Pasar al contenido principal

SISTEMA ROBOTICO PARALELO CON CONTROL BASADO EN MODELO MUSCULO-ESQUELETICO PARA LA MONITORIZACION Y ENTRENAMIENTO DEL SISTEMA PROPIOCEPTIVO

PID2021-125694OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 21
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A Type II singularity avoidance algorithm for parallel manipulators using output twist screws

  • Pulloquinga-Zapata, José
  • Escarabajal-Sánchez, Rafael José
  • Valera Fernández, Ángel|||0000-0001-6843-6394
  • Vallés Miquel, Marina|||0000-0002-6396-0098
  • Mata Amela, Vicente|||0000-0003-2255-0567
[EN] Parallel robots (PRs) are closed-chain manipulators with diverse applications due to their accuracy and high payload. However, there are configurations within the workspace named Type II singularities where the PRs lose control of the end-effector movements. Type II singularities are a problem for applications where complete control of the end-effector is essential. Trajectory planning produces accurate movements of a PR by avoiding Type II singularities. Generally, singularity avoidance is achieved by optimising a geometrical path with a velocity profile considering singular configurations as obstacles. This research presents an algorithm that avoids Type II singularities by modifying the trajectory of a subset of the actuators. The subset of actuators represents the limbs responsible for a Type II singularity, and they are identified by the angle between two Output Twist Screws. The proposed avoidance algorithm does not require optimisation procedures, which reduces the computational cost for offline trajectory planning and makes it suitable for online trajectory planning. The avoidance algorithm is implemented in offline trajectory planning for a pick and place planar PR and a spatial knee rehabilitation PR., Acknowledgements This research was partially funded by Fondo Europeo de Desarrollo Regional (PID2021-125694OB-I00) , cofounded by Vicer-rectorado de Investigacion de la Universitat Politecnica de Valencia (PAID-11-21) and by Programa de Ayudas de Investigacion y Desarrollo de la Universitat Politecnica de Valencia (PAID-01-19) . Funding for open access charge: CRUE-Universitat Politecnica de Valencia. Moreover, the authors would like to thank the help of all anonymous reviewers, which have improved the paper's readability.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Relationship between neck kinematics and neck dissability index. An approach based on functional regression

  • Aragón-Basanta, Elisa
  • Venegas, William
  • Ayala, Guillermo
  • Serra-Añó, Pilar
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
[EN] Numerous studies use numerical variables of neck movement to predict the level of severity of a pathology. However, the correlation between these numerical variables and disability levels is low, less than 0.4 in the best cases, even less in subjects with nonspecific neck pain. This work aims to use Functional Data Analysis (FDA), in particular scalar-on-function regression, to predict the Neck Disability Index (NDI) of subjects with nonspecific neck pain using the complete movement as predictors. Several functional regression models have been implemented, doubling the multiple correlation coefficient obtained when only scalar predictors are used. The best predictive model considers the angular velocity curves as a predictor, obtaining a multiple correlation coefficient of 0.64. In addition, functional models facilitate the interpretation of the relationship between the kinematic curves and the NDI since they allow identifying which parts of the curves most influence the differences in the predicted variable. In this case, the movement¿s braking phases contribute to a greater or lesser NDI. So, it is concluded that functional regression models have greater predictive capacity than usual ones by considering practically all the information in the curve while allowing a physical interpretation of the results.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Robotic assessment of proprioception in individuals with patellar tendinopathy: A feasibility and pilot study

  • Munoz-Gomez, Elena
  • Gonzalez-Pons, Hector
  • Ingles, Marta
  • Moreno-Segura, Noemi
  • Molla-Casanova, Sara
  • Serra-Añó, Pilar
  • Vallés Miquel, Marina|||0000-0002-6396-0098
  • Valera Fernández, Ángel|||0000-0001-6843-6394
[EN] Background: Individuals with patellar tendinopathy often exhibit impaired proprioception, which may contribute to symptom persistence and injury recurrence. A parallel robotic system based on a musculoskeletal knee model has shown valid and reliable performance for assessing joint position sense (JPS). This study aims to evaluate the feasibility of a protocol for the robotic assessment of knee proprioception in individuals with patellar tendinopathy and to compare their proprioceptive performance with that of healthy controls. Methods: Twenty-one participants with patellar tendinopathy (PTG) and fifteen healthy individuals (CG) (mean age: 32.36 (9.53) years) completed a single session of knee proprioception evaluation. JPS was assessed at 30 degrees and 50 degrees using passive (PJPS) and active (AJPS) repositioning tasks. Findings: The PTG exhibited greater absolute angular error than the CG during PJPS at 30 degrees (p = 0.04) and 50 degrees (p = 0.04), and during AJPS at 30 degrees (p = 0.01), with no differences detected in the 50 degrees AJPS task (p > 0.05). The feasibility analysis showed that perceived effort, difficulty, and pain were generally low, whereas comfort and satisfaction were rated highly. Interpretation: This study supports the use of a parallel robotic system as a viable instrument for assessing knee proprioception in people with patellar tendinopathy. Significant proprioceptive deficits were identified in this population compared to healthy controls, particularly in passive JPS at 30 degrees and 50 degrees, and in active JPS at 30 degrees., This study was funded by the Spanish Government (PID2021-125694OB-I00: co-financed by EU FEDER funds) ; the Conselleria d'Innovacio , Universitats, Ciencia i Societat, Generalitat Valenciana (CIAICO/2021/107) ; and the Spanish Government (FPU23/01464) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The Reliability and Accuracy of a Fall Risk Assessment Procedure Using Mobile Smartphone Sensors Compared with a Physiological Profile Assessment

