Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 18
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Fluorescent bicolour sensor for low-background neutrinoless double β decay experiments

  • Rivilla, Iván
  • Aparicio, Borja
  • Bueno, J. M.
  • Casanova, David
  • Tonnelé, Claire
  • Freixa, Zoraida
  • Herrero-Gómez, P.
  • Rogero, Celia
  • Miranda, José Ignacio
  • Martínez-Ojeda, Rosa M.
  • Monrabal, Francesc
  • Olave, Beñat
  • Schäfer, Thomas
  • Artal, Pablo
  • Nygren, David
  • Cossío, Fernando P.
  • Gómez Cadenas, Juan José
Observation of the neutrinoless double β decay is the only practical way to establish that neutrinos are their own antiparticles. Because of the small masses of neutrinos, the lifetime of neutrinoless double β decay is expected to be at least ten orders of magnitude greater than the typical lifetimes of natural radioactive chains, which can mimic the experimental signature of neutrinoless double β decay. The most robust identification of neutrinoless double β decay requires the definition of a signature signal—such as the observation of the daughter atom in the decay—that cannot be generated by radioactive backgrounds, as well as excellent energy resolution. In particular, the neutrinoless double β decay of Xe could be established by detecting the daughter atom, Ba, in its doubly ionized state. Here we demonstrate an important step towards a ‘barium-tagging’ experiment, which identifies double β decay through the detection of a single Ba ion. We propose a fluorescent bicolour indicator as the core of a sensor that can detect single Ba ions in a high-pressure xenon gas detector. In a sensor made of a monolayer of such indicators, the Ba dication would be captured by one of the molecules and generate a Ba-coordinated species with distinct photophysical properties. The presence of such a single Ba-coordinated indicator would be revealed by its response to repeated interrogation with a laser system, enabling the development of a sensor able to detect single Ba ions in high-pressure xenon gas detectors for barium-tagging experiments., We also acknowledge support from the following agencies and institutions: the European Research Council (ERC) under Advanced Grant 339787-NEXT; the Ministry of Science and Innovation of Spain and FEDER under grants FIS2014-53371-C04, FIS2016-76163-R, MAT2016-78293-C6-5-R, MINECO/FEDER CT2016-80955-P, CTQ2016-80375-P and CTQ2014-51912-REDC; Interred PCTEFA V-A Spain/France/Andorra Program (EFA 194/16/TNSI); the Basque Government (GV/EJ) under grants IT-1346-19 and IT-1180-19; andAgencia de Ciencia y Tecnología de la Región de Murcia (19897/GERM/15). The authors also thank the SGI/IZO-SGIker UPV/EHU, Fundación Séneca and DIPC for computational and analytical resources.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Sensitivity of NEXT-100 to neutrinoless double beta decay

  • The, NEXT collaboration
  • Martín-Albo, J.
  • Muñoz Vidal, J.
  • Ferrario, P.
  • Nebot-Guinot, M.
  • Gómez-Cadenas, J.J.
  • Álvarez, V.
  • Azevedo, C.D.R.
  • Borges, F.I.G.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Goldschmidt, A.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernando Morata, J.A.
  • Herrero, V.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • Liubarsky, I.
  • López-March, N.
  • Lorca, D.
  • Losada, M.
  • Martínez-Lema, G.
  • Martínez, A.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Novella, P.
  • Nygren, D.
  • Palmeiro, B.
  • Para, A.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
  • Yepes-Ramírez, H.
NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta (0¿ßß) decay of 136Xe. The detector possesses two features of great value for 0¿ßß searches: energy resolution better than 1% FWHM at the Q value of 136Xe and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Material-screening measurements and a detailed Monte Carlo detector simulation predict a background rate for NEXT-100 of at most 4 × 10-4 counts keV-1 kg-1 yr-1. Accordingly, the detector will reach a sensitivity to the 0¿ßß-decay half-life of 2.8 × 1025 years (90% CL) for an exposure of 100 kg·year, or 6.0 × 1025 years after a run of 3 effective years.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The NEXT double beta decay experiment

