Pasar al contenido principal

EL PAPEL DE LA MECANICA EN LA OSTEOPOROSIS: UN MODELO DE DISTRACCION OSTEOGENICA EN OVEJAS OVARIECTOMIZADAS

PID2020-113790RB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2020
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE SEVILLA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

On the influence of structural and chemical properties on the elastic modulus of woven bone under healing

  • Blázquez Carmona, Pablo
  • Mora Macías, Juan
  • Pajares, Antonia
  • Mármol, Álvaro
  • Reina Romo, Esther
Introduction: Woven bone, a heterogeneous and temporary tissue in bone regeneration, is remodeled by osteoblastic and osteoclastic activity and shaped by mechanical stress to restore healthy tissue properties. Characterizing this tissue at different length scales is crucial for developing micromechanical models that optimize mechanical parameters, thereby controlling regeneration and preventing non-unions. Methods: This study examines the temporal evolution of the mechanical properties of bone distraction callus using nanoindentation, ash analysis, micro-CT for trabecular microarchitecture, and Raman spectroscopy for mineral quality. It also establishes single- and two-parameter power laws based on experimental data to predict tissue-level and bulk mechanical properties. Results: At the macro-scale, the tissue exhibited a considerable increase in bone fraction, controlled by the widening of trabeculae. The Raman mineral-to-matrix ratios increased to cortical levels during regeneration, but the local elastic modulus remained lower. During healing, the tissue underwent changes in ash fraction and in the percentages of Calcium and Phosphorus. Six statistically significant power laws were identified based on the ash fraction, bone fraction, and chemical and Raman parameters. Discussion: The microarchitecture of woven bone plays a more significant role than its chemical composition in determining the apparent elastic modulus of the tissue. Raman parameters were demonstrated to provide more significant power laws correlations with the micro-scale elastic modulus than mineral content from ash analysis.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Gait analysis: An effective tool to mechanically monitor the bone regeneration of critical-sized defects in tissue engineering applications

  • Blázquez Carmona, Pablo
  • Mora Macías, Juan
  • Morgaz, Juan
  • Granados, María del Mar
  • Domínguez, Jaime
  • Reina Romo, Esther
Introduction Tissue engineering has emerged as an innovative approach to treat critical-size bone defects using biocompatible scaffolds, thus avoiding complex distraction surgeries or limited stock grafts. Continuous regeneration monitoring is essential in critical-size cases due to the frequent appearance of non-unions. This work evaluates the potential clinical use of gait analysis for the mechanical assessment of a tissue engineering regeneration as an alternative to the traditional and hardly conclusive manual or radiological follow-up. Materials and methods The 15-mm metatarsal fragment of eight female merino sheep was surgically replaced by a bioceramic scaffold stabilized with an external fixator. Gait tests were performed weekly by making the sheep walk on an instrumented gangway. The evolution of different kinematic and dynamic parameters was analyzed for all the animal’s limbs, as well as asymmetries between limbs. Finally, potential correlation in the recovery of the gait parameters was evaluated through the linear regression models. Results After surgery, the operated limb has an altered way of carrying body weight while walking. Its loading capacity was significantly reduced as the stance phases were shorter and less impulsive. The non-operated limbs compensated for this mobility deficit. All parameters were normalizing during the consolidation phase while the bone callus was simultaneously mineralizing. The results also showed high levels of asymmetry between the operated limb and its contralateral, which exceeded 150% when analyzing the impulse after surgery. Gait recovery significantly correlated between symmetrical limbs. Conclusions Gait analysis was presented as an effective, low-cost tool capable of mechanically predicting the regeneration of critical-size defects treated by tissue engineering, as comparing regeneration processes or novel scaffolds. Despite the progressive normalization as the callus mineralized, the bearing capacity reduction and the asymmetry of the operated limb were more significant than in other orthopedic alternatives.
RODIN. Repositorio de Objetos de Docencia e Investigación de la Universidad de Cádiz
Publicación Artículo científico (JournalArticle)

Risk of fragility fracture is aggravated during bone regeneration processes in osteoporotic sheep

