Pasar al contenido principal

CONTROL DE ACCIONAMIENTOS POLIFASICOS TOLERANTES A FALTAS Y DE CONVERTIDORES PARA CONEXION A RED O PARA FUNCIONAMIENTO AISLADO

PID2019-105612RB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE VIGO

Resultados relacionados

Resultados totales (Incluyendo duplicados): 21
Encontrada(s) 1 página(s)

Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

A finite-control-set linear current controller with fast transient response and low switching frequency for grid-tied inverters

  • Pérez Estévez, Diego
  • Doval Gandoy, Jesús
This article presents a linear current controller for a grid-tied inverter with an L or LCL filter that uses a finite-control-set (FCS) operation. Thanks to the FCS operation, the proposed controller provides a very fast transient response, similar to an FCS model-predictive controller (MPC), while needing a low switching frequency and a low computational load. Contrarily to MPC solutions, the proposal uses a linear control structure. Such a linear structure offers a straightforward implementation and stability assessment compared to an MPC, which usually requires complex optimization algorithms and Lyapunov functions that are a field of study in its own right. The proposal does not generate any switching or low-order harmonics. By design, the switching noise is evenly spread at all frequencies instead of it being concentrated at some harmonic frequencies, as in the case of pulsewidth-modulator-based controllers. This reduces the risk of exciting resonances in the utility grid and facilitates the operation of multiple inverters in parallel. In particular, the proposal is shown to achieve compliance with stringent grid harmonic codes using an L filter in a multimegawatt application, where previous proposals required an LCL filter with the same total inductance, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

AC-voltage controller for grid-forming converters

  • Ríos Castro, Diego
  • Pérez Estévez, Diego
  • Doval Gandoy, Jesús
This article presents a voltage controller designed to operate grid-forming (GFM) converters under different grid impedance scenarios demonstrating good performance in conjunction with external power-synchronization loops (PSLs), e.g., droop control. GFM converters are required to have fast, accurate and stable voltage–frequency response, self-synchronization, power balance, grid supporting and fault ride-through (FRT) capabilities; either they are connected to the grid or to other generators. State-of-the-art voltage controllers are mainly focused on achieving either good voltage tracking and disturbance rejection or wide stability range and robustness. This proposal fulfils both tendencies as, first, it shows fast dynamic response, accurate voltage tracking, and total cancellation of output current disturbances at both positive-and negative-sequences of fundamental frequency because the controller presents zero-output impedance. Second, the controller shows a good sensitivity function and a wide stability range, which permit its operation in grid-connected and stand-alone mode. Finally, the proposed controller exhibits a good performance combined with a PSL under a wide range of grid impedance scenarios, showing seamless transition between grid-connected and stand-alone mode and vice versa, demonstrating also FRT capabilities preserving GFM operation under symmetrical and asymmetrical grid-fault events, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Recent advances in model predictive and sliding mode current control techniques of multiphase induction machines

  • Rodas, Jorge
  • González Prieto, Ignacio
  • Kali , Yassine
  • Saad, Maarouf
  • Doval Gandoy, Jesús
Multiphase machines have attracted the attention of the research and industrial communities due to their advantages, namely better power distribution and fault-tolerant capabilities without extra hardware. However, the multiphase machine requires high-performance control strategies to take advantage of these features. From this perspective, the field-oriented control with the inner current control loop that uses using an explicit modulation stage has been considered the benchmark solution thanks to the reduced harmonic distortion obtained with this regulation strategy. Nevertheless, nonlinear controllers, thanks to their inherent nature, allow exploiting the extra multiphase capabilities in a simplified manner. Consequently, this paper aims to concentrate and discuss the latest developments on nonlinear current control of two of the most popular multiphase electric drive configurations, five-phase and six-phase. Then, this paper covers mainly finite-control-set model predictive control and their variations. Moreover, sliding-mode control is also explained. Finally, this paper includes experimental assessments of the most recent nonlinear current control techniques considering steady-state and transient conditions, stability and performance analysis., Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

A comprehensive survey on fault tolerance in multiphase AC drives, part 1: general overview considering multiple fault types

