Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 28
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The Event Detection System in the NEXT-White Detector

  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Simón Estévez, Ander
  • Monrabal Capilla, Francesc
  • Rodriguez-Samaniego, Javier
  • Querol-Segura, Marc
[EN] This article describes the event detection system of the NEXT-White detector, a 5 kg high pressure xenon TPC with electroluminescent amplification, located in the Laboratorio Subterráneo de Canfranc (LSC), Spain. The detector is based on a plane of photomultipliers (PMTs) for energy measurements and a silicon photomultiplier (SiPM) tracking plane for offline topological event filtering. The event detection system, based on the SRS-ATCA data acquisition system developed in the framework of the CERN RD51 collaboration, has been designed to detect multiple events based on online PMT signal energy measurements and a coincidence-detection algorithm. Implemented on FPGA, the system has been successfully running and evolving during NEXT-White operation. The event detection system brings some relevant and new functionalities in the field. A distributed double event processor has been implemented to detect simultaneously two different types of events thus allowing simultaneous calibration and physics runs. This special feature provides constant monitoring of the detector conditions, being especially relevant to the lifetime and geometrical map computations which are needed to correct high-energy physics events. Other features, like primary scintillation event rejection, or a double buffer associated with the type of event being searched, help reduce the unnecessary data throughput thus minimizing dead time and improving trigger efficiency., The NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT, the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FISNUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Demonstration of neutrinoless double beta decay searches in gaseous xenon with NEXT

  • Novella, P.
  • Sorel, M.
  • Usón, A.
  • Adams, C.
  • Almazán, H.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I.J.
  • Auria-Luna, F
  • Ayet, S.
  • C.D.R. Azevedo
  • Bailey, K.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT experiment aims at the sensitive search of the neutrinoless double beta decay in Xe-136, using high-pressure gas electroluminescent time projection chambers. The NEXT-White detector is the first radiopure demonstrator of this technology, operated in the Laboratorio Subterr & aacute;neo de Canfranc. Achieving an energy resolution of 1% FWHM at 2.6 MeV and further background rejection by means of the topology of the reconstructed tracks, NEXT-White has been exploited beyond its original goals in order to perform a neu-trinoless double beta decay search. The analysis considers the combination of 271.6 days of Xe-136-enriched data and 208.9 days of 136Xe-depleted data. A detailed background mod-eling and measurement has been developed, ensuring the time stability of the radiogenic and cosmogenic contributions across both data samples. Limits to the neutrinoless mode are obtained in two alternative analyses: a background-model-dependent approach and a novel direct background-subtraction technique, offering results with small dependence on the background model assumptions. With a fiducial mass of only 3.50 +/- 0.01 kg of Xe-136-enriched xenon, 90% C.L. lower limits to the neutrinoless double beta decay are found in the T-1/2(0 nu) > 5.5x10(23) -1.3x10(24) yr range, depending on the method. The presented techniques stand as a pro of-of-concept for the searches to be implemented with larger NEXT detectors., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and the Severo Ochoa Program grant CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The electronics of the energy plane of the NEXT-White detector

  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Laing, A.
  • Rodriguez-Samaniego, Javier
  • Querol-Segura, Marc
  • Monrabal, Francesc
  • Gómez-Cadenas, J.J.
[EN] This paper describes the electronics of NEXT-White (NEW) detector PMT plane, a high pressure xenon TPC with electroluminescent amplification (HPXe-EL) currently operating at the Laboratorio Subterraneo de Canfranc (LSC) in Huesca, Spain. In NEXT-White the energy of the event is measured by a plane of photomultipliers (PMTs) located behind a transparent cathode. The PMTs are Hamamatsu R11410-10 chosen due to their low radioactivity. The electronics have been designed and implemented to fulfill strict requirements: an overall energy resolution below 1% and a radiopurity budget of 20 mBq unit(-1) in the chain of Bi-214. All the components and materials have been carefully screened to assure a low radioactivity level and at the same time meet the required front-end electronics specifications. In order to reduce low frequency noise effects and enhance detector safety a grounded cathode connection has been used for the PMTs. This implies an AC-coupled readout and baseline variations in the PMT signals. A detailed description of the electronics and a novel approach based on a digital baseline restoration to obtain a linear response and handle AC coupling effects is presented. The final PMT channel design has been characterized with linearity better than 0.4% and noise below 0.4mV., We acknowledge support from the following agencies and institutions: the European Research Council (ERC), Spain under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program, Spain SEV-2014-0398 and the Maria de Maetzu Program, Spain MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT and FEDER, Spain through the program COMPETE, projects PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and de-sc0017721 (University of Texas at Arlington); and the University of Texas at Arlington. We acknowledge partial support from the European Union Horizon 2020 research and innovation programme, Spain under the Marie Sklodowska-Curie grant agreements No. 690575 and 674896. We also warmly acknowledge the Laboratorio Nazionale di Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Demonstration of background rejection using deep convolutional neural networks in the NEXT experiment