  • A Laing on behalf of the NEXT collaboration
  • Cebrian, S
NEXT (Neutrino Experiment with a Xenon TPC) is a neutrinoless double- beta (ßß0¿) decay experiment at Laboratorio Subterra ´neo de Canfranc (LSC). It is an electroluminescent Time Projection Chamber filled with high pressure 136Xe gas with separated function capabilities for calorimetry and tracking. Energy resolution and background suppression are the two key features of any neutrinoless double beta decay experiment. NEXT has both good energy resolution (< 1% FWHM) and an extra handle for background identification provided by track reconstruction. We expect a background rate of 4 × 10-4 counts keV-1 kg-1 yr-1, and a sensitivity to the Majorana neutrino mass of between 80–160 meV (depending on NME) after a run of 3 effective years of the 100 kg scale NEXT-100 detector. The initial phase of NEXT-100, called NEW, is currently being commissioned at LSC. It will validate the NEXT background rate expectations and will make first measurements of the two neutrino ßß2¿ mode of 136Xe. Furthermore, the NEXT technique can be extrapolated to the tonne scale, thus allowing the full exploration of the inverted hierarchy of neutrino masses. These proceedings review NEXT R&D results, the status of detector commissioning at LSC and the NEXT physics case.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Background rejection in NEXT using deep neural networks

  • Renner, J.
  • Farbin, A.
  • Vidal, J.M.
  • Benlloch-Rodríguez, J.M.
  • Botas, A.
  • Ferrario, P.
  • Gómez-Cadenas, J.J.
  • Álvarez, V.
  • Azevedo, C.D.R.
  • Borges, F.I.G.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Cervera, A.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Esteve, R.
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Goldschmidt, A.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Morata, J.A.H.
  • Herrero, V.
  • Jones, B.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • Liubarsky, I.
  • López-March, N.
  • Lorca, D.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Ripoll, L.
  • Rodríguez, J.
  • Santos, F.P.
  • Dos Santos, J.M.F.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • White, J.
  • Webb, R.
  • Yahlali, N.
  • Yepes-Ramírez, H.
We investigate the potential of using deep learning techniques to reject background events in searches for neutrinoless double beta decay with high pressure xenon time projection chambers capable of detailed track reconstruction. The differences in the topological signatures of background and signal events can be learned by deep neural networks via training over many thousands of events. These networks can then be used to classify further events as signal or background, providing an additional background rejection factor at an acceptable loss of efficiency. The networks trained in this study performed better than previous methods developed based on the use of the same topological signatures by a factor of 1.2 to 1.6, and there is potential for further improvement.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Secondary scintillation yield of xenon with sub-percent levels of CO2 additive for rare-event detection

  • Henriques, C.A.O.
  • Freitas, E.D.C.
  • Azevedo, C.D.R.
  • González-Díaz, D.
  • Mano, R.D.P.
  • Jorge, M.R.
  • Fernandes, L.M.P.
  • Monteiro, C.M.B.
  • Gómez-Cadenas, J.J.
  • Álvarez, V.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel, S.
  • Carríon, J.V.
  • Cebrían, S.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Esteve, R.
  • Felkai, R.
  • Ferrario, P.
  • Ferreira, A.L.
  • Goldschmidt, A.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernandez, A.I.
  • Hernando Morata, J.A.
  • Herrero, V.
  • Jones, B.J.P.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • Liubarsky, I.
  • López-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • McDonald, A.D.
  • Monrabal, F.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Musti, M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Rogers, L.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
Xe–CO2 mixtures are important alternatives to pure xenon in Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification with applications in the important field of rare event detection such as directional dark matter, double electron capture and double beta decay detection. The addition of CO2 to pure xenon at the level of 0.05–0.1% can reduce significantly the scale of electron diffusion from 10 mm/m to 2.5 mm/m, with high impact on the discrimination efficiency of the events through pattern recognition of the topology of primary ionization trails. We have measured the electroluminescence (EL) yield of Xe–CO2 mixtures, with sub-percent CO2 concentrations. We demonstrate that the EL production is still high in these mixtures, 70% and 35% relative to that produced in pure xenon, for CO2 concentrations around 0.05% and 0.1%, respectively. The contribution of the statistical fluctuations in EL production to the energy resolution increases with increasing CO2 concentration, being smaller than the contribution of the Fano factor for concentrations below 0.1% CO2.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Demonstration of Single-Barium-Ion Sensitivity for Neutrinoless Double-Beta Decay Using Single-Molecule Fluorescence Imaging

