Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Validation of two immunoassays for oxytocin measurements in human saliva

  • Lopez Arjona, Marina|||0000-0003-3025-440X
  • Cerón, José Joaquín|||0000-0002-8654-1793
  • Mateo, Sandra V.
  • Contreras-Aguilar, M. D.|||0000-0003-2898-0410
  • Martínez Subiela, Silvia|||0000-0002-1524-1558
The objective of this research was to develop and validate two immunoassays for oxytocin measurement in human saliva, one using a monoclonal and the other a polyclonal antibody against oxytocin, whose affinity for oxytocin was tested by an antibody mapping epitope analysis. These assays were analytically validated and used to compare oxytocin concentrations with those obtained with a commercial kit before and after the extraction or reduction/alkylation (R/A) treatments to saliva samples. The assays were also used to evaluate changes in salivary oxytocin concentrations following a physical effort and an induced psychological stress, which have previously been described as situations that cause an increase in salivary oxytocin. Both assays showed to be precise and accurate in the validation studies, and the antibodies used showed a defined binding region in case of the monoclonal antibody, whereas the polyclonal antibody showed binding events through all the oxytocin sequence. Although the monoclonal and polyclonal assays showed a positive correlation, they give results in a different range of magnitude. Both assays showed significant increases in oxytocin concentrations when applied after the physical effort and the psychological stress. This study shows that a variability in the reported values of oxytocin can occur depending on the assay and indicates that the use of different types of antibodies can give a different range of values when measuring oxytocin in saliva.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Oxytocin measurements in saliva, an analytical perspective

  • Lopez Arjona, Marina|||0000-0003-3025-440X
  • Botía, María|||0000-0002-0390-2953
  • Martínez Subiela, Silvia|||0000-0002-1524-1558
  • Cerón, José Joaquín|||0000-0002-8654-1793
Oxytocin has traditionally been known for its physiological effects on muscle contraction associated with birth and lactation, but in the last years is widely used as a biomarker of "positive experiences" in psychology and behavior. Different types of samples have been used for oxytocin measurements with saliva samples having the particular advantage of an easy and non-stressful collection. However, the low concentration of oxytocin in saliva can represent a limitation for its use. For this reason, sensitive assays and even a previous sample treatment in some cases are required for saliva oxytocin quantification. In addition, the lack of standardized and generally agreed-upon approach to peripheral oxytocin measurement leads to large discrepancies between different laboratories, that use different sample treatment protocols and different assays. The main objectives of this review are to describe the current status of the use of saliva for oxytocin measurement, provide details of the different sample processing techniques that can be applied and inform about the analytical techniques and assays available in different animal species, and also in humans for comparative purposes. It is expected that this information can contribute to an increase in the knowledge about the measurements of oxytocin in saliva and to its wider use in the future.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Comparison of the Effect of Two Different Handling Conditions at Slaughter in Saliva Analytes in Pigs

  • Botía, María|||0000-0002-0390-2953
  • Escribano Tortosa, Damián|||0000-0001-9439-6779
  • Ortín-Bustillo, Alba
  • López-Martínez, María José|||0000-0003-4159-037X
  • Fuentes, Pablo
  • Jiménez-Caparrós, Francisco J.
  • Hernández-Gómez, Juan L.
  • Avellaneda, Antonio
  • Cerón, José Joaquín|||0000-0002-8654-1793
  • Rubio, Camila Peres|||0000-0002-9293-4147
  • Tvarijonaviciute, Asta|||0000-0002-5323-5001
  • Martínez Subiela, Silvia|||0000-0002-1524-1558
  • Lopez Arjona, Marina|||0000-0003-3025-440X
  • Tecles, Fernando|||0000-0002-7635-533X
In this report, different handling conditions at slaughterhouse were studied to assess changes in salivary biomarkers. For this purpose, finishing pigs were divided into two groups, one in which handling was improved to minimize stress (Group A, n = 24, transported and stabled at the slaughterhouse at low density without mixing with unfamiliar animals throughout the whole process) and another one in which animals had a more stressful handling process (Group B, n = 24, transported and stabled at high density with unfamiliar animals). Saliva samples were taken the day before transport to the slaughterhouse at 8:00 a.m. (B0) and 12:00 a.m. (B4), and the day of slaughter just after unloading animals at the slaughterhouse at approximately 8:00 a.m. (S0) and after 4 h of lairage at approximately 12:00 a.m. (S4). Group B showed significantly higher cortisol, total esterase activity, oxytocin, adenosine deaminase and haptoglobin levels than the Group A at both S0 and S4 sampling times, and higher levels of calprotectin and creatine kinase at S4 sampling time. This report indicates that differences in the way in which the pigs are handled at the slaughterhouse can lead to changes in salivary biomarkers and opens the possibility of the use of biomarker at slaughter to monitor handling conditions.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Different Types of Glucocorticoids to Evaluate Stress and Welfare in Animals and Humans, General Concepts and Examples of Combined Use

  • Botía, María|||0000-0002-0390-2953
  • Escribano Tortosa, Damián|||0000-0001-9439-6779
  • Martínez Subiela, Silvia|||0000-0002-1524-1558
  • Tvarijonaviciute, Asta|||0000-0002-5323-5001
  • Tecles, Fernando|||0000-0002-7635-533X
  • Lopez Arjona, Marina|||0000-0003-3025-440X
  • Cerón, José Joaquín|||0000-0002-8654-1793
The main glucocorticoids involved in the stress response are cortisol and cortisone in most mammals and corticosterone in birds and rodents. Therefore, these analytes are currently the biomarkers more frequently used to evaluate the physiological response to a stressful situation. In addition, "total glucocorticoids", which refers to the quantification of various glucocorticoids by immunoassays showing cross-reactivity with different types of glucocorticoids or related metabolites, can be measured. In this review, we describe the characteristics of the main glucocorticoids used to assess stress, as well as the main techniques and samples used for their quantification. In addition, we analyse the studies where at least two of the main glucocorticoids were measured in combination. Overall, this review points out the different behaviours of the main glucocorticoids, depending on the animal species and stressful stimuli, and shows the potential advantages that the measurement of at least two different glucocorticoid types can have for evaluating welfare.