  • Gómez Yepes, Alejandro
  • López Sánchez, Óscar
  • González Prieto, Ignacio
  • Durán, Mario J.
  • Doval Gandoy, Jesús
Multiphase drives offer enhanced fault-tolerant capabilities compared with conventional three-phase ones. Their phase redundancy makes them able to continue running in the event of faults (e.g., open/short-circuits) in certain phases. Moreover, their greater number of degrees of freedom permits improving diagnosis and performance, not only under faults affecting individual phases, but also under those affecting the machine/drive as a whole. That is the case of failures in the dc link, resolver/encoder, control unit, cooling system, etc. Accordingly, multiphase drives are becoming remarkable contenders for applications where high reliability is required, such as electric vehicles and standalone/off-shore generation. Actually, the literature on the subject has grown exponentially in recent years. Various review papers have been published, but none of them currently cover the state-of-the-art in a comprehensive and up-to-date fashion. This two-part paper presents an overview concerning fault tolerance in multiphase drives. Hundreds of citations are classified and critically discussed. Although the emphasis is put on fault tolerance, fault detection/diagnosis is also considered to some extent, because of its importance in fault-tolerant drives. The most important recent advances, emerging trends and open challenges are also identified. Part 1 provides a comprehensive survey considering numerous kinds of faults, whereas Part 2 is focused on phase/switch open-circuit failures., Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Ministerio de Ciencia, Innovación y Universidades | Ref. RYC2018-024407-I, Ministerio de Ciencia, Innovación y Universidades | Ref. PID2019-105612RB-I00, Junta de Andalucía | Ref. UMA20-FEDERJA-039
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Online control strategy for tolerating resistance asymmetry with minimum copper loss in the full torque range for symmetrical six-phase AC drives

  • Gómez Yepes, Alejandro
  • Abdel-Azim, Wessam E.
  • Shawier, Abdullah
  • Abdel-Majeed, Mahmoud Said
  • Che, Hang Seng
  • Abdel-Khalik, Ayman Samy
  • Ahmed, Shehab
  • Doval Gandoy, Jesús
Multiphase drives exhibit remarkable advantages (e.g., fault tolerance) over three-phase ones. Six-phase drives are particularly attractive, given their moderate complexity and suitability for off-the-shelf three-phase converters. Regarding the stator winding arrangement, the symmetrical one offers superior postfault capabilities in most scenarios. On the other hand, resistance asymmetry in the stator phases or connections may arise due to different causes. The conventional full-range minimum-loss strategy (FRMLS) generates stator-current references under open-phase (infinite resistance) faults so that torque ripple is prevented while minimizing the losses for each torque ( d - q current) value and maximizing the torque range; however, this method is unsuitable for unequal resistances of finite value. This article proposes an FRMLS for setting the current references to reach these goals in symmetrical six-phase drives with any resistance asymmetry. The optimum references are found online depending on the resistances, without lookup tables. The phase currents are individually limited by an iterative algorithm, so that minimum stator copper loss (SCL) is achieved over the maximum admissible torque range. In this manner, unlike the conventional FRMLS, minimum SCL and maximum torque range are attained even for finite resistance imbalance. The currents in phases affected by high resistances are suitably reduced. Experimental results are provided, Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00, Ministry of Higher Education, Malaysia | Ref. Scheme FP090-2020, Science, Technology and Innovation Funding Authority | Ref. 37066
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Statistical tools to evaluate the performance of current control strategies of power converters and drives

  • Rivas Martinez, Gustavo I.
  • Rodas, Jorge
  • Doval Gandoy, Jesús
The proposal of new current control techniques for power converters and electric motor drives has been one of the main research topics in the fields of power converters and drives during the past years. Usually, when evaluating and comparing the performance of current controllers, various figures of merit (FMs) are used, e.g., the mean squared error or the absolute error between the reference and the measurement. Here, it is shown that such FMs have a random nature. Nevertheless, only one result is reported in many published articles, for each FMs. Also, it is not indicated whether or not more than one trial has been performed to obtain the FM. In that case, opposite conclusions can be reached when two current controllers are compared, depending on the chosen results. In this sense, the number, n , of experimental runs required to accurately compare any FM, is proposed in order to address this problem. Likewise, a statistical comparison procedure is introduced to evaluate the relative performance of two controllers using any FM. Also, based on the proposed statistical comparison methodology compared to other criteria, an exhaustive simulation analysis is presented comparing the accuracy of decision-making. Finally, a real data set application based on experimental results is used to illustrate the proposed procedure, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Assessment and exploitation of the minimum current harmonic distortion under overmodulation in five-phase induction motor drives

