • Monteiro, C.M.B.
  • Gómez-Cadenas, J.J.
  • Álvarez, V.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel, S.
  • Carríon, J.V.
  • Cebrían, S.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Esteve, R.
  • Felkai, R.
  • Ferrario, P.
  • Ferreira, A.L.
  • Goldschmidt, A.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernandez, A.I.
  • Hernando Morata, J.A.
  • Herrero, V.
  • Jones, B.J.P.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • Liubarsky, I.
  • López-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • McDonald, A.D.
  • Monrabal, F.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Musti, M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Rogers, L.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
Xe–CO2 mixtures are important alternatives to pure xenon in Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification with applications in the important field of rare event detection such as directional dark matter, double electron capture and double beta decay detection. The addition of CO2 to pure xenon at the level of 0.05–0.1% can reduce significantly the scale of electron diffusion from 10 mm/m to 2.5 mm/m, with high impact on the discrimination efficiency of the events through pattern recognition of the topology of primary ionization trails. We have measured the electroluminescence (EL) yield of Xe–CO2 mixtures, with sub-percent CO2 concentrations. We demonstrate that the EL production is still high in these mixtures, 70% and 35% relative to that produced in pure xenon, for CO2 concentrations around 0.05% and 0.1%, respectively. The contribution of the statistical fluctuations in EL production to the energy resolution increases with increasing CO2 concentration, being smaller than the contribution of the Fano factor for concentrations below 0.1% CO2.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Demonstration of Single-Barium-Ion Sensitivity for Neutrinoless Double-Beta Decay Using Single-Molecule Fluorescence Imaging

  • McDonald, A.D.
  • Jones, B.J.P.
  • Nygren, D.R.
  • Adams, C.
  • Álvarez, V.
  • Azevedo, C.D.R.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Guenette, R.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernandez, A.I.
  • Hernando Morata, J.A.
  • Herrero, V.
  • Johnston, S.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • Liubarsky, I.
  • López-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Musti, M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Repond, J.
  • Renner, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez, J.
  • Rogers, L.
  • Santos, F.P.
  • Dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
A new method to tag the barium daughter in the double-beta decay of Xe136 is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba++) resolution at a transparent scanning surface is demonstrated. A single-step photobleach confirms the single ion interpretation. Individual ions are localized with superresolution (~2 nm), and detected with a statistical significance of 12.9s over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double-beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Measurement of radon-induced backgrounds in the NEXT double beta decay experiment

  • Novella, P.
  • Palmeiro, B.
  • Simón, A.
  • Sorel, M.
  • Adams, C.
  • Ferrario, P.
  • Martínez-Lema, G.
  • Monrabal, F.
  • Zuzel, G.
  • Gómez-Cadenas, J.J.
  • Álvarez, V.
  • Arazi, L.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Goldschmidt, A.
  • González-Díaz, D.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernandez, A.I.
  • Hernando Morata, J.A.
  • Herrero, V.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martíin-Albo, J.
  • Martínez, A.
  • McDonald, A.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Musti, M.
  • Nebot-Guinot, M.
  • Nygren, D.R.
  • Para, A.
  • Pérez, J.
  • Psihas, F.
  • Querol, M.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez, J.
  • Rogers, L.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Sofka, C.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
  • The, NEXT, collaboration
The measurement of the internal 222Rn activity in the NEXT-White detector during the so-called Run-II period with 136Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by 222Rn and its alpha-emitting progeny. The specific activity is measured to be (38.1 ± 2.2 (stat.) ± 5.9 (syst.)) mBq/m3. Radon-induced electrons have also been characterized from the decay of the 214Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.1 counts/yr in the neutrinoless double beta decay sample.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The NEXT White (NEW) detector

