Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A refined model on flow and oxygen consumption in the human cornea depending on the oxygen tension at the interface cornea_post lens tear film during contact lens wear

  • Compañ Moreno, Vicente|||0000-0001-8233-7472
  • Espinos Gutierrez, Francisco Juan|||0000-0001-5901-646X
  • Aguilella-Arzo, Marcel
  • del Castillo, Roxana M.
  • del Castillo, Luis Felipe
[EN] The study of oxygen consumption rate under¿ in vivo¿ human cornea during contact lens wear has been technically a challenge and several attempts have been made in the last 20 years to model the physiology of the human cornea during contact lens wear. Unfortunately, some of these models, based on a constant corneal oxygen consumption rate, produce areas on the cornea where the oxygen tension is negative, which has no physical sense. In order to avoid such inconsistency, different researchers have developed alternative models of oxygen consumption, which predict the likely oxygen metrics available at the interface cornea/post lens tear film by determination of oxygen flux, oxygen consumption, and oxygen tension through the different layers (endothelium, stroma, and epithelium). Although oxygen deficiency produces corneal edema, corneal swelling, hypoxia, acidosis, and other abnormalities, the estimation of the oxygen distribution below the impact of a contact lens wear is interesting to know which lens transmissibility was adequate to maintain the cornea and avoid epithelial and stromal anoxia. The estimation of minimum transmissibility for a lens for extended wear applications will be very useful for both clinicians and manufacturers. The aim of this work is to present a complete discussion based on Monod kinetics model that permits give an estimation of oxygen partial pressure distribution, the profile distribution of corneal flux and oxygen consumption rate, and finally the estimation of the relaxation mechanism of the cornea depending on the oxygen tension at the interface cornea/post lens tear film. Relaxation time in this context can quantify the capability of the corneal tissue to adapt to increasing concentrations of oxygen. It is proposed this parameter as a biological meaningful indicator of the interaction between contact lens polymers and living tissues such as the corneal cellular layer., This work was supported by the Government of Spain (project no. PID2019-108434GB-100 AEI/FEDER,UE), and Universitat Jaume I (project no. UJI-B2018-53). This research was funded by DGTIC-UNAM, with access to the Miztli-UNAM supercomputer, with the project LANCADUNAM-DGTIC-055. This work was supported by UNAM-PAPIIT projects IG 100618, IG 114818, IN114318, IN120120.The authors want to thank Alberto López, Cain González, Alejandro Pompa, and Alan Ortega for technical help.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Modification of polyetherimide membranes with ZIFs fillers for CO2 separation

  • Vega, J.
  • Andrio, A.
  • Lemus, A.A.
  • Díaz, J.A.I.
  • del Castillo, L.F.
  • Gavara, Rafael
  • Compañ Moreno, Vicente|||0000-0001-8233-7472
[EN] Flat hybrid membranes composed of polyetherimide (PEI) as matrix and zeolitic imidazolate frameworks (ZIFs) as fillers at concentrations of 10 and 20 wt% were prepared. Apparent permeability coefficient and apparent diffusivity coefficient of gases (CO2 and N-2) for these hybrid membranes (PZIFs) were determined by the "timelag" method. The experimental conditions used were from 25 degrees C to 55 degrees C with pressures of 2, 3 and 5 bar. The PZIFs with fillers of ZIF-8 (PZ-Zn) and ZIF-67 (PZ-Co) showed apparent selectivities (alpha(pa(CO2)/pa(N2))) of 39.6 and 27.5, respectively, higher than the alpha(pa(CO2)/pa(N2)) of the reference membrane PEI, while the membrane with filler of ZIF-Mix (PZ-Zn/Co) showed the lowest alpha(pa(CO2)()/pa(N2)) selectivity of 10.3 in the membrane series (under conditions of 25 degrees C and 2 bar). It is proposed that the selectivity of the membrane series can be attributed to two critical factors: the particle size/distribution ratio in the polymer base and sorption of CO2 at local sites of the bimetallic mixture. On the other hand, gas permeation studies (O-2, CO2 and CH4, and CO2/CH(4 )and CO2/C2H4 mixtures), were carried out in the series of PZIFs membranes. Permeability data were obtained by an isostatic method based on a permeation cell connected in series to a gas chromatograph where the rate of permeated gases was analyzed until a stationary state was reached. The complementary characterization techniques were: scanning electron microscopy, thermogravimetric analysis, and powder X-ray diffraction, which support the existence of the amorphous/crystalline phases of the PZIFs., This research has been supported by the ENE/2015-69203-R project, granted by the Ministerio de Economia y Competitividad (MINECO), Spain; Also authors are grateful to UNAM-DGAPA-PAPIIT projects IG-100185, and IG-114818. This study was partially supported by the CONACyT (Mexico) projects 2013-05-231461 and CB -2014-01-235840.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

High proton conductivity at low and moderate temperature in a simple family of Prussian blue analogs, divalent transition metal hexacyanocobaltates (III)