  • Toscano Angulo, Juan José
  • Mora Macías, Juan
  • Blázquez Carmona, Pablo
  • Morgaz, Juan
  • Navarrete Calvo, Rocío
  • Domínguez, Jaime
  • Reina Romo, Esther
Introduction Bone regeneration processes are associated with a systemic skeletal change in bone quality, increasing the risk of fragility fractures. This condition may be aggravated in osteoporotic patients due to their limited osteogenic capacity. This work evaluates the impairment of the bone quality in osteoporotic sheep during a bone regeneration process. It provides a deeper understanding about the complex multiscale dynamics of bone mineral density, microstructure and chemical composition across different bone tissues, locations and time points. Materials and Methods Osteoporosis was induced in fifteen Merino sheep. A critical-size defect was then created in the sheep’s right hind metatarsus and subsequently regenerated using distraction osteogenesis. The animals were randomly sacrificed during bone regeneration, either on days 40 or 100 after surgery. Computed tomography, micro-computed tomography and chemical composition analyses were conducted on different bone tissues (cortical, trabecular and woven) at several skeletal locations (the operated metatarsus, the contralateral one and the iliac crest) to assess the individual bone quality changes relative to the non-osteoporotic time point. Results After osteoporosis induction, the trabecular tissue experienced a 6.4% reduction in the bone mineral density, while no significant changes were reported in cortical tissue quality. During bone regeneration, the operated bone increased significantly the woven ossification whilst the cortical mineral density decreased by 18.7%. Simultaneously, an early deterioration in the microstructure and chemical composition of the trabecular bone was observed in the iliac crest, persisting over time in non-operated trabecular regions. Conclusions Osteoporosis causes uneven degradation to trabecular tissue quality across different bone locations. Furthermore, the bone regeneration process via bone transport in osteoporotic subjects leads to a systemic skeletal disorder that further impairs the bone quality, surpassing the damage caused by osteoporosis alone. This impairment appears to be intensified by the pre-existing osteoporotic condition.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Gait analysis: An effective tool to mechanically monitor the bone regeneration of critical-sized defects in tissue engineering applications

  • Blázquez-Carmona, Pablo
  • Mora-Macías, Juan
  • Morgaz, Juan
  • Granados, María del Mar
  • Domínguez, Jaime
  • Reina‐Romo, María Esther
© 2023 Blázquez-Carmona et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited., [Introduction] Tissue engineering has emerged as an innovative approach to treat critical-size bone defects using biocompatible scaffolds, thus avoiding complex distraction surgeries or limited stock grafts. Continuous regeneration monitoring is essential in critical-size cases due to the frequent appearance of non-unions. This work evaluates the potential clinical use of gait analysis for the mechanical assessment of a tissue engineering regeneration as an alternative to the traditional and hardly conclusive manual or radiological follow-up., [Materials and methods] The 15-mm metatarsal fragment of eight female merino sheep was surgically replaced by a bioceramic scaffold stabilized with an external fixator. Gait tests were performed weekly by making the sheep walk on an instrumented gangway. The evolution of different kinematic and dynamic parameters was analyzed for all the animal’s limbs, as well as asymmetries between limbs. Finally, potential correlation in the recovery of the gait parameters was evaluated through the linear regression models., [Results] After surgery, the operated limb has an altered way of carrying body weight while walking. Its loading capacity was significantly reduced as the stance phases were shorter and less impulsive. The non-operated limbs compensated for this mobility deficit. All parameters were normalizing during the consolidation phase while the bone callus was simultaneously mineralizing. The results also showed high levels of asymmetry between the operated limb and its contralateral, which exceeded 150% when analyzing the impulse after surgery. Gait recovery significantly correlated between symmetrical limbs., [Conclusions] Gait analysis was presented as an effective, low-cost tool capable of mechanically predicting the regeneration of critical-size defects treated by tissue engineering, as comparing regeneration processes or novel scaffolds. Despite the progressive normalization as the callus mineralized, the bearing capacity reduction and the asymmetry of the operated limb were more significant than in other orthopedic alternatives., This project was supported by the Ministerio de Ciencia e Innovación (Government of Spain) through the grant number PID2020-113790RB-I00 awarded to JMM and ERR, https://www.aei.gob.es/convocatorias/buscador-convocatorias/proyectos-idi-2020-modalidades-retos-investigacion-generacion, and by the Junta de Andalucía (FEDER-UHU, Programa Operativo FEDER de Andalucía 2014-2020) through the grant number UHU-202058 awarded to JMM, https://www.agenciaandaluzadelaenergia.es/es/financiacion/incentivos-2017-2020/fondo-feder-2014-2020., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Mechanics Predicts Effective Critical-Size Bone Regeneration Using 3D-Printed Bioceramic Scaffolds

