Pasar al contenido principal

PATIENT-TAILORED SOLUTIONS FOR BLOOD GLUCOSE CONTROL IN TYPE 1 DIABETES

PID2019-107722RB-C22

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2019
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT DE GIRONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 15
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Safety and performance of a hybrid closed-loop insulin delivery system with carbohydrate suggestion in adults with type 1 diabetes prone to hypoglycemia

  • Mesa, Álex
  • Beneyto, Aleix
  • Viaplana, Judith
  • Vehí, Josep
  • Conget, Ignacio
  • Giménez, Marga
  • Martín-SanJosé, Juan-Fernando|||0000-0002-3247-6156
  • Bondía Company, Jorge|||0000-0001-7286-3719
[EN] Aims: To evaluate the safety and performance of a hybrid closed-loop (HCL) system with automatic carbohydrate suggestion in adults with type 1 diabetes (T1D) prone to hypoglycemia.Methods: A 32-hour in-hospital pilot study, including a night period, 4 meals and 2 vigorous unannounced 45minute aerobic sessions, was conducted in 11 adults with T1D prone to hypoglycemia. The primary outcome was the percentage of time in range 70-180 mg/dL (TIR). Main secondary outcomes were time below range < 70 mg/dL (TBR < 70) and < 54 (TBR < 54). Data are presented as median (10th-90th percentile ranges).Results: The participants, 6 (54.5%) men, were 24 (22-48) years old, and had 22 (9-32) years of T1D duration. All of them regularly used an insulin pump and a continuous glucose monitoring system. The median TIR was 78.7% (75.6-91.2): 92.7% (68.2-100.0) during exercise and recovery period, 79.3% (34.9-100.0) during postprandial period, and 95.4% (66.4-100.0) during overnight period. The TBR < 70 and TBR < 54 were 0.0% (0.0-6.6) and 0.0% (0.0-1.2), respectively. A total of 4 (3-9) 15-g carbohydrate suggestions were administered per person. No severe acute complications occurred during the study.Conclusions: The HCL system with automatic carbohydrate suggestion performed well and was safe in this population during challenging conditions in a hospital setting., This work has been funded by Instituto de Salud Carlos III (ISCIII) through the project "PI19/01865" and co-funded by the European Union. It was also partially supported by the Spanish Ministry of Science and Innovation through grants PID2019-107722RB-C21 and PID2019-107722RB-C22, and in part by the Spanish Ministry of Universities and by the European Union through Next GenerationEU (Margarita Salas). Finally, it was also partially funded by Hospital Clinic de Barcelona under "Contractes Clinic de Recerca Emili Letang-Josep Font" 2021.The authors thank the research participants for their time, insight and dedication; as well as the staff at Hostal Lleida and at the Diabetes unit and hospital food service at Hospital Clinic de Barcelona for invaluable help.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Marks: A New Interval Tool for Uncertainty, Vagueness and Indiscernibility

  • Sainz, Miguel Ángel
  • Calm i Puig, Remei
  • Jorba, Lambert
  • Contreras, Ivan
  • Vehí, Josep
The system of marks created by Dr. Ernest Gardenyes and Dr. Lambert Jorba was first published as a doctoral thesis in 2003 and then as a chapter in the book Modal Interval Analysis in 2014. Marks are presented as a tool to deal with uncertainties in physical quantities from measurements or calculations. When working with iterative processes, the slow convergence or the high number of simulation steps means that measurement errors and successive calculation errors can lead to a lack of significance in the results. In the system of marks, the validity of any computation results is explicit in their calculation. Thus, the mark acts as a safeguard, warning of such situations. Despite the obvious contribution that marks can make in the simulation, identification, and control of dynamical systems, some improvements are necessary for their practical application. This paper aims to present these improvements. In particular, a new, more efficient characterization of the difference operator and a new implementation of the marks library is presented. Examples in dynamical systems simulation, fault detection and control are also included to exemplify the practical use of the marks, This work was partially supported by the Spanish Ministry of Science and Innovation through grant PID2019-107722RB-C22/AEI/10.13039/ 501100011033 and the Government of Catalonia under 2017SGR1551
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Generative deep learning for the development of a type 1 diabetes simulator

