Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Tailoring AA6063 for improving antibacterial properties

  • Medel-Plaza, Marina
  • Conde del Campo, Ana
  • Damborenea, Juan de
  • Aguilera-Correa, John-Jairo
  • Esteban, J.
  • Arenas, M. A.
Aluminium alloy 6063 was subjected to two different surface treatments: anodizing in sulphuric acid (SA) and the deposition of cerium conversion coatings (CeCC), in order to evaluate the antibacterial properties of the new surfaces. The microstructure and composition of the anodized samples and the cerium conversion coatings were characterized by scanning electron microscopy, energy dispersive spectrometry (SEM/EDS) and X-ray Photoemission Spectroscopy (XPS). Roughness and wettability were measured for all new surfaces. Bacterial adherence studies were carried out using Pseudomonas aeruginosa, with promising results for the anodized samples., This work was supported by Ministerio de Ciencia e Innovación (MICINN) PID2020-112878RB-100/AEI/10.13039/501100011033 - Development of Antimicrobial metallic surfaces-; the European Commission-Next Generation EU (Regulation EU2020/2024) through CSIC´s Global Health Platform and, PIE-CSIC 202060E194 and, CIBERINFEC-CIBER de Enfermedades Infecciosas (Centro de Investigaci´ on en Red de Enfermedades Infecciosas)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Effect of designed pore size on electrochemical, wear, and tribocorrosion behavior of additively manufactured Ti-6Al-4V lattice structures

  • Longhitano, Guilherme Arthur
  • García, Ignacio M.
  • Arenas, M. A.
  • Damborenea, Juan de
  • Maciel Filho, Rubens
  • Conde del Campo, Ana
The advent of additive manufacturing has been a disruptive technology in various fields, including medicine. One of the main causes of orthopedic implant failure is the mismatch between the implant material and the bone, causing bone resorption and aseptic loosening. In this regard, the use of additively manufactured lattice structures as orthopedic implant material has several advantages, such as producing a material with an adequate stiffness match with bone. Nevertheless, its behavior in service is not fully understood: the human body is a complex environment, and an orthopedic implant material is subjected to corrosion, wear, and tribocorrosion. In this work, Ti-6Al-4V solid and lattice structured samples were designed with pore sizes of 500, 700, and 900 µm and produced by PBF-EB. Microstructural and geometrical characterization was made on produced samples. The effect of pore sizes was analyzed under corrosion, wear, and tribocorrosion conditions, and compared with solid bulk samples. During corrosion tests, porous samples presented pitting attacks at high potentials, as the solid samples did not. The porous and solid samples presented similar behaviors under wear and tribocorrosion, with abrasive and adhesive wear as the predominant mechanism, and no statistical difference in the specific wear rates was found., This work was supported by the Sao Paulo Research Foundation (FAPESP) [grant numbers #2020/05612-8 and #2021/06516-5; the CTI’s Open Labs - Multiple Users and Shared Facilities from LAprint, CTI Renato Archer, research institution from MCTI; and partially funded by Ministerio de Ciencia e Innovacion (MICINN), PID2020-112878RB-100/ AEI/10.13039/501100011033 Development of Antimicrobial metallic surfaces., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Fluoride anodic films on stainless-steel fomites to reduce transmission infections