  • Medina Sánchez, Martín
  • Gómez Yepes, Alejandro
  • López Sánchez, Óscar
  • Doval Gandoy, Jesús
This paper compares the most prominent overmodulation (OVM) techniques for five-phase induction motor drives with respect to the minimum current distortion (MCD) achievable. To attain a benchmark of the latter, two MCD OVM approaches are devised. Contrarily to previous strategies aimed at voltage distortion reduction/minimization, these MCD methods are focused on minimizing the harmonic stator copper loss (HSCL), thus minimizing the current total harmonic distortion (THD). One of these MCD strategies minimizes the HSCL while injecting only x–y harmonics. The other MCD method exploits α–β harmonic injection to further decrease the HSCL and to cover the whole OVM region. Moreover, the dual-mode OVM, which is one of the three-phase methods with the lowest distortion, is extended here for five-phase drives. The findings provide insight into how close the OVM methods are to the benchmark imposed by the MCD strategies. Notably, these MCD techniques yield a significant reduction of current THD, HSCL and peak current, especially for machines with negligible thirdorder space harmonic. The average switching losses are also decreased. Indications for real-time implementation of the MCD solutions are also given, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00, Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Agencia Estatal de Investigación | Ref. RYC2018-024407-I
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Experimental stability study of modulated model predictive current controllers applied to six-phase induction motor drives

  • Ayala, Magno
  • Doval Gandoy, Jesús
  • Gonzalez, Osvaldo
  • Rodas, Jorge
  • Gregor, Raul
  • Rivera, Marco
Modulated model predictive current control techniques are considered an interesting option to control multiphase drives due to their control flexibility and fast dynamic response. However, a practical stability study of those techniques is still missing. This article presents an experimental stability study, to quantify the limits of stability, to modulated predictive current controllers applied to an asymmetrical six-phase induction machine. Experimental results are presented to verify the theoretical analysis results in terms of stability ranges regarding sampling frequency and rotor speed, CONACYT-Paraguay | Ref. POSG16-05, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Pareto optimal weighting factor design of Predictive Current Controller of a six-phase induction machine based on particle swarm optimization algorithm

  • Fretes, Hector
  • Rodas, Jorge
  • Doval Gandoy, Jesús
  • Gomez, Victor
  • Gomez, Nicolas
  • Novak, Mateja
  • Rodriguez, Jose
  • Dragicevic, Tomislav
Finite-set model predictive control (FS-MPC) as predictive current control (PCC) is considered an exciting option for the stator current control of multiphase machines due to their control flexibility and easy inclusion of constraints. The weighting factors (WFs) of PCC must be tuned for the variables of interest, such as the machine losses x−y currents, typically performed by trial-and-error procedure. Tuning methods based on artificial neural network (ANN) or the coefficient of variation were proposed for three-phase inverter and motor drive applications. However, the extension of this concept to the multiphase machine application is not straightforward, and only empirical procedures have been reported. In this context, this article proposes an optimal method to tune the WF of the PCC based on the multiobjective particle swarm optimization (MOPSO) algorithm. A Pareto dominance concept is used for the MOPSO to find the optimal WF values for the PCC, comparing parameters of root-mean-square error of the stator tracking currents. The proposed method offers a systematic approach to the WF selection, with an algorithm of easy implementation with direct control over the size of the search space and the speed of convergence. Simulation and experimental results in steady-state and transient conditions are provided to validate the proposed offline tuning procedure of the PCC of a six-phase induction machine. The improvements of RMSE can be more than 500% for x−y subspace, with minor effect in α−β subspace. Finally, the proposed method is extended to a more complex cost function, and the results are compared with an ANN approach, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00, Agencia Nacional de Investigación y Desarrollo, Chile | Ref. FB0008, Agencia Nacional de Investigación y Desarrollo, Chile | Ref. ACT192013, Agencia Nacional de Investigación y Desarrollo, Chile | Ref. 1210208
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Influence of the process parameters on the quality and efficiency of the resistance spot welding process of advanced high-strength complex-phase steels

