DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

New equation for specific retention volumes in capillary column gas chromatography

  • Lebrón-Aguilar, Rosa
  • Quintanilla-López, Jesús Eduardo
  • Tello, Ana María
  • Fernández-Torres, Alberto
  • García-Domínguez, José Antonio
11 pages, 4 figures, 7 tables, The evaluation of specific retention volumes in gas chromatography is subject to several sources of error. The use of wall-coated open-tubular columns should yield better values for specific retention volumes. However, on scaling down the flow-rate of the carrier gas, mass of stationary phase and column head pressure, new sources of error are introduced. A careful consideration of the possible sources of error is presented. It was found that, for the use of capillary columns, the classical equation describing the specific retention volume may be modified so that no flow-rates, column head and outlet pressures or mass of stationary phase in the column are necessary in order to obtain correct specific retention volumes. © 1995 Elsevier Science B.V. All rights reserved., This work was performed with the financial assistance of the Direcci6n General de Investigación Científica y Técnica of Spain, under Proyect PB91-0077, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Measuring specific retention volumes in capillary gas chromatography with improved accuracy and precision

  • Quintanilla-López, Jesús Eduardo
  • Lebrón-Aguilar, Rosa
  • Tello, Ana María
  • García-Domínguez, José Antonio
9 pages, 2 figures, 7 tables, The specific retention volume (V(g)), which has traditionally been determined in gas chromatography using long, heavily loaded packed columns, should produce better, more reliable values if capillary columns are used. However, the smaller dimensions of some of the parameters involved introduces additional sources of error which have been overcome with a recently proposed equation. A careful consideration of the sources of error involved has been carried out using both the traditional and the new equations. The conclusion drawn is that the new equation will produce reliable V(g) values with expected errors (1%) lower than those expected from packed columns (2%) using the traditional equation., This work was carried out with the financial assistance of the Dirección General de Investigación Cientifica y Técnica of Spain, under Projects PB91-0077 and PB94-0218. We are particularly grateful to Q. Dai, who provided data on the density of the stationary phase with carefully performed experiments., Peer reviewed