  • McDonald, A.D.
  • Jones, B.J.P.
  • Nygren, D.R.
  • Adams, C.
  • Álvarez, V.
  • Azevedo, C.D.R.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Guenette, R.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernandez, A.I.
  • Hernando Morata, J.A.
  • Herrero, V.
  • Johnston, S.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • Liubarsky, I.
  • López-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Muñoz Vidal, J.
  • Musti, M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Repond, J.
  • Renner, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez, J.
  • Rogers, L.
  • Santos, F.P.
  • Dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
A new method to tag the barium daughter in the double-beta decay of Xe136 is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba++) resolution at a transparent scanning surface is demonstrated. A single-step photobleach confirms the single ion interpretation. Individual ions are localized with superresolution (~2 nm), and detected with a statistical significance of 12.9s over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double-beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Measurement of radon-induced backgrounds in the NEXT double beta decay experiment

  • Novella, P.
  • Palmeiro, B.
  • Simón, A.
  • Sorel, M.
  • Adams, C.
  • Ferrario, P.
  • Martínez-Lema, G.
  • Monrabal, F.
  • Zuzel, G.
  • Gómez-Cadenas, J.J.
  • Álvarez, V.
  • Arazi, L.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Goldschmidt, A.
  • González-Díaz, D.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernandez, A.I.
  • Hernando Morata, J.A.
  • Herrero, V.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martíin-Albo, J.
  • Martínez, A.
  • McDonald, A.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Musti, M.
  • Nebot-Guinot, M.
  • Nygren, D.R.
  • Para, A.
  • Pérez, J.
  • Psihas, F.
  • Querol, M.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez, J.
  • Rogers, L.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Sofka, C.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
  • The, NEXT, collaboration
The measurement of the internal 222Rn activity in the NEXT-White detector during the so-called Run-II period with 136Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by 222Rn and its alpha-emitting progeny. The specific activity is measured to be (38.1 ± 2.2 (stat.) ± 5.9 (syst.)) mBq/m3. Radon-induced electrons have also been characterized from the decay of the 214Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.1 counts/yr in the neutrinoless double beta decay sample.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The NEXT White (NEW) detector

  • Monrabal, F.
  • Gomez-Cadenas, J.J.
  • Toledo, J.F.
  • Laing, A.
  • Alvarez, V.
  • Benlloch-Rodriguez, J.M.
  • Carcel, S.
  • Carrion, J.
  • Esteve, R.
  • Felkai, R.
  • Herrero, V.
  • Martinez, A.
  • Musti, M.
  • Ouero, M.
  • Rodriguez, J.
  • Simon, A.
  • Sofka, C.
  • Torrent, J.
  • Webb, R.
  • White, J.T.
  • Adams, C.
  • Arazi, L.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cebrian, S.
  • Conde, C.A.N.
  • Diaz, J.
  • Diesburg, M.
  • Escada, J.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferrario, I.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Goldschmidt, A.
  • Gonzalez-Daaz, D.
  • Guenette, R.
  • Gutierrez, R.M.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernandez, A.I.
  • Morata, J.A.H.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Lebrun, P.
  • Lopez-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martin-Albo, J.
  • Martinez-Lema, G.
  • McDonald, A.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Vidal, J.M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Perez, J.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rogers, L.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Sorel, M.
  • Stiegler, T.
  • Veloso, J.F.C.A.
  • Yahlali, N.
Conceived to host 5 kg of xenon at a pressure of 15 bar in the fiducial volume, the NEXT-White apparatus is currently the largest high pressure xenon gas TPC using electroluminescent amplification in the world. It is also a 1:2 scale model of the NEXT-100 detector for Xe-136 beta beta 0 nu decay searches, scheduled to start operations in 2019. Both detectors measure the energy of the event using a plane of photomultipliers located behind a transparent cathode. They can also reconstruct the trajectories of charged tracks in the dense gas of the TPC with the help of a plane of silicon photomultipliers located behind the anode. A sophisticated gas system, common to both detectors, allows the high gas purity needed to guarantee a long electron lifetime. NEXT-White has been operating since October 2016 at the Laboratorio Subterraneo de Canfranc (LSC), in Spain. This paper describes the detector and associated infrastructures, as well as the main aspects of its initial operation.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Electroluminescence TPCs at the thermal diffusion limit