  • Mujahid, Omer
  • Contreras, Ivan
  • Beneyto Tantiña, Aleix
  • Vehí, Josep
Background: Type 1 diabetes (T1D) simulators, crucial for advancing diabetes treatments, often fall short of capturing the entire complexity of the glucose-insulin system due to the imprecise approximation of the physiological models. This study introduces a simulation approach employing a conditional deep generative model. The aim is to overcome the limitations of existing T1D simulators by synthesizing virtual patients that more accurately represent the entire glucose-insulin system physiology. Methods: Our methodology utilizes a sequence-to-sequence generative adversarial network to simulate virtual T1D patients causally. Causality is embedded in the model by introducing shifted input-output pairs during training, with a 90-min shift capturing the impact of input insulin and carbohydrates on blood glucose. To validate our approach, we train and evaluate the model using three distinct datasets, each consisting of 27, 12, and 10 T1D patients, respectively. In addition, we subject the trained model to further validation for closed-loop therapy, employing a state-of-the-art controller. Results: The generated patients display statistical similarity to real patients when evaluated on the time-in-range results for each of the standard blood glucose ranges in T1D management along with means and variability outcomes. When tested for causality, authentic causal links are identified between the insulin, carbohydrates, and blood glucose levels of the virtual patients. The trained generative model demonstrates behaviours that are closer to reality compared to conventional T1D simulators when subjected to closed-loop insulin therapy using a state-of-the-art controller. Conclusions: These results highlight our approach's capability to accurately capture physiological dynamics and establish genuine causal relationships, holding promise for enhancing the development and evaluation of therapies in diabetes, This work was partially supported by the Spanish Ministry of Universities, the European Union through Next GenerationEU (Margarita Salas), the Spanish Ministry of Science and Innovation through grant PID2019-107722RB-C22/AEI/10.13039/501100011033, PID2020-117171RA-I00 funded by MCIN/AEI/10.13039/501100011033 and the Government of Catalonia under 2017SGR1551 and 2020 FI_B 00965
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Intermittent closed-loop blood glucose control for people with type 1 diabetes on multiple daily injections

  • Estremera, Ernesto
  • Beneyto Tantiña, Aleix
  • Cabrera, Alvis
  • Contreras, Ivan
  • Vehí, Josep
Background and objectives: Recent advances in Automated Insulin Delivery systems have been shown to dramatically improve glycaemic control and reduce the risk of hypoglycemia in people with type 1 diabetes. However, they are complex systems that require specific training and are not affordable for most. Attempts to reduce the gap with closed-loop therapies using advanced dosing advisors have so far failed, mainly because they require too much human intervention. With the advent of smart insulin pens, one of the main constraints (having reliable bolus and meal information) disappears and new strategies can be employed. This is our starting hypothesis, which we have validated in a very demanding simulator. In this paper, we propose an intermittent closed-loop control system specifically intended for multiple daily injection therapy to bring the benefits of artificial pancreas to the application of multiple daily injections. Methods: The proposed control algorithm is based on model predictive control and integrates two patient-driven control actions. Correction insulin boluses are automatically computed and recommended to the patient to minimize the duration of hyperglycemia. Rescue carbohydrates are also triggered to avoid hypoglycemia episodes. The algorithm can adapt to different patient lifestyles with customizable triggering conditions, closing the gap between practicality and performance. The proposed algorithm is compared with conventional open-loop therapy, and its superiority is demonstrated through extensive in silico evaluations using realistic cohorts and scenarios. The evaluations were conducted in a cohort of 47 virtual patients. We also provide detailed explanations of the implementation, imposed constraints, triggering conditions, cost functions, and penalties for the algorithm. Results: The in-silico outcomes combining the proposed closed-loop strategy with slow-acting insulin analog injections at 09:00 h resulted in percentages of time in range (TIR) (70–180 mg/dL) of 69.5%, 70.6%, and 70.4% for glargine-100, glargine-300, and degludec-100, respectively, and injections at 20:00 h resulted in percentages of TIR of 70.5%, 70.3%, and 71.6%, respectively. In all the cases, the percentages of TIR were considerably higher than those obtained from the open-loop strategy, being only 50.7%, 53.9%, and 52.2% for daytime injection and 55.5%, 54.1%, and 56.9% for nighttime injection. Overall, the occurrence of hypoglycemia and hyperglycemia was notably reduced using our approach. Conclusions: Event-triggering model predictive control in the proposed algorithm is feasible and may meet clinical targets for people with type 1 diabetes, This work was partially supported by the Spanish Ministry of Science and Innovation under Grant number PID2019-107722RB-C22, by the Autonomous Government of Catalonia under Grant number 2017 SGR 1551, by the Spanish Ministry of Universities and European Union through the Next GenerationEU Plan (Margarita Salas), and by the program for researchers in training at the University of Girona (IFUdG2019), Open Access funding provided thanks to the CRUE-CSIC agreement with Elsevier
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