  • Monrabal, F.
  • Gomez-Cadenas, J.J.
  • Toledo, J.F.
  • Laing, A.
  • Alvarez, V.
  • Benlloch-Rodriguez, J.M.
  • Carcel, S.
  • Carrion, J.
  • Esteve, R.
  • Felkai, R.
  • Herrero, V.
  • Martinez, A.
  • Musti, M.
  • Ouero, M.
  • Rodriguez, J.
  • Simon, A.
  • Sofka, C.
  • Torrent, J.
  • Webb, R.
  • White, J.T.
  • Adams, C.
  • Arazi, L.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cebrian, S.
  • Conde, C.A.N.
  • Diaz, J.
  • Diesburg, M.
  • Escada, J.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferrario, I.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Goldschmidt, A.
  • Gonzalez-Daaz, D.
  • Guenette, R.
  • Gutierrez, R.M.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernandez, A.I.
  • Morata, J.A.H.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Lebrun, P.
  • Lopez-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martin-Albo, J.
  • Martinez-Lema, G.
  • McDonald, A.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Vidal, J.M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Perez, J.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rogers, L.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Sorel, M.
  • Stiegler, T.
  • Veloso, J.F.C.A.
  • Yahlali, N.
Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT-White apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector for Xe-136 beta beta 0 nu decay searches, scheduled to start operations in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2016 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. This paper describes the detector and associated infrastructures, as well as the main aspects of its initial operation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Electroluminescence TPCs at the thermal diffusion limit

  • Henriques, C.A.O.
  • Monteiro, C.M.B.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Freitas, E.D.C.
  • Mano, R.D.P.
  • Jorge, M.R.
  • Fernandes, A.F.M.
  • Gómez-Cadenas, J.J.
  • Fernandes, L.M.P.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Ferrario, P.
  • Ferreira, A.L.
  • Generowicz, J.
  • Goldschmidt, A.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Hafidi, K.
  • Hauptman, J.
  • Hernandez, A.I.
  • Hernando Morata, J.A.
  • Herrero, V.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • McDonald, A.
  • Monrabal, F.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Musti, M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Psihas, F.
  • Querol, M.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez, J.
  • Rogers, L.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the 136Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO2, CH4 and CF4) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/m for pure xenon down to 2.5 mm/m using additive concentrations of about 0.05%, 0.2% and 0.02% for CO2, CH4 and CF4, respectively. Our results show that CF4 admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH4 presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO2 and CH4 show potential as molecular additives in a large xenon TPC. While CO2 has some operational constraints, making it difficult to be used in a large TPC, CH4 shows the best performance and stability as molecular additive to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%, which is only slightly worse than the one obtained for pure xenon. We demonstrate the possibility to have an electroluminescence TPC operating very close to the thermal diffusion limit without jeopardizing the TPC performance, if CO2 or CH4 are chosen as additives.[Figure not available: see fulltext.]
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Microscopic simulation of xenon-based optical TPCs in the presence of molecular additives

  • Azevedo, C.D.R.
  • González-Díaz, D.
  • Biagi, S.F.
  • Oliveira, C.A.B.
  • Henriques, C.A.O.
  • Escada, J.
  • Monrabal, F.
  • Gómez-Cadenas, J.J.
  • Álvarez, V.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Goldschmidt, A.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernandez, A.I.
  • Morata, J.A.H.
  • Herrero, V.
  • Jones, B.J.P.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • Liubarsky, I.
  • Lopez-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • McDonald, A.D.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Vidal, J.M.
  • Musti, M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Rogers, L.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
We introduce a simulation framework for the transport of high and low energy electrons in xenon-based optical time projection chambers (OTPCs). The simulation relies on elementary cross sections (electron–atom and electron–molecule) and incorporates, in order to compute the gas scintillation, the reaction/quenching rates (atom–atom and atom–molecule) of the first 41 excited states of xenon and the relevant associated excimers, together with their radiative cascade. The results compare positively with observations made in pure xenon and its mixtures with CO2 and CF4 in a range of pressures from 0.1 to 10 bar. This work sheds some light on the elementary processes responsible for the primary and secondary xenon-scintillation mechanisms in the presence of additives, that are of interest to the OTPC technology.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Radiogenic backgrounds in the NEXT double beta decay experiment