  • Henriques, C.A.O.
  • Monteiro, C.M.B.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Freitas, E.D.C.
  • Mano, R.D.P.
  • Jorge, M.R.
  • Fernandes, A.F.M.
  • Gómez-Cadenas, J.J.
  • Fernandes, L.M.P.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Ferrario, P.
  • Ferreira, A.L.
  • Generowicz, J.
  • Goldschmidt, A.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Hafidi, K.
  • Hauptman, J.
  • Hernandez, A.I.
  • Hernando Morata, J.A.
  • Herrero, V.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • McDonald, A.
  • Monrabal, F.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Musti, M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Psihas, F.
  • Querol, M.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez, J.
  • Rogers, L.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
The NEXT experiment aims at searching for the hypothetical neutrinoless double-beta decay from the 136Xe isotope using a high-purity xenon TPC. Efficient discrimination of the events through pattern recognition of the topology of primary ionisation tracks is a major requirement for the experiment. However, it is limited by the diffusion of electrons. It is known that the addition of a small fraction of a molecular gas to xenon reduces electron diffusion. On the other hand, the electroluminescence (EL) yield drops and the achievable energy resolution may be compromised. We have studied the effect of adding several molecular gases to xenon (CO2, CH4 and CF4) on the EL yield and energy resolution obtained in a small prototype of driftless gas proportional scintillation counter. We have compared our results on the scintillation characteristics (EL yield and energy resolution) with a microscopic simulation, obtaining the diffusion coefficients in those conditions as well. Accordingly, electron diffusion may be reduced from about 10 mm/m for pure xenon down to 2.5 mm/m using additive concentrations of about 0.05%, 0.2% and 0.02% for CO2, CH4 and CF4, respectively. Our results show that CF4 admixtures present the highest EL yield in those conditions, but very poor energy resolution as a result of huge fluctuations observed in the EL formation. CH4 presents the best energy resolution despite the EL yield being the lowest. The results obtained with xenon admixtures are extrapolated to the operational conditions of the NEXT-100 TPC. CO2 and CH4 show potential as molecular additives in a large xenon TPC. While CO2 has some operational constraints, making it difficult to be used in a large TPC, CH4 shows the best performance and stability as molecular additive to be used in the NEXT-100 TPC, with an extrapolated energy resolution of 0.4% at 2.45 MeV for concentrations below 0.4%, which is only slightly worse than the one obtained for pure xenon. We demonstrate the possibility to have an electroluminescence TPC operating very close to the thermal diffusion limit without jeopardizing the TPC performance, if CO2 or CH4 are chosen as additives.[Figure not available: see fulltext.]
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Microscopic simulation of xenon-based optical TPCs in the presence of molecular additives

  • Azevedo, C.D.R.
  • González-Díaz, D.
  • Biagi, S.F.
  • Oliveira, C.A.B.
  • Henriques, C.A.O.
  • Escada, J.
  • Monrabal, F.
  • Gómez-Cadenas, J.J.
  • Álvarez, V.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Botas, A.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Conde, C.A.N.
  • Díaz, J.
  • Diesburg, M.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Goldschmidt, A.
  • Gutiérrez, R.M.
  • Hauptman, J.
  • Hernandez, A.I.
  • Morata, J.A.H.
  • Herrero, V.
  • Jones, B.J.P.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • Liubarsky, I.
  • Lopez-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez-Lema, G.
  • Martínez, A.
  • McDonald, A.D.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Moutinho, L.M.
  • Vidal, J.M.
  • Musti, M.
  • Nebot-Guinot, M.
  • Novella, P.
  • Nygren, D.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Renner, J.
  • Ripoll, L.
  • Rodríguez, J.
  • Rogers, L.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Serra, L.
  • Shuman, D.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Tsamalaidze, Z.
  • Veloso, J.F.C.A.
  • Webb, R.
  • White, J.T.
  • Yahlali, N.
We introduce a simulation framework for the transport of high and low energy electrons in xenon-based optical time projection chambers (OTPCs). The simulation relies on elementary cross sections (electron–atom and electron–molecule) and incorporates, in order to compute the gas scintillation, the reaction/quenching rates (atom–atom and atom–molecule) of the first 41 excited states of xenon and the relevant associated excimers, together with their radiative cascade. The results compare positively with observations made in pure xenon and its mixtures with CO2 and CF4 in a range of pressures from 0.1 to 10 bar. This work sheds some light on the elementary processes responsible for the primary and secondary xenon-scintillation mechanisms in the presence of additives, that are of interest to the OTPC technology.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Radiogenic backgrounds in the NEXT double beta decay experiment