  • PEDRERO, J.F.
  • De Rosario Martínez, Helios
  • Medina Ripoll, Enrique
  • Garrido Jaen, Jose David
  • Serra-Añó, Pilar
  • Mollà-Casanova, Sara
  • Lopez Pascual, Juan
[EN] Falls in older people are a major health concern as the leading cause of disability and the second most common cause of accidental death. We developed a rapid fall risk assessment based on a combination of physical performance measurements made with an inertial sensor embedded in a smartphone. This study aimed to evaluate and validate the reliability and accuracy of an easy-to-use smartphone fall risk assessment by comparing it with the Physiological Profile Assessment (PPA) results. Sixty-five participants older than 55 performed a variation of the Timed Up and Go test using smartphone sensors. Balance and gait parameters were calculated, and their reliability was assessed by the (ICC) and compared with the PPAs. Since the PPA allows classification into six levels of fall risk, the data obtained from the smartphone assessment were categorised into six equivalent levels using different parametric and nonparametric classifier models with neural networks. The F1 score and geometric mean of each model were also calculated. All selected parameters showed ICCs around 0.9. The best classifier, in terms of accuracy, was the nonparametric mixed input data model with a 100% success rate in the classification category. In conclusion, fall risk can be reliably assessed using a simple, fast smartphone protocol that allows accurate fall risk classification among older people and can be a useful screening tool in clinical settings., Activity developed within the framework of several fundings: i. CERVERA Network financed by the Ministry of Science and Innovation through the Center for Industrial Technological Development charged to the General State Budgets 2021, and the Recovery, Transformation, and Resilience Plan (CER20211003); ii. State Plan for Scientific and Technical Research and Innovation (Knowledge Generation) co-financed by EU FEDER funds (PID2021-125694OB-I00); iii. Consolidated research groups program from Generalitat Valenciana, Conselleria d¿Innovació, Universitats, Ciència i Societat: CIAICO/2021/215; iv. Talent attraction program from Universitat de València (INV19-01-13-07).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Muscle-Targeted Robotic Assistive Control Using Musculoskeletal Model of the Lower Limb

  • Escarabajal, Rafael J.
  • Zamora-Ortiz, Pau
  • Pulloquinga, José L.
  • Vallés Miquel, Marina|||0000-0002-6396-0098
  • Valera Fernández, Ángel|||0000-0001-6843-6394
[EN] Conventional assistive and rehabilitative robotic systems often overlook human biomechanics, particularly muscular forces, as they predominantly operate in joint or task space and focus on position and exchanged forces. Similarly, traditional manual rehabilitation techniques employed by physiotherapists struggle to obtain quantitative measurements and make precise modifications to key human variables, resulting in predominantly qualitative methods and outcomes. In response to these limitations, this article introduces an innovative assistive robot controller that operates in the muscular space, targeting specific muscles in the lower limb, and distinguishing itself from existing solutions that focus primarily on joint or task space. A key innovation of our approach is the real-time measurement of muscular forces during dynamic tasks, obtained from a calibrated musculoskeletal model. These measurements enable the establishment of a multistep closed-loop controller, with the outer loop precisely tracking the desired muscular forces. Implemented within a configurable viscous environment, the controller provides a natural response for the user. Experimental evaluations conducted using a parallel robot designed for rehabilitation demonstrate the controller¿s efficacy. Incorporating the outer loop reduced the median relative error of the tracked muscular force by nearly 80% and decreased the variability of this error by over 85% compared to a pure viscous environment defined as the baseline. These findings highlight the potential applications of this control framework in areas, such as assistive robotics and precision rehabilitation. By achieving objective measurement and control, the system may enhance rehabilitation outcomes, offering tailored exercises that match the individual needs, capabilities, and engagement of each patient., This work was supported in part by the Agencia Estatal de Investigacion (Ministerio de Ciencia e Innovacion, Spanish Government)/Fondos FEDER under Project PID2021-125694OB-I00; in part by the Conselleria de Innovacion, Universidades, Ciencia y Sociedad Digital (Generalitat Valenciana) under Project CIAICO/2023/074; and in part by the Ministerio de Universidades, Spanish Government, under Grant FPU18/05105.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Application of functional regression in biomechanical assessment of neck disability: Selection of clinically relevant variables