  • Morales Sánchez, Gerardo
  • Collazo Fernandez, Antonio
  • Doval Gandoy, Jesús
In this study, the effects of electrical characteristics of an inverter combined with main welding parameters on the resistance spot weldability of advanced high strength steels (AHSS) CP1000 is investigated. The main welding parameters, current and time, were varied. The effects on the geometry and microstructure of the weld spot, the diameter of the weld pad, the hardness, the shear strength, and the efficiency of the process were studied, and the results were compared for two switching frequencies of the medium frequency converter. Furthermore, the weldability lobes were obtained as a function of the shear strength, for both frequencies. This work shows that the quality of the welding, in the established terms, is better when a lower frequency is used, even though the parameterization of the welding equipment can be easier for higher frequencies., Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00 / AEI / 10.13039 / 501100011033, Xunta de Galicia | Ref. ED431B 2020/03
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Study and active enhancement by converter reconfiguration of the performance in terms of stator copper loss, derating factor and converter rating of multiphase drives under two open legs with different stator winding connections

  • Gómez Yepes, Alejandro
  • Doval Gandoy, Jesús
Multiphase machines offer inherent tolerance to faults such as open converter legs (OCLs), which are especially frequent. Because of this reason, they are particularly attractive for applications where fault tolerance is important, such as offshore wind energy or aerospace, naval and military vehicles. It has been previously shown that, under an OCL, certain stator winding configurations (SWCs) different from star yield smaller stator copper loss (SCL) and larger maximum achievable torque (MAT) than star SWC for the same torque command and machine. This advantage comes just at the expense of a moderate increase in converter rating. However, only the case of single OCL was studied in general. The SCL, MAT and required converter rating for two OCLs are currently unknown for different combinations of phase number, faulted legs and SWCs. Actually, under two OCLs (unlike for one OCL) it may be possible to actively modify the order of the faulted/healthy legs to enhance the performance in these terms, but this possibility has not been studied so far in spite of its potential. This paper addresses the postfault performance of multiphase drives with two OCLs, for various SWCs. The MAT (derating factor), SCL and necessary converter rating are assessed in numerous possible scenarios. The most convenient alternatives are established. Most importantly, in view of the conclusions of this analysis, a novel method is proposed to improve substantially the MAT and SCL by actively altering the connections between the converter and machine terminals. Experimental results with six-phase and twelve-phase setups are provided., Xunta de Galicia | Ref. ED431F 2020/07, Ministerio de Ciencia, Innovación y Universidades | Ref. RYC2018-024407-I, Agencia Estatal de Investigacion | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Overmodulation method with adaptive x-y current limitation for five-phase induction motor drives

  • Gómez Yepes, Alejandro
  • Doval Gandoy, Jesús
Five-phase induction machines are attractive due to inherent benefits such as lower current rating than three-phase ones. On the other hand, ac motor drives often need to operate in the overmodulation (OVM) region, e.g., to increase the maximum speed or to work with reduced dc-link voltage. Most of the existing OVM strategies for five-phase drives are based on injecting low-order harmonics in the no-torque x y plane while avoiding low-order α - β harmonics (at least up to a modulation index of 1.2311p.u. ), so as to prevent the torque ripple associated with the α - β components. However, in practice the x - y impedance is very small, and hence, this approach can easily lead to overcurrent. This article proposes an OVM method for five-phase induction motors that adaptively modifies the injected components so that at each moment the addition of low-order x - y harmonics is favored over α - β ones but without surpassing the maximum current rms of the drive. In case the total stator copper loss (SCL) tends to exceed its rating during OVM in a given scenario, the proposed scheme automatically reduces the x - y injection to keep the SCL at its rated value. Experimental results verify the theory, Xunta de Galicia | Ref. ED431F 2020/07, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00, Agencia Estatal de Investigación | Ref. RYC2018-024407-I
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Discrimination between eccentricity and interturn faults using current or voltage-reference signature analysis in symmetrical six-phase induction machines