  • Novella P.
  • Palmeiro B.
  • Sorel M.
  • Usón A.
  • Ferrario P.
  • Gómez-Cadenas J.J.
  • Adams C.
  • Álvarez V.
  • Arazi L.
  • Arnquist I.J.
  • Azevedo C.D.R.
  • Bailey K.
  • Ballester F.
  • Benlloch-Rodríguez J.M.
  • Borges F.I.G.M.
  • Byrnes N.
  • Cárcel S.
  • Carrión J.V.
  • Cebrían S.
  • Church E.
  • Conde C.A.N.
  • Contreras T.
  • Díaz G.
  • Díaz J.
  • Diesburg M.
  • Escada J.
  • Esteve R.
  • Felkai R.
  • Fernandes A.F.M.
  • Fernandes L.M.P.
  • Ferreira A.L.
  • Freitas E.D.C.
  • Generowicz J.
  • Ghosh S.
  • Goldschmidt A.
  • Gonzalez-Díaz D.
  • Guenette R.
  • Gutiérrez R.M.
  • Haefner J.
  • Hafidi K.
  • Hauptman J.
  • Henriques C.A.O.
  • Hernando Morata J.A.
  • Herrero P.
  • Herrero V.
  • Ifergan Y.
  • Johnston S.
  • Jones B.J.P.
  • Kekic M.
  • Labarga L.
  • Laing A.
  • Lebrun P.
  • López-March N.
  • Losada M.
  • Mano R.D.P.
  • Martín-Albo J.
  • Martínez A.
  • Martínez-Lema G.
  • McDonald A.D.
  • Monrabal F.
  • Monteiro C.M.B.
  • Mora F.J.
  • Muñoz Vidal J.
  • Nygren D.R.
  • Para A.
  • Pérez J.
  • Psihas F.
  • Querol M.
  • Renner J.
  • Repond J.
  • Riordan S.
  • Ripoll L.
  • Rodríguez García Y.
  • Rodríguez J.
  • Rogers L.
  • Romeo B.
  • Romo-Luque C.
  • Santos F.P.
  • dos Santos J.M.F.
  • Simón A.
  • Sofka C.
  • Stiegler T.
  • Toledo J.F.
  • Torrent J.
  • Veloso J.F.C.A.
  • Webb R.
  • Weiss-Babai R.
  • White J.T.
  • Woodruff K.
  • Yahlali N.
  • The NEXT collaboration
Natural radioactivity represents one of the main backgrounds in the search for neutrinoless double beta decay. Within the NEXT physics program, the radioactivity- induced backgrounds are measured with the NEXT-White detector. Data from 37.9 days of low-background operations at the Laboratorio Subterráneo de Canfranc with xenon depleted in 136Xe are analyzed to derive a total background rate of (0.84±0.02) mHz above 1000 keV. The comparison of data samples with and without the use of the radon abatement system demonstrates that the contribution of airborne-Rn is negligible. A radiogenic background model is built upon the extensive radiopurity screening campaign conducted by the NEXT collaboration. A spectral fit to this model yields the specific contributions of 60Co, 40K, 214Bi and 208Tl to the total background rate, as well as their location in the detector volumes. The results are used to evaluate the impact of the radiogenic backgrounds in the double beta decay analyses, after the application of topological cuts that reduce the total rate to (0.25±0.01) mHz. Based on the best-fit background model, the NEXT-White median sensitivity to the two-neutrino double beta decay is found to be 3.5s after 1 year of data taking. The background measurement in a Qßß±100 keV energy window validates the best-fit background model also for the neutrinoless double beta decay search with NEXT-100. Only one event is found, while the model expectation is (0.75±0.12) events.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Energy calibration of the NEXT-White detector with 1% resolution near Qßß of 136Xe

  • Renner, J.
  • Díaz López, G.
  • Ferrario, P.
  • Hernando Morata, J.A.
  • Kekic, M.
  • Martínez-Lema, G.
  • Monrabal, F.
  • Gómez-Cadenas, J.J.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • González-Díaz, D.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Jones, B.J.P.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martín-Albo, J.
  • Martínez, A.
  • McDonald, A.D.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Psihas, F.
  • Querol, M.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez García, Y.
  • Rodríguez, J.
  • Rogers, L.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
  • The NEXT collaboration
Excellent energy resolution is one of the primary advantages of electroluminescent high-pressure xenon TPCs. These detectors are promising tools in searching for rare physics events, such as neutrinoless double-beta decay (ßß0¿), which require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for ßß0¿ searches. [Figure not available: see fulltext.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Demonstration of the event identification capabilities of the NEXT-White detector

