Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

Docta Complutense
Publicación Artículo científico (JournalArticle)

Role of particle type and concentration on characteristics of PEO coatings on AM50 magnesium alloy

  • Mohedano Sánchez, Marta
  • Arrabal Durán, Raúl
  • Mingo, Beatriz
  • Pardo Gutiérrez Del Cid, Ángel
  • Matykina, Endzhe
Composite ceramic coatings were formed on a magnesium alloy by AC plasma electrolytic oxidation using a phosphate-based electrolyte with α-Al2O3, monoclinic ZrO2 or CeO2 particles in suspension. Effects of particles concentration (2, 5 and 10 g/L) on the electrical response, composition/morphology and corrosion behaviour of the coatings were investigated. Findings revealed successful incorporation of particles, which were preferentially located in the outer coating layer. Due to high temperatures at the locations of microdischarges, zirconia particles underwent transformation from monoclinic to tetragonal structure. The majority of alumina and ceria particles remained unaffected, although some of the alumina particles possibly formed MgAl2O4 by reaction with the substrate. Porosity and thickness of the coatings tended to decrease with increasing particles concentration in the electrolyte. Coatings formed in the electrolytes containing CeO2 particles revealed the best long-term corrosion performance in 0.5 wt% NaCl solution.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

In vitro and in vivo evaluation of PEO-modified titanium for bone implant applications

  • Santos-Coquillat, A.
  • Martínez-Campos, Enrique
  • Mohedano, M.
  • Martínez-Corriá, R.
  • Ramos, Viviana
  • Arrabal, R.
  • Matykina, E.
This work investigated the capacity of plasma electrolytic oxidation coatings on titanium for biological regulation via controlled surface composition and morphology in order to improve osseointegration and implant fixation. PEO coatings with relatively high Ca/P ratios of ~2.0 and ~4.0 were designed, characterized and evaluated in vitro, focusing on murine osteoblast and osteoclast activities in order to reflect the equilibrium between bone synthesis and resorption. The coating with elevated anatase content and surface Ca/P ratio of ~2.0 disclosed a diminished osteoclast activity and adequate osteoblast differentiation, favoring an augmented bone matrix synthesis over resorption processes. The coating with Ca/P ratio of 4.0 and reduced pore population density enabled greater osteoclastic resorptive activity. Additionally, commercial mechanised dental implants were PEO-coated and placed in an adult pig for 8 weeks in order to test their biocompatibility and implant integration in a preliminary in vivo approach. Both coatings revealed positive behaviour, strong bone matrix deposition at the implant-tissue interface and higher mean BIC values than Ti CP, with no appreciable differences between the two coatings., The authors gratefully acknowledge funding received from the Ministerio de Economía y Competitividad (MINECO, MAT2013-42957- R, MAT2015-73355-JIN) and Regional Government of Madrid and EU Structural Funds (S2013/MIT-2862-CM, CT4/17/CT5/17/PEJD-2016/ IND-3095) E. Martinez-Campos is grateful to the support of Consejo Superior de Investigaciones Científicas and MINECO (MAT2013-42957- R). We thank Laura García (Noricum SL) for her help in histology treatment. In loving memory of our colleague Professor José Luis López Lacomb, Peer Reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

PEO coatings design for Mg-Ca alloy for cardiovascular stent and bone regeneration applications

  • Santos-Coquillat, A.
  • Esteban-Lucía, M.
  • Martínez-Campos, Enrique
  • Mohedano, M.
  • Arrabal, R.
  • Blawert, C.
  • Zheludkevich, M. L.
  • Matykina, E.
Four bioactive PEO (plasma electrolytic oxidation) coatings were generated on Mg0.8Ca alloy using a Ca/P-based electrolyte and adding Si or Fas necessary. Surface characteristics, chemical composition and ion liberation of the coatings were characterized using SEM/EDS (Scanning Electron Microscopy/Energy Dispersive X-ray spectroscopy), X-ray diffraction, optical profilometry and ICP-OES (inductively coupled plasma optical emission spectrometry). Direct biocompatibility studies were performed by seeding premyoblastic, endothelial and preosteoblastic cell lines over the coatings. Biocompatibility of the coatings was also evaluated with respect to murine endothelial, preosteoblastic, preosteoclastic and premyoblastic cell cultures using extracts obtained by the immersion degradation of the PEO-coated specimens. The coatings reduced the degradation of magnesium alloy and released Mg Ca, P, Si and F. Of all the studied compositions, the Si-containing PEO coating exhibited the optimal characteristics for use in all potential applications, including bone regeneration and cardiovascular applications. Coatings with high F content negatively influenced the endothelial cells. RAW 264.7, MC3T3 and co-culture differentiation studies using extracts of PEO coated Mg0.8Ca demonstrated improved osteoclastogenesis and osteoblastogenesis processes compared to bare alloy., This work was funded by Regional Government of Madrid and EU Structural Funds (S2013/MIT-2862-CM, P2018/NMT-4411). A. Santos- Coquillat is grateful to Youth Employment Initiative (YEI) of Regional Government of Madrid and EU Social Funds for financial support (PEJD-2016/IND-3095). M. Mohedano gratefully acknowledges the support of MINECO (MAT20I5-733 55-JIN)., Peer Reviewed