Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Evaluation of Hygrothermal Behaviour in Heritage Buildings through Sensors, CFD Modelling and IRT

  • Lerma Elvira, Carlos|||0000-0003-0436-3725
  • Garcia-Borràs, Júlia|||0000-0002-5470-0753
  • Mas Tomas, Maria De Los Angeles|||0000-0002-0097-0598
  • Torner-Feltrer, María Eugenia Milagro|||0000-0002-8296-0632
  • Vercher Sanchis, José|||0000-0001-9855-4201
  • Gil Benso, Enrique|||0000-0002-6617-640X
[EN] Architectural heritage, building materials and interior space are highly susceptible to temperature and relative humidity. A better knowledge of the hygrothermal dynamics inside buildings allows an adequate conservation of heritage. This work compares three non-destructive techniques (NDT), such as temperature and relative humidity sensors, finite element simulations (CFD) and thermographic pictures (IRT). The work has made it possible to carry out an assessment of the risk of condensation over a year and to identify affected periods and areas of the building. Sensors and IRT pictures provide real data to validate CFD simulations, facilitating a global analysis of the building. The results provided reflect a great concordance between the NDTs used.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Contribution of green roofs to energy savings in building renovations

  • Garcia-Borràs, Júlia|||0000-0002-5470-0753
  • Lerma Elvira, Carlos|||0000-0003-0436-3725
  • Mas Tomas, Maria De Los Angeles|||0000-0002-0097-0598
  • Vercher Sanchis, José|||0000-0001-9855-4201
  • Gil Benso, Enrique|||0000-0002-6617-640X
[EN] Reversing the consequences of climate change and achieving more resilient societies involves reducing CO2 emissions and energy consumption, especially in sectors as important as construction. Green roofs, due to their particularities, imply a series of benefits, among which energy saving stands out. This implies a reduction in the consumption of resources and in CO2 emissions, more evident in the case of the refurbishment of buildings. A comparison is proposed between the energy savings obtained by renovating only the roof and renovating the entire thermal envelope. This is done with three roof construction systems (including two green roofs) and in 6 Spanish cities that represent different climatic zones. The novelties provided by this research are based on the comparison of both renovation cases to obtain the influence of the roof with respect to the thermal improvement of the envelope. The energy savings obtained by renovating the roof are very similar in all cities, but after renovating the entire envelope, the savings increase as the climate gets colder.Determining themost influential variables in these savings, as well as the influence of the roof, allows choosing the most appropriate construction techniques to optimize the energy renovation of existing buildings., Fundingforopenaccesscharge:CRUE-UniversitatPolitècnicadeValència.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Irrigation proposals for improving the energy performance of green roofs in Mediterranean climate

  • Garcia-Borràs, Júlia|||0000-0002-5470-0753
  • Lerma Elvira, Carlos|||0000-0003-0436-3725
  • Mas Tomas, Maria De Los Angeles|||0000-0002-0097-0598
  • Vercher Sanchis, José|||0000-0001-9855-4201
  • Gil Benso, Enrique|||0000-0002-6617-640X
[EN] The evapotranspiration and cooling energy saving potential of green roofs is very great in the Mediterranean climate, due to high levels of solar radiation. However, the low rainfall limits these losses. The main goal of this research is to determine the energy savings achieved by increasing water availability by installing an irrigation system. It is proposed the computer simulation of a building renovated with three construction systems, according to real scaled models. Irrigation proposals are studied from two perspectives: (1) different irrigation rates for each green roof system and (2) different irrigation schedules. From the perspective of irrigation rates (1) it is observed that increased water input in extensive green roofs does not lead to increased evapotranspiration heat losses due to their limited water storage capacity. In extensive green roofs, increasing the water supply above the storage capacity implies increasing water outflow, but not heat losses. In relation to the irrigation schedules (2) the models with daily annual irrigation achieve very limited total savings, less than 1% compared to self-sustaining models. However, a daily irrigation system only during cooling periods achieves greater total savings, between 1% and 2% compared to self-sustaining models. The system is optimised by increasing energy savings and reducing water consumption. On green roofs in the Mediterranean climate, the increase in available water does not necessarily imply an increase in total energy savings. In these cases, it is essential to find a balance between limiting water consumption and reducing energy consumption., This research has been carried out within the project entitled "Hydrothermal study of green roofs. Analysis and design recommen-dations for greater efficiency" (PAID-01-19-10) , financed by public call by the Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Energy Efficiency Evaluation of Green Roofs as an Intervention Strategy in Residential Buildings in the Field of Spanish Climate

  • Garcia-Borràs, Júlia|||0000-0002-5470-0753
  • Lerma Elvira, Carlos|||0000-0003-0436-3725
  • Mas Tomas, Maria De Los Angeles|||0000-0002-0097-0598
  • Vercher Sanchis, José|||0000-0001-9855-4201
  • Gil Benso, Enrique|||0000-0002-6617-640X
[EN] The use of green roofs entails environmental, economic and social benefits as sustainable tools of architecture. They present proven benefits in the path towards carbon neutrality and the reduction of the consumption of energy resources, especially in the field of renovation and improvement of the thermal envelope. In Spain, the current climate crisis also implies a problem of water stress, so it is necessary to analyse in more detail the behaviour of self-sustaining green roofs in the different climatic and rainfall zones into which the territory is divided. Evapotranspiration is the main mechanism of heat dissipation in green roofs, but in this study, it is observed that in the case of self-sustaining roofs with limited water content, the greatest losses through evapotranspiration occur in climates with high temperatures and solar radiation, above cities with higher rainfall and colder climates. On the contrary, the greatest energy savings are obtained in this type of cold climate. Evapotranspiration in self-sustaining roofs is not the most determining factor for achieving energy savings. The design of the roof, the geometry and orientation of the building, as well as the cooling energy consumption, play a more determining role.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Separation layers and their influence on green roof water storage

  • Garcia-Borràs, Júlia|||0000-0002-5470-0753
  • Mas Tomas, Maria De Los Angeles|||0000-0002-0097-0598
  • Lerma Elvira, Carlos|||0000-0003-0436-3725
  • Vercher Sanchis, José|||0000-0001-9855-4201
  • Gil Benso, Enrique|||0000-0002-6617-640X
[EN] This study deals with how adding separation layers to flat roofs improves their design, construction, and sustainability. Better understanding and use of these layers leads to increased durability, lower maintenance, and simpler execution, with potential for material reuse and performance enhancement. Currently, the optional nature of separation layers hinders the overall sustainability of roofing systems, so this research seeks to guide building professionals in selecting suitable separation layers for flat roofs, considering factors like location, function, material composition, and mass. Particularly, it examines the impact of Water Storage layers on self-sustaining green roofs, aiming to enhance thermal performance, especially when water is scarce. Results indicate that installing these layers significantly increases water retention below the drainage layer, primarily in extensive green roofs, where values rise by 17%. Water Storage layers also extend water availability after rainfall, raising maximum daily humidity levels inside the roof by up to 10% on the third day post-rainfall compared to green roofs without such a layer., This work was supported by Universitat Politecnica de Valencia: [grant no PAID-01-19-10].