Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Design, establishment, analysis, and quality control of a high-precision reference frame in Cortes de Pallás (Spain)

  • García-Asenjo Villamayor, Luis|||0000-0001-6535-2216
  • Baselga Moreno, Sergio|||0000-0002-0492-4003
  • Martínez, Laura
  • Garrigues, Pascual
  • Luján, Raquel
[EN] A high-precision geodetic reference frame was required in Cortes de Pallas (Spain) to undertake a long-term deformation monitoring project. Involving distances up to 2000 m, the aimed accuracy was 1 mm and 3 mm for horizontal and vertical components, respectively. Such a high precision is necessary to detect possible displacements of selected points on a critical rocky area in a short period of time, i.e., 2 or 3 years, and also to provide ground control for the integration of precise 3D models periodically obtained by remote sensing techniques. Considering the historical geotechnical problems of the area, the possible influence of the hydroelectric power plant, and the peculiar orography of the zone, a proper analysis of the stability is crucial if the reference frame is to be used for rigorous over-time deformation monitoring. This paper describes the deformation monitoring of a 10-pillar geodetic network which was measured from 2018 to 2020 by using a sub-millimetric Mekometer ME5000 (0.2 mm + 0.2 ppm) along with a demanding observing methodology which includes a network of data loggers for temperature, humidity, and air pressure as well as proper calibration of sensors and instruments to prevent potential inconsistencies between the scale of the network and the unit of length of the International System (SI meter). The results demonstrated that the chosen methodology yielded the aimed accuracy. However, using such a high precision methodology entails the problem that small displacements of only 1 or 2 mm are significantly detected as deformations by conventional deformation analysis and then it arises the problem of finding a subset of stable points for a rigorous datum realization when all the points seem to displace. This general problem is analyzed in the particular case of Cortes de Pallas, where a balanced mix of deformation analysis and technical decisions was eventually adopted to define a precise and stable reference frame for rigorous over-time deformation monitoring., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

EDM-GNSS distance comparison at the EURO5000 calibration baseline: preliminary results

  • Wezka, Kinga
  • Próchniewicz, Dominik
  • Szpunar, Ryszard
  • Garrigues Talens, Pascual
  • Walo, Janusz
  • Luján, Raquel
  • García-Asenjo Villamayor, Luis|||0000-0001-6535-2216
  • Baselga Moreno, Sergio|||0000-0002-0492-4003
[EN] At the Pieniny Klippen Belt in Poland, the novel primary reference baseline EURO5000 is required as part of the European Research project GeoMetre to both validate refractivity-compensated EDM prototypes and investigate the metrological traceability of GNSS-based distances. Since the aimed uncertainty is 1 mm at 5 km (k = 2), the design, construction, and validation must be carefully prepared to fulfil the high standards of the GeoMetre field campaigns which are planned to be carried out in May 2022. This contribution describes the main features of the EURO5000 and presents the results of the preliminary validation which includes a first comparison between the results obtained by using precise currently available EDMs as well as GNSS techniques following the standard GNSS geodetic processing algorithms, on the one hand, and the improved GNSS-Based Distance Meter (GBDM+) approach developed at UPV, on the other hand. The preliminary validation presented in this contribution also permits (1) to detect potential problems in the use of the baseline such as potential geodynamic problems, atmospheric refraction or multipath limitations, (2) to produce a set of reliable results, and (3) to pave the way for the final field comparisons between the novel EDMs and the GBDM+ approach. The result of this metrological experiment may significantly contribute to overcome the limitations of current high-precision deformation monitoring applications that require their scale to be consistent with the SI-metre within 0.1 ppm in several km., The project 18SIB01 GeoMetre hasreceived funding from the EMPIR programme co-financedby the Participating States and from the European Union's Horizon 2020 research and innovation programme, funderID: 10.13039/100014132. Raquel Lujan acknowledges the funding from the Programa de Ayudas de Investigaciony Desarrollo (PAID-01-20) de la Universitat Politecnica deValencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

GBDM+: an improved methodology for a GNSS-based distance meter

  • Baselga Moreno, Sergio|||0000-0002-0492-4003
  • García-Asenjo Villamayor, Luis|||0000-0001-6535-2216
  • Garrigues Talens, Pascual
  • Luján, Raquel
[EN] The determination of distances consistent with the definition of the base unit of length in the International System of Units (SI), the SI meter, with uncertainties of less than 1 ppm up to 5 km in the open air is a current challenge that is being increasingly required for different applications, including the determination of local ties, calibration baselines, and high precision geodetic metrology in singular scientific and engineering projects. The required knowledge of the index of refraction of the propagating medium at the same level of 1 ppm is a hard limit to the use of precise electronic distance meters (EDMs), which has motivated the recent development of new two-color, refractivity compensated, EDM prototypes. As an alternative, the use of global navigation satellite systems (GNSS) could benefit from their high scale stability although the lack of appropriate estimation of the uncertainties in their sources of error and their unknown propagation into the final result during the data processing has prevented a rigorous uncertainty analysis and, therefore, the use of GNSS for absolute distance determination. Stemming from our initial methodology for a GNSS-based distance meter (GBDM) that was restricted to relatively horizontal baselines and distances up to 1 km only, we have improved the method so that its application range is extended to baselines of up to 5 km with a possibly significant height difference so that it provides the final baseline distance with the corresponding uncertainty derived from the uncertainties in the different error sources rigorously propagated through the equations by which the distance is finally determined. This improved methodology, named as GBDM+, constitutes a significant step forward in the application of GNSS to open air length metrology., The work leading to this paper was performed within the 18SIB01 GeoMetre project of the European Metrology Programme for Innovation and Research (EMPIR). This project has received funding from the EMPIR programme co-financed by the Participating States and from the European Union's Horizon 2020 research and innovation programme, funder ID: 10.13039/100014132. Raquel Lujan acknowledges the funding from the Programa de Ayudas de Investigacion y Desarrollo (PAID-01-20) de la Universitat Politecnica de Valencia.