  • Novella P.
  • Palmeiro B.
  • Sorel M.
  • Usón A.
  • Ferrario P.
  • Gómez-Cadenas J.J.
  • Adams C.
  • Álvarez V.
  • Arazi L.
  • Arnquist I.J.
  • Azevedo C.D.R.
  • Bailey K.
  • Ballester F.
  • Benlloch-Rodríguez J.M.
  • Borges F.I.G.M.
  • Byrnes N.
  • Cárcel S.
  • Carrión J.V.
  • Cebrían S.
  • Church E.
  • Conde C.A.N.
  • Contreras T.
  • Díaz G.
  • Díaz J.
  • Diesburg M.
  • Escada J.
  • Esteve R.
  • Felkai R.
  • Fernandes A.F.M.
  • Fernandes L.M.P.
  • Ferreira A.L.
  • Freitas E.D.C.
  • Generowicz J.
  • Ghosh S.
  • Goldschmidt A.
  • Gonzalez-Díaz D.
  • Guenette R.
  • Gutiérrez R.M.
  • Haefner J.
  • Hafidi K.
  • Hauptman J.
  • Henriques C.A.O.
  • Hernando Morata J.A.
  • Herrero P.
  • Herrero V.
  • Ifergan Y.
  • Johnston S.
  • Jones B.J.P.
  • Kekic M.
  • Labarga L.
  • Laing A.
  • Lebrun P.
  • López-March N.
  • Losada M.
  • Mano R.D.P.
  • Martín-Albo J.
  • Martínez A.
  • Martínez-Lema G.
  • McDonald A.D.
  • Monrabal F.
  • Monteiro C.M.B.
  • Mora F.J.
  • Muñoz Vidal J.
  • Nygren D.R.
  • Para A.
  • Pérez J.
  • Psihas F.
  • Querol M.
  • Renner J.
  • Repond J.
  • Riordan S.
  • Ripoll L.
  • Rodríguez García Y.
  • Rodríguez J.
  • Rogers L.
  • Romeo B.
  • Romo-Luque C.
  • Santos F.P.
  • dos Santos J.M.F.
  • Simón A.
  • Sofka C.
  • Stiegler T.
  • Toledo J.F.
  • Torrent J.
  • Veloso J.F.C.A.
  • Webb R.
  • Weiss-Babai R.
  • White J.T.
  • Woodruff K.
  • Yahlali N.
  • The NEXT collaboration
Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity- induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterráneo de Canfranc with xenon depleted in 136Xe are analyzed to derive a total background rate of (0.84±0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT collaboration. A spectral fit to this model yields the specific contributions of 60Co, 40K, 214Bi and 208Tl to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25±0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5s after 1 year of data taking. The background measurement in a Qßß±100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75±0.12) events.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Energy calibration of the NEXT-White detector with 1% resolution near Qßß of 136Xe

  • Renner, J.
  • Díaz López, G.
  • Ferrario, P.
  • Hernando Morata, J.A.
  • Kekic, M.
  • Martínez-Lema, G.
  • Monrabal, F.
  • Gómez-Cadenas, J.J.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • González-Díaz, D.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Jones, B.J.P.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martín-Albo, J.
  • Martínez, A.
  • McDonald, A.D.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Psihas, F.
  • Querol, M.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez García, Y.
  • Rodríguez, J.
  • Rogers, L.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
  • The NEXT collaboration
Excellent energy resolution is one of the primary advantages of electroluminescent high-pressure xenon TPCs. These detectors are promising tools in searching for rare physics events, such as neutrinoless double-beta decay (ßß0¿), which require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for ßß0¿ searches. [Figure not available: see fulltext.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Demonstration of the event identification capabilities of the NEXT-White detector