An ensemble machine learning approach for the detection of unannounced meals to enhance postprandial glucose control

  • Ibrahim, Muhammad
  • Beneyto Tantiña, Aleix
  • Contreras, Ivan
  • Vehí, Josep
Background: Hybrid automated insulin delivery systems enhance postprandial glucose control in type 1 diabetes, however, meal announcements are burdensome. To overcome this, we propose a machine learning-based automated meal detection approach; Methods: A heterogeneous ensemble method combining an artificial neural network, random forest, and logistic regression was employed. Trained and tested on data from two in-silico cohorts comprising 20 and 47 patients. It accounted for various meal sizes (moderate to high) and glucose appearance rates (slow and rapid absorbing). To produce an optimal prediction model, three ensemble configurations were used: logical AND, majority voting, and logical OR. In addition to the in-silico data, the proposed meal detector was also trained and tested using the OhioT1DM dataset. Finally, the meal detector is combined with a bolus insulin compensation scheme; Results: The ensemble majority voting obtained the best meal detector results for both the in-silico and OhioT1DM cohorts with a sensitivity of 77%, 94%, 61%, precision of 96%, 89%, 72%, F1-score of 85%, 91%, 66%, and with false positives per day values of 0.05, 0.19, 0.17, respectively. Automatic meal detection with insulin compensation has been performed in open-loop insulin therapy using the AND ensemble, chosen for its lower false positive rate. Time-in-range has significantly increased 10.48% and 16.03%, time above range was reduced by 5.16% and 11.85%, with a minimal time below range increase of 0.35% and 2.69% for both in-silico cohorts, respectively, compared to the results without a meal detector; Conclusion: To increase the overall accuracy and robustness of the predictions, this ensemble methodology aims to take advantage of each base model's strengths. All of the results point to the potential application of the proposed meal detector as a separate module for the detection of meals in automated insulin delivery systems to achieve improved glycemic control, This work was partially supported by the Spanish Ministry of Science and Innovation under Grant number PID2019-107722RB-C22 and PDC2021-121470-C22, by the Autonomous Government of Catalonia under Grant number 2021SGR01598 and by the program for researchers in training at the University of Girona IFUdG2021 (2021 FI_B00876), Open Access funding provided thanks to the CRUE-CSIC agreement with Elsevier
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Conditional Synthesis of Blood Glucose Profiles for T1D Patients Using Deep Generative Models

