Pasar al contenido principal

FISICA EXPERIMENTAL DE NEUTRINOS:EL PROYECTO NEXT

FPA2009-13697-C04-01

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Proyectos de Investigación Fundamental
Subprograma Subprograma de Proyectos de Investigación Fundamental no Orientada
Convocatoria Proyectos I+D
Año convocatoria 2009
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Proyectos de Investigación
Centro beneficiario UNIVERSITAT DE VALÈNCIA
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ionization and scintillation of nuclear recoils in gaseous xenon

  • Renner, J.
  • Gehman, V. M.
  • Goldschmidt, A.
  • Matis, H. S.
  • Miller, T.
  • Nakajima, Y.
  • Nygren, D.
  • Oliveira, C. A. B.
  • Shuman, D.
  • Alvarez, V.
  • Borges, F. I. G.
  • Carcel, S.
  • Castel, J.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Dafni, T.
  • Dias, T. H. V. T.
  • Diaz, J.
  • Evtoukhovitch, P.
  • Fernandes, L. M. P.
  • Ferrario, P.
  • Ferreira, A. L.
  • Freitas, E. D. C.
  • Gomez, H.
  • Gomez-Cadenas, J. J.
  • Gonzalez-Diaz, D.
  • Gutierrez, R. M.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrera, D. C.
  • Iguaz, F. J.
  • Irastorza, I. G.
  • Jinete, M. A.
  • Labarga, L.
  • Laing, A.
  • Liubarsky, I.
  • Lopes, J. A. M.
  • Lorca, D.
  • Losada, M.
  • Luzon, G.
  • Mari, A.
  • Martin-Albo, J.
  • Martinez, A.
  • Moiseenko, A.
  • Monrabal, F.
  • Monserrate, M.
  • Monteiro, C. M. B.
  • Moutinho, L. M.
  • Muñoz Vidal, J.
  • Natal da Luz, H.
  • Navarro, G.
  • Nebot-Guinot, M.
  • Palma, R.
  • Perez, J.
  • Pérez Aparicio, José Luis
  • Ripoll, L.
  • Rodriguez, A.
  • Rodriguez, J.
  • Santos, F. P.
  • dos Santos, J. M. F.
  • Segui, L.
  • Serra, L.
  • Simon, A.
  • Sofka, C.
  • Sorel, M.
  • Tomas, A.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J. F. C. A.
  • Villar, J. A.
  • Webb, R. C.
  • White, J.
  • Yahlali, N.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Gil, A.|||0000-0001-7192-6992
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
Abstract Ionization and scintillation produced by nuclear recoils in gaseous xenon at approximately 14 bar have been simultaneously observed in an electroluminescent time projection chamber. Neutrons from radioisotope α-Be neutron sources were used to induce xenon nuclear recoils, and the observed recoil spectra were compared to a detailed Monte Carlo employing estimated ionization and scintillation yields for nuclear recoils. The ability to discriminate between electronic and nuclear recoils using the ratio of ionization to primary scintillation is demonstrated. These results encourage further investigation on the use of xenon in the gas phase as a detector medium in dark matter direct detection experiments., This work was supported by the following agencies and institutions: the Director, Office of Science, Office of Basic Energy Sciences, of the U.S. Department of Energy, and the National Energy Research Scientific Computing Center (NERSC), supported by the Office of Science of the U.S. Department of Energy, both under Contract no. DE-AC02-05CH11231; the European Research Council under the Advanced Grant 339787-NEXT; the Ministerio de Economia y Competitividad of Spain under Grants CONSOLIDER-Ingenio 2010 C5D2008-0037 (CUP), FPA2009-13697-004-04, FPA2009-13697-C04-01, FIS2012-37947-C04-01, FIS2012-37947-C04-02, FIS2012-37947-C04-03, and FIS2012-37947-C04-04; and the Portuguese FCT and FEDER through the program COMPETE, Projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009. J. Renner acknowledges the support of a Department of Energy National Nuclear Security Administration Stewardship Science Graduate Fellowship, grant number DE-FC52-08NA28752.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Design and characterization of the SiPM tracking system of NEXT-DEMO, a demonstrator prototype of the NEXT-100 experiment