  • Ferrario P.
  • Benlloch-Rodríguez J.M.
  • Díaz López G.
  • Hernando Morata J.A.
  • Kekic M.
  • Renner J.
  • Usón A.
  • Gómez-Cadenas J.J.
  • Adams C.
  • Álvarez V.
  • Arazi L.
  • Arnquist I.J.
  • Azevedo C.D.R.
  • Bailey K.
  • Ballester F.
  • Borges F.I.G.M.
  • Byrnes N.
  • Cárcel S.
  • Carrión J.V.
  • Cebrían S.
  • Church E.
  • Conde C.A.N.
  • Contreras T.
  • Díaz J.
  • Diesburg M.
  • Escada J.
  • Esteve R.
  • Felkai R.
  • Fernandes A.F.M.
  • Fernandes L.M.P.
  • Ferreira A.L.
  • Freitas E.D.C.
  • Generowicz J.
  • Ghosh S.
  • Goldschmidt A.
  • González-Díaz D.
  • Guenette R.
  • Gutíerrez R.M.
  • Haefner J.
  • Hafidi K.
  • Hauptman J.
  • Henriques C.A.O.
  • Herrero P.
  • Herrero V.
  • Ifergan Y.
  • Johnston S.
  • Jones B.J.P.
  • Labarga L.
  • Laing A.
  • Lebrun P.
  • López-March N.
  • Losada M.
  • Mano R.D.P.
  • Martín-Albo J.
  • Martínez A.
  • Martínez-Lema G.
  • McDonald A.D.
  • Monrabal F.
  • Monteiro C.M.B.
  • Mora F.J.
  • Muñoz Vidal J.
  • Novella P.
  • Nygren D.R.
  • Palmeiro B.
  • Para A.
  • Pérez J.
  • Psihas F.
  • Querol M.
  • Repond J.
  • Riordan S.
  • Ripoll L.
  • Rodríguez García Y.
  • Rodríguez J.
  • Rogers L.
  • Romeo B.
  • Romo-Luque C.
  • Santos F.P.
  • dos Santos J.M.F.
  • Simón A.
  • Sofka C.
  • Sorel M.
  • Stiegler T.
  • Toledo J.F.
  • Torrent J.
  • Veloso J.F.C.A.
  • Webb R.
  • Weiss-Babai R.
  • White J.T.
  • Woodruff K.
  • Yahlali N.
  • The NEXT collaboration
In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a 228Th calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of 71.6 ± 1.5 stat± 0.3 sys% for a background acceptance of 20.6 ± 0.4 stat± 0.3 sys% is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies. [Figure not available: see fulltext.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

  • Fernandes, A.F.M.
  • Henriques, C.A.O.
  • Mano, R.D.P.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Silva, P.A.O.C.
  • Gómez-Cadenas, J.J.
  • Freitas, E.D.C.
  • Fernandes, L.M.P.
  • Monteiro, C.M.B.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, G.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Ferrario, P.
  • Ferreira, A.L.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • McDonald, A.D.
  • Monrabal, F.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Psihas, F.
  • Querol, M.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez García, Y.
  • Rodríguez, J.
  • Rogers, L.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
  • The NEXT collaboration
High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe–He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the EL region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mitigation of backgrounds from cosmogenic 137Xe in xenon gas experiments using 3He neutron capture

  • Rogers, L.
  • Jones, B.J.P.
  • Laing, A.
  • Pingulkar, S.
  • Smithers, B.
  • Woodruff, K.
  • Adams, C.
  • Lvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, G.
  • Díaz, J.
  • Diesburg, M.
  • Dingler, R.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Morata, J.A.H.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Kekic, M.
  • Labarga, L.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • McDonald, A.D.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Vidal, J.M.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Redwine, A.B.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • García, Y.R.
  • Rodríguez, J.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • Dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Yahlali, N.
136Xe is used as the target medium for many experiments searching for 0¿ßß. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of 137Xe created by the capture of neutrons on 136Xe. This isotope decays via beta decay with a half-life of 3.8 min and a Q ß of ~4.16 MeV. This work proposes and explores the concept of adding a small percentage of 3He to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from 137Xe activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Sensitivity of the NEXT experiment to Xe-124 double electron capture

