RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Assessment of Load Losses Caused by Harmonic Currents in Distribution Transformers Using the Transformer Loss Calculator Software

  • León-Martínez, Vicente|||0000-0002-1906-371X
  • Peñalvo-López, Elisa|||0000-0002-3143-822X
  • Montañana-Romeu, Joaquín|||0000-0003-3331-9205
  • Andrada-Monrós, Clara|||0000-0001-6344-6649
  • Molina-Cañamero, Laura
[EN] Transformer load losses cause various adverse effects, such as derating, a decreased lifetime, and greenhouse gas emissions. In this paper, the load losses caused by non-linear loads on distribution transformers are analyzed. For this study, the load loss expressions provided by the IEEE Standard C57.110 and ANSI/UL 1561-1562 were adapted to the usual case where the transformer currents differ in each phase. The novel load loss expressions adapted from the IEEE Standard C57.110 were applied using the software known as the ¿Transformer Loss Calculator¿ (TLC), implemented with LabVIEW. For the application of new load loss expressions, carbon dioxide (CO2) emissions were determined by multiplying the load losses by the emission factors of each country. The experimental results are based on the recordings made by a FLUKE 435 Series II analyzer on the second of two 1000 kVA transformers, feeding real residential distribution networks with very differently distorted loads. An analysis of these transformers shows that the annual energy losses and CO2 emissions obtained from the adapted load loss expressions could be more than 5% of those determined by the original IEEE and ANSI Standard expressions. Due to these percentage loss and emission differences, it is advisable to use the TLC software in transformer monitoring instruments, This research and APC was funded by GENERA Project (grant number 101077073) under the LIFE Programme of the EUROPEAN COMMISSION, and the Generalitat Valenciana within the ValREM Project (CIAICO/2022/007).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

An Indirect Procedure for Real-Time Monitoring the Neutral Conductor Deterioration in Three-Phase Distribution Networks

  • León-Martínez, Vicente|||0000-0002-1906-371X
  • Montañana-Romeu, Joaquín|||0000-0003-3331-9205
  • Peñalvo-López, Elisa|||0000-0002-3143-822X
  • Leon-Vinet, Amparo|||0000-0003-3773-8116
  • Cano-Martínez, Jorge
[EN] An indirect procedure for real-time monitoring the neutral conductor condition in threephase distribution networks, based on watching over the growth of a novel parameter (Dt), has been described in this paper. The parameter Dt has been defined as the relationship between the neutral-displacement power and Buchholz¿s apparent power measured at the fundamental frequency in the loads of the distribution networks for any condition of the neutral conductor and in its nominal conditions. The effectiveness of this procedure has been compared with other traditional indirect procedures, such as the surveillance of the RMS values of the line-to-neutral load voltages or their zero-sequence component. The practical application on a real distribution network reveals that the growth of the parameter Dt in the early stages of the breaking process of the neutral conductor follows a straight line whose equation is known for each length and section of that conductor, regardless of the loads and the voltage regulation of the transformer of the distribution network. This characteristic of the Dt parameter shows that the proposed procedure is suitable for monitoring neutral conductor deterioration and can be used for preventive maintenance of distribution networks., This research was funded by the European Commission under the LIFE Program, project LIFE21-CET-LOCAL-GENERA, grant number 101077073.