Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Tectomer-mediated optical nanosensors for tyramine determination

  • Domínguez, Mario
  • Oliver, Sofía
  • Garriga, Rosa
  • Muñoz, Edgar
  • Cebolla, Vicente L.
  • Marcos, Susana de
  • Galbán, Javier
The development of optical sensors for in situ testing has become of great interest in the rapid diagnostics industry. We report here the development of simple, low-cost optical nanosensors for the semi-quantitative detection or naked-eye detection of tyramine (a biogenic amine whose production is commonly associated with food spoilage) when coupled to Au(III)/tectomer films deposited on polylactic acid (PLA) supports. Tectomers are two-dimensional oligoglycine self-assemblies, whose terminal amino groups enable both the immobilization of Au(III) and its adhesion to PLA. Upon exposure to tyramine, a non-enzymatic redox reaction takes place in which Au(III) in the tectomer matrix is reduced by tyramine to gold nanoparticles, whose reddish-purple color depends on the tyramine concentration and can be identified by measuring the RGB coordinates (Red–Green–Blue coordinates) using a smartphone color recognition app. Moreover, a more accurate quantification of tyramine in the range from 0.048 to 10 μM could be performed by measuring the reflectance of the sensing layers and the absorbance of the characteristic 550 nm plasmon band of the gold nanoparticles. The relative standard deviation (RSD) of the method was 4.2% (n = 5) with a limit of detection (LOD) of 0.014 μM. A remarkable selectivity was achieved for tyramine detection in the presence of other biogenic amines, especially histamine. This methodology, based on the optical properties of Au(III)/tectomer hybrid coatings, is promising for its application in food quality control and smart food packaging., This work is part of the I+D+i project PID2019-105408GB-I00 supported by projects MCIN/AEI/10.13039/501100011033 and PDC2021-121224-100, and the funding to research groups of the DGA, Spain (E25_20R)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Solving color reproducibility between digital devices: A robust approach of smartphones color management for chemical (bio)sensors

  • Cebrián, Pablo
  • Pérez-Sienes, Leticia
  • Sanz Vicente, Isabel
  • López-Molinero, Ángel
  • Marcos, Susana de
  • Galbán, Javier
This article belongs to the Special Issue Smartphone-Based Sensors for Biomedical Applications., In the past twelve years, digital image colorimetry (DIC) on smartphones has acquired great importance as an alternative to the most common analytical techniques. This analysis method is based on fast, low-cost, and easily-accessible technology, which can provide quantitative information about an analyte through the color changes of a digital image. Despite the fact that DIC is very widespread, it is not exempt from a series of problems that are not fully resolved yet, such as variability of the measurements between smartphones, image format in which color information is stored, power distribution of the illuminant used for the measurements, among others. This article proposes a methodology for the standardization and correction of these problems using self-developed software, together with the use of a 3D printed light box. This methodology is applied to three different colorimetric analyses using different types and brands of smartphones, proving that comparable measurements between devices can be achieved. As color can be related to many target analytes, establishing this measurement methodology can lead to new control analysis applicable to diverse sectors such as alimentary, industrial, agrarian, or sanitary., This work is part of the I + D + i project PID2019-105408GB-I00 supported by MCIN/AEI/10.13039/501100011033; the project PDC2021-121224-I00 supported by MICIN/AEI/Next Generation EU, and the founding to research groups of the DGA-FEDER (E25_20R)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Portable colorimetric enzymatic disposable biosensor for histamine and simultaneous histamine/tyramine determination using a smartphone

  • Sanz Vicente, Isabel
  • Rivero, Irina
  • Marcuello, Lucía
  • Montano, María Pilar
  • Marcos, Susana de
  • Galbán, Javier
Tyramine oxidase (TAO), peroxidase (HRP), and Amplex Red (AR) have been immobilized on cellulose to obtain disposable biosensors for the determination of histamine. During the enzymatic reaction, AR is oxidized and a pink spot is obtained. Using a smartphone and measuring the G (green) color coordinate, histamine can be determined in the presence of other biogenic amines (putrescine and cadaverine) in concentrations ranging from 2·10−5 M to 5·10−4 M with a 7.5·10−6 M limit of detection (LoD). Despite tyramine interference, experimental conditions are provided which allow rapid and simple histamine and simultaneous histamine/tyramine (semi)quantitative determination in mixtures. Finally, tyramine and histamine were determined in a tuna extract with good results (compared to the reference HPLC–MS method). The methodology can also be applied in solution allowing histamine (and simultaneous histamine/tyramine) determination with a lower LoD (1.8·10−7 M) and a similar selectivity., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature., This work is part of the I + D + i project PID2019-105408GB-I00 supported by MCIN/AEI/10.13039/501100011033, the project PDC2021-121224-I00 supported by MICIN/AEI/Next Generation EU and the funding to research groups of the DGA (E25_20R)., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Solving Color Reproducibility between Digital Devices: A Robust Approach of Smartphones Color Management for Chemical (Bio)Sensors

