Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Design of subwavelength grating-based bimodal waveguide interferometric sensor in visible range for enhancing diagnostics sensitivity

  • Singh, Rukmani
  • Lechuga, Laura M.
  • García-Rupérez, Jaime|||0000-0002-2036-0084
[EN] The demand for point-of-care biosensors capable of rapid, accurate, and specific detection has grown significantly, particularly in the wake of the COVID-19 pandemic. Silicon photonics-based biosensors, based on evanescent wave sensing, have positioned as competitive candidates to meet these needs due to their high index contrast, compact size, high sensitivity and specificity, CMOS compatibility, and low cost. Among various configurations, the bimodal waveguide (BiMW) interferometer stands out for its high sensitivity and compact footprint. Meanwhile, subwavelength grating (SWG) waveguides offer enhanced sensitivity by providing a larger active sensing area compared to conventional waveguides. In this work, we propose integrating SWG waveguides with BiMW interferometers, using silicon nitride (Si3N4) as the guiding material in the visible wavelength range to improve sensing performance through enhanced sensitivity and compactness. Si3N4 offers advantages such as low scattering losses and chemical stability in biological environments, while operation in visible range increases compatibility with biological assays, making this approach novel. We present a comprehensive device design, optimization, and analysis of the SWG-based BiMW interferometer for refractive index sensing applications. Three-dimensional full vectorial simulations were conducted using the finite element method in COMSOL Multiphysics for the device design and optimizations. The proposed device demonstrates notable improvements in sensing performance, with an intrinsic bulk sensitivity of 0.1479 RIU/RIU, intrinsic surface sensitivity of 2.41 x 10(-4) RIU nm(-1), and a theoretical phase sensitivity of 1318 rad RIU-1 mm(-1), all achieved within a compact footprint., We acknowledge the financial support received for the TRYPLEX project (PDC2023-145891-I00), funded by MCIN/AEI/PERTE CHIP and the European Union NextGenerationEU, as well as from the PROMETEO Program (CIPROM/2022/14) from the Generalitat Valenciana. The ICN2 is supported by the Severo Ochoa Centres of Excellence program, grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033. The nanoB2A is a consolidated research group ('Grup de Recerca') of the Generalitat de Catalunya and are supported by the Departament de Recerca i Universitats de la Generalitat de Catalunya (No. 2021 SGR 00456).
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Design of subwavelength grating-based bimodal waveguide interferometric sensor in visible range for enhancing diagnostics sensitivity

  • Singh, Rukmani
  • García-Rupérez, Jaime
  • Lechuga, Laura M.
The demand for point-of-care biosensors capable of rapid, accurate, and specific detection has grown significantly, particularly in the wake of the COVID-19 pandemic. Silicon photonics-based biosensors, based on evanescent wave sensing, have positioned as competitive candidates to meet these needs due to their high index contrast, compact size, high sensitivity and specificity, CMOS compatibility, and low cost. Among various configurations, the bimodal waveguide (BiMW) interferometer stands out for its high sensitivity and compact footprint. Meanwhile, subwavelength grating (SWG) waveguides offer enhanced sensitivity by providing a larger active sensing area compared to conventional waveguides. In this work, we propose integrating SWG waveguides with BiMW interferometers, using silicon nitride (Si<inf>3</inf>N<inf>4</inf>) as the guiding material in the visible wavelength range to improve sensing performance through enhanced sensitivity and compactness. Si<inf>3</inf>N<inf>4</inf> offers advantages such as low scattering losses and chemical stability in biological environments, while operation in visible range increases compatibility with biological assays, making this approach novel. We present a comprehensive device design, optimization, and analysis of the SWG-based BiMW interferometer for refractive index sensing applications. Three-dimensional full vectorial simulations were conducted using the finite element method in COMSOL Multiphysics for the device design and optimizations. The proposed device demonstrates notable improvements in sensing performance, with an intrinsic bulk sensitivity of 0.1479 RIU/RIU, intrinsic surface sensitivity of 2.41 × 10<sup>−4</sup> RIU nm<sup>−1</sup>, and a theoretical phase sensitivity of 1318 rad RIU<sup>−1</sup> mm<sup>−1</sup>, all achieved within a compact footprint., We acknowledge the financial support received for the TRYPLEX project (PDC2023-145891-I00), funded by MCIN/AEI/PERTE CHIP and the European Union NextGenerationEU, as well as from the PROMETEO Program (CIPROM/2022/14) from the Generalitat Valenciana. The ICN2 is supported by the Severo Ochoa Centres of Excellence program, grant CEX2021-001214-S, funded by MCIN/AEI/10.13039.501100011033. The nanoB2A is a consolidated research group (‘Grup de Recerca’) of the Generalitat de Catalunya and are supported by the Departament de Recerca i Universitats de la Generalitat de Catalunya (No. 2021 SGR 00456)., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021-001214-S), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Silicon Photonic Biosensors in Clinical Diagnostics: Emerging Opportunities and Challenges

  • Ramirez-Priego, Patricia
  • Alonso-Fernández, Andrés
  • Soler, María
  • Lechuga, Laura M.
As health care systems worldwide seek to decentralize diagnostics and expand precision medicine, silicon photonic biosensors have become a compelling solution. Their development over the past decade, especially in the last 5 years, marks a significant convergence of photonics, nanotechnology, and biomedical engineering that aims to reshape the diagnostic landscape. This review presents a comprehensive analysis of advances in silicon photonic biosensors, focusing on key configurations including microring resonators, photonic crystals, interferometers, and other emerging transduction mechanisms. We discuss the integration of advanced surface functionalization strategies for efficient and robust bioreceptor immobilization, which is critical for reliable biomedical applications. We emphasize the translation of these devices into clinical settings, primarily in infectious diseases and cancer diagnostics. Finally, we address current limitations, such as fabrication complexity, microfluidic integration, and data interpretation, and outline future directions to enhance scalability and clinical adoption in personalized medicine and decentralized health care., We acknowledge financial support received for the TYPLEX Project (grant PDC2023-145891-I00), funded by the Spanish for Ministry of Science, Innovation and Universities/Spanish State Research Agency (MCIU/AEI/10.13039/501100011033) and the European Union NextGenerationEU/Recovery, Transformation and Resilience Plan (PRTR). M.S. acknowledges economic support from the Ramón y Cajal Fellowship (RYC2020-029015-I), funded by the AEI/MCIN and the European Union NextGenerationEU/PRTR. The Catalan Institute of Nanoscience and Nanotechnology (ICN2) is funded by the CERCA program/Generalitat de Catalunya and is supported by the Severo Ochoa Centres of Excellence program (grant CEX2021‐001214-S), funded by MCIU/AEI/10.13039.501100011033., With funding from the Spanish government through the "Severo Ochoa Centre of Excelence" accreditation (CEX2021‐001214-S), Peer reviewed