  • Gómez Yepes, Alejandro
  • Fonseca, Davide S. B.
  • Antunes, Hugo R. P.
  • López Sánchez, Óscar
  • Marques Cardoso, Antonio J.
  • Doval Gandoy, Jesús
Two common defects in induction machines (IMs) are eccentricity and interturn faults, which should be diagnosed to prevent performance degradation and further damage. A popular fault-detection approach is the current signature analysis (CSA), because of its simplicity and nonintrusiveness. Under closed-loop control, it is combined with analogous voltage-reference (VR) signature analysis (VRSA). However, by using these methods in three-phase IMs, it is difficult to discriminate between these faults, which cause similar symptoms. Multiphase machines provide remarkable advantages such as inherent tolerance to open-phase faults. Six-phase IMs are particularly attractive since they allow adopting three-phase converters. Among them, those with symmetrical spatial arrangement of the stator phases offer superior fault tolerance. Nonetheless, the distinction between eccentricity and interturn failures in these IMs has not been addressed so far. This article studies the discrimination between eccentricity and interturn faults in symmetrical six-phase (S6) IMs by CSA or VRSA. It is shown that, conversely to three-phase IMs and most other multiphase IMs, in S6 ones, these two types of failures can be easily distinguished: interturn faults considerably alter the currents or VRs in the so-called x - y plane, whereas eccentricity leads to current/voltage symptoms only in the α1 - β1 plane. Experimental results confirm the theory., Fondo Europeo de Desarrollo Regional, Fundação para a Ciência e a Tecnologia | Ref. PTDC/EEI-EEE/29494/2017, Fundação para a Ciência e a Tecnologia | Ref. UIDB/04131/2020, Fundação para a Ciência e a Tecnologia | Ref. UIDP/04131/2020, Fundação para a Ciência e a Tecnologia | Ref. UI/BD/153572/2022, Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. ED431B 2020/03, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Simple carrier-based PWM for prolonged high dc-link utilization for symmetrical and asymmetrical n-phase AC Drives

  • Gómez Yepes, Alejandro
  • Doval Gandoy, Jesús
Square voltage waveforms enable high dc-link utilization (DLU) in multiphase ac drives. Circulating-current filters were devised to attenuate the harmonics in no-torque low-impedance subspaces. Nonetheless, the square-wave harmonics that generate torque ripple are not reduced. Recently, it was proposed to combine circulating-current filters with a carrier-based pulsewidth modulation (PWM) method, which injects harmonics in no-torque subspaces (attenuated by the filter) of five-phase motors to achieve high DLU, without harmonics associated with torque ripple. The filter allows prolonged high-DLU operation without overheating. Compared with other PWM techniques capable of high-DLU operation (overmodulation), the one proposed for said filters is especially convenient because of its simplicity. However, it is unclear if this PWM method can be extended to machines of any phase number n and winding arrangement (symmetrical or asymmetrical); and if so, the resulting performance is also unknown. This article extends this simple carrier-based PWM strategy to n-phase drives, and evaluates its behavior in terms of DLU, distortion, and computational burden. Symmetrical and asymmetrical winding arrangements are considered. The improvement in DLU, compared with conventional PWM with zero-sequence injection, is considerable. Current distortion is negligible with a suitable filter. The simplicity over other high-DLU PWM techniques is remarkable. Experimental results are provided, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

A model predictive current controller with improved robustness against measurement noise and plant model variations

  • Pérez Estévez, Diego
  • Doval Gandoy, Jesús
This article improves the robustness of a finite control set (FCS)-model predictive controller (MPC) for grid-tied inverters and motor drives applications to plant parameter variations and noise, without reducing its bandwidth or affecting its excellent transient response to disturbances and reference commands. The proposed modification adds an observer to the MPC controller structure, which does not significantly increase the computational burden on the embedded controller. Traditionally, observers are employed to estimate unmeasured variables and cancel the effect of disturbances, but this article employs the observer to estimate a measured variable, the converter output current. This solution leverages the benefits of observers from linear controller theory in order to remove undesired components in the measured current and improve the robustness of the controller; hence it is a valuable solution for practicing power-electronic engineers and researchers in the field of grid-tied inverters and motor drives due to its simplicity compared to some advanced techniques often required in more complex MPC designs, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

General online current-harmonic generation for increased torque capability with minimum stator copper loss in fault-tolerant multiphase induction motor drives

