RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Results of a combined monolithic crystal and an array of ASICs controlled SiPMs

  • Conde Castellanos, Pablo Eloy
  • González Martínez, Antonio Javier
  • Hernández Hernández, Liczandro
  • Bellido, P.
  • Iborra Carreres, Amadeo
  • Crespo Navarro, Efren
  • Moliner Martínez, Laura
  • Rigla, JP.
  • Sánchez, F.
  • Seimetz, Michael
  • Soriano Asensi, Antonio
  • Vidal San Sebastián, Luis Fernando
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] In this work we present the energy and spatial resolutions we have obtained for a γ ray detector based on a monolithic LYSO crystal coupled to an array of 256 SiPMs. Two crystal configurations of the same trapezoidal shape have been tried. In one approach all surfaces were black painted but the exit one facing the photosensor array which was polished. The other approach included a retroreflector (RR) layer coupled to the entrance face of the crystal powering the amount of transmitted light to the photosensors. Two coupling media between the scintillator and the SiPM array were used, namely direct coupling by means of optical grease and coupling through an array of light guides. Since the same operational voltage was supplied to the entire array, it was needed to equalize their gains before feeding their signals to the Data Acquisition system. Such a job was performed by means of 4 scalable Application Specific Circuits (ASICs). An energy resolution of about 24.4% has been achieved for the direct coupling with the RR layer together with a spatial resolution of approximately 2.9 mm at the detector center. With the light guides coupling the effects of image compression at the edges are significantly minimized, but worsening the energy resolution to about 33.1% with a spatial resolution nearing 4 mm at the detector center. & 2013 Elsevier B.V. All rights reserved., cknowledgments This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (IþDþI) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Design of the PET–MR system for head imaging of the DREAM Project

  • González Martínez, Antonio Javier
  • Conde, P.
  • Hernández Hernández, Liczandro
  • Moliner Martínez, Laura
  • Orero Palomares, Abel
  • Peiró Cloquell, Antonio
  • Rodríguez-Alvarez, M.J.
  • Ros García, Ana
  • Sánchez Martínez, Filomeno
  • Soriano Asensi, Antonio
  • Vidal San Sebastián, Luis Fernando
  • Herrero Bosch, Vicente|||0000-0003-0860-2789
  • Monzó Ferrer, José María|||0000-0001-6554-3231
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
In this paper we describe the overall design of a PET–MR system for head imaging within the framework of the DREAM Project as well as the first detector module tests. The PET system design consists of 4 rings of 16 detector modules each and it is expected to be integrated in a head dedicated radio frequency coil of an MR scanner. The PET modules are based on monolithic LYSO crystals coupled by means of optical devices to an array of 256 Silicon Photomultipliers. These types of crystals allow to preserve the scintillation light distribution and, thus, to recover the exact photon impact position with the proper characterization of such a distribution. Every module contains 4 Application Specific Integrated Circuits (ASICs) which return detailed information of several light statistical momenta. The preliminary tests carried out on this design and controlled by means of ASICs have shown promising results towards the suitability of hybrid PET–MR systems., This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I + D + I) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Monolithic crystals for PET devices: optical coupling optimization

  • González Martínez, Antonio Javier
  • Peiró, A.
  • Conde, P.
  • Hernández Hernández, Liczandro
  • Moliner Martínez, Laura
  • Orero Palomares, Abel
  • Rodríguez-Álvarez, M.J.
  • Sánchez Martínez, Filomeno
  • Soriano Asensi, Antonio
  • Vidal San Sebastián, Luis Fernando
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
[EN] In this work we present a method to efficiently collect scintillation light when using monolithic scintillator crystals. The acceptance angle of the scintillation light has been reduced by means of optical devices reducing the border effect which typically affects continuous crystals. We have applied this procedure on gamma detectors for PET systems using both position sensitive PMTs and arrays of SiPMs. In the case of using SiPMs, this approach also helps to reduce the photosensor active area. We evaluated the method using PMTs with a variety of different crystals with thicknesses ranging from 10 to 24 mm. We found that our design allows the use of crystal blocks with a thickness of up to 18 mm without degrading the spatial resolution caused by edge effects and without a significant detriment to the energy resolution. These results were compared with simulated data. The first results of monolithic LYSO crystals coupled to an array of 256 SiPMs by means of individual optical light guides are also presented., This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), the Spanish Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica (I+D +I) under Grant no. FIS2010-21216-CO2-01 and the Valencian Local Government under Grant PROMETEO 2008/114.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET

  • Moliner Martínez, Laura
  • González Martínez, Antonio Javier
  • Rodríguez-Álvarez, M.J.|||0000-0001-8333-8792
  • F Sánchez
  • Vidal San Sebastian, Luis Fernando|||0000-0001-8852-8560
  • Benlloch Baviera, Jose María|||0000-0001-6073-1436
  • Correcher, Carlos
  • Conde Castellanos, Pablo Eloy
  • Hernández Hernández, Liczandro
  • Orero Palomares, Abel
  • Soriano Asensi, Antonio
In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality. © 2012 Elsevier B.V. All rights reserved., This work was supported by the Centre for Industrial Technological Development co-funded by FEDER through the Technology Fund (DREAM Project, IDI-20110718), by the Spanish Plan Nacional de Investigacion Cientifica, Desarrollo e Innovacion Tecnologica (I+D+I) under Grant. No. FIS2010-21216-CO2-01TEO 2008/114.