  • Ferrario P.
  • Benlloch-Rodríguez J.M.
  • Díaz López G.
  • Hernando Morata J.A.
  • Kekic M.
  • Renner J.
  • Usón A.
  • Gómez-Cadenas J.J.
  • Adams C.
  • Álvarez V.
  • Arazi L.
  • Arnquist I.J.
  • Azevedo C.D.R.
  • Bailey K.
  • Ballester F.
  • Borges F.I.G.M.
  • Byrnes N.
  • Cárcel S.
  • Carrión J.V.
  • Cebrían S.
  • Church E.
  • Conde C.A.N.
  • Contreras T.
  • Díaz J.
  • Diesburg M.
  • Escada J.
  • Esteve R.
  • Felkai R.
  • Fernandes A.F.M.
  • Fernandes L.M.P.
  • Ferreira A.L.
  • Freitas E.D.C.
  • Generowicz J.
  • Ghosh S.
  • Goldschmidt A.
  • González-Díaz D.
  • Guenette R.
  • Gutíerrez R.M.
  • Haefner J.
  • Hafidi K.
  • Hauptman J.
  • Henriques C.A.O.
  • Herrero P.
  • Herrero V.
  • Ifergan Y.
  • Johnston S.
  • Jones B.J.P.
  • Labarga L.
  • Laing A.
  • Lebrun P.
  • López-March N.
  • Losada M.
  • Mano R.D.P.
  • Martín-Albo J.
  • Martínez A.
  • Martínez-Lema G.
  • McDonald A.D.
  • Monrabal F.
  • Monteiro C.M.B.
  • Mora F.J.
  • Muñoz Vidal J.
  • Novella P.
  • Nygren D.R.
  • Palmeiro B.
  • Para A.
  • Pérez J.
  • Psihas F.
  • Querol M.
  • Repond J.
  • Riordan S.
  • Ripoll L.
  • Rodríguez García Y.
  • Rodríguez J.
  • Rogers L.
  • Romeo B.
  • Romo-Luque C.
  • Santos F.P.
  • dos Santos J.M.F.
  • Simón A.
  • Sofka C.
  • Sorel M.
  • Stiegler T.
  • Toledo J.F.
  • Torrent J.
  • Veloso J.F.C.A.
  • Webb R.
  • Weiss-Babai R.
  • White J.T.
  • Woodruff K.
  • Yahlali N.
  • The NEXT collaboration
In experiments searching for neutrinoless double-beta decay, the possibility of identifying the two emitted electrons is a powerful tool in rejecting background events and therefore improving the overall sensitivity of the experiment. In this paper we present the first measurement of the efficiency of a cut based on the different event signatures of double and single electron tracks, using the data of the NEXT-White detector, the first detector of the NEXT experiment operating underground. Using a 228Th calibration source to produce signal-like and background-like events with energies near 1.6 MeV, a signal efficiency of 71.6 ± 1.5 stat± 0.3 sys% for a background acceptance of 20.6 ± 0.4 stat± 0.3 sys% is found, in good agreement with Monte Carlo simulations. An extrapolation to the energy region of the neutrinoless double beta decay by means of Monte Carlo simulations is also carried out, and the results obtained show an improvement in background rejection over those obtained at lower energies. [Figure not available: see fulltext.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

  • Fernandes, A.F.M.
  • Henriques, C.A.O.
  • Mano, R.D.P.
  • González-Díaz, D.
  • Azevedo, C.D.R.
  • Silva, P.A.O.C.
  • Gómez-Cadenas, J.J.
  • Freitas, E.D.C.
  • Fernandes, L.M.P.
  • Monteiro, C.M.B.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, G.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Ferrario, P.
  • Ferreira, A.L.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Hernando Morata, J.A.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • McDonald, A.D.
  • Monrabal, F.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Psihas, F.
  • Querol, M.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez García, Y.
  • Rodríguez, J.
  • Rogers, L.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
  • The NEXT collaboration
High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffu- sion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe–He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the EL region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Dependence of polytetrafluoroethylene reflectance on thickness at visible and ultraviolet wavelengths in air