  • Kekic, M.
  • Adams, C.
  • Woodruff, K.
  • Renner, J.
  • Church, E.
  • Del Tutto, M.
  • Hernando Morata, J. A.
  • Gomez-Cadenas, J. J.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Convolutional neural networks (CNNs) are widely used state-of-the-art computer vision tools that are becoming increasingly popular in high-energy physics. In this paper, we attempt to understand the potential of CNNs for event classification in the NEXT experiment, which will search for neutrinoless double-beta decay in Xe-136. To do so, we demonstrate the usage of CNNs for the identification of electron-positron pair production events, which exhibit a topology similar to that of a neutrinoless double-beta decay event. These events were produced in the NEXT-White high-pressure xenon TPC using 2.6 MeV gamma rays from a Th-228 calibration source. We train a network on Monte Carlo-simulated events and show that, by applying on-the-fly data augmentation, the network can be made robust against differences between simulation and data. The use of CNNs offers significant improvement in signal efficiency and background rejection when compared to previous non-CNN-based analyses, This study used computing resources from Artemisa, co-funded by the European Union through the 2014-2020 FEDER Operative Programme of the Comunitat Valenciana, project DIFEDER/2018/048. This research used resources of the Argonne Leadership Computing Facility, which is a DOE Office of Science User Facility supported under Contract DE-AC02-06CH11357. The NEXT collaboration acknowledges support from the following agencies and institutions: Xunta de Galicia (Centro singularde investigacion de Galicia accreditation 2019-2022), by European Union ERDF, and by the "Maria de Maeztu" Units of Excellence program MDM-2016-0692 and the Spanish Research State Agency"; the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-20140398 and CEX2018-000867-S; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015 18820. JMA acknowledges support from Fundacion Bancaria "la Caixa" (ID 100010434), grant code LCF/BQ/PI19/11690012. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Data Compression in the NEXT-100 Data Acquisition System

  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Rodríguez Ponce, Jorge
  • Simón Estévez, Ander
  • Benlloch Rodríguez, José María
[EN] NEXT collaboration detectors are based on energy measured by an array of photomultipliers (PMT) and topological event filtering based on an array of silicon photomultipliers (SiPMs). The readout of the PMT sensors for low-frequency noise effects and detector safety issues requires a grounded cathode connection that makes the readout AC-couple with variations in the signal baseline. Strict detector requirements of energy resolution better than 1% FWHM require a precise baseline reconstruction that is performed offline for data analysis and detector performance characterization. Baseline variations make it inefficient to apply traditional lossy data compression techniques, such as zero-suppression, that help to minimize data throughput and, therefore, the dead time of the system. However, for the readout of the SiPM sensors with less demanding requirements in terms of accuracy, a traditional zero-suppression is currently applied with a configuration that allows for a compression ratio of around 71%. The third stage in the NEXT detectors program, the NEXT-100 detector, is a 100 kg detector that instruments approximately five times more PMT sensors and twice the number of SiPM sensors than its predecessor, the NEXT-White detector, putting more pressure in the DAQ throughput, expected to be over 900 MB/s with the current configuration, which will worsen the dead time of the acquisition data system. This paper describes the data compression techniques applied to the sensor data in the NEXT-100 detector, which reduces data throughput and minimizes dead time while maintaining the event rate to the level of its predecessor, around 50 Hz., NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Research Council (ERC) under Grant Agreement No. 101039048-GanESS; the European Union's Framework Program for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI/10.13039/501100011033 of Spain and ERDF A way of making Europe under grant RTI2018-095979, the Severo Ochoa Program grant CEX2018-000867-S and the Maria de Maeztu Program grant MDM-2016-0692; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under grants 877040 and 877041; the US Department of Energy under contract number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401. A.S.E acknowledges support from the Kreitman School of Advanced Graduate Studies at Ben-Gurion University and from the Marie Sklodowska-Curie grant agreement No. 101026628. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ion transport on phased radiofrequency carpets in xenon gas

  • Dey, E.
  • Jones, B. J. P.
  • Mei, Y.
  • Brodeur, M.
  • Chirayath, V. A.
  • Coward, N.
  • Foss, F. W.
  • Navarro, K. E.
  • Parmaksiz, I.
  • Adams, C.
  • Almazán, H.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • García-Barrena, Jara
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] We present the design and performance of a four-phased radiofrequency (RF) carpet system for ion transport between 200–600 mbar, significantly higher than previously demonstrated RF carpet applications. The RF carpet, designed with a 160 μm pitch, is applied to the lateral collection of ions in xenon at pressures up to 600 mbar. We demonstrate transport efficiency of caesium ions across varying pressures, and compare with microscopic simulations made in the SIMION package. The novel use of an N-phased RF carpet can achieve ion levitation and controlled lateral motion in a denser environment than is typical for RF ion transport in gases. This feature makes such carpets strong candidates for ion transport to single ion sensors envisaged for future neutrinoless double-beta decay experiments in xenon gas., The work in this paper was funded by the US Department of Energy under DE-SC0019054 and DE-SC0019223 to the University of Texas at Arlington. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and RTI2018-095979, and the Severo Ochoa and Maria de Maeztu Program grants CEX2023-001292-S, CEX2023-001318-M and CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CISEJI/2023/27; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401; Deutsche Forschungsgemeinschaft (DFG, German Research Foundation)-AY 155/2-1; MB acknowledge support from the National Science Foundation under grant number PHY-2310059. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