  • Aragon-Basanta, Ma Elisa
  • Ayala, Guillermo
  • Serra-Ano, Pilar
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
[EN] Background: The Neck Disability Index (NDI) is widely used to assess neck pain-related disability. It is commonly combined with objective measures, particularly range of motion and peak velocity, but these variables usually show weak correlations with patient-reported outcomes. Functional data analysis (FDA) makes it possible to analyze complete kinematic waveforms and provides tools to identify relevant motion features most related to disability.Objective: This study aimed to examine whether scalar-on-function regression of cervical angular velocity curves can predict NDI scores in patients with nonspecific neck pain and which motion variables and sub-phases contribute most to the prediction.Methods: We analyzed 56 recordings from 28 patients, each paired with an NDI questionnaire, which were collected over two sessions. Cervical flexion-extension, lateral flexion, and axial rotation velocities were processed using functional principal component analysis to reduce dimensionality while retaining the main modes of variation.Univariate and bivariate scalar-on-function regression models were estimated. Model selection was based on a procedure that combined the Akaike Information Criterion, Bayesian Information Criterion, and measures of goodness-of-fit, ensuring a balance between model simplicity and predictive accuracy. Comparisons were made using non-functional regressions, including demographic and anthropometric variables.Results: The bivariate flexion-extension plus lateral flexion model showed the best performance (r = 0.677), which was clearly higher than that of the non-functional regressions (r <= 0.391). The coefficient functions indicated that the acceleration and deceleration phases were the most informative in explaining variability in NDI scores. The inclusion of anthropometric variables did not improve model performance.Conclusions: Functional regression of velocity curves improves the prediction of NDI scores and highlights specific phases of movement that are clinically relevant. Larger studies are required to confirm these findings and assess their clinical applicability., This publication is part of the I+D+i project PGC type B with reference PID2020-117114GBI00 funded by the Spanish Ministry of Science, Innovation and Universities, MCIN/AEI/10.13039/501100011033/ (G. A.) and project CIPROM/2023/066 (G. A.) Also, it is part of the project PID2021-125694OB-I00 funded by MICIU/AEI//10.13039/501100011033 and FEDER/UE (P. S.A. and A.P.) and CIAICO/2021/215 (P.S.A.). There was no additional external funding received for this study. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Imitation Learning-Based System for the Execution of Self-Paced Robotic-Assisted Passive Rehabilitation Exercises

  • Escarabajal-Sánchez, Rafael José
  • Pulloquinga-Zapata, José
  • Zamora-Ortiz, Pau
  • Valera Fernández, Ángel|||0000-0001-6843-6394
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Vallés Miquel, Marina|||0000-0002-6396-0098
[EN] The development of robotic-assisted rehabilitation exercises involving physical human-robot interaction requires extreme care since an injured limb may be in physical contact with the robot, so compliant behavior is imperative for these tasks. Typical approaches involve force control schemes like admittance controllers that allow humans to adapt the motion. However, when the patient¿s limb has limited mobility or is potentially injured, unintentional forces may occur during the robot¿s trajectory that could be incompatible with these controllers. This letter addresses a new way of generating compliant trajectories for passive rehabilitation exercises, considering that previous positions of the trajectory are attainable for the patient, so reversing the trajectory is a safe op eration. Since there is no clear way to optimize such a goal due to the physiological variability among patients, the condition of reversal is based on imitation learning by taking the analogous healthy limb of the patient as a reference and encoding the forces using Gaussian Mixture Regression, and reversibility is accomplished by means of Reversible Dynamic Movement Primitives. The system allows for self-paced rehabilitation exercises by back-and-forth movements along the trajectory according to the patient¿s reaction, and it has been successfully applied to a 4-DOF parallel robot for lower-limb rehabilitation., This work was supported in part by the Fondo Europeo de Desarrollo Regional under Grant PID2021-125694OB-I00, in part by the Vicerrectorado de Investigación de la Universitat Politècnica de València under Grant PAID-11-21, and in part by the Ministerio de Universidades, Gobierno de España under Grant FPU18/05105
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Combined Admittance Control With Type II Singularity Evasion for Parallel Robots Using Dynamic Movement Primitives

  • Escarabajal-Sánchez, Rafael José
  • Pulloquinga-Zapata, José
  • Castillo-García, Fernando J.
  • Valera Fernández, Ángel|||0000-0001-6843-6394
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Vallés Miquel, Marina|||0000-0002-6396-0098
[EN] This article addresses a new way of generating compliant trajectories for control using movement primitives to allow physical human-robot interaction where parallel robots (PRs) are involved. PRs are suitable for tasks requiring precision and performance because of their robust behavior. However, two fundamental issues must be resolved to ensure safe operation: first, the force exerted on the human must be controlled and limited, and second, Type II singularities should be avoided to keep complete control of the robot. We offer a unified solution under the dynamic movement primitives (DMP) framework to tackle both tasks simultaneously. DMPs are used to get an abstract representation for movement generation and are involved in broad areas, such as imitation learning and movement recognition. For force control, we design an admittance controller intrinsically defined within the DMP structure, and subsequently, the Type II singularity evasion layer is added to the system. Both the admittance controller and the evader exploit the dynamic behavior of the DMP and its properties related to invariance and temporal coupling, and the whole system is deployed in a real PR meant for knee rehabilitation. The results show the capability of the system to perform safe rehabilitation exercises., This work was supported in part by the Fondo Europeo de Desarrollo Regional under Grant PID2021-125694OB-I00, in part by the Vicerrectorado de Investigacion de la Universitat Politecnica de Valencia under Grant PAID-11-21, and in part by the Ministerio de Universidades, Gobierno de Espana under Grant FPU18/05105.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Model-Based Control of a 4-DOF Rehabilitation Parallel Robot with Online Identification of the Gravitational Term

