Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

A new modular neuroprosthesis suitable for hybrid FES-robot applications and tailored assistance

  • Gil-Castillo, Javier|||0000-0002-9311-5506
  • Herrera-Valenzuela, Diana
  • Torricelli, Diego
  • Gil-Agudo, Ángel
  • Opisso, Eloy|||0000-0002-6868-6737
  • Vidal, Joan|||0000-0002-3952-2442
  • Font-Llagunes, Josep M.|||0000-0002-7192-2980
  • del-Ama, Antonio J.|||0000-0001-6215-2593
  • Moreno, Juan C.
Background: To overcome the application limitations of functional electrical stimulation (FES), such as fatigue or nonlinear muscle response, the combination of neuroprosthetic systems with robotic devices has been evaluated, resulting in hybrid systems that have promising potential. However, current technology shows a lack of flexibility to adapt to the needs of any application, context or individual. The main objective of this study is the development of a new modular neuroprosthetic system suitable for hybrid FES-robot applications to meet these needs. Methods: In this study, we conducted an analysis of the requirements for developing hybrid FES-robot systems and reviewed existing literature on similar systems. Building upon these insights, we developed a novel modular neuroprosthetic system tailored for hybrid applications. The system was specifically adapted for gait assistance, and a technological personalization process based on clinical criteria was devised. This process was used to generate different system configurations adjusted to four individuals with spinal cord injury or stroke. The effect of each system configuration on gait kinematic metrics was analyzed by using repeated measures ANOVA or Friedman's test. Results: A modular NP system has been developed that is distinguished by its flexibility, scalability and personalization capabilities. With excellent connection characteristics, it can be effectively integrated with robotic devices. Its 3D design facilitates fitting both as a stand-alone system and in combination with other robotic devices. In addition, it meets rigorous requirements for safe use by incorporating appropriate safety protocols, and features appropriate battery autonomy, weight and dimensions. Different technological configurations adapted to the needs of each patient were obtained, which demonstrated an impact on the kinematic gait pattern comparable to that of other devices reported in the literature. Conclusions: The system met the identified technical requirements, showcasing advancements compared to systems reported in the literature. In addition, it demonstrated its versatility and capacity to be combined with robotic devices forming hybrids, adapting well to the gait application. Moreover, the personalization procedure proved to be useful in obtaining various system configurations tailored to the diverse needs of individuals.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Diseño conceptual de un robot de rehabilitación de la marcha pseudoestacionario, Conceptual design of a pseudo-stationary gait rehabilitation robot

  • Ramos-Rojas, Jaime
  • Lora-Millan, Julio S.
  • Castano, Juan A.
  • Carballeira, Juan
  • Fernández, Pedro R.
  • Borromeo, Susana
[EN] Walking is an extraordinarily complex task that requires the involvement of the entire nervous system, being affected by several neurological abnormalities. All current gait rehabilitation exoskeletons, despite potentially showing improvements, have not conclusively proven their functional superiority to conventional therapy. Furthermore, current robotic devices and gait rehabilitation exoskeletons do not specifically train weight transfer or require a good functional status to be used. This paper presents the conceptual model of an ambulatory robotic system coupled to the Exo-H3 exoskeleton for gait rehabilitation using reinforcement learning strategies. In this way, the aim is to promote neural plasticity by providing greater freedom for the user to explore new movement patterns and to increase their voluntary motor control and active participation, while the exoskeleton adapts and ensures balance and stability. Future steps include the design and fabrication of every robotic subsystem, testing their individual and global performance, with the participation of healthy and pathological subjects., [ES] Caminar es una tarea extraordinariamente compleja que requiere la intervención de todo el sistema nervioso, viéndose afectada por diversas patologías neurológicas. Los exoesqueletos de rehabilitación de la marcha actuales, aunque potencialmente evidencian una mejora tras la rehabilitación, aún no han mostrado su superioridad terapéutica respecto a la terapia convencional de manera concluyente. Además, los dispositivos robóticos y exoesqueletos de rehabilitación de la marcha actuales no permiten entrenar específicamente la transferencia de peso o requieren de un buen estado funcional para ser utilizados. En este artículo se presenta el modelo conceptual de un sistema robótico ambulatorio acoplado al exoesqueleto Exo-H3 para la rehabilitación de la marcha implementando estrategias de aprendizaje por refuerzo. Se espera que este sistema favorezca la plasticidad neuronal al aportar mayor libertad al usuario para explorar nuevos patrones de movimiento y aumentar su control motor voluntario y su participación activa, mientras el exoesqueleto se adapta y garantiza su equilibrio y estabilidad. Los pasos futuros contemplan el diseño y la fabricación de cada uno de los subsistemas robóticos, validando su funcionamiento individual y en conjunto, con la participación de sujetos sanos y patológicos., Este trabajo es parte del proyecto de I+D+i PID2021-123657OB-C31, financiado por MCIN/AEI/10.13039/501100011033/ y por “FEDER Una manera de hacer Europa”.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A qualitative study to elicit user requirements for lower limb wearable exoskeletons for gait rehabilitation in spinal cord injury

