Pasar al contenido principal

INNOVACIÓN Y DESARROLLO DE SISTEMAS PORTÁTILES DE DETECCIÓN BIOLÓGICA ÓPTICA DE ALTA EFICIENCIA - INNBIOD

IPT-2011-1429-010000

•
Nombre agencia financiadora Ministerio de Ciencia e Innovación
Acrónimo agencia financiadora MICINN
Programa Programa Nacional de Cooperación Público-Privada
Subprograma Subprograma INNPACTO
Convocatoria INNPACTO
Año convocatoria 2011
Plan Estatal 2008-2011 Plan Nacional de Investigación Científica, Desarrollo e Innovación Tecnológica
Unidad de gestión Subdirección General de Estrategias de Colaboracion Publico-Privada
Centro beneficiario GENETRIX, S.L.
Identificador persistente http://dx.doi.org/10.13039/501100004837

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Sub-micrometric reflectometry for localized label-free biosensing

  • Casquel, R.
  • Soler, J. A.
  • Holgado, M.
  • Lopez, A.
  • Lavin, A.
  • de Vicente, J.
  • Sanza, F. J.
  • Laguna, M. F.
  • Holgado Bolaños, Miguel
  • Bañuls Polo, María-José|||0000-0002-2422-7731
  • Puchades, Rosa|||0000-0002-9329-1593
In this work we present an optical technique for characterizing sub-micrometric areas based on reflectivity of the light as a function of angle of incidence for the two pure polarizations s and p, covering a range of angles of incidence from -71.80 degrees to 71.80 degrees with a resolution of 0.1 degrees. Circular areas with a diameter in the order of 600 nm can be characterized, and the spectra for the two polarizations can be obtained with a single measurement. For biosensing purposes, we have fabricated several Bio Photonic Sensing Cells (BICELLs) consisting of interferometers of 1240 nm of SU-8 polymer over silicon. An indirect immunoassay is performed over these BICELLs and compared experimentally with FT-VIS-NIR spectrometry and theoretical calculations. The Limit of Detection (LoD) achieved is comparable with standard high resolution spectrometry, but with the capability of analyzing sub-micrometric domains for immunoassays reactions onto a sensing surface. (C) 2015 Optical Society of America, This work has been partially funded under the projects under the projects PLATON (Ref: TEC2012-31145) and INNBIOD (Ref: IPT-2011-1429-01000) from the Ministerio de Economia y Competitividad (MINECO) of Spain. We acknowledge Nightingale-EOS and Stephen Morris for his contribution to the development of this optical tool.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Trends and challenges of refractometric nanoplasmonic biosensors, a review

  • Estévez, M. Carmen|||0000-0003-3694-7186
  • Otte Ortiz, Marinus Albertus
  • Sepúlveda, Borja|||0000-0002-1562-7602
  • Lechuga, Laura M.|||0000-0001-5187-5358
Motivated by potential benefits such as sensor miniaturization, multiplexing opportunities and higher sensitivities, refractometric nanoplasmonic biosensing has profiled itself in a short time span as an interesting alternative to conventional Surface Plasmon Resonance (SPR) biosensors. This latter conventional sensing concept has been subjected during the last decades to strong commercialization, thereby strongly leaning on well-developed thin-film surface chemistry protocols. Not surprisingly, the examples found in literature based on this sensing concept are generally characterized by extensive analytical studies of relevant clinical and diagnostic problems. In contrast, the more novel Localized Surface Plasmon Resonance (LSPR) alternative finds itself in a much earlier, and especially, more fundamental stage of development. Driven by new fabrication methodologies to create nanostructured substrates, published work typically focuses on the novelty of the presented material, its optical properties and its use - generally limited to a proof-of-concept - as a label-free biosensing scheme. Given the different stages of development both SPR and LSPR sensors find themselves in, it becomes apparent that providing a comparative analysis of both concepts is not a trivial task. Nevertheless, in this review we make an effort to provide an overview that illustrates the progress booked in both fields during the last five years. First, we discuss the most relevant advances in SPR biosensing, including interesting analytical applications, together with different strategies that assure improvements in performance, throughput and/or integration. Subsequently, the remaining part of this work focuses on the use of nanoplasmonic sensors for real label-free biosensing applications. First, we discuss the motivation that serves as a driving force behind this research topic, together with a brief summary that comprises the main fabrication methodologies used in this field. Next, the sensing performance of LSPR sensors is examined by analyzing different parameters that can be invoked in order to quantitatively assess their overall sensing performance. Two aspects are highlighted that turn out to be especially important when trying to maximize their sensing performance, being (1) the targeted functionalization of the electromagnetic hotspots of the nanostructures, and (2) overcoming inherent negative influence that stem from the presence of a high refractive index substrate that supports the nanostructures. Next, although few in numbers, an overview is given of the most exhaustive and diagnostically relevant LSPR sensing assays that have been recently reported in literature, followed by examples that exploit inherent LSPR characteristics in order to create highly integrated and high-throughput optical biosensors. Finally, we discuss a series of considerations that, in our opinion, should be addressed in order to bring the realization of a stand-alone LSPR biosensor with competitive levels of sensitivity, robustness and integration (when compared to a conventional SPR sensor) much closer to reality.