  • Escarabajal-Sánchez, Rafael José
  • Pulloquinga-Zapata, José Luis
  • Díaz-Rodríguez, Miguel
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Valera Fernández, Ángel|||0000-0001-6843-6394
[EN] Parallel robots are being increasingly used as a fundamental component of lower-limb rehabilitation systems. During rehabilitation therapies, the parallel robot must interact with the patient, which raises several challenges to the control system: (1) The weight supported by the robot can vary from patient to patient, and even for the same patient, making standard model-based controllers unsuitable for those tasks since they rely on constant dynamic models and parameters. (2) The identification techniques usually consider the estimation of all dynamic parameters, bringing about challenges concerning robustness and complexity. This paper proposes the design and experimental validation of a model-based controller comprising a proportional-derivative controller with gravity compensation applied to a 4-DOF parallel robot for knee rehabilitation, where the gravitational forces are expressed in terms of relevant dynamic parameters. The identification of such parameters is possible by means of least squares methods. The proposed controller has been experimentally validated, holding the error stable following significant payload changes in terms of the weight of the patient¿s leg. This novel controller allows us to perform both identification and control simultaneously and is easy to tune. Moreover, its parameters have an intuitive interpretation, contrary to a conventional adaptive controller. The performance of a conventional adaptive controller and the proposed one are compared experimentally., This research was partially funded by Fondo Europeo de Desarrollo Regional (PID2021-125694OB-I00), cofounded by Vicerrectorado de Investigación de la Universitat Politècnica de València (PAID-11-21) and by Ministerio de Universidades, Gobierno de España (FPU18/05105).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Non-specific neck pain evaluation using functional linear models with the limma correction

  • Aragon-Basanta, Ma Elisa
  • Ayala, Guillermo
  • Serra-Añó, Pilar
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
[EN] We have analyzed the relationship between disability and neck flexion-extension kinematics in non-specific neck pain subjects. A functional approach is used considering the angle, velocity, and acceleration curves. Different regression models have been fitted for each time in order to obtain these curves using scalar predictors such as the Neck Disability Index (NDI), age, sex, and neck length. In addition to classical regression, a limma (Linear Models for Microarray Data) model has been used, which improves the fit by modifying the estimation of the variances of the different fits using an empirical Bayes approach. As point-by-point adjustments are performed, this introduces a multiple comparison problem, and the corresponding p-values have to be adjusted in order to control the false discovery rate (FDR). In particular, a Benjamini-Hochberg method was used. The results show significant differences between raw and adjusted p-values for all variables, so spurious results were detected, e.g., the effect of neck length on velocity and acceleration curves. Differences between usual multiple linear regressions and the modified fits using the limma method (limma models) are minor, with a slight decrement of p-values in limma models. Once the p-values are adjusted, none of the variables analyzed significantly affects the angular curves. In contrast, NDI and age affect velocity and acceleration curves. Furthermore, the study of p-values throughout the movement shows that velocity and acceleration curves provide complementary information, so they should be used together in neck kinematics studies., Open Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature. This research was supported by the Spanish Government and co-financed by EU FEDER funds PID2020-117114GB-I00 and CIPROM/2023/066 (G. Ayala), PID2021-125694OB-I00 (P. Serra-Ano, A. Page) and CIAICO/2021/215 (P. Serra-Ano).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Applying Screw Theory to Design the Turmell-Bot: A Cable-Driven, Reconfigurable Ankle Rehabilitation Parallel Robot

  • Vargas-Riaño, Julio
  • Agudelo-Varela, Óscar
  • Valera Fernández, Ángel|||0000-0001-6843-6394
[EN] The ankle is a complex joint with a high injury incidence. Rehabilitation Robotics applied to the ankle is a very active research field. We present the kinematics and statics of a cable-driven reconfigurable ankle rehabilitation robot. First, we studied how the tendons pull mid-foot bones around the talocrural and subtalar axes. We proposed a hybrid serial-parallel mechanism analogous to the ankle. Then, using screw theory, we synthesized a cable-driven robot with the human ankle in the closed-loop kinematics. We incorporated a draw-wire sensor to measure the axes' pose and compute the product of exponentials. We also reconfigured the cables to balance the tension and pressure forces using the axis projection on the base and platform planes. Furthermore, we computed the workspace to show that the reconfigurable design fits several sizes. The data used are from anthropometry and statistics. Finally, we validated the robot's statics with MuJoCo for various cable length groups corresponding to the axes' range of motion. We suggested a platform adjusting system and an alignment method. The design is lightweight, and the cable-driven robot has advantages over rigid parallel robots, such as Stewart platforms. We will use compliant actuators for enhancing human-robot interaction., This research was partially funded by Colciencias-Colfuturo PhD Scholarships Program Educational Credit Forgivable grant number 568, and by Agencia Estatal de Investigacion (Ministerio de Ciencia e Innovacion, Spanish Government) and Fondo Europeo de Desarrollo Regional through the Project ref. PID2021-125694OB-I00.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effects of mirror neuron activation therapies on functionality in older adults: Systematic review and meta-analysis