  • Mujahid, Omer
  • Contreras, Ivan
  • Beneyto Tantiña, Aleix
  • Conget, Ignacio
  • Giménez, Marga
  • Vehí, Josep
Mathematical modeling of the glucose–insulin system forms the core of simulators in the field of glucose metabolism. The complexity of human biological systems makes it a challenging task for the physiological models to encompass the entirety of such systems. Even though modern diabetes simulators perform a respectable task of simulating the glucose–insulin action, they are unable to estimate various phenomena affecting the glycemic profile of an individual such as glycemic disturbances and patient behavior. This research work presents a potential solution to this problem by proposing a method for the generation of blood glucose values conditioned on plasma insulin approximation of type 1 diabetes patients using a pixel-to-pixel generative adversarial network. Two type-1 diabetes cohorts comprising 29 and 6 patients, respectively, are used to train the generative model. This study shows that the generated blood glucose values are statistically similar to the real blood glucose values, mimicking the time-in-range results for each of the standard blood glucose ranges in type 1 diabetes management and obtaining similar means and variability outcomes. Furthermore, the causal relationship between the plasma insulin values and the generated blood glucose conforms to the same relationship observed in real patients. These results herald the aptness of deep generative models for the generation of virtual patients with diabetes, This work was partially supported by the Spanish Ministry of Universities, the European Union through Next GenerationEU (Margarita Salas), the Spanish Ministry of Science and Innovation through grant PID2019107722RBC22/AEI/10.13039/501100011033, PID2020-117171RA-I00 funded by MCIN/AEI/10.13039/501100011033 and the Government of Catalonia under 2017SGR1551 and 2020 FI_B 00965
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Combining Grammatical Evolution with Modal Interval Analysis: An Application to Solve Problems with Uncertainty

  • Contreras, Ivan
  • Calm i Puig, Remei
  • Sainz, Miguel Ángel
  • Herrero i Viñas, Pau
  • Vehí, Josep
Complex systems are usually affected by various sources of uncertainty, and it is essential to account for mechanisms that ensure the proper management of such disturbances. This paper introduces a novel approach to solve symbolic regression problems, which combines the potential of Grammatical Evolution to obtain solutions by describing the search space with context-free grammars, and the ability of Modal Interval Analysis (MIA) to handle quantified uncertainty. The presented methodology uses an MIA solver to evaluate the fitness function, which represents a novel method to manage uncertainty by means of interval-based prediction models. This paper first introduces the theory that establishes the basis of the proposed methodology, and follows with a description of the system architecture and implementation details. Then, we present an illustrative application example which consists of determining the outer and inner approximations of the mean velocity of the water current of a river stretch. Finally, the interpretation of the obtained results and the limitations of the proposed methodology are discussed, This work was partially supported by the Spanish Ministry of Science and Innovation through grant PID2019-107722RB-C22/AEI/10.13039/501100011033 and the Government of Catalonia under 2017SGR1551
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

A simulator with realistic and challenging scenarios for virtual T1D patients undergoing CSII and MDI therapy

  • Estremera, Ernesto
  • Cabrera, Alvis
  • Beneyto Tantiña, Aleix
  • Vehí, Josep
In silico simulations have become essential for the development of diabetes treatments. However, currently available simulators are not challenging enough and often suffer from limitations in insulin and meal absorption variability, which is unable to realistically reflect the dynamics of people with type 1 diabetes (T1D). Additionally, T1D simulators are mainly designed for the testing of continuous subcutaneous insulin infusion (CSII) therapies. In this work, a simulator is presented that includes a generated virtual patient (VP) cohort and both fast- and long-acting Glargine-100 U/ml (Gla-100), Glargine-300 U/ml (Gla-300), and Degludec-100 U/ml (Deg-100) insulin models. Therefore, in addition to CSII therapies, multiple daily injections (MDI) therapies can also be tested. The Hovorka model and its published parameter probability distributions were used to generate cohorts of VPs that represent a T1D population. Valid patients are filtered through restrictions that guarantee that they are physiologically acceptable. To obtain more realistic scenarios, basal insulin profile patterns from the literature have been used to identify variability in insulin sensitivity. A library of mixed meals identified from real data has also been included. This work presents and validates a methodology for the creation of realistic VP cohorts that include physiological variability and a simulator that includes challenging and realistic scenarios for in silico testing. A cohort of 47 VPs has been generated and in silico simulations of both CSII and MDI therapies were performed in open-loop. The simulation outcome metrics were contrasted with literature results, This work was partially supported by the Spanish Ministry of Science and Innovation through grant PID2019-107722RB-C22, in part by the Autonomous Government of Catalonia, Spain under Grant 2017 SGR 1551, and program for researchers in training at the University of Girona (IFUdG2019), Open Access funding provided thanks to the CRUE-CSIC agreement with Elsevier
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Machine Learning Techniques for Hypoglycemia Prediction: Trends and Challenges