  • Ghosh, S.
  • Haefner, J.
  • Martín-Albo, J.
  • Guenette, R.
  • Li, X.
  • Loya Villalpando, A.A.
  • Burch, C.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, G.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Gutiérrez, R.M.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernando Morata, J.A.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martínez, A.
  • Martínez-Vara, M.
  • Martínez-Lema, G.
  • McDonald, A.D.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Redwine, A.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez García, Y.
  • Rodríguez, J.
  • Rogers, L.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
  • The, NEXT, collaboration
Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. However, the reflectance of PTFE is a function of its thickness. In this work, we investigate this dependence in air for light of wavelengths 260 nm and 450 nm using two complementary methods. We find that PTFE reflectance for thicknesses from 5 mm to 10 mm ranges from 92.5% to 94.5% at 450 nm, and from 90.0% to 92.0% at 260 nm. We also see that the reflectance of PTFE of a given thickness can vary by as much as 2.7% within the same piece of material. Finally, we show that placing a specular reflector behind the PTFE can recover the loss of reflectance in the visible without introducing a specular component in the reflectance.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Mitigation of backgrounds from cosmogenic 137Xe in xenon gas experiments using 3He neutron capture

  • Rogers, L.
  • Jones, B.J.P.
  • Laing, A.
  • Pingulkar, S.
  • Smithers, B.
  • Woodruff, K.
  • Adams, C.
  • Lvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, G.
  • Díaz, J.
  • Diesburg, M.
  • Dingler, R.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Morata, J.A.H.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Kekic, M.
  • Labarga, L.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martín-Albo, J.
  • Martínez, A.
  • Martínez-Lema, G.
  • McDonald, A.D.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Vidal, J.M.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Redwine, A.B.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • García, Y.R.
  • Rodríguez, J.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • Dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Sorel, M.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Yahlali, N.
136Xe is used as the target medium for many experiments searching for 0¿ßß. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential background that is difficult to veto using muon tagging comes in the form of 137Xe created by the capture of neutrons on 136Xe. This isotope decays via beta decay with a half-life of 3.8 min and a Q ß of ~4.16 MeV. This work proposes and explores the concept of adding a small percentage of 3He to xenon as a means to capture thermal neutrons and reduce the number of activations in the detector volume. When using this technique we find the contamination from 137Xe activation can be reduced to negligible levels in tonne and multi-tonne scale high pressure gas xenon neutrinoless double beta decay experiments running at any depth in an underground laboratory.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Sensitivity of the NEXT experiment to Xe-124 double electron capture

  • Martínez-Lema, G.
  • Martínez-Vara, M.
  • Sorel, M.
  • Adams, C.
  • Álvarez, V.
  • Arazi, L.
  • Arnquist, I.J.
  • Azevedo, C.D.R.
  • Bailey, K.
  • Ballester, F.
  • Benlloch-Rodríguez, J.M.
  • Borges, F.I.G.M.
  • Byrnes, N.
  • Cárcel, S.
  • Carrión, J.V.
  • Cebrián, S.
  • Church, E.
  • Conde, C.A.N.
  • Contreras, T.
  • Díaz, G.
  • Díaz, J.
  • Diesburg, M.
  • Escada, J.
  • Esteve, R.
  • Felkai, R.
  • Fernandes, A.F.M.
  • Fernandes, L.M.P.
  • Ferrario, P.
  • Ferreira, A.L.
  • Freitas, E.D.C.
  • Generowicz, J.
  • Ghosh, S.
  • Goldschmidt, A.
  • Gómez-Cadenas, J.J.
  • González-Díaz, D.
  • Guenette, R.
  • Gutiérrez, R.M.
  • Haefner, J.
  • Hafidi, K.
  • Hauptman, J.
  • Henriques, C.A.O.
  • Hernando Morata, J.A.
  • Herrero, P.
  • Herrero, V.
  • Ifergan, Y.
  • Johnston, S.
  • Jones, B.J.P.
  • Kekic, M.
  • Labarga, L.
  • Laing, A.
  • Lebrun, P.
  • López-March, N.
  • Losada, M.
  • Mano, R.D.P.
  • Martín-Albo, J.
  • Martínez, A.
  • McDonald, A.D.
  • Monrabal, F.
  • Monteiro, C.M.B.
  • Mora, F.J.
  • Muñoz Vidal, J.
  • Novella, P.
  • Nygren, D.R.
  • Palmeiro, B.
  • Para, A.
  • Pérez, J.
  • Querol, M.
  • Redwine, A.B.
  • Renner, J.
  • Repond, J.
  • Riordan, S.
  • Ripoll, L.
  • Rodríguez García, Y.
  • Rodríguez, J.
  • Rogers, L.
  • Romeo, B.
  • Romo-Luque, C.
  • Santos, F.P.
  • dos Santos, J.M.F.
  • Simón, A.
  • Sofka, C.
  • Stiegler, T.
  • Toledo, J.F.
  • Torrent, J.
  • Usón, A.
  • Veloso, J.F.C.A.
  • Webb, R.
  • Weiss-Babai, R.
  • White, J.T.
  • Woodruff, K.
  • Yahlali, N.
  • The, NEXT, collaboration
Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture (2¿EC EC) has been predicted for a number of isotopes, but only observed in 78Kr, 130Ba and, recently, 124Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, 0¿EC EC. Here we report on the current sensitivity of the NEXT-White detector to 124Xe 2¿EC EC and on the extrapolation to NEXT-100. Using simulated data for the 2¿EC EC signal and real data from NEXT-White operated with 124Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124Xe and for a 5-year run, a sensitivity to the 2¿EC EC half-life of 6 × 1022 y (at 90% confidence level) or better can be reached. [Figure not available: see fulltext.]
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Sensitivity of a tonne-scale NEXT detector for neutrinoless double-beta decay searches