  • Herrera Valenzuela, Diana
  • Díaz-Peña, L.
  • Redondo-Galán, C.
  • Arroyo, M.J.
  • Cascante-Gutiérrez, L.
  • Gil-Agudo, Á.
  • Moreno, Juan Camilo
  • Del-Ama, Antonio J.
Objective: We aim to determine a comprehensive set of requirements, perceptions, and expectations that people with spinal cord injury (SCI) and the clinicians in charge of their rehabilitation have regarding the use of wearable robots (WR) for gait rehabilitation. Background: There are concerns due to the limited user acceptance of WR for gait rehabilitation. Developers need to emphasize understanding the needs and constraints of all stakeholders involved, including the real-life dynamics of rehabilitation centers. Methods: 15 people with SCI, 9 without experience with WR and 6 with experience with these technologies, and 10 clinicians from 3 rehabilitation centers in Spain were interviewed. A directed content analysis approach was used. Results: 78 codes grouped into 9 categories (physical results, usability, psychology-related codes, technical characteristics, activities, acquisition issues, context of use, development of the technologies and clinical rehabilitation context) were expressed by at least 20% of the users interviewed, of whom 16 were not found in the literature. The agreement percentage between each group and subgroup included in the study, calculated as the number of codes that more than 20% of both groups expressed, divided over the total amount of codes any of those two groups agreed on (≥ 20%), showed limited agreement between patients and clinicians (50.00%) and between both types of patients (55.77%). The limited accessibility and availability of lower limb exoskeletons for gait rehabilitation arose in most of the interviews. Conclusions: The limited agreement percentage between patients and clinicians indicates that including both types of users in the design process of these technologies is important, given that their requirements are complementary. Engaging users with prior technology experience is recommended, as they often exhibit strong internal consensus and articulate well-defined requirements. This study adds up the knowledge available in the literature and the new codes found in our data, which enlighten important aspects that ought to be addressed in the field to develop technologies that respond to users’ needs, are usable and feasible to implement in their intended contexts. Application: The set of criteria summarized in our study will be useful to guide the design, development, and evaluation of WR for gait rehabilitation to meet user’s needs and allow them to be implemented in their intended context of use., This research has been supported by the Grant RTI2018-097290-B-C31 funded by MCIN/AEI/10.13039/501100011033 and, by “ERDF A way of making Europe”, by the “European Union” and by the Grant PID2021-123657OB-C31 funded by MCIN/AEI/10.13039/501100011033 and by “FEDER A way of making Europe”., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A new modular neuroprosthesis suitable for hybrid FES-robot applications and tailored assistance