  • Mollà-Casanova, Sara
  • Lopez Pascual, Juan
  • Inglés, Marta
  • Sempere-Rubio, Nuria
  • Aguilar-Rodríguez, Marta
  • Muñoz-Gomez, Elena
  • Serra-Añó, Pilar
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
[EN] Purpose: To identify the effects of mirror neuron activation (MNAT) combined or not with physical exercise (PE) in healthy older adults, on functionality, balance, gait velocity and risk of falls. Methods: A systematic electronic search was performed in PubMed/MEDLINE, Cochrane, and Embase databases. Results: Thirteen randomized controlled trials were included in the qualitative analysis, and eleven in the quantitative analysis. All studies showed fair to high quality and the most frequent high-risk bias was "Blinding of participants and personnel". Compared to the control condition, higher improvement was shown in older people who received MNAT, on functionality (1.57 [0.57, 2.62], balance (1.95 [1.32, 2.572]), and gait velocity (1.20 [0.30, 2.11]). Compared to PE, MNAT combined with PE does not improve functionality. More studies are needed to assess MNAT effectiveness in the rest of the outcomes. Conclusions: Neuron system activation through MNAT improves relevant abilities in older adults, with better results when including functional activities. However, the beneficial effects on these variables of adding MNAT to a PE program are controversial., This work was partially supported by Grants from the Spanish Government (PID2021-125694OB-I00; co-financed by EU FEDER funds), and Generalitat Valenciana, Conselleria d'Innovacio, Universitats, Ciencia i Societat (CIAICO/2021/215).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Admittance controller complemented with real-time singularity avoidance for rehabilitation parallel robots

  • Pulloquinga-Zapata, José Luis
  • Escarabajal-Sánchez, Rafael José
  • Díaz-Rodríguez, Miguel
  • Vallés Miquel, Marina|||0000-0002-6396-0098
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Valera Fernández, Ángel|||0000-0001-6843-6394
[EN] Rehabilitation tasks demand robust and accurate trajectory-tracking performance, mainly achieved with parallel robots. In this field, limiting the value of the force exerted on the patient is crucial, especially when an injured limb is involved. In human-robot interaction studies, the admittance controller modifies the location of the robot according to the user efforts driving the end-effector to an arbitrary location within the workspace. However, a parallel robot has singularities within the workspace, making implementing a conventional admittance controller unsafe. Thus, this study proposes an admittance controller that overcomes the limitations of singular configurations by using a real-time singularity avoidance algorithm. The singularity avoidance algorithm modifies the original trajectory based on the actual location of the parallel robot. The complemented admittance controller is applied to a 4 degrees of freedom parallel robot for knee rehabilitation. In this case, the actual location is measured by a 3D tracking system because the location calculated by the forward kinematics is inaccurate in the vicinity of a singularity. The experimental results verify the effectiveness of the proposed admittance controller for safe knee rehabilitation exercises., Acknowledgements This research was partially funded by Fondo Europeo de Desarrollo Regional (PID2021-125694OB-I00), cofounded by Programa de Ayudas de Investigacion y Desarrollo de la Universitat Politecnica de Valencia (PAID-01-19). Funding for open access charge: CRUE-Universitat Politecnica de Valencia.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A Computationally Efficient Musculoskeletal Model of the Lower Limb for the Control of Rehabilitation Robots: Assumptions and Validation

  • Farhat, Nidal
  • Zamora-Ortiz, Pau
  • Reichert, David
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Valera Fernández, Ángel|||0000-0001-6843-6394
[EN] We present and validate a computationally efficient lower limb musculoskeletal model for the control of a rehabilitation robot. It is a parametric model that allows the customization of joint kinematics, and it is able to operate in real time. Methods: Since the rehabilitation exercises corresponds to low-speed movements, a quasi-static model can be assumed, and then muscle force coefficients are position dependent. This enables their calculation in an offline stage. In addition, the concept of a single functional degree of freedom is used to minimize drastically the workspace of the stored coefficients. Finally, we have developed a force calculation process based on Lagrange multipliers that provides a closed-form solution; in this way, the problem of dynamic indeterminacy is solved without the need to use an iterative process. Results: The model has been validated by comparing muscle forces estimated by the model with the corresponding electromyography (EMG) values using squat exercise, in which the Spearman¿s correlation coefficient is higher than 0.93. Its computational time is lower than 2.5 ms in a conventional computer using MATLAB. Conclusions: This procedure presents a good agreement with the experimental values of the forces, and it can be integrated into real time control systems., This research was partially funded by EU FEDER (predoctoral grant PRE2018-083847 and grand project "Sistema robotico paralelo con control basado en modelo musculo-esqueletico para la monitorizacion y entrenamiento del sistema propioceptivo", reference PID2021-125694OB-I00), and cofounded by Vicerrectorado de Investigacion de la Universitat Politecnica de Valencia (PAID-11-21).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Validación de un modelo dinámico del cuello para aplicaciones en ergonomía y valoración funcional, Validation of a dynamic model of the neck for applications in ergonomics and functional assessment