  • Adams C.
  • Álvarez V.
  • Arazi L.
  • Arnquist I.J.
  • Azevedo C.D.R.
  • Bailey K.
  • Ballester F.
  • Benlloch-Rodríguez J.M.
  • Borges F.I.G.M.
  • Byrnes N.
  • Cárcel S.
  • Carrión J.V.
  • Cebrián S.
  • Church E.
  • Conde C.A.N.
  • Contreras T.
  • Denisenko A.A.
  • Díaz G.
  • Díaz J.
  • Escada J.
  • Esteve R.
  • Felkai R.
  • Fernandes L.M.P.
  • Ferrario P.
  • Ferreira A.L.
  • Foss F.
  • Freitas E.D.C.
  • Freixa Z.
  • Generowicz J.
  • Goldschmidt A.
  • Gómez-Cadenas J.J.
  • González R.
  • González-Díaz D.
  • Gosh S.
  • Guenette R.
  • Gutiérrez R.M.
  • Haefner J.
  • Hafidi K.
  • Hauptman J.
  • Henriques C.A.O.
  • Hernando Morata J.A.
  • Herrero P.
  • Herrero V.
  • Ho J.
  • Ifergan Y.
  • Jones B.J.P.
  • Kekic M.
  • Labarga L.
  • Laing A.
  • Lebrun P.
  • López-March N.
  • Losada M.
  • Mano R.D.P.
  • Martín-Albo J.
  • Martínez A.
  • Martínez-Vara M.
  • Martínez-Lema G.
  • McDonald A.D.
  • Meziani Z.E.
  • Monrabal F.
  • Monteiro C.M.B.
  • Mora F.J.
  • Muñoz Vidal J.
  • Newhouse C.
  • Novella P.
  • Nygren D.R.
  • Oblak E.
  • Palmeiro B.
  • Para A.
  • Pérez J.
  • Querol M.
  • Redwine A.
  • Renner J.
  • Ripoll L.
  • Rivilla I.
  • Rodríguez García Y.
  • Rodríguez J.
  • Rogero C.
  • Rogers L.
  • Romeo B.
  • Romo-Luque C.
  • Santos F.P.
  • dos Santos J.M.F.
  • Simón A.
  • Sorel M.
  • Stanford C.
  • Teixeira J.M.R.
  • Thapa P.
  • Toledo J.F.
  • Torrent J.
  • Usón A.
  • Veloso J.F.C.A.
  • Vuong T.T.
  • Webb R.
  • Weiss-Babai R.
  • White J.T.
  • Woodruff K.
  • Yahlali N.
  • The NEXT collaboration
The Neutrino Experiment with a Xenon TPC (NEXT) searches for the neutrinoless double-beta (0¿ßß) decay of 136Xe using high-pressure xenon gas TPCs with electroluminescent amplification. A scaled-up version of this technology with about 1 tonne of enriched xenon could reach in less than 5 years of operation a sensitivity to the half-life of 0¿ßß decay better than 1027 years, improving the current limits by at least one order of magnitude. This prediction is based on a well-understood background model dominated by radiogenic sources. The detector concept presented here represents a first step on a compelling path towards sensitivity to the parameter space defined by the inverted ordering of neutrino masses, and beyond. [Figure not available: see fulltext.] © 2021, The Author(s).