First results of the NEXT-100 detector using 83mKr decays

  • Martinez-Lema, G.
  • Herves Carrete, C.
  • Torelli, S.
  • Cid Laso, M.
  • Vazquez Cabaleiro, P.
  • Palmeiro, B.
  • Hernando Morata, J. A.
  • Gomez-Cadenas, J. J.
  • Adams, C.
  • Almazan, H.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I. J.
  • Auria-Luna, F.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • García-Barrena, Jara
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • MARTÍNEZ PÉREZ, ALBERTO
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT Collaboration is investigating the double beta decay of ¹³¿Xe using high-pressure gaseous electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from ¿³¿Kr decays, which allow the detector response to be mapped throughout the active volume and its stability to be monitored over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for ¿³¿Kr point-like energy deposits contained within a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar, we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with those obtained in NEXT-White, and an E¿¹¿² extrapolation to Q<sub>ßß</sub> yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreements No. 951281-BOLD and 101039048-GanESS; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 860881-HIDDeN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and RTI2018-095979, and the Severo Ochoa and Maria de Maeztu Program grants CEX2023-001292-S, CEX2023-001318-M and CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087, ASFAE/2022/028, ASFAE/2022/029, CISEJI/2023/27 and CIDEXG/2023/16; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contract numbers DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A. Welch Foundation under award number Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Radiopurity assessment of the energy readout for the NEXT double beta decay experiment

  • Cebrian, S.
  • Perez, J.
  • Bandac, I.
  • Labarga, L.
  • Azevedo, C. D. R.
  • Benlloch-Rodriguez, J. M.
  • Borges, F. I. G. M.
  • Botas, A.
  • Carcel, S.
  • Carrión, J.V.
  • Conde, C. A. N.
  • Diaz, J.
  • Diesburg, M.
  • Escada, J.
  • Querol-Segura, Marc
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The "Neutrino Experiment with a Xenon Time-Projection Chamber" (NEXT) experiment intends to investigate the neutrinoless double beta decay of 136Xe, and therefore requires a severe suppression of potential backgrounds. An extensive material screening and selection process was undertaken to quantify the radioactivity of the materials used in the experiment. Separate energy and tracking readout planes using different sensors allow us to combine the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. The design of radiopure readout planes, in direct contact with the gas detector medium, was especially challenging since the required components typically have activities too large for experiments demanding ultra-low background conditions. After studying the tracking plane, here the radiopurity control of the energy plane is presented, mainly based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain). All the available units of the selected model of photomultiplier have been screened together with most of the components for the bases, enclosures and windows. According to these results for the activity of the relevant radioisotopes, the selected components of the energy plane would give a contribution to the overall background level in the region of interest of at most 2.4 × 10¿4 counts per keV, kg and year, satisfying the sensitivity requirements of the NEXT experiment., Special thanks are due to LSC directorate and staff for their strong support for performing the measurements at the LSC Radiopurity Service. We are really grateful to Grzegorz Zuzel for the radon emanation measurements. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the GVA of Spain under grant PROMETEO/2016/120; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A & and the University of Texas at Arlington.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Electron drift properties in high pressure gaseous xenon

  • Simon, A.
  • Felkai, R.
  • Martinez-Lema, G.
  • Monrabal, F.
  • Gonzalez-Diaz, D.
  • Sorel, M.
  • Hernando Morata, J. A.
  • Gomez-Cadenas, J. J.
  • Adams, C.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Gaseous time projection chambers (TPC) are a very attractive detector technology for particle tracking. Characterization of both drift velocity and di¿usion is of great importance to correctly assess their tracking capabilities. NEXT-White is a High Pressure Xenon gas TPC with electroluminescent ampli¿cation, a 1:2 scale model of the future NEXT-100detector, which will be dedicated to neutrinoless double beta decay searches. NEXT-White has been operating at Canfranc Underground Laboratory (LSC) since December2016. The drift parameters have been measured using 83mKr for a range of reduced drift ¿elds at two di¿erent pressure regimes, namely 7.2 bar and 9.1 bar. Theresults have been compared with Magboltz simulations. Agreement at the 5% level or better has been found for drift velocity, longitudinal di¿usion and transverse di¿usion., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT and FEDER through the program COMPETE, projects PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and de-sc0017721 (University of Texas at Arlington); and the University of Texas at Arlington. We also warmly acknowledge the Laboratorio Nazionale di Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The Next White (NEW) detector

  • Monrabal, F.
  • Gomez-Cadenas, J. J.
  • Laing, A.
  • Benlloch-Rodriguez, J. M.
  • Carcel, S.
  • Carrion, J
  • Felkai, R.
  • Martinez, A.
  • Musti, M.
  • Ouero, M.
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
[EN] Conceived to host 5 kg of xenón at a pressure of 15 bar in the ¿ducial volume,the NEXTWhite (NEW)apparatus is currently the largest high pressure xenon gas TPC using electroluminescent ampli¿cation in the world. It is also a 1:2 scale model of the NEXT-100 detector scheduled to start searching for ßß0¿ decays in 136Xe in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2017 at the Canfranc Underground Laboratory (LSC), in Spain. This paper describes the detector and associated infrastructures., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT and FEDER through the program COMPETE, projects PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contract numbers DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0017721 (University of Texas at Arlington), and DE-AC02-06CH11357 (Argonne National Laboratory); and the University of Texas at Arlington. We also warmly acknowledge the Laboratorio Nazionale di Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Electroluminescence TPCs at the thermal diffusion limit