  • Gil-Castillo, Javier
  • Herrera Valenzuela, Diana
  • Torricelli, Diego
  • Gil-Agudo, Ángel
  • Opisso, Eloy
  • Vidal, Joan
  • Font-Llagunes, Josep Maria
  • Ama, Antonio J. del
  • Moreno, Juan Camilo
[Background] To overcome the application limitations of functional electrical stimulation (FES), such as fatigue or nonlinear muscle response, the combination of neuroprosthetic systems with robotic devices has been evaluated, resulting in hybrid systems that have promising potential. However, current technology shows a lack of flexibility to adapt to the needs of any application, context or individual. The main objective of this study is the development of a new modular neuroprosthetic system suitable for hybrid FES-robot applications to meet these needs., [Methods] In this study, we conducted an analysis of the requirements for developing hybrid FES-robot systems and reviewed existing literature on similar systems. Building upon these insights, we developed a novel modular neuroprosthetic system tailored for hybrid applications. The system was specifically adapted for gait assistance, and a technological personalization process based on clinical criteria was devised. This process was used to generate different system configurations adjusted to four individuals with spinal cord injury or stroke. The effect of each system configuration on gait kinematic metrics was analyzed by using repeated measures ANOVA or Friedman’s test., [Results] A modular NP system has been developed that is distinguished by its flexibility, scalability and personalization capabilities. With excellent connection characteristics, it can be effectively integrated with robotic devices. Its 3D design facilitates fitting both as a stand-alone system and in combination with other robotic devices. In addition, it meets rigorous requirements for safe use by incorporating appropriate safety protocols, and features appropriate battery autonomy, weight and dimensions. Different technological configurations adapted to the needs of each patient were obtained, which demonstrated an impact on the kinematic gait pattern comparable to that of other devices reported in the literature., [Conclusions] The system met the identified technical requirements, showcasing advancements compared to systems reported in the literature. In addition, it demonstrated its versatility and capacity to be combined with robotic devices forming hybrids, adapting well to the gait application. Moreover, the personalization procedure proved to be useful in obtaining various system configurations tailored to the diverse needs of individuals., This research has been partially supported by grant DTS23/00047 funded by ISCIII and cofunded by the European Union, and partially supported by Grants RTI 2018-097290-B-C31 and PID2021-123657OB-C31 funded by MCIN/AEI/https://doi.org/10.13039/501100011033 and by “ERDF A way of making Europe”. Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Exploring the feasibility of combining transcutaneous electrical spinal cord stimulation and overground robotic exoskeleton for gait rehabilitation in patients with spinal cord injury

  • Algaba-Vidoy, Marina
  • Pérez-Nombela, Soraya
  • Megía-García, Álvaro
  • Montero-Pardo, Cristina
  • Redondo-Galán, Carolina
  • de Los Reyes-Guzmán, Ana
  • Serrano-Muñoz, Diego
  • Gómez-Soriano, Julio
  • Del-Ama, Antonio J
  • Moreno, Juan C
Spinal cord injury (SCI) is a traumatic condition that causes severe sensory and mobility impairments, including gait dysfunction. Combining exoskeleton-assisted gait training (EGT) with transcutaneous spinal cord stimulation (tSCS) may enhance motor recovery in SCI patients. This study explores the feasibility and immediate effects of combining these two neurorehabilitation strategies, without pursuing clinical benefits., The author(s) declare that financial support was received for the research and/or publication of this article. This research was funded by the “Junta de Comunidades de Castilla-La Mancha” and “Fondos FEDER” (EXO-STIM project, grant number SBPLY/19/180501/000316), the EXPLORA 2017 program (Recode project, grant number: DPI2017-91117-EXP) and by Instituto de Salud Carlos III (ISCIII) through project DTS23/00047 and co-funded by the European Union, by Grant RED2022-134319-T funded by MCIN/AEI/10.13039/501100011033, and Grant PID2021-123657OB-C31 funded by MCIN/AEI/10.13039/501100011033 and by “ERDF A way of making Europe.”, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Using HD-EMG to Assess Motor Units in Vastus Lateralis With the Lokomat: A Pilot Study With Young, Elderly and Individuals Post-Stroke