  • Gómez Yepes, Alejandro
  • Shawier, Abdullah
  • Abdel-Azim, Wessam E.
  • Abdel-Khalik, Ayman Samy
  • Ahmed, Shehab
  • Doval Gandoy, Jesús
This article proposes a current-reference generation method, including current harmonic injection (CHI) for enhancing the torque capability of multiphase induction machines (IMs) with negligible space-harmonic effects, which is useful, e.g., during transient overload in electric vehicles. The admissible torque is increased because the harmonics reduce the phase-current peaks so that the instantaneous peak-current constraint of the drive, usually associated with the converter ratings, is respected. The harmonics are injected in the so-called x−y subspaces of the IM, which do not produce torque, so that no torque ripple is introduced. The optimum harmonics are found online for each load, making it possible to minimize the stator copper loss (SCL) per torque in the entire torque range, ensuring full-range minimum loss (FRML). The method is suitable for healthy operation or open-phase faults and for multiphase machines of any phase number and with either symmetrical or asymmetrical windings. Compared with FRML methods without CHI, higher torque is achieved. Although some techniques were available for increasing the torque capability by CHI, FRML was not attained, laborious off-line optimization was needed, or they were only suitable for specific drives or healthy conditions, unlike the proposal. Experimental results with a symmetrical six-phase IM are provided, Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Information Technology Industry Development Agency | Ref. ARP2020.R29.7, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00, Agencia Estatal de Investigación | Ref. RYC2018-024407-I
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

A comprehensive survey on fault tolerance in multiphase AC drives, part 2: phase and switch open-circuit faults

  • Gómez Yepes, Alejandro
  • González Prieto, Ignacio
  • López Sánchez, Óscar
  • Durán, Mario J.
  • Doval Gandoy, Jesús
Multiphase machines are very convenient for applications that require high reliability. In this two-part survey, the state of the art about fault tolerance in multiphase drives is reviewed. In Part 1, an overview including numerous fault types was presented, along with fundamental notions about multiphase drives. Here, in Part 2, the focus is placed on phase/switch open-circuit (OC) faults in particular, which have received the most attention in the literature. Phase OC failures involve OCs in stator phases or in converter-machine connections, and switch/diode OCs are frequently dealt with similarly or identically. Thanks to the phase redundancy of multiphase drives, their operation can be satisfactorily continued under a certain number of OCs. Nonetheless, the procedure to follow for this purpose is far from unique. For given OC fault conditions, numerous fault-tolerant possibilities can be found in the literature, each of them with different advantages and disadvantages. Moreover, a great variety of methods have also been devised to detect and diagnose phase/switch OC failures so that, as soon as possible, the most appropriate fault-tolerance measures are applied. Thus, given the broad literature about tolerance to phase/switch OC faults in multiphase drives, the survey presented here is expected to be of great interest for the research community and industry., Xunta de Galicia | Ref. ED431F 2020/07, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Ministerio de Ciencia, Innovación y Universidades | Ref. RYC2018-024407-I, Agencia Estatal de Investigación (AEI) | Ref. PID2019-105612RB-I00, Junta de Andalucía | Ref. UMA20-FEDERJA-039
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

DC-signal injection for stator-resistance estimation in symmetrical six-phase induction motors under open-phase fault

  • Gómez Yepes, Alejandro
  • Abdel-Majeed, Mahmoud Said
  • Che, Hang Seng
  • Abdel-Khalik, Ayman Samy
  • Ahmed, Shehab
  • Doval Gandoy, Jesús
Multiphase machines are often chosen due to their enhanced fault tolerance. Six-phase ones are especially convenient because they may be fed by off-the-shelf three-phase converters. In particular, those with symmetrical windings offer superior postfault capabilities. On the other hand, estimation of the stator resistance is important for purposes such as thermal monitoring and preserving control performance. Resistance estimation by dcsignal injection provides low sensitivity to parameter deviations compared with other techniques. It has previously been shown that the dc signal can be added in the non-torque-producing (xy) plane of a six-phase machine to avoid the torque disturbances that typically arise in three-phase machines. However, extending this method to the case of an open-phase fault (OPF) is not straightforward, because of the associated current restrictions. This paper addresses dc-signal injection in a symmetrical sixphase induction motor with an OPF. It is shown that, in contrast to healthy operation, the postfault dc injection should be carefully performed so that minimum copper loss, peak phase current and zero-sequence braking torque are achieved. A solution that attains optimum performance in all these aspects simultaneously is proposed. Adapted controller and resistance estimation are also presented. Experimental results confirm the theory, Ministry of Higher Education, Malaysia | Ref. Scheme FP090-2020, Science, Technology and Innovation Funding Authority | Ref. 37066, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Xunta de Galicia | Ref. ED431F 2020/07, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Grid current control for active-front-end electric propulsion systems in AC ship microgrids