  • Venegas-Toro, William-Ricardo
  • Medina-Fabara, Ana
  • Zambrano-Orejuela, Iván
  • Rosales-Acosta, Andrés
  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
[ES] Se presenta un modelo dinámico del cuello para su aplicación en valoración funcional o estudios de ergonomía, a partir de datos obtenidos mediante equipamiento biomecánico convencional: sistema de video fotogrametría y plataformas de fuerzas. El modelo utiliza parámetros inerciales de la cabeza y el cuello obtenidos mediante ecuaciones de regresión que se ajustan posteriormente en un proceso de calibración. El movimiento de la cabeza se registra mediante un sistema de video fotogrametría convencional. A partir de las coordenadas de los marcadores se calculan los desplazamientos finitos, velocidades y aceleraciones lineales y angulares. Las fuerzas externas se miden con una plataforma de fuerzas. Mediante un planteamiento de dinámica inversa se estiman fuerzas y momentos a nivel de C7, así como la potencia desarrollada. El modelo se ha validado mediante un estudio experimental con 30 participantes, comparando las estimaciones del modelo con las medidas en una plataforma de fuerzas. Los resultados muestran una correspondencia excelente entre las estimaciones y las medidas experimentales, con una correlación superior a 0.976 y un error estándar inferior al 1% del peso de la cabeza., [EN] A dynamic neck model is proposed for functional assessment or ergonomic studies using data from conventional biomechanical tools such as video photogrammetry and force platforms. Head and neck inertial parameters are obtained through regression equations and refined through a calibration process to improve accuracy. Head movement is recorded through video photogrammetry, where marker coordinates are used to calculate finite displacements, linear and angular velocities, and accelerations. An inverse dynamics approach estimates the forces and moments at the C7 vertebral level and the generated muscle power. The model was validated through an experimental study with 30 participants, where its estimates were compared to the measurements obtained from a force platform. The comparison aimed to assess the accuracy and reliability of the model. The results show excellent agreement, with a correlation of 0.976 or higher and a standard error of less than 1% of the head weight, This work has been funded by the National Polytechnic School of Ecuador (Project PIS 20-04) and by the Ministry of Science and Innovation of the Government of Spain (Plan Estatal de Investigacion Cientifica, Tecnica y de Investigacion 2021-2023, project PID2021-125694OB-100).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Sensor-Based Identification of Singularities in Parallel Manipulators

  • Pulloquinga-Zapata, José Luis
  • Ceccarelli, Marco
  • Mata Amela, Vicente|||0000-0003-2255-0567
  • Valera Fernández, Ángel|||0000-0001-6843-6394
[EN] Singularities are configurations where the number of degrees of freedom of a robot changes instantaneously. In parallel manipulators, a singularity could reduce the mobility of the end-effector or produce uncontrolled motions of the mobile platform. Thus, a singularity is a critical problem for mechanical design and model-based control. This paper presents a general sensor-based method to identify singularities in the workspace of parallel manipulators with low computational cost. The proposed experimental method identifies a singularity by measuring sudden changes in the end-effector movements and huge increments in the forces applied by the actuators. This paper uses an inertial measurement unit and a 3D tracking system for measuring the end-effector movements, and current sensors for the forces exerted by the actuators. The proposed sensor-based identification of singularities is adjusted and implemented in three different robots to validate its effectiveness and feasibility for identifying singularities. The case studies are two prototypes for educational purposes-a five-bar mechanism and an L-CaPaMan parallel robot-and a four-degree-of-freedom robot for rehabilitation purposes. The tests showcase its potential as a practical solution for singularity identification in educational and industrial robots., This research was partially funded by Fondo Europeo de Desarrollo Regional (PID2021-125694OB-I00), cofounded by Erasmus+ project: Mechatronics for Improving and Standardizing Competences in Engineering (2022-1-ES01-KA220-HED-00089155).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Inter-Rater and Intra-Rater Reliability and Validity of a Parallel Robotic System With Musculoskeletal Model-Based Feedback for Monitoring the Proprioceptive System in Healthy Individuals

  • Muñoz-Gómez, Elena
  • Inglés, Marta
  • Pulloquinga-Zapata, José Luis
  • Moreno-Segura, Noemí
  • Mollà-Casanova, Sara
  • Serra-Añó, Pilar
  • Vallés Miquel, Marina|||0000-0002-6396-0098
  • Ivorra, Eugenio|||0000-0001-6062-2061
[EN] Background: Knee proprioception is essential for injury prevention, stability, and performance improvement. Reliable proprioception measurement tools are crucial for accurate assessment and effective rehabilitation. Thus, the aim of the present study was to determine the validity and reliability of a parallel robotic system with musculoskeletal model-based feedback to assess knee joint position sense (JPS) in healthy people. Material/Methods: Fourteen healthy participants (7 men and 7 women) (mean (SD) age = 35.21 (9.32) years) volunteered for the study. The validity, inter-rater and intra-rater reliability of a parallel robotic system for measuring JPS were evaluated. Results: The results indicate moderate to strong reliability in the 30¿ JPS test (ICC = 0.41-0.66; SEM = 0.27-0.37), and strong to excellent reliability in the 50¿ JPS test (ICC = 0.64-0.87; SEM = 0.31-0.45). Significant concurrent validity with correlations of variable strength was detected between the inclinometer and the robot in the 30¿ JPS tests (Pearson¿s correlation = 0.52-0.66; SEM = 0.30-0.43), and in the 50¿ JPS tests (Pearson¿s correlation = 0.55; SEM = 0.44) but only for the passive motion in closed kinetic chain. Conclusions: A parallel robotic system with musculoskeletal model-based knee measurement provides a valid and reliable method for assessing knee JPS in healthy people. Its precision makes it a promising tool for both clinical use and future research applications., This work was supported in part by Spanish Government co-financed by European Union (EU) European Regional Development Fund (ERDF) Funds under Grant PID2021-125694OB-I00; and in part by the Generalitat Valenciana, Conselleria d Innovacio, Universitats, Ci ¿ encia i Societat under Grant ` CIAICO/2021/215 and Grant CIAICO/2023/074.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Tesis doctoral (DoctoralThesis)