  • Mujahid, Omer
  • Contreras, Ivan
  • Vehí, Josep
Background: the use of machine learning techniques for the purpose of anticipating hypoglycemia has increased considerably in the past few years. Hypoglycemia is the drop in blood glucose below critical levels in diabetic patients. This may cause loss of cognitive ability, seizures, and in extreme cases, death. In almost half of all the severe cases, hypoglycemia arrives unannounced and is essentially asymptomatic. The inability of a diabetic patient to anticipate and intervene the occurrence of a hypoglycemic event often results in crisis. Hence, the prediction of hypoglycemia is a vital step in improving the life quality of a diabetic patient. The objective of this paper is to review work performed in the domain of hypoglycemia prediction by using machine learning and also to explore the latest trends and challenges that the researchers face in this area; (2) Methods: literature obtained from PubMed and Google Scholar was reviewed. Manuscripts from the last five years were searched for this purpose. A total of 903 papers were initially selected of which 57 papers were eventually shortlisted for detailed review; (3) Results: a thorough dissection of the shortlisted manuscripts provided an interesting split between the works based on two categories: hypoglycemia prediction and hypoglycemia detection. The entire review was carried out keeping this categorical distinction in perspective while providing a thorough overview of the machine learning approaches used to anticipate hypoglycemia, the type of training data, and the prediction horizon, This work has been partially funded by the Spanish Government (PID2019-107722RB-C22) and the Government of Catalonia under 2017SGR1551 and 2020 FI_B 0096
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Generation of Individualized Synthetic Data for Augmentation of the Type 1 Diabetes Data Sets Using Deep Learning Models

  • Noguer, Josep
  • Contreras, Ivan
  • Mujahid, Omer
  • Beneyto Tantiña, Aleix
  • Vehí, Josep
In this paper, we present a methodology based on generative adversarial network architecture to generate synthetic data sets with the intention of augmenting continuous glucose monitor data from individual patients. We use these synthetic data with the aim of improving the overall performance of prediction models based on machine learning techniques. Experiments were performed on two cohorts of patients suffering from type 1 diabetes mellitus with significant differences in their clinical outcomes. In the first contribution, we have demonstrated that the chosen methodology is able to replicate the intrinsic characteristics of individual patients following the statistical distributions of the original data. Next, a second contribution demonstrates the potential of synthetic data to improve the performance of machine learning approaches by testing and comparing different prediction models for the problem of predicting nocturnal hypoglycemic events in type 1 diabetic patients. The results obtained for both generative and predictive models are quite encouraging and set a precedent in the use of generative techniques to train new machine learning models, This work was partially supported by the Spanish Ministry of Science and Innovation through grant [PID2019-107722RB-C22 /AEI/10.13039/501100011033]; [PID2020-117171RA-I00 funded by MCIN/AEI/10.13039/501100011033]; the Government of Catalonia under [2017SGR1551]
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Individualized Prediction of Blood Glucose Outcomes Using Compositional Data Analysis

