Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Thermogalvanic corrosion and galvanic effects of copper and AISI 316L stainless steel pairs in heavy LiBr brines under hydrodynamic conditions

  • Sánchez Tovar, Rita
  • Montañés, Maria-Teresa|||0000-0002-2620-6926
  • Garcia-Anton, Jose|||0000-0002-0289-1324
Thermogalvanic corrosion of the copper/copper and AISI 316L/AISI 316L stainless steel pairs was studied in heavy lithium bromide brines under hydrodynamic conditions. The galvanic coupling effect between copper and stainless steel was also analysed. The cold electrode (25 °C) was the stainless steel for the galvanic pair, whereas copper temperature varied (25, 50 and 75 °C). A hydrodynamic circuit was designed to study thermogalvanic corrosion by means of the zero resistance ammeter technique. Hot cathodes take place in stainless steel pairs while cold cathodes are present in copper/copper and stainless steel/copper pairs; this agrees with the thermal temperature coefficient of the potential sign. Thermogalvanic corrosion increases corrosion rates, especially working with copper. Weight loss measurements show that there is a combined effect due to the thermogalvanic and the galvanic effects, The authors would like to express their gratitude to the MICINN (CTQ2009-07518), to the FPU Grant given to Rita Sanchez Tovar, to FEDER, to the Generalitat Valenciana for its help in the LSCM acquisition (MY08/ISIRM/S/100), to the Programa de Apoyo a la Investigacion y Desarrollo de la UPV (PAID-06-11-1864) and to Dr. Asuncion Jaime for her translation assistance.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Contribution of the flowing conditions to the galvanic corrosion of the copper/AISI 316L coupling in highly concentrated LiBr solutions

  • Sánchez Tovar, Rita
  • Montañés, Maria-Teresa|||0000-0002-2620-6926
  • Garcia-Anton, Jose|||0000-0002-0289-1324
The galvanic corrosion of copper/AISI 316L stainless steel couples has been studied under different temperatures and flowing conditions in heavy LiBr brines. The mixed potential theory, zero-resistance ammeter and weight loss measurements were performed. Temperature and Reynolds number increase galvanic corrosion rates of copper. Statistical analysis by means of multilevel factorial design reveals that temperature greatly affects galvanic current densities. Additionally, the mixed potential theory suggests that thermogalvanic corrosion may occur when the materials of the pair work at different temperatures. The most important increase of current densities due to thermogalvanic effects takes place at high Reynolds numbers with the highest difference of temperature between copper/AISI 316L pairs and the anode operating at 25 °C. The results obtained with the different techniques are in good agreement., The authors would like to express their gratitude to the FPU grant given to Rita Sanchez Tovar, MICINN (CTQ2009-07518), to FEDER, to the Programa de Apoyo a la Investigacion y Desarrollo de la UPV (PAID-06-11-1864), to the Generalitat Valenciana for its help in the LSCM acquisition (MY08/ISIRM/S/100) and to Dr. Asuncion Jaime for her translation assistance.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effects of microplasma arc AISI 316L welds on the corrosion behaviour of pipelines in LiBr cooling systems

  • Sánchez-Tovar, R.
  • Montañés, Maria-Teresa|||0000-0002-2620-6926
  • Garcia-Anton, Jose|||0000-0002-0289-1324
[EN] The effect of microplasma arc welding (MPAW) on the electrochemical and corrosion behaviour of AISI 316L stainless steel tubes has been studied. Scanning electrochemical measurements were performed in sodium chloride to evaluate the difference in the electrochemical activity of base (non-welded) and welded samples. Oxygen reduction rates increase in AISI 316L due to the heat treatment effect induced by welding, indicating a higher electrochemical activity in the welded samples. Additionally, the use of MPA weldments in lithium bromide (LiBr) absorption machines was also analysed at typical operating temperatures and Reynolds numbers. The welding process increases corrosion rates, hinders passivation and increases the susceptibility to pitting attack in LiBr. However, zero-resistance ammeter and localization index measurements show that the galvanic pair generated between the base and welded alloys is weak, both electrodes being in their passive state. Temperature greatly affects the corrosion process. (C) 2013 Elsevier Ltd. All rights reserved., The authors would like to express their gratitude to the FPU grant given to Rita Sanchez Tovar, MICINN (CTQ2009-07518), to FEDER, to the Programa de Apoyo a la Investigacion y Desarrollo de la UPV (PAID-06-11-1864), to the Generalitat Valenciana for its help in the SECM acquisition (PPC/2011/013) and to Dr. Asuncion Jaime for her translation assistance.