  • Blázquez-Carmona, Pablo
  • Mora-Macías, Juan
  • Martínez-Vázquez, Francisco J.
  • Morgaz, Juan
  • Domínguez, Jaime
  • Reina‐Romo, María Esther
© The Author(s) 2023. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/., [BACKGROUND] 3D-printed bioceramic scaffolds have gained popularity due to their controlled microarchitecture and their proven biocompatibility. However, their high brittleness makes their surgical implementation complex for weight-bearing bone treatments. Thus, they would require difficult-to-instrument rigid internal fixations that limit a rigorous evaluation of the regeneration progress through the analysis of mechanic-structural parameters., [METHODS] We investigated the compatibility of flexible fixations with fragile ceramic implants, and if mechanical monitoring techniques are applicable to bone tissue engineering applications. Tissue engineering experiments were performed on 8 ovine metatarsi. A 15 mm bone segment was directly replaced with a hydroxyapatite scaffold and stabilized by an instrumented Ilizarov-type external fixator. Several in vivo monitoring techniques were employed to assess the mechanical and structural progress of the tissue., [RESULTS] The applied surgical protocol succeeded in combining external fixators and subject-specific bioceramic scaffolds without causing fatal fractures of the implant due to stress concentrator. The bearing capacity of the treated limb was initially altered, quantifying a 28–56% reduction of the ground reaction force, which gradually normalized during the consolidation phase. A faster recovery was reported in the bearing capacity, stiffening and bone mineral density of the callus. It acquired a predominant mechanical role over the fixator in the distribution of internal forces after one post-surgical month., [CONCLUSION] The bioceramic scaffold significantly accelerated in vivo the bone formation compared to other traditional alternatives in the literature (e.g., distraction osteogenesis). In addition, the implemented assessment techniques allowed an accurate quantitative evaluation of the bone regeneration through mechanical and imaging parameters., This publication is part of the R+D [Grant No. project PID2020-113790RB-I00], financed by MCIN/AEI/http://orcid.org/10.13039/501100011033. Funding for open access publishing: Universidad de Sevilla/CBUA., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Quantitative atlas of collagen hydrogels reveals mesenchymal cancer cell traction adaptation to the matrix nanoarchitecture

  • Blázquez-Carmona, Pablo
  • Ruiz-Mateos, Raquel
  • Barrasa-Fano, Jorge
  • Shapeti, Apeksha
  • Martín-Alfonso, José Enrique
  • Domínguez, Jaime
  • Van Oosterwyck, Hans
  • Reina-Romo, Esther
  • Sanz-Herrera, José A.
Collagen-based hydrogels are commonly used in mechanobiology to mimic the extracellular matrix. A quantitative analysis of the influence of collagen concentration and properties on the structure and mechanics of the hydrogels is essential for tailored design adjustments for specific in vitro conditions. We combined focused ion beam scanning electron microscopy and rheology to provide a detailed quantitative atlas of the mechanical and nanoscale three-dimensional structural alterations that occur when manipulating different hydrogel's physicochemistry. Moreover, we study the effects of such alterations on the phenotype of breast cancer cells and their mechanical interactions with the extracellular matrix. Regardless of the microenvironment's pore size, porosity or mechanical properties, cancer cells are able to reach a stable mesenchymal-like morphology. Additionally, employing 3D traction force microscopy, a positive correlation between cellular tractions and ECM mechanics is observed up to a critical threshold, beyond which tractions plateau. This suggests that cancer cells in a stable mesenchymal state calibrate their mechanical interactions with the ECM to keep their migration and invasiveness capacities unaltered. STATEMENT OF SIGNIFICANCE: The paper presents a thorough study on the mechanical microenvironment in breast cancer cells during their interaction with collagen based hydrogels of different compositions. The hydrogels' microstructure were obtained using state-of-the-art 3D microscopy, namely focused ion beam-scanning electron microscope (FIB-SEM). FIB-SEM was originally applied in this work to reconstruct complex fibered collagen microstructures within the nanometer range, to obtain key microarchitectural parameters. The mechanical microenvironment of cells was recovered using Traction Force Microscopy (TFM). The obtained results suggest that cells calibrate tractions such that they depend on mechanical, microstructural and physicochemical characteristics of the hydrogels, hence revealing a steric hindrance. We hypothesize that cancer cells studied in this paper tune their mechanical state to keep their migration and invasiveness capacities unaltered., This work was supported by MCIN/AEI/10.13039/501100011033 [PID2020-113790RB-I00, PID2021-126051OB-C42]., Peer reviewed