DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Influence of the background in Compton camera images for proton therapy treatment monitoring

  • Borja-Lloret, Marina
  • Barrientos, Luis
  • Bernabéu, José
  • Lacasta Llácer, Carlos
  • Muñoz, Enrique
  • Ros García, Ana
  • Roser, J.
  • Viegas, R.
  • Llosá, Gabriela
Objective. Background events are one of the most relevant contributions to image degradation in Compton camera imaging for hadron therapy treatment monitoring. A study of the background and its contribution to image degradation is important to define future strategies to reduce the background in the system. Approach. In this simulation study, the percentage of different kinds of events and their contribution to the reconstructed image in a two-layer Compton camera have been evaluated. To this end, GATE v8.2 simulations of a proton beam impinging on a PMMA phantom have been carried out, for different proton beam energies and at different beam intensities. Main results. For a simulated Compton camera made of Lanthanum (III) Bromide monolithic crystals, coincidences caused by neutrons arriving from the phantom are the most common type of background produced by secondary radiations in the Compton camera, causing between 13% and 33% of the detected coincidences, depending on the beam energy. Results also show that random coincidences are a significant cause of image degradation at high beam intensities, and their influence in the reconstructed images is studied for values of the time coincidence windows from 500 ps to 100 ns. Significance. Results indicate the timing capabilities required to retrieve the fall-off position with good precision. Still, the noise observed in the image when no randoms are considered make us consider further background rejection methods.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Radiopharmaceutical imaging of phantoms and patients with MACACO III Compton camera

  • Roser, Jorge
  • Barrientos, Luis
  • Bello, Pilar
  • Borja-Lloret, Marina
  • Calatayud, José Manuel
  • Casaña, José Vicente
  • Hueso-González, F.
  • Pérez-Curbelo, J.
  • Prado, Stefan
  • Ros García, Ana
  • Senra, C.
  • Viegas, R.
  • Torres Espallardo, Irene
  • Llosá, Gabriela
[Background and purpose] The use of Compton cameras for imaging radioisotopes in nuclear medicine offers potential advantages over conventional gamma cameras in some aspects. In this work, we present the first results in this field with the Compton camera prototype MACACO III after a measurement campaign in La Fe Hospital (Valencia, Spain)., [Methods] Images of Derenzo-like phantoms filled with 18F-FDG and I-NaI have been obtained with MACACO III and, in the latter case, with gamma cameras available in the hospital. Subsequently, a metastatic lesion in a patient treated with 131I-NaI after thyroid gland resection was imaged., [Results] The 18F-FDG phantom images show the prototype capability of identifying up to diameter rods. The measurements with 131I-NaI-filled phantoms demonstrate the clear improvement of the spatial resolution attainable with MACACO III when compared with images obtained with the gamma cameras available in the hospital. Finally, the image of the patient metastatic lesion obtained with the Compton camera was found to be consistent with the gamma camera inspection image., [Conclusion] These encouraging results demonstrate MACACO III’s capability for radiopharmaceutical imaging and open a door for its application to nuclear medicine., This work was funded by the Spanish Ministerio de Ciencia e Innovación (PDC2021-121839-I00) and the University of Valencia-IIS La Fe through the VLC biomed programme (PI2020-16)., Peer reviewed