Design and Implementation of Model-Based and Learning Control for Rehabilitation Parallel Robots: Advancements and Performance Evaluation

  • Escarabajal Sánchez, Rafael José
[ES] La era actual se caracteriza por una creciente población envejecida debido al aumento de la esperanza de vida y a una tasa de natalidad en declive. Este cambio demográfico conlleva un aumento de las discapacidades, lo que enfatiza la importancia del envejecimiento saludable y la capacidad funcional. En respuesta a estos desafíos, se están explorando metodologías de asistencia innovadoras, particularmente en la integración de la interacción física humano-robot. Los Robots Paralelos (PRs) son cadenas cinemáticas cerradas que exhiben ventajas para la rehabilitación de extremidades humanas, gracias a su rigidez, precisión y robustez. Sin embargo, su modelado complejo y la presencia de singularidades dentro del espacio de trabajo plantean un desafío para garantizar una interacción segura y efectiva. Este documento propone una colección de nuevos algoritmos de control utilizando un PR que cubren un amplio espectro de aplicaciones dentro del contexto de la robótica asistencial, que van desde el entrenamiento pasivo (en el que el usuario no genera los movimientos, por lo que se induce un esfuerzo mínimo o nulo) hasta ejercicios activos (que requieren contracciones musculares voluntarias del paciente) y aumento de potencia. El primer algoritmo aborda el desafío del seguimiento de trayectorias con un controlador basado en modelos con intercambio de fuerzas entre el humano y el robot en ausencia de un sensor de fuerza. Al incluir un mecanismo para estimar esta fuerza de interacción en línea utilizando Mínimos Cuadrados (LS) dentro del modelo, se proporciona información valiosa para terapeutas u otros algoritmos, y reduce continuamente los errores de seguimiento corrigiendo el modelo dinámico en línea. En situaciones de entrenamiento activo, los controladores basados en fuerza son esenciales para responder a las interacciones. La tesis incorpora un control de admitancia con un sensor de fuerza. A pesar de los beneficios de esta interacción, existen riesgos asociados con la modificación de las trayectorias del robot por parte del humano, debido a la presencia de singularidades dentro del espacio de trabajo que se deben evitar para garantizar la seguridad del paciente. Se utilizan las Primitivas de Movimiento Dinámico (DMP) para codificar la trayectoria inicial, que puede modificarse con términos de acoplamiento para lograr ambos objetivos de control de admitancia y evasión de singularidades simultáneamente. En las primeras etapas de la rehabilitación, los pacientes pueden carecer de habilidades motoras debido a una lesión, por lo que se deben emplear ejercicios pasivos. Esta investigación propone un mecanismo inteligente para ejercicios pasivos que permite a los usuarios regresar a posiciones seguras previas y reanudar el ejercicio de manera autónoma. La inversión de trayectoria se logra con las Primitivas de Movimiento Dinámico Reversibles (RDMP). El enfoque implica codificar el comportamiento esperado utilizando datos de la extremidad sana análoga y revertir la trayectoria cuando el miembro lesionado se desvía de los patrones, bajo el paradigma de Aprendizaje por Imitación. Por último, los modelos musculoesqueléticos desempeñan un papel crucial en la estimación de las fuerzas musculares del usuario, siendo de gran utilidad integrados en controladores en el espacio muscular. Estos controladores pueden aplicarse tanto en contextos de aumento de potencia como de rehabilitación. En el aumento de potencia, el concepto de manipulabilidad describe la capacidad del humano para ejercer fuerzas en cualquier dirección. Lograr una manipulabilidad isotrópica es deseable para mantener una activación muscular constante, y este estudio investiga su representación mediante un concepto novedoso llamado envolvente de fuerza. Además, esta investigación explora el uso de controladores musculares en entornos de asistencia o rehabilitación, mediante un controlador en bucle cerrado diseñado para inducir fuerzas de tensión específicas en los músculos., [CA] L'era actual es caracteritza per una creixent població envellida a causa de l'augment de l'esperança de vida i una taxa de natalitat en declivi. Aquest canvi demogràfic comporta un augment de les discapacitats, la qual cosa destaca la importància de l'envelliment saludable i la capacitat funcional. En resposta a aquests reptes, s'estan explorant metodologies d'assistència innovadores, particularment en la integració de la interacció física humà-robot. Els Robots Paral·lels (PRs) són cadenes cinemàtiques tancades que exhibeixen avantatges per a la rehabilitació d'extremitats humanes, gràcies a la seua rigidesa, precisió i robustesa. No obstant això, el seu modelatge complex i la presència de singularitats dins de l'espai de treball planteja un desafiament per a garantir una interacció segura i efectiva. Aquest document proposa una col·lecció de nous algoritmes de control utilitzant un PR que cobreixen un ampli espectre d'aplicacions dins del context de la robòtica assistencial, que van des de l'entrenament passiu (en el qual l'usuari no genera els moviments, per la qual cosa s'indueix un esforç mínim o nul) fins a exercicis actius (que requereixen contraccions musculars voluntàries del pacient) i augment de potència. El primer algoritme aborda el desafiament del seguiment de trajectòries amb un controlador basat en models amb intercanvi de forces entre l'ésser humà i el robot en absència d'un sensor de força. En incloure un mecanisme per estimar aquesta força d'interacció en línia utilitzant Mínims Quadrats (LS) dins del model, es proporciona informació valuosa per a terapeutes o altres algoritmes, i redueix contínuament els errors de seguiment corregint el model dinàmic en línia. En situacions d'entrenament actiu, els controladors basats en força