Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Comparison of TOF and SL techniques for in-line measurement of food item volume using animal and vegetable tissues

  • Verdú-Amat, Samuel|||0000-0002-3910-4582
  • Ivorra, Eugenio|||0000-0001-6062-2061
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Girón Hernández, Lunier Joel
  • Barat Baviera, José Manuel|||0000-0001-8487-7114
  • Grau Meló, Raúl|||0000-0002-0540-5539
A comparison between the techniques Time of flight (TOF) and Structured Light (SL), for in-line process, was carried out to determine the volume of several food types with different compositions, structures and dimensions; 2 meat tissue (lean meat and pork fat) and 3 vegetable tissue (potato, apple and avocado). The volume obtained was compared with that determined by physical measurements, employing two statistical methods (a BlandeAltman study and partial least square analysis). Results showed that Structured Light (SL) was a better technique than Time of flight (TOF) for determining volume. The TOF technique was affected by factors which were more influential when the S/V ratio (surface of the sample exposed to the camera and sample volume) increased. SL was slightly affected by the composition of the sample. Fat content and the level of unsaturated fatty acids could be the reason for the reflection of the laser light on the surface of the samples thereby reducing the accuracy. Even so, the values of R2 and RMSE of cross-validation, for the worst fit, demonstrated the quality of the SL technique., We wish to thank the Polytechnic University of Valencia and Generalitat Valenciana for the financial support they provided through the PAID-06-08-3251 and GVPRE/2008/170 Projects, respectively.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Nondestructive assessment of freshness in packaged sliced chicken breasts using SW-NIR spectroscopy

  • Grau Meló, Raúl|||0000-0002-0540-5539
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Girón Hernández, Lunier Joel
  • Ivorra, Eugenio|||0000-0001-6062-2061
  • Fuentes López, Ana|||0000-0002-4144-2396
  • Barat Baviera, José Manuel|||0000-0001-8487-7114
A technique was developed to predict the freshness of packaged sliced chicken breast employing a nondestructive visible and short-wavelength near-infrared (SW-NIR) spectroscopy method. Spectra were recorded at 0, 7 and 14days using a camera, spectral filter (400-1000nm) and a halogen flood lighting system which were developed and calibrated for the purpose. Physicochemical, biochemical and microbiological properties such as moisture (x w), water activity (a w), pH, total volatile basic nitrogen (TVB-N), ATP breakdown compounds (K 1 values) and mesophilic bacteria (cfu g -1) were determined to predict freshness degradation. The spectra obtained were related to the storage time of the samples. The best wavelengths for modeling freshness were 413, 426, 449, 460, 473, 480, 499, 638, 942, 946, 967, 970 and 982nm. A linear correlation was found between the visible and SW-NIR spectroscopy and parameters such as microbiological counts, K 1 and T-VBN indexes. © 2010 Elsevier Ltd., We wish to thank the Polytechnic University of Valencia and Generalitat Valenciana for the financial support they provided through the PAID-06-08-3251 and GVPRE/2008/170 Projects, respectively.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Preliminary Study using Visible and SW-NIR Analysis for Evaluating the Loss of Freshness in Commercially Packaged Cooked Ham and Turkey Ham

  • Girón Hernández, Lunier Joel
  • Ivorra, Eugenio|||0000-0001-6062-2061
  • Sánchez Salmerón, Antonio José|||0000-0003-1896-5356
  • Fernández Segovia, Isabel|||0000-0002-7641-2680
  • Barat Baviera, José Manuel|||0000-0001-8487-7114
  • Grau Meló, Raúl|||0000-0002-0540-5539
[EN] A non-destructive Vis-NIR spectroscopy (400–1000 nm) method was developed to evaluate the loss of freshness of sliced and commercially packaged cooked ham and turkey ham without any sample manipulation. The spectra were recorded at 0, 30, 40, and 60 days using a camera, spectral filter (400–1000 nm) and a halogen floodlighting system which had been were developed and calibrated for the purpose. Physico-chemical, biochemical, and microbiological properties such as pH, total volatile basic nitrogen (TVB-N), ATP breakdown compounds, and colony-forming units were determined to predict the degradation of freshness. The image spectra obtained from visible and SW-NIR spectroscopy were related to the storage time of the samples. A PLS-DA model was developed independently for packaged or unpackaged samples using the second derivative of the spectra. Mean R2 prediction obtained for cooked ham was 0.915 and 0.949 for Turkey ham. The technique developed could be applied to monitoring the freshness of commercial packed cooked ham and turkey ham as a non-destructive technique. Further studies will be needed to check the spectra obtained from samples of different commercial brands in order to evaluate more precisely the efficiency of the method., Supported by the Polytechnic University of Valencia and Generalitat Valenciana, Projects No. PAID-06-08-3251 and GVPRE/2008/170.