  • Pérez Estévez, Diego
  • Doval Gandoy, Jesús
  • Crego Lourido, Alberto
This article proposes a finite control set (FCS) current controller for grid-tied converters, specifically tailored to meet the characteristics of ac ship microgrids in all-electric ships (AESs). Contrary to a pulsewidth modulator (PWM)- based design, which often employs an LCL filter, the proposal is able to meet applicable harmonic regulations using an L filter with the same total inductance as the LCL filter and the same switching frequency required by PWM-based solutions. Moreover, the proposed design provides a low sensitivity in a wide frequency range from dc to the switching frequency of the power converter. This low sensitivity permits to quickly attenuate low-order disturbances and it is particularly convenient in marine applications with a weak grid, where the frequent connection and disconnection of high power nonlinear loads can significantly affect the voltage waveform quality, Xunta de Galicia | Ref. GPC-ED431B 2020/03, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

On the advantages of symmetrical over asymmetrical multiphase AC drives with even phase number using direct controllers

  • Gonzalez Prieto, Angel
  • González Prieto, Ignacio
  • Gómez Yepes, Alejandro
  • Durán, Mario J.
  • Doval Gandoy, Jesús
Multiphase electric drives offer attractive advantages over conventional three-phase systems. Some of the benefits are shared by all multiphase configurations, but the performance can be highly affected by the specific location of the stator windings. While the asymmetrical configuration has been traditionally a popular choice, the symmetrical disposition in even-phase machines has a main advantage: it is possible to generate α – β voltages without any contribution in different x – y subspaces. This article explains and demonstrates this feature for the general case of distributed-winding symmetrical n -phase machines, with n being an even number. Fortunately, direct controllers can benefit from this characteristic by exclusively selecting voltage states with only α – β voltage production. To illustrate this capability, a finite-control-set model predictive control (FCS-MPC) using these special voltage states is also suggested in this work for symmetrical six-phase electric drives. This approach provides a greater simplicity and much less current distortion than in standard FCS-MPC for the asymmetrical configuration. Comparative experimental results confirm the minimal x – y injection of symmetrical configurations thanks to the proposed control actions (i.e., voltage states), Agencia Estatal de Investigación | Ref. RTI2018-096151-B-I00, Xunta de Galicia | Ref. ED431F 2020/07, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00
Investigo. Repositorio Institucional de la Universidade de Vigo
Publicación Artículo científico (JournalArticle)

Open-phase-tolerant online current references for maximum torque range and minimum loss with current and torque-ripple limits for n-phase nonsaliente PMSMs nonsinusoidal back EMF

  • Gómez Yepes, Alejandro
  • Abdel-Azim, Wessam E.
  • Shawier, Abdullah
  • Abdel-Khalik, Ayman Samy
  • Hamad, Mostafa S.
  • Ahmed, Shehab
  • Doval Gandoy, Jesús
Multiphase permanent-magnet synchronous machi- nes (PMSMs) with nonsinusoidal back-electromotive force (back EMF) offer high fault tolerance and torque density for electric vehicles. Most current-reference generation methods either minimize stator copper loss (SCL) or maximize achievable torque. Optimization of both goals is accomplished by full-torque-range minimum-loss (FRML) strategies, but so far just for sinusoidal back EMF. Thus, FRML for nonsinusoidal back EMF should be sought. Moreover, many methods are only suitable for healthy conditions or specific machines, harmonics, or open-phase-fault (OPF) scenarios. In addition, the torque range may be extended by permitting torque ripple or (transiently) greater rms current, but this approach is not general nor FRML yet. This article proposes online FRML current-reference generation for multiphase PMSMs with nonsinusoidal back EMF: nonsinusoidal-back-EMF FRML (NSBE-FRML). When the torque reference is feasible, minimum SCL is attained while maximizing the achievable torque (i.e., FRML). For higher torque references, the instantaneous torque deviation is minimized, and the torque reference is saturated in consecutive samples limiting the torque ripple to a prespecified threshold. Furthermore, the rms current is limited after transient overload by automatically decreasing the torque reference. The NSBE-FRML is suitable for any harmonics, healthy/OPF conditions, and multiphase PMSMs with negligible saliency ratio. Experiments are performed with a six-phase PMSM., Information Technology Industry Development Agency | Ref. ARP2020.R29.7, Xunta de Galicia | Ref. ED431F2020/07, Xunta de Galicia | Ref. ED431B2020/03, Agencia Estatal de Investigación | Ref. RYC2018-024407-I, Agencia Estatal de Investigación | Ref. PID2019-105612RB-I00