  • Cabrera, Alvis
  • Estremera, Ernesto
  • Beneyto Tantiña, Aleix
  • Biagi, Lyvia
  • Contreras, Ivan
  • Martín Fernández, Josep Antoni
  • Vehí, Josep
This paper presents an individualized multiple linear regression model based on compositional data where we predict the mean and coefficient of variation of blood glucose in individuals with type 1 diabetes for the long-term (2 and 4 h). From these predictions, we estimate the minimum and maximum glucose values to provide future glycemic status. The proposed methodology has been validated using a dataset of 226 real adult patients with type 1 diabetes (Replace BG (NCT02258373)). The obtained results show a median balanced accuracy and sensitivity of over 90% and 80%, respectively. A information system has been implemented and validated to update patients on their glycemic status and associated risks for the next few hours, This research was partially supported by grants PID2019-107722RB-C22 and PID2019-107722RB-C12 funded by MCIN/AEI/10.13039/501100011033, the Autonomous Government of Catalonia under Grant 2017 SGR 1551, and by the program for researchers in training at the University of Girona (IFUdG2019), in part by Generation and Transfer of Compositional Data Analysis Knowledge (CODA-GENERA). Ministerio de Ciencia e Innovación, Agencia Estatal de Investigación (MCIN/AEI/10.13039/501100011033) y FEDER Una manera de hacer Europa (Ref: PID2021-123833OB-I00; 1 September 2022–31 August 2025). Research Group “Compositional and Spatial Analysis” (COSDA). Agència de Gestió d’Ajuts Universitaris i de Recerca (AGAUR), Generalitat de Catalunya (Ref: 2021SGR01197). (2022–2024)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Generation of Virtual Patient Populations That Represent Real Type 1 Diabetes Cohorts

  • Ahmad, Sayyar
  • Ramkissoon, Charrise Mary
  • Beneyto Tantiña, Aleix
  • Conget, Ignacio
  • Giménez, Marga
  • Vehí, Josep
Preclinical testing and validation of therapeutic strategies developed for patients with type 1 diabetes (T1D) require a cohort of virtual patients (VPs). However, current simulators provide a limited number of VPs, lack real-life scenarios, and inadequately represent intra- and inter-day variability in insulin sensitivity and blood glucose (BG) profile. The generation of a realistic scenario was achieved by using the meal patterns, insulin profiles (basal and bolus), and exercise sessions estimated as disturbances using clinical data from a cohort of 14 T1D patients using the Medtronic 640G insulin pump provided by the Hospital Clínic de Barcelona. The UVa/Padova’s cohort of adult patients was used for the generation of a new cohort of VPs. Insulin model parameters were optimized and adjusted in a day-by-day fashion to replicate the clinical data to create a cohort of 75 VPs. All primary and secondary outcomes reflecting the BG profile of a T1D patient were analyzed and compared to the clinical data. The mean BG 166.3 versus 162.2 mg/dL (p = 0.19), coefficient of variation 32% versus 33% (p = 0.54), and percent of time in range (70 to 180 mg/dL) 59.6% versus 66.8% (p = 0.35) were achieved. The proposed methodology for generating a cohort of VPs is capable of mimicking the BG metrics of a real cohort of T1D patients from the Hospital Clínic de Barcelona. It can adopt the inter-day variations in the BG profile, similar to the observed clinical data, and thus provide a benchmark for preclinical testing of control techniques and therapy strategies for T1D patients, This work was partially supported by the Spanish Ministry of Science and Innovation through grant PID2019-107722RB-C22/AEI/10.13039/501100011033 and the Government of Catalonia under 2017SGR1551 and 2019 FI_B 01200
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Validation of a Probabilistic Prediction Model for Patients with Type 1 Diabetes Using Compositional Data Analysis

  • Cabrera, Alvis
  • Biagi, Lyvia
  • Beneyto Tantiña, Aleix
  • Estremera, Ernesto
  • Contreras, Ivan
  • Giménez, Marga
  • Conget, Ignacio
  • Bondia, Jorge
  • Martín Fernández, Josep Antoni
  • Vehí, Josep
Glycemia assessment in people with type 1 diabetes (T1D) has focused on the time spent in different glucose ranges. As this time reflects the relative contributions to the finite duration of a day, it should be treated as compositional data (CoDa) that can be applied to T1D data. Previous works presented a tool for the individual categorization of days and proposed a probabilistic transition model between categories, although validation has hitherto not been presented. In this study, we consider data from eight real adult patients with T1D obtained from continuous glucose monitoring (CGM) sensors and introduce a methodology based on compositional methods to validate the previously presented probability transition model. We conducted 5-fold cross-validation, with both the training and validation data being CoDa vectors, which requires developing new performance metrics. We design new accuracy and precision measures based on statistical error calculations. The results show that the precision for the entire model is higher than 95% in all patients. The use of a probabilistic transition model can help doctors and patients in diabetes treatment management and decision-making. Although the proposed method was tested with CoDa applied to T1D data obtained from CGM, the newly developed accuracy and precision measures apply to any other data or validation based on CoDa, This research was partially supported by grants PID2019-107722RB-C22 and PID2019-107722RB-C21 funded by MCIN/AEI/10.13039/501100011033, in part by the Autonomous Government of Catalonia under Grant 2017 SGR 1551, in part by the Spanish Ministry of Universities,and by the European Union through Next GenerationEU (Margarita Salas), and by the program for researchers in training at the University of Girona (IFUdG2019)
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Active Labeling Correction of Mealtimes and the Appearance of Types of Carbohydrates in Type 1 Diabetes Information Records