  • Henriques, C. A. O.
  • Monteiro, C. M. B.
  • Gonzalez-Diaz, D.
  • Azevedo, C. D. R.
  • Freitas, E. D. C.
  • Mano, R. D. P.
  • Jorge, M. R.
  • Fernandes, A. F. M.
  • Gomez-Cadenas, J. J.
  • Fernandes, L. M. P.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the 136Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO2, CH4 and CF4) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/ sqrt(¿) for pure xenon down to 2.5 mm/sqrt(m) using additive concentrations of about 0.05%, 0.2% and 0.02% for CO2, CH4 and CF4, respectively. Our results show that CF4 admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH4 presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO2 and CH4 show potential as molecular additives in a large xenon TPC. While CO2 has some operational constraints, making it difficult to be used in a large TPC, CH4 shows the best performance and stability as molecular additive to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%, which is only slightly worse than the one obtained for pure xenon. We demonstrate the possibility to have an electroluminescence TPC operating very close to the thermal diffusion limit without jeopardizing the TPC performance, if CO2 or CH4 are chosen as additives., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-AC02-06CH11357 (Argonne National Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0017721 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A programmable, multichannel power supply for SiPMs with temperature compensation loop and Ethernet interface

  • Querol-Segura, Marc
  • Rodriguez-Samaniego, Javier
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
Among the different techniques available, the SiPM power supply described in this paper uses output voltage and sensor temperature feedback. A high-resolution ADC digitizes both the output voltage and an analog signal proportional to the SiPM temperature for each of its 16 independent outputs. The appropriate change in the bias voltage is computed in a micro-controller and this correction is applied via a high resolution DAC to the control input of a DC/DC module that produces the output voltage. This method allows a reduction in gain variations from typically 30% to only 0.5% in a 10ºC range. The power supply is housed in a 3U-height aluminum box. A 2.8 touch screen on the front panel provides local access to the configuration and monitoring functions using a graphical interface. The unit has an Ethernet interface on its rear side to provide remote operation and integration in slow control systems using the encrypted and secure SSH protocol. A LabVIEW application with SSH interface has been designed to operate the power supply from a remote computer. The power supply has good characteristics, such as 85 V output range with 1 mV resolution and stability better than 2 mVP, excellent output load regulation and programmable rise and fall voltage ramps. Commercial power supplies from well-known manufacturers can show far better specifications though can also result in an over featured and over costly solution for typical applications., The authors acknowledge support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants CONSOLIDER-Ingenio 2010 CSD2008-0037 (CUP), FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A & and the University of Texas at Arlington.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air

  • Ghosh, S.
  • Haefner, J.
  • Martín-Albo, J.
  • Guenette, R.
  • Li, X.
  • Loya Villalpando, A.A.
  • Burch, C.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Benlloch-Rodríguez, J.M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm We also see that the reflectance of PIFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM-2016-0692; the Generalitat Valenciana under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington (USA). DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC2015-18820. JM-A acknowledges support from Fundacion Bancaria "la Caixa" (ID 100010434), grant code LCF/BQ/PI19/11690012. Finally, we thank Brendon Bullard, Paolo Giromini and Neeraj Tata for helpful discussions and assistance with preliminary measurements.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Microscopic simulation of xenon-based optical TPCs in the presence of molecular additives

  • Azevedo, C.D.R.
  • Gonzalez-Diaz, D.
  • Biagi, S. F.
  • Oliveira, C. A. B.
  • Henriques, C. A. O.
  • Escada, J.
  • Monrabal, F.
  • Gomez-Cadenas, J. J.
  • Alvarez, V.
  • Querol-Segura, Marc
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] We introduce a simulation framework for the transport of high and low energy electrons in xenon-based optical time projection chambers (OTPCs). The simulation relies on elementary cross sections (electron-atom and electron-molecule) and incorporates, in order to compute the gas scintillation, the reaction/quenching rates (atom-atom and atom-molecule) of the first 41 excited states of xenon and the relevant associated excimers, together with their radiative cascade. The results compare positively with observations made in pure xenon and its mixtures with CO2 and CF4 in a range of pressures from 0.1 to 10 bar. This work sheds some light on the elementary processes responsible for the primary and secondary xenon-scintillation mechanisms in the presence of additives, that are of interest to the OTPC technology., DGD is supported by the Ramon y Cajal program (Spain) under contract number RYC-2015-18820. The authors want to acknowledge the RD51 collaboration for encouragement and support during the elaboration of this work, and in particular discussions with F. Resnati, A. Milov, V. Peskov, M. Suzuki and A. F. Borghesani. The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the GVA of Spain under grant PROM-ETEO/2016/120; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS-NUC/2525/2014 and UID/FIS/04559/2013; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A& and the University of Texas at Arlington.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Demonstration of Single-Barium-Ion Sensitivity for Neutrinoless Double-Beta Decay Using Single-Molecule Fluorescence Imaging