  • Martínez-Lema, G.
  • Martínez-Vara, M.
  • Sorel, M.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, G.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernando Morata, J.A.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martín-Albo, J.
  • Martínez, A.
  • McDonald, A.D.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Redwine, A.B.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez García, Y.
  • Rodríguez, J.
  • Rogers, L.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
  • The, NEXT, collaboration
Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture (2¿EC EC) has been predicted for a number of isotopes, but only observed in 78Kr, 130Ba and, recently, 124Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, 0¿EC EC. Here we report on the current sensitivity of the NEXT-White detector to 124Xe 2¿EC EC and on the extrapolation to NEXT-100. Using simulated data for the 2¿EC EC signal and real data from NEXT-White operated with 124Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124Xe and for a 5-year run, a sensitivity to the 2¿EC EC half-life of 6 × 1022 y (at 90% confidence level) or better can be reached. [Figure not available: see fulltext.]
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Accurate gamma and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm

  • González-Díaz, D.
  • Álvarez, V.
  • Borges, F.I.G.
  • Camargo, M.
  • Cárcel, S.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Dafni, T.
  • Díaz, J.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Gehman, V.M.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D.C.
  • García-Irastorza, I.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lopez-March, N.
  • Lorca, D.
  • Losada, M.
  • Luzón, G.
  • Marí, A.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • Miller, T.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Nebot-Guinot, M.
  • Nygren, D.
  • Oliveira, C.A.B.
  • Pérez, J.
  • Pérez Aparicio, J.L.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Santos, F.P.
  • Dos Santos, J.M.F.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Villar, J.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
  • Azevedo, C.
  • Aznar, F.
  • Calvet, D.
  • Castel, J.
  • Ferrer-Ribas, E.
  • García, J.A.
  • Giomataris, I.
  • Gómez, H.
  • Iguaz, F.J.
  • Lagraba, A.
  • Le Coguie, A.
  • Mols, J.P.
  • Sahin, Ö.
  • Rodríguez, A.
  • Ruiz-Choliz, E.
  • Segui, L.
  • Tomás, A.
  • Veenhof, R.
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and ¿-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in ~1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3±0.13mm-s (longitudinal), 0.95±0.20mm-s (transverse) along 1 m drift) besides forming a convenient ''Penning-Fluorescent'' mixture. The TPC, that houses 1.1 kg of gas in its fiducial volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8mm×8mm×1.2mm for approximately 10 cm/MeV-long electron tracks. Resolution in energy (e) at full width half maximum (R) inside the fiducial volume ranged from R=14.6% (30 keV) to R=4.6%(1.275MeV). This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the neutrino-less double beta decay (ßß0¿) in 136Xe, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks. In particular, the obtained energy resolution has been decomposed in its various contributions and improvements towards achieving the R=1.4%v1MeV/e levels obtained in small sensors are discussed.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Conditions for statistical determination of the neutrino mass spectrum in radiative emission of neutrino pairs in atoms

  • Song, Ningqiang
  • Boyero Garcia, R.
  • Gomez-Cadenas, J.J.
  • González García, Ma. Concepción
  • Peralta Conde, A.
  • Taron i Roca, Josep
The photon spectrum in macrocoherent atomic deexcitation via radiative emission of neutrino pairs has been proposed as a sensitive probe of the neutrino mass spectrum, capable of competing with conventional neutrino experiments. In this paper we revisit this interesting proposal in order to quantify the requirements for statistical determination of some of the properties of the neutrino spectrum, in particular, the neutrino mass scale and the mass ordering. Our results are shown as the product of the experimental lifetime, the target volume, and the number density of atoms which have to be set in a coherence state with a given electric field in the target, needed for determination of these properties with a given confidence level.