  • Cebrián, Pablo
  • Pérez-Sienes, Leticia
  • Sanz-Vicente, Isabel
  • López-Molinero, Ángel
  • Marcos, Susana
  • Galbán, Javier
In the past twelve years, digital image colorimetry (DIC) on smartphones has acquired great importance as an alternative to the most common analytical techniques. This analysis method is based on fast, low-cost, and easily-accessible technology, which can provide quantitative information about an analyte through the color changes of a digital image. Despite the fact that DIC is very widespread, it is not exempt from a series of problems that are not fully resolved yet, such as variability of the measurements between smartphones, image format in which color information is stored, power distribution of the illuminant used for the measurements, among others. This article proposes a methodology for the standardization and correction of these problems using self-developed software, together with the use of a 3D printed light box. This methodology is applied to three different colorimetric analyses using different types and brands of smartphones, proving that comparable measurements between devices can be achieved. As color can be related to many target analytes, establishing this measurement methodology can lead to new control analysis applicable to diverse sectors such as alimentary, industrial, agrarian, or sanitary.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Portable colorimetric enzymatic disposable biosensor for histamine and simultaneous histamine/tyramine determination using a smartphone

  • Sanz-Vicente, Isabel
  • Rivero, Irina
  • Marcuello, Lucía
  • Montano, María Pilar
  • de Marcos, Susana
  • Galbán, Javier
Tyramine oxidase (TAO), peroxidase (HRP), and Amplex Red (AR) have been immobilized on cellulose to obtain disposable biosensors for the determination of histamine. During the enzymatic reaction, AR is oxidized and a pink spot is obtained. Using a smartphone and measuring the G (green) color coordinate, histamine can be determined in the presence of other biogenic amines (putrescine and cadaverine) in concentrations ranging from 2·10−5 M to 5·10−4 M with a 7.5·10−6 M limit of detection (LoD). Despite tyramine interference, experimental conditions are provided which allow rapid and simple histamine and simultaneous histamine/tyramine (semi)quantitative determination in mixtures. Finally, tyramine and histamine were determined in a tuna extract with good results (compared to the reference HPLC–MS method). The methodology can also be applied in solution allowing histamine (and simultaneous histamine/tyramine) determination with a lower LoD (1.8·10−7 M) and a similar selectivity.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Tectomer-mediated optical nanosensors for tyramine determination

  • Domínguez, Mario
  • Oliver, Sofía
  • Garriga, Rosa
  • Muñoz, Edgar
  • Cebolla, Vicente L.
  • de Marcos, Susana
  • Galbán, Javier
The development of optical sensors for in situ testing has become of great interest in the rapid diagnostics industry. We report here the development of simple, low-cost optical nanosensors for the semi-quantitative detection or naked-eye detection of tyramine (a biogenic amine whose production is commonly associated with food spoilage) when coupled to Au(III)/tectomer films deposited on polylactic acid (PLA) supports. Tectomers are two-dimensional oligoglycine self-assemblies, whose terminal amino groups enable both the immobilization of Au(III) and its adhesion to PLA. Upon exposure to tyramine, a non-enzymatic redox reaction takes place in which Au(III) in the tectomer matrix is reduced by tyramine to gold nanoparticles, whose reddish-purple color depends on the tyramine concentration and can be identified by measuring the RGB coordinates (Red–Green–Blue coordinates) using a smartphone color recognition app. Moreover, a more accurate quantification of tyramine in the range from 0.048 to 10 μM could be performed by measuring the reflectance of the sensing layers and the absorbance of the characteristic 550 nm plasmon band of the gold nanoparticles. The relative standard deviation (RSD) of the method was 4.2% (n = 5) with a limit of detection (LOD) of 0.014 μM. A remarkable selectivity was achieved for tyramine detection in the presence of other biogenic amines, especially histamine. This methodology, based on the optical properties of Au(III)/tectomer hybrid coatings, is promising for its application in food quality control and smart food packaging.