  • Alvarez, V.
  • Ball, M.
  • Borges, F. I. G.
  • Cárcel, S.
  • Castel, J.
  • Cebrian, S.
  • Cervera, A.
  • Conde, C. A. N.
  • Dafni, T.
  • Dias, T. H. V. T.
  • Marí Romero, Antonio Francisco
  • Palma, R.
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Pérez Aparicio, José Luis
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
NEXT-100 experiment aims at searching the neutrinoless double-beta decay of the Xe-136 isotope using a TPC filled with a 100 kg of high-pressure gaseous xenon, with 90% isotopic enrichment. The experiment will take place at the Laboratorio Subterraneo de Canfranc (LSC), Spain. NEXT-100 uses electroluminescence (EL) technology for energy measurement with a resolution better than 1% FWHM. The gaseous xenon in the TPC additionally allows the tracks of the two beta particles to be recorded, which are expected to have a length of up to 30 cm at 10 bar pressure. The ability to record the topological signature of the beta beta 0 nu events provides a powerful background rejection factor for the beta beta experiment. In this paper, we present a novel 3D imaging concept using SiPMs coated with tetraphenyl butadiene (TPB) for the EL read out and its first implementation in NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment. The design and the first characterization measurements of the NEXT-DEMO SiPM tracking system are presented. The SiPM response uniformity over the tracking plane drawn from its gain map is shown to be better than 4%. An automated active control system for the stabilization of the SiPMs gain was developed, based on the voltage supply compensation of the gain drifts. The gain is shown to be stabilized within 0.2% relative variation around its nominal value, provided by Hamamatsu, in a temperature range of 10 degrees C. The noise level from the electronics and the SiPM dark noise is shown to lay typically below the level of 10 photoelectrons (pe) in the ADC. Hence, a detection threshold at 10 pe is set for the acquisition of the tracking signals. The ADC full dynamic range (4096 channels) is shown to be adequate for signal levels of up to 200 pe/mu s, which enables recording most of the tracking signals. © 2013 IOP Publishing Ltd and Sissa Medialab srl., We acknowledge the Spanish MICINN for the Consolider-Ingenio 2010 under contract CSD2008-0037 (CUP) and for the research grants under contract FPA2008-03456, FPA2009-13697-C04-01 and FPA2009-13697-C04-04 part of which come from FEDER funds. The Portuguese teams acknowledge support from FCT and FEDER through program COMPETE, projects PTDC/FIS/103860/2008 and PTDC/FIS/112272/2009. J. Renner acknowledges the support of the U.S. Department of Energy Stewardship Science Graduate Fellowship, grant number DE-FC52-8NA28752.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Front-end electronics for accurate energy measurement of double beta decays

  • Gil, A.|||0000-0001-7192-6992
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Monzó Ferrer, José María|||0000-0001-6554-3231
  • Diaz, J.
  • Gómez-Cadenas, J.J.
  • Rodriguez, J.
  • Serra, L.
  • Monrabal, F.
  • Yahlali, N.
NEXT, a double beta decay experiment that will operate in Canfranc Underground Laboratory (Spain), aims at measuring the neutrinoless double-ß decay of the 136Xe isotope using a TPC filled with enriched Xenon gas at high pressure operated in electroluminescence mode. One technological challenge of the experiment is to achieve resolution better than 1% in the energy measurement using a plane of UV sensitive photomultipliers readout with appropriate custom-made front-end electronics. The front-end is designed to be sensitive to the single photo-electron to detect the weak primary scintillation light produced in the chamber, and also to be able to cope with the electroluminescence signal (several hundred times higher and with a duration of microseconds). For efficient primary scintillation detection and precise energy measurement of the electroluminescent signals the front-end electronics features low noise and adequate amplification. The signal shaping provided allows the digitization of the signals at a frequency as low as 40 MHz. © 2011 Elsevier B.V., We thank H. Spieler for his invaluable support and advice. Also, we acknowledge the support of the NEXT Collaboration, the CONSOLIDER-INGENIO2010 grant CSD2008-0037 (CUP) and MICINN under grant FPA2009-13697-C04-01.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

SiPMs coated with TPB: coating protocol and characterization for NEXT

  • Alvarez, V.
  • Agramunt, J.
  • Ball, M.
  • Batalle, M.
  • Bayarri, J.
  • Borges, F. I. G.
  • Bolink, H.
  • Català Pérez, Joan Marc
  • Marí Romero, Antonio Francisco
  • Pérez Aparicio, José Luis
  • Esteve Bosch, Raul|||0000-0002-1289-6938
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Monzó Ferrer, José María|||0000-0001-6554-3231
  • Mora Mas, Francisco José|||0000-0003-2281-9546
  • Toledo Alarcón, José Francisco|||0000-0002-9782-4510
[EN] Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking readout in NEXT, a neutrinoless \bb decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs offer important advantages, mainly high gain, ruggedness, cost-effectiveness and radio-purity. Their main drawback, however, is their non sensitivity in the emission spectrum of the xenon scintillation (peak at 175 nm). This is overcome by coating these sensors with the organic wavelength shifter tetraphenyl butadiene (TPB). In this paper we describe the protocol developed for coating the SiPMs with TPB and the measurements performed for characterizing the coatings as well as the performance of the coated sensors in the UV-VUV range. © 2012 IOP Publishing Ltd and SISSA., We acknowledge the Spanish MICINN for the Consolider Ingenio grants under contracts CSD2008-00037, CSD2007-00042 and CSD2007-00010 and for the research grants under contract FPA2008-03456 and FPA2009-13697-C04-01 part of which come from FEDER funds. The Portuguese team acknowledges support from FCT and FEDER through program COMPETE, project PTDC/FIS/103860/2008. J. Renner acknowledges the support of the U.S. Department of Energy Stewardship Science Graduate Fellowship, grant number DE-FC52-08NA28752.