  • Vega-Moreno, J.
  • Lemus-Santana, A.A.
  • Reguera, E.
  • Andrio, A.
  • Compañ Moreno, Vicente|||0000-0001-8233-7472
[EN] Proton conductivity behavior was studied in a family of hexacyanocobaltates with divalent transition metals (II), HCCMs. The HCCMs, with molecular formula M3[Co(CN)6]2-xH2O (where M = Ni, Co, Fe, Mn and Cd), had cubic crystal structures and similar cell parameters. The number of water molecules per formula unit (x) present in each HCCMs was determined from thermogravimetric analysis data. Differences in conductivity values were evaluated by running dielectric impedance experiments. The values of the permittivity and conductivity real and imaginary parts were obtained for each material. The actual conductivity part was analyzed as a temperature and frequency function. Mobilities, diffusivities, and ion charge densities were derived from the electrode polarization model that appropriately fits the loss tangent curves. The measurement conditions for all the samples were relative humidity of 99% and temperature ranging from 25 to 105 °C. The conductivity values obtained for the HCCMs varied from 10-4 to 10-2 S cm-1. At low temperatures, proton conductivity values for the nickel hexacyanocobaltate (HCCNi) stood out (from 10 -3 and 10-2 S cm-1, at 25 and 45°C, respectively), followed by Fe, Cd, Co and Mn. In addition to the results stated above, activation energies were determined using the Arrhenius model, where the obtained values were below 21.1 kJ mol-1. The proton transport activation energies suggest that the transport through the HCCM porous framework was achieved by the Grotthuss mechanism. The diffusivity in the porous framework increased with temperature for all the samples except for HCCNi, following the trend DHCCFe > DHCCMn> DHCCCo> DHCCCd. The variability observed between the samples could be related to the ion-binding energies (Eb). These results indicate that hexacyanocobaltates can be useful as mixed matrix membrane (MMM) fillers, providing excellent conductivity and diffusivity when the medium contains a sufficient amount of ionic components depending on the involved transition metal., This research has been supported by the ENE/2015-69203-R project, granted by the Ministerio de Economía y Competitividad (MINECO), Spain, also authors are grateful to UNAM-DGAPA-PAPIIT projects IG-100185, and IG-114818. This study was partially supported by the CONACyT (Mexico) projects 2013-05-231461 and CB-2014-01-235840. The authors appreciate the access to the experimental facility of the National Laboratory for Energy Conversion and Storage (CONACyT) to carry out the experimental study. The authors thank S. Vega from Mexican Institute of Petroleum (IMP) for reviewing and improving the English language of this work.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Dual Purpose Measurements with Displacement Sensors

  • Andrio, Andreu
  • del Castillo, Luis Felipe
  • Compañ Moreno, Vicente|||0000-0001-8233-7472
[EN] In this paper we show a laboratory experience describing the possibility to build a sensor using a coil to measure small thicknesses of materials with the possibility of measuring temperature simultaneously, with the same built sensor. Its operation is based on the following facts: An electric current (a.c), flows through a coil and a magnetic field appears producing self-induction characterized by an electromotive force induced in the coil, when a conductive piece is situated in front of the coil. That permits us to obtain information about the distance between the coil and the conductive piece. When this separation thickness is changing, the magnetic field around the coil changes, because the self-induction coefficient (L) is also changing. Using resistance and impedance measurements (voltage in our case) in the coil, an expression has been obtained for the determination of the thickness of a non-conductive sheet placed between a metallic plate and the coil. Calibration measurements of resistance with temperature have been obtained. The thermodynamic analysis is also presented showing the equation of state of the system between the voltage, temperature and the thickness of the non-conductive sample. The linear thermal-expansion coefficient of the sample is also determined., The authors gratefully acknowledge the support provided by the projects ENE/2015-69203-R from Ministerio de Economia y Competitividad (MINECO) (Spain), and DGAPA-PAPIIT IG100618 and DGAPA-PAPIIT IN-114818 (México) and also thanks to Raúl Reyes Ortíz and Alberto López Vivas for technical assistance.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Experimental and computational study of conductivity of multilayer graphene in polypropylene nanocomposites

  • del Castillo, Roxana M.
  • del Castillo, Luis F.
  • Calles, Alipio G.
  • Compañ Moreno, Vicente|||0000-0001-8233-7472
[EN] We study the electric conductivity of compounds formed by multilayer graphene in polypropylene. Our study makes a comparative analysis between the experimental and computational results. To obtain an experimental measurement of the electronic properties, we deposited multilayer graphene (MLG) nanoparticles over a polypropylene matrix. The deposition was made over several stages, in which we added to the polymer matrix different percentages of MLG nanoparticles using the melt compounding technique, and we studied the conductivities of the nanocomposites by means of electrochemical impedance spectroscopy (EIS). The second part consists of computational calculations, in which we studied the electronic properties of a graphene sheet under a polypropylene molecule with different slabs in the monomer. In both analyses, there is a strong percolation phenomenon with a percolation threshold of around 18% of the MLG nanoparticles. Before the percolation threshold, the charge carriers are constrained in the polypropylene molecule, making the system an insulating material and creating p-type doping. After the percolation threshold, the charge carriers are constrained in the graphene, making the system a conductor material and creating n-type doping with conductivity values of around 20 S m(-1). This phenomenon is a consequence of a change in the mechanism of charge transfer in the interface between the polypropylene molecule and graphene sheet. To describe the charge transfer mechanism, it is necessary to consider the quantum effect. The incorporation of the quantum effects and the percolation phenomenon make it possible for the theoretical conductivity to be close to the conductivity measured experimentally., This research has been supported by the ENE/2015-69203-R project, granted by the Ministerio de Economia y Competitividad (MINECO), Spain. Also, the authors are grateful to UNAM-DGAPA-PAPIIT projects IG 100618 y IG 114818, DGTIC-UNAM for access to the Miztli-UNAM supercomputer LANCAD-UNAM-DGTIC-055, and UNAM-DGAPA for the Postdoctoral grant for Roxana M. del Castillo.