  • Conde del Campo, Ana
  • Voces, Daniel
  • Medel-Plaza, Marina
  • Perales, Celia
  • Ávila, Ana Isabel de
  • Aguilera-Correa, John-Jairo
  • Damborenea, Juan de
  • Esteban, Jaime
  • Domingo, E.
  • Arenas, M. A.
The growing concern arising from viruses with pandemic potential and multi-resistant bacteria responsible for hospital-acquired infections and outbreaks of food poisoning has led to an increased awareness of indirect contact transmission. This has resulted in a renewed interest to confer antimicrobial properties to commonly used metallic materials. The present work provides a full characterization of optimized fluoride anodic films grown in stainless steel 304L as well as their antimicrobial properties. Antibacterial tests show that the anodic film, composed mainly of chromium and iron fluorides, reduces the count and the percentage of the area covered by 50% and 87.7% for Pseudomonas aeruginosa and Stenotrophomonas maltophilia, respectively. Virologic tests show that the same treatment reduces the infectivity of the coronavirus HCoV-229E-GFP, in comparison with the non-anodized stainless steel 304L. IMPORTANCE The importance of environmental surfaces as a source of infection is a topic of particular interest today, as many microorganisms can survive on these surfaces and infect humans through direct contact. Modification of these surfaces by anodizing has been shown to be useful for some alloys of medical interest. This work evaluates the effect of anodizing on stainless steel, a metal widely used in a variety of applications. According to the study, the fluoride anodic layers reduce the colonization of the surfaces by both bacteria and viruses, thus reducing the risk of acquiring infections from these sources., This research has been funded by MCINN, PID2020-112878RB-100/AEI/10.13039/501100011033; the European Commission-Next Generation EU (Regulation EU2020/2024) through CSIC's Global Health Platform (PTI Salud Global), and PIE-CSIC 202060E194. This work was supported by Instituto de Salud Carlos III, Spanish Ministry of Science and Innovation (COVID-19 Research Call COV20/00181), and co-financed by European Development Regional Fund "A way to achieve Europe." The work was also supported by grants CSIC-COV19-014 from Consejo Superior de Investigaciones Científicas (CSIC), project 525/C/2021 from Fundació La Marató de TV3, PID2020-113888RB-I00 and 202220I116 from Ministerio de Ciencia e Innovación, PI18/00210 and PI21/00139 from Instituto de Salud Carlos III, and S2018/BAA-4370 (PLATESA2 from Comunidad de Madrid/FEDER)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Evaluation of bacterial adherence and biofilm development on an anodized stainless-steel surface for the prevention of osteosynthesis-associated infections

  • Medel-Plaza, M.
  • Arenas, M. A.
  • Aguilera-Correa, John
  • De Bleeckere, Amber
  • Mediero, Aranzazu
  • García, I.
  • Damborenea, Juan de
  • Esteban, Jaime
  • Coenye, Tom
  • Conde del Campo, Ana
Background: Implant-associated infections remain a major challenge in orthopaedic surgery. This study aimed to evaluate the anti-adherent and anti-biofilm properties of a novel anodized 316L stainless-steel (A 316L SS) surface against common pathogens in osteosynthesis-associated infections (OAIs). Methods: Bacterial adherence and biofilm formation of Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecalis, Cutibacterium acnes, Escherichia coli, and Pseudomonas aeruginosa were assessed on A 316L SS and non-anodized 316L stainless steel (Ref 316L SS). Adherence was evaluated after 90 min using fluorescence microscopy. Biofilm development was examined after 24-48 h in synthetic synovial fluid (SSF) using colony counts and scanning electron microscopy (SEM). Results: A 316L SS significantly reduced bacterial adherence and surface coverage for all species tested compared to Ref 316L SS. In biofilm assays, A 316L SS exhibited notable anti-biofilm properties, with significantly reduced biofilm formation for all species. E. faecalis and C. acnes also showed lower planktonic bacterial counts. Imaging confirmed decreased bacterial presence and extracellular matrix on A 316L SS. Conclusions: A 316L SS shows strong anti-adherent and anti-biofilm properties against common orthopaedic pathogens, even under in vivo-like conditions. This surface modification strategy holds significant potential for reducing implant-associated infections and warrants further investigation for clinical applications., This research was funded by the Spanish MICINN project PID2020-112878RB100/AEI/10.13039/501100011033, the European Commission – Next Generation EU (PTI Salud Global), and a grant from the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC). TC received funding from the Research Foundation – Flanders (FWO) (grant no. G066523N) and a Study Group Research Grant from the European Society of Clinical Microbiology and Infectious Diseases (ESCMID). The article processing charges for this open-access publication were covered by the CSIC Open Access Publication Support Initiative through its Unit of Information Resources for Research (URICI), Peer reviewed