Changes in Biomarkers of Redox Status in Saliva of Pigs after an Experimental Sepsis Induction

  • López-Martínez, M.J.
  • Escribano Tortosa, Damián|||0000-0001-9439-6779
  • Ortín-Bustillo, A.
  • Franco-Martinez, Lorena|||0000-0003-3375-4274
  • González-Aróstegui, Luis Guillermo
  • Cerón, José Joaquín|||0000-0002-8654-1793
  • Rubio, Camila Peres|||0000-0002-9293-4147
Saliva from pigs is gaining attention as an easy sample to obtain, being a source of biomarkers that can provide information on animal health and welfare. This study aimed to evaluate the changes that can occur in salivary biomarkers of the redox status of pigs with an experimentally induced sepsis. For that, the cupric reducing antioxidant capacity (CUPRAC), ferric reducing ability of saliva (FRAS), Trolox equivalent antioxidant capacity (TEAC), advanced oxidation protein products (AOPP), ferrous oxidation-xylenol orange (FOX), peroxide activity (POX-Act), and reactive oxygen-derived compounds (d-ROMs) were measured in the saliva of pigs with experimentally induced sepsis by endotoxin lipopolysaccharide (LPS), non-septic inflammation induced by turpentine, and in healthy individuals before and after 3 h, 6 h, 24 h, and 48 h. AOPP, POX-Act, and d-ROMs in the sepsis group were higher than in the control from 3 h to 24 h after the inoculation. CUPRAC, FRAS, and TEAC were higher in sepsis than the control group at 24 h. These changes were of higher magnitude than those that occurred in the turpentine group. In conclusion, our findings reveal that sepsis produces changes in salivary biomarkers of redox status, which opens the possibility of using them as potential biomarkers in this species.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Measurement of Calprotectin (S100A8/A9) in the Saliva of Pigs, Validation Data of A Commercially Available Automated Assay and Changes in Sepsis, Inflammation, and Stress

  • López-Martínez, María José|||0000-0003-4159-037X
  • Martínez Subiela, Silvia|||0000-0002-1524-1558
  • Cerón, José Joaquín|||0000-0002-8654-1793
  • Ortín-Bustillo, Alba
  • Ramis, Guillermo
  • Lopez Arjona, Marina|||0000-0003-3025-440X
  • Martínez-Miró, Silvia|||0000-0002-1350-0886
  • García Manzanilla, Edgar|||0000-0002-2301-2560
  • Eckersall, Peter David|||0000-0001-5254-5502
  • Tecles, Fernando|||0000-0002-7635-533X
  • Escribano Tortosa, Damián|||0000-0001-9439-6779
  • Muñoz Prieto, Alberto|||0000-0001-6865-8712
Calprotectin (CALP, S100A8/A9) is a calcium and zinc-binding protein involved in inflammation that has a wide range of proinflammatory functions, such as cytokine production and regulation of leukocyte adhesion, migration, and phagocytosis. The objective of this study was to validate a commercially available assay for the measurement of CALP in the saliva of pigs and study the variations of this analyte due to sepsis, non-septic inflammation, and stress. The assay showed adequate precision and accuracy for the measurements of CALP in the saliva of pigs. In addition, this protein showed significant increases in the saliva of pigs with sepsis as well as after a stressful situation in our experimental conditions, being the increase in the stress of lower magnitude than in sepsis. Based on these results, CALP can be measured in the saliva of pigs and could be a potential biomarker of health and welfare in this species. Calprotectin (CALP, S100A8/A9), also named myeloid-related protein 8/14, is a dimer complex of S100A8 and S100A9 that belongs to the S-100 protein family. It is involved in inflammation and has a wide range of proinflammatory functions, such as cytokine production and regulation of leukocyte adhesion, migration, and phagocytosis. In humans, CALP traditionally can be measured in faeces, serum, and saliva as a biomarker of inflammation and sepsis. The objective of this study was to validate an automated assay for CALP measurements in the saliva of pigs, having the advantage of the use of a non-invasive sample that is easy to collect. The assay was precise and accurate. CALP in saliva measured by this assay showed significant changes depending on the hour of the day. It also showed significant increases in the saliva of pigs after the administration of lipopolysaccharide (LPS), and showed a rise, although with increases of lower magnitude, after a stressful stimulus. Further studies should be made to gain knowledge about the possible practical applications of the measurements of CALP in the saliva of pigs as a biomarker to evaluate the animals' health and welfare.