són essencials per respondre adequadament a les interaccions. La tesi incorpora un control d'admitància amb un sensor de força. Malgrat els beneficis d'aquesta interacció, existeixen riscos associats amb la modificació de les trajectòries del robot per part de l'ésser humà, degut a la presència de singularitats dins de l'espai de treball que s'han de evitar per garantir la seguretat del pacient. Les Primitives de Moviment Dinàmic (DMP) s'utilitzen per a codificar la trajectòria inicial, que es pot modificar amb termes d'acoblament per aconseguir ambdós objectius de control d'admitància i evitar les singularitats simultàniament. En les primeres etapes de la rehabilitació, els pacients poden mancar d'habilitats motrius a causa d'una lesió, per la qual cosa s'han d'emplear exercicis passius. Aquesta investigació proposa un mecanisme intel·ligent per a exercicis passius que permet als usuaris tornar a posicions segures prèvies i reprendre l'exercici de manera autònoma. La inversió de trajectòria s'aconsegueix amb les Primitives de Moviment Dinàmic Reversibles (RDMP). L'enfocament implica codificar el comportament esperat utilitzant dades de l'extremitat sana anàloga i revertir la trajectòria quan el membre lesionat es desvia dels patrons, sota el paradigma d'Aprenentatge per Imitació. Finalment, els models musculoesquelètics juguen un paper crucial en l'estimació de les forces musculars de l'usuari, sent de gran utilitat integrats en controladors en l'espai muscular. Aquests controladors es poden aplicar tant en contextos d'augment de potència com de rehabilitació. En l'augment de potència, el concepte de manipulabilitat descriu la capacitat de l'ésser humà per exercir forces en qualsevol direcció. Aconseguir una manipulabilitat isotròpica és desitjable per mantenir una activació muscular constant, i aquest estudi investiga la seua representación mitjançant un concepte innovador anomenat envolvent de força. A més, aquesta investigació explora l'ús de controladors musculars en entorns d'assistència o rehabilitació, mitjançant un controlador en bucle tancat dissenyat per induir forces de tensió específiques en els músculs., [EN] The current era is characterized by a growing elderly population due to increased life expectancy and a declining birth rate. This demographic shift leads to a rise in disabilities, emphasizing the importance of healthy aging and functional ability. In response to these challenges, innovative assistive methodologies are being explored, particularly in the integration into physical human-robot interaction. Parallel Robots (PRs) are closed kinematic chains that exhibit unique advantages for human limb rehabilitation, thanks to their stiffness, accuracy, and robustness. However, their complex modeling and the presence of singularities within the workspace pose a challenge to ensure safe and effective interaction. This document proposes a collection of novel control algorithms using a PR to cover a wide spectrum of applications within the context of assistive robotics, ranging from passive training (in which the user does not generate the movements, so minimal to no effort is induced) to active exercises (requiring the patient's voluntary muscle contractions) and power augmentation. The first algorithm addresses the challenge of trajectory tracking with a model-based controller with force exchange between the human and the robot in the absence of a force sensor. By including a mechanism to estimate this interaction force online using Least Squares (LS) within the model, the algorithm provides valuable insight for therapists or other algorithms and continuously reduces tracking errors by correcting the dynamic model online. In active training scenarios, force-based controllers are essential to respond appropriately to interactions. The thesis incorporates an admittance controller with a force sensor. Despite the benefits of this interaction, there are risks associated with human modification of robot trajectories due to the presence of singularities within the workspace that must be avoided to ensure the patient's safety. Dynamic Movement Primitives (DMP) are employed to encode the initial trajectory, which can be modified with coupling terms to achieve both objectives of admittance control and singularity avoidance simultaneously. In the early stages of rehabilitation, patients may lack full motor skills due to the injury, so passive exercises should be employed. This research proposes an intelligent mechanism for passive exercises that allows users to return to previous safe positions and resume the exercise in a self-paced manner. The trajectory reversal is achieved with Reversible Dynamic Movement Primitives (RDMP). The approach involves encoding the expected behavior using data from the analogous healthy limb and reversing the trajectory when the injured limb deviates from the established statistical patterns. This approach aligns with the paradigm of Imitation Learning. Finally, musculoskeletal models play a crucial role in estimating the user's muscle forces, offering significant utility when integrated in controllers operating in muscular space. These controllers can be applied in both power augmentation and rehabilitation contexts. In power augmentation, the concept of manipulability describes the human's ability to exert forces in any direction. Achieving isotropic manipulability is desirable to maintain constant muscular activation, and this study investigates its representation with a novel concept called a force envelope. Furthermore, this research explores the use of muscle-targeted controllers in assistance or rehabilitation settings, by means of a closed-loop controller designed to induce specific tension forces in muscles., This research was funded in part by Fondo Europeo de Desarrollo Regional (PID2021-125694OB-I00), and in part by Vicerrectorado de Investigación de la Universitat Politècnica de València (