  • Corvini, G
  • Lorusso, M
  • Tagliamonte, N.L
  • Masciullo, M
  • Molinari, M
  • Scivoletto, G
  • Tamburella, F
  • Moreno, J.C
High-Density Electromyography (HD-EMG) shows strong potential in research, but its translation into clinical rehabilitation remains limited. This pilot study explores the feasibility of integrating a portable HD-EMG system into a standardized rehabilitation test using the Lokomat, a robotic gait trainer widely employed in neurorehabilitation. By decomposing EMG signals and analyzing Motor Unit (MU) properties, this study aims to assess neuromuscular differences related to age and poststroke conditions. Three groups (healthy young, healthy elderly, and chronic stroke survivors) performed isometric sub-maximal knee extensions at 30%, 50%, and 70% of their maximum force. EMG signals were recorded from the Vastus Lateralis muscle using a 64-channel electrode grid. Conventional EMG parameters (e.g., envelope and median frequency) failed to differentiate between groups. In contrast, MU-level analysis revealed fewer detected MUs and lower discharge rates in elderly participants, along with stroke-related alterations in MU recruitment and muscle relaxation. These findings demonstrate both the feasibility and added diagnostic value of HD-EMG in routine clinical robotic rehabilitation. HD-EMG offers objective, detailed insights into neuromuscular functions and could support the optimization of rehabilitation strategies. Further research is needed to validate its clinical applicability in larger populations and promote the adoption of HD-EMG as a standard diagnostic tool, This study has been carried out with partial support of research project Grant ID PID2021-123657OB-C31 funded by Ministerio de Ciencia e Innovación/Agencia Estatal de Investigación/FEDER Next Generation and with the partial support of the Italian Ministry of Health (Ricerca Corrente). The funding was also partially provided by the Instituto de Salud Carlos III (ISCIII) through project DTS23/00047 and co-funded by the European Union, by Grant RED2022-134319-T funded by MCIN/AEI/ 10.13039/501100011033., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Development and clinical validation of a stroke-specific Gait Deviation Index

  • Sanz Morere, Clara Beatriz
  • Sánchez del Valle, Clara
  • Herrera Valenzuela, Diana
  • Barria, Patricio
  • Del Ama, Antonio J.
  • Moreno, Juan C
Stroke affects over 101 million individuals worldwide, leaving many to cope with long-term consequences. These often include physical and cognitive impairments such as muscle weakness, loss of coordination, and challenges in performing daily activities. Several quantitative indices have been developed to objectively quantify gait deviations with a focus on ensuring ease of use and accessibility within clinical settings. Among those, the most cited one is the Gait Deviation Index (GDI), originally developed with data from a population of children with cerebral palsy. This characteristic probably reduces the ability of the GDI to interpret stroke-specific deviations. To overcome this limitation, one possibility is to derive a GDI for each specific population, as demonstrated for spinal cord injury. In this study, we developed a stroke-specific GDI (STR-GDI) considering a database of 22 healthy controls and 69 post-stroke subjects. The STR-GDI with a 17-feature basis provided a more reliable reconstruction of non-native data compared to the 15-feature original GDI basis. Both GDI and STR-GDI showed excellent reliability across limbs and datasets (ICC = 0.99), although STR-GDI showed higher ICCs in the test set for the non-paretic limbs (0.95 compared to 0.91 for the GDI). Regression models between GDI and STR-GDI yielded R-2 values of 0.76 and 0.81, respectively for the paretic and non-paretic limbs. The linear regressions between indexes and clinical and gait variables were less consistent but still meaningful, with R-2 values lower than 0.23. These results may indicate that these metrics offer complementary information, and their combined use could provide a more comprehensive understanding of post-stroke gait impairments. STR-GDI showed slightly higher correlations than GDI with the lower-limb Fugl-Meyer Assessment, the percentage of stance phase, step length, and cadence. In conclusion, in this study we successfully adapted the original GDI methodology to create a STR-GDI to capture gait deviations specific to post-stroke individuals. This study makes a meaningful methodological contribution by developing and validating a complete automatic pipeline that could be adapted to generate other condition-specific GDIs for other neurological or musculoskeletal disorders, provided that datasets are available. Future work will expand the STR-GDI using a larger and more diverse stroke population, assess its inter-session reliability, and develop a compatible version for inertial measurement units and markerless motion capture systems, facilitating broader clinical and real-world applications., This research is part of the NIMBLE project PID2021- 123657OB-C31, funded by MCIN/AEI/https:/ /doi.or g/10.13 039/ 501100011033 and by the European Regional Development Fund (FEDER, UE)., Peer reviewed