  • Contreras, Ivan
  • Muñoz-Organero, Mario
  • Beneyto Tantiña, Aleix
  • Vehí, Josep
People with type 1 diabetes are required to adhere to their treatment rigorously to ensure maximum benefits. Diabetes tracking tools have played an important role in this regard. Type 1 diabetes monitoring has evolved and matured with the advent of blood glucose monitor sensors, insulin pens, and insulin pump automation. However, carbohydrate monitoring has seen little progress despite carbohydrates representing a major potential disruption. Relying on the modeling of carbohydrate intake using the rate of exogenous glucose appearance, we first present a methodology capable of identifying the type of carbohydrates ingested by classifying them into fast and non-fast carbohydrates. Second, we test the ability of the methodology to identify the correct synchrony between the actual mealtime and the time labeled as such in diabetes records. A deep neural network is trained with processed input data that consist of different values to estimate the parameters in a series of experiments in which, firstly, we vary the response of ingested carbohydrates for subsequent identification and, secondly, we shift the learned carbohydrate absorption curves in time to estimate when the meals were administered to virtual patients. This study validates that the identification of different carbohydrate classes in the meal records of people with type 1 diabetes could become a valuable source of information, as it demonstrates the potential to identify inaccuracies in the recorded meal records of these patients, suggesting the potential abilities of the next generation of type 1 diabetes management tools, This work was partially supported by grants PID2019-107722RB-C22, PID2020-117171RA-I00, and PID2019-105221RB-C44, which were funded by MCIN/AEI/ 10.13039/50110001103, by the European Union through Next GenerationEU, and by the Government of Catalonia under 2021SGR01598 and the Spanish Ministry of Universities
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

A hybrid automata approach for monitoring the patient in the loop in artificial pancreas systems

  • Beneyto Tantiña, Aleix
  • Puig, Vicenç
  • Bequette, B. Wayne
  • Vehí, Josep
The use of automated insulin delivery systems has become a reality for people with type 1 diabetes (T1D), with several hybrid systems already on the market. One of the particularities of this technology is that the patient is in the loop. People with T1D are the plant to control and also a plant operator, because they may have to provide information to the control loop. The most immediate information provided by patients that affects performance and safety are the announcement of meals and exercise. Therefore, to ensure safety and performance, the human factor impact needs to be addressed by designing fault monitoring strategies. In this paper, a monitoring system is developed to diagnose potential patient modes and faults. The monitoring system is based on the residual generation of a bank of observers. To that aim, a linear parameter varying (LPV) polytopic representation of the system is adopted and a bank of Kalman filters is designed using linear matrix inequalities (LMI). The system uncertainty is propagated using a zonotopic-set representation, which allows determining confidence bounds for each of the observer outputs and residuals. For the detection of modes, a hybrid automaton model is generated and diagnosis is performed by interpreting the events and transitions within the automaton. The developed system is tested in simulation, showing the potential benefits of using the proposed approach for artificial pancreas systems, This work was partially supported by the Spanish Ministry of Science and Innovation through grant PID2019-107722RB-C22, in part by the Autonomous Government of Catalonia under Grant 2017 SGR 1551, in part by the Ministerio de Educación, Cultura y Deporte under Grant FPU0244 2015, and in part EU through FEDER funds