  • McDonald, A.D.
  • Jones, B.J.P.
  • Nygren, D.R.
  • Adams, C.
  • Azevedo, C.D.R.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel García, Sara
  • Carrión Burguete, José Vicente
  • Cebrian, S.
  • Conde, C.A.N.
  • Diaz, J.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] A new method to tag the barium daughter in the double-beta decay of Xe-136 is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba++) resolution at a transparent scanning surface is demonstrated. A single-step photobleach confirms the single ion interpretation. Individual ions are localized with superresolution (similar to 2 nm), and detected with a statistical significance of 12.9 sigma over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double-beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers., NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Advanced Grant No. 339787-NEXT, the Ministerio de Economia y Competitividad of Spain under Grants No. FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398, the Generalitat Valenciana (GVA) of Spain under Grant No. PROMETEO/2016/120, the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008, the U.S. Department of Energy under Contracts No. DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and No. DE-FG02-13ER42020 (Texas A&M) and No. DE-SC0017721 (University of Texas at Arlington), and the University of Texas at Arlington.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Demonstration of the event identification capabilities of the NEXT-White detector

  • Ferrario, Paola
  • Benlloch-Rodríguez, J.M.
  • Díaz López, G.
  • Hernando Morata, J.A.
  • Kekic, M.
  • Renner, J.
  • Usón, A.
  • Gómez-Cadenas, J.J.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a 228Th calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of 71.6 ± 1.5 stat ± 0.3 sys% for a background acceptance of 20.6 ± 0.4 stat ± 0.3 sys% is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/FBD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Secondary scintillation yield of xenon with sub-percent levels of CO2 additive for rare-event detection

  • HENRIQUES, C.A.
  • Freitas, E.D.C.
  • Azevedo, C.D.R.
  • González-Díaz, D.
  • Mano, R.D.P.
  • Jorge, M.R.
  • Fernandes, L.M.P.
  • Monteiro, C.M.B.
  • Gómez-Cadenas, J.J.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel García, Sara
  • Carrión Burguete, José Vicente
  • Querol-Segura, Marc
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Xe-CO2 mixtures are important alternatives to pure xenon in Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification with applications in the important field of rare event detection such as directional dark matter, double electron capture and double beta decay detection. The addition of CO2 to pure xenon at the level of 0.05-0.1% can reduce significantly the scale of electron diffusion from 10 mm/root m to 2.5 mm/root m, with high impact on the discrimination of the events through pattern recognition of the topology of primary ionization trails. We have measured the electroluminescence (EL) yield of Xe-CO2 mixtures, with sub-percent CO2 concentrations. We demonstrate that the EL production is still high in these mixtures, 70% and 35% relative to that produced in pure xenon, for CO2 concentrations around 0.05% and 0.1%, respectively. The contribution of the statistical fluctuations in EL production to the energy resolution increases with increasing CO2 concentration, being smaller than the contribution of the Fano factor for concentrations below 0.1% CO2. (C) 2017 The Author. Published by Elsevier B.V., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under grants FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the GVA of Spain under grant PROMETEO/2016/120; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A & the University of Texas at Arlington. C.A.O.H., E.D.C.F., C.M.B.M. and C.D.R.A. acknowledge FCT under grants PD/BD/105921/2014, SFRH/BPD/109180/2015, SFRH/BPD/76842/2011 and SFRH/BPD/79163/2011, respectively.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo de revisión (ReviewArticle)

Measurement of energy resolution with the NEXT-White silicon photomultipliers

  • Contreras, T.
  • Palmeiro, B.
  • Almazán, H.
  • Para, A.
  • Martinez-Lema, G.
  • Guenette, R.
  • Adams, C.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I.J.
  • Auria-Luna, F.
  • Ayet, S.
  • Azevedo, C.D.R.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and silicon photomultipliers (SiPMs) to extract topology information. This analysis uses 83mKr data from the NEXT-White detector to measure and understand the energy resolution that can be obtained with the SiPMs, rather than with PMTs. The energy resolution obtained of (10.9±0.6)%, full-width half-maximum, is slightly larger than predicted based on the photon statistics resulting from very low light detection coverage of the SiPM plane in the NEXT-White detector. The difference in the predicted and measured resolution is attributed to poor corrections, which are expected to be improved with larger statistics. Furthermore, the JHEP09(2024)112 noise of the SiPMs is shown to not be a dominant factor in the energy resolution and may be negligible when noise subtraction is applied appropriately, for high-energy events or larger SiPM coverage detectors. These results, which are extrapolated to estimate the response of large coverage SiPM planes, are promising for the development of future, SiPM-only, readout planes that can offer imaging and achieve similar energy resolution to that previously demonstrated with PMTs., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union’s Framework Programme for Research and Innovation, Horizon 2020 (2014–2020), under Grant Agreement No. 957202-HIDDEN; Spain’s MCIN/AEI and the ERDF (“A way of making Europe”) under grants PID2021-125475NB and the Severo Ochoa Programme grant CEX2018-000867-S; the Generalitat Valenciana (Spain) under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Department of Education of the Basque Government (Spain) under the predoctoral training programme for non-doctoral research personnel; the “la Caixa” Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese Foundation for Science and Technology (FCT) under project UID/FIS/04559/2020 supporting the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19, and 465; the U.S. Department of Energy under contract numbers DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (The University of Texas at Arlington), and DE-SC0019223 (The University of Texas at Arlington); the U.S. National Science Foundation under award NSF CHE-2004111; and the Robert A. Welch Foundation under award Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterráneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Sensitivity of the NEXT experiment to 124-Xe double electron capture

  • Martinez-Lema, G.
  • Martinez-Vara, M.
  • Sorel, M.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Borges, F. I. G. M.
  • Byrnes, N.
  • Carcel, S.
  • Carrión, J. V.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite di erent, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture has been predicted for a number of isotopes, but only observed in 78Kr, 130Ba and, recently, 124Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process. Here we report on the current sensitivity of the NEXT-White detector to 124Xe 2 ECEC and on the extrapolation to NEXT-100. Using simulated data for the 2 ECEC signal and real data from NEXT-White operated with 124Xe-depleted gas as background, we de ne an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124Xe and for a 5-year run, a sensitivity to the two-neutroni double electron capture half-life of 6x10exp22 years (at 90% con dence level) or better can be reached., The NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

  • Fernandes, A.F.M.
  • Henriques, C.A.O.
  • Mano, R.D.P.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Silva, P.A.O.C.
  • Gómez-Cadenas, J.J.
  • Freitas, E.D.C.
  • Fernandes, L.M.P.
  • Monteiro, C.M.B.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Bailey, K.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the EL region, the EL yield is lowered by similar to 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economa y Competitividad of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Mara de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015; the U.S. Department of Energy under contracts number DEAC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A& M) and DE-SC0019223/DESC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

High voltage delivery and distribution for the NEXT-100 Time Projection Chamber

  • Adams, C.
  • Almazan, H.
  • Bailey, K.
  • Guenette, R.
  • Jones, B. J. P.
  • Johnston, S.
  • Mistry, K.
  • Monrabal, F.
  • Nygren, D. R.
  • Palmeiro, B.
  • Rogers, L.
  • Waldschmidt, J.
  • Aranburu, A. I.
  • Arazi, L.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • García-Barrena, Jara
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] A critical element in the realization of large liquid and gas time projection chambers (TPCs) is the delivery and distribution of high voltages into and around the detector. Such experiments require of order tens of kilovolts to enable electron drift over meter-scale distances. This paper describes the design and operation of the cathode feedthrough and high voltage distribution through the field cage of the NEXT-100 experiment, an underground TPC that will search for neutrinoless double beta decay 0v beta beta The feedthrough has been demonstrated to hold pressures up to 20 bar and sustain voltages as high as -65 kV. The TPC is operating stably at its design high voltages. The system has been realized within the constraints of a stringent radiopurity budget and is now being used to execute a suite of sensitive double beta decay analyses., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and RTI2018-095979, and the Severo Ochoa and Maria de Maeztu Program grants CEX2023-001292-S, CEX2023-001318-M and CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CISEJI/2023/27; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 and DE-SC0024438 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Sensitivity of a tonne-scale NEXT detector for neutrinoless double-beta decay searches

  • Adams, C.
  • Alvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Borges, F. I. G. M.
  • Byrnes, N.
  • Carcel, S.
  • Carrión, J.V.
  • Cebrian, S.
  • Church, E.
  • Conde, C. A. N.
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta (0 nu beta beta) decay of Xe-136 using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of 0 nu beta beta decay better than 10(27) years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program grants SEV-2014-0398 and CEX2018-000867-S, and the Maria de Maeztu Program MDM2016-0692; the Generalitat Valenciana of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014 and under projects UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under grants 877040 and 877041; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC0207CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges support from the Ramon y Cajal program (Spain) under contract number RYC-2015-18820. JM-A acknowledges support from Fundacion Bancaria la Caixa (ID 100010434), grant code LCF/BQ/PI19/11690012, and from the Plan GenT program of the Generalitat Valenciana, grant code CIDEGENT/2019/049. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The NEXT-100 Detector

  • Adams, C.
  • Almazan, H.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I. J.
  • Auria-Luna, F.
  • Ayet, S.
  • Ayyad, Y.
  • Azevedo, C. D. R.
  • Bailey, K.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • García-Barrena, Jara
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • MARTÍNEZ PÉREZ, ALBERTO
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] The NEXT collaboration is dedicated to the study of double beta decays of 136\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<^>{136}$$\end{document}Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (<= 1%\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\le 1\%$$\end{document} FWHM at the Q beta beta\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$Q_{\beta \beta }$$\end{document} value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterr & aacute;neo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at similar to\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\sim $$\end{document}4 bar and drift fields of 74Vcm-1\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$74\hbox { V cm}<^>{-1}$$\end{document} and 118Vcm-1\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$118\hbox { V cm}<^>{-1}$$\end{document}, respectively. Alpha decays from the 222\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<^>{222}$$\end{document}Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreements No. 951281-BOLD and 101039048-GanESS; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 860881-HIDDeN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and RTI2018-095979, and the Severo Ochoa and Maria de Maeztu Program grants CEX2023-001292-S, CEX2023-001318-M and CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087, ASFAE/2022/028, ASFAE/2022/029, CISEJI/2023/27, and CIDEXG/2023/16; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M), DE-SC0019054, DE-SC0019223 and DE-SC0024438 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Neutral Bremsstrahlung Emission in Xenon Unveiled

  • Henriques, C.A.O.
  • Amedo, P.
  • Teixeira, J. M. R.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Para, A.
  • Martín-Albo,J.
  • Saa Hernandez, A.
  • Gómez-Cadenas, J. J.
  • Nygren, D. R.
  • Monteiro, C.M.B.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Lopez-March, N.
  • Rodríguez, J.
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] We present evidence of non-excimer-based secondary scintillation in gaseous xenon, obtained using both the NEXT-White time projection chamber (TPC) and a dedicated setup. Detailed comparison with first-principle calculations allows us to assign this scintillation mechanism to neutral bremsstrahlung (NBrS), a process that is postulated to exist in xenon that has been largely overlooked., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Advanced Grant No. 339787-NEXT; the European Unions Framework Program for Research and Innovation Horizon 2020 (20142020) under Grant Agreements No. 674896, No. 690575, and No. 740055; the Ministerio de Economa y Competitividad and the Ministerio de Ciencia, Innovacin y Universidades of Spain under Grants No. FIS2014-53371-C04 and No. RTI2018-095979, the Severo Ochoa Program Grants No. SEV-2014-0398 and No. CEX2018-000867-S, and the Mara de Maeztu Program MDM-2016-0692; the Generalitat Valenciana under Grants No. PROMETEO/2016/120 and No. SEJI/2017/011; the Portuguese FCT under Project No. PTDC/FIS-NUC/3933/2021 and under Project No. UIDP/04559/2020 to fund the activities of LIBPhys-UC; the U.S. Department of Energy under Contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), No. DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), No. DE-FG02-13ER42020 (Texas A&M), and No. DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington (USA). D. G.-D. acknowledges Ramon y Cajal program (Spain) under Contract No. RYC- 2015-18820. J. M.-A. acknowledges support from Fundacin Bancaria la Caixa (ID 100010434), Grant No. LCF/BQ/PI19/11690012. We would like to thank Lorenzo Muniz for insightful discussions on the subtleties of electron transport in gases.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Radiogenic backgrounds in the NEXT double beta decay experiment

  • Novella, P.
  • Palmeiro, B.
  • Sorel, M.
  • Usón, A.
  • Ferrario, P.
  • Gómez-Cadenas, J. J.
  • Adams, C.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Benlloch-Rodríguez, J. M.
  • Borges, F. I. G. M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity- induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterraneo de Canfranc with xenon depleted in Xe-136 are analyzed to derive a total background rate of (0.84 +/- 0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT collaboration. A spectral fit to this model yields the specific contributions of Co-60, K-40, Bi-214 and Tl-208 to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25 +/- 0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5 sigma after 1 year of data taking. The background measurement in a Q(beta beta)+/- 100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75 +/- 0.12) events., The NEXT collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under the Marie Sklodowska-Curie Grant Agreements No. 674896, 690575 and 740055; the Ministerio de Economia y Competitividad and the Ministerio de Ciencia, Innovacion y Universidades of Spain under grants FIS2014-53371-C04, RTI2018-095979, the Severo Ochoa Program SEV-2014-0398 and the Maria de Maetzu Program MDM-2016-0692; the GVA of Spain under grants PROMETEO/2016/120 and SEJI/2017/011; the Portuguese FCT under project PTDC/FIS-NUC/2525/2014, under project UID/FIS/04559/2013 to fund the activities of LIBPhys, and under grants PD/BD/105921/2014, SFRH/BPD/109180/2015 and SFRH/BPD/76842/2011; the U.S. Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A&M) and DE-SC0019223/DE-SC0019054 (University of Texas at Arlington); and the University of Texas at Arlington. DGD acknowledges Ramon y Cajal program (Spain) under contract number RYC-2015-18820. We also warmly acknowledge the Laboratori Nazionali del Gran Sasso (LNGS) and the Dark Side collaboration for their help with TPB coating of various parts of the NEXT-White TPC. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Demonstration of event position reconstruction based on diffusion in the NEXT-white detector

  • Haefner, J.
  • Navarro, K.E.
  • Guenette, R.
  • Jones, B.J.P.
  • Tripathi, Animesh
  • Adams, C.
  • Almazán, H.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I.J.
  • Auria-Luna, F
  • Ayet, S.
  • Azevedo, C.D.R.
  • Ballester, F.
  • Esteve, R.
  • Mora, F.J.
  • Rodríguez, J.
  • Herrero, V.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
[EN] Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from Kr-83m calibration electron captures (E similar to 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias <1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E >= 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q(beta beta) in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant Agreement No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant Agreement No. 957202-HIDDEN; the MCIN/AEI of Spain and ERDF A way of making Europe under grants PID2021-125475NB and the Severo Ochoa Program grant CEX2018-000867-S; the Generalitat Valenciana of Spain under grants PROMETEO/2021/087 and CIDEGENT/2019/049; the Department of Education of the Basque Government of Spain under the predoctoral training program non-doctoral research personnel; the Spanish la Caixa Foundation (ID 100010434) under fellowship code LCF/BQ/PI22/11910019; the Portuguese FCT under project UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Israel Science Foundation (ISF) under grant 1223/21; the Pazy Foundation (Israel) under grants 310/22, 315/19 and 465; the US Department of Energy under contracts number DE-AC02-06CH11357 (Argonne National Laboratory), DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), DE-FG02-13ER42020 (Texas A &M), DE-SC0019054 (Texas Arlington) and DE-SC0019223 (Texas Arlington); the US National Science Foundation under award number NSF CHE 2004111; the Robert A Welch Foundation under award number Y-2031-20200401.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Measurement of the Xe 136 two-neutrino double -decay half-life via direct background subtraction in NEXT

  • Novella, P.
  • Sorel, M.
  • Usón, A.
  • Adams, C.
  • Almazán, H.
  • Aparicio, B.
  • Aranburu, A. I.
  • Arazi, L.
  • Arnquist, I.J.
  • Ayet, S.
  • Azevedo, D.C.R.
  • Bailey, K.
  • Benlloch-Rodriguez, J. M.
  • Lopez-March, N.
  • Rodríguez, J.
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Ballester Merelo, Francisco José|||0000-0002-2464-5116
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] We report a measurement of the half-life of the 136Xe two-neutrino double-ß decay performed with a novel direct-background-subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with 136Xe-enriched and 136Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of 2.34+0.80(stat)+0.30(sys)×1021 yr is derived from ¿0.46 ¿0.17 the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double-ß-decay searches., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under Grant No. 951281-BOLD; the European Union's Framework Programme for Research and Innovation Horizon 2020 (2014-2020) under Grant No. 957202-HIDDEN; the MCIN/AEI/10.13039/501100011033 of Spain and ERDF "A way of making Europe" under Grant No. RTI2018-095979, the Severo Ochoa Program Grant No. CEX2018-000867-S, and the Maria de Maeztu Program Grant No. MDM-2016-0692; the Generalitat Valenciana of Spain under Grants No. PROMETEO/2021/087 and No. CIDEGENT/2019/049; the Portuguese FCT under Project No. UID/FIS/04559/2020 to fund the activities of LIBPhys-UC; the Pazy Foundation (Israel) under Grants No. 877040 and No. 877041; the U.S. Department of Energy under Contracts No. DE-AC02-06CH11357 (Argonne National Laboratory), No. DE-AC02-07CH11359 (Fermi National Accelerator Laboratory), No. DE-FG02-13ER42020 (Texas A&M), No. DE-SC0019054 (Texas Arlington), and No. DE-SC0019223 (Arlington, TX); the U.S. National Science Foundation under Grant No. CHE 2004111; and the Robert A. Welch Foundation under Grant No. Y-203120200401. D.G.D. acknowledges support from the Ramon y Cajal program (Spain) under Contract No. RYC-2015-18820. Finally, we are grateful to the Laboratorio Subterraneo de Canfranc for hosting and supporting the NEXT experiment.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Sensitivity of NEXT-100 to neutrinoless double beta decay

  • Martín-Albo, J.
  • Muñoz Vidal, J.
  • Ferrario, P.
  • Nebot-Guinot, M.
  • Gomez-Cadenas, J. J.
  • Azevedo, C.D.R.
  • Borges, F.I.G.
  • Carcel, S.
  • Querol, M.
  • Rodriguez-Samaniego, Javier
  • Álvarez-Puerta, Vicente|||0000-0001-6938-8259
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta (0¿ßß) decay of 136Xe. The detector possesses two features of great value for 0¿ßß searches: energy resolution better than 1% FWHM at the Q value of 136Xe and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most 4 × 10¿4 counts keV¿1 kg¿1 yr¿1. Accordingly, the detector will reach a sensitivity to the 0¿ßß-decay half-life of 2.8 × 1025 years (90% CL) for an exposure of 100 kg·year, or 6.0 × 1025 years after a run of 3 effective years., The NEXT Collaboration acknowledges support from the following agencies and institutions: the European Research Council (ERC) under the Advanced Grant 339787-NEXT; the Ministerio de Econom¿&#305;a y Competitividad of Spain under grants CONSOLIDERIngenio 2010 CSD2008-0037 (CUP), FIS2014-53371-C04 and the Severo Ochoa Program SEV-2014-0398; the Portuguese FCT and FEDER through the program COMPETE, project PTDC/FIS/103860/2008; the U.S. Department of Energy under contracts number DE-AC02-07CH11359 (Fermi National Accelerator Laboratory) and DE-FG02-13ER42020 (Texas A&M); and the University of Texas at Arlington. We thank Joshua B. Albert for useful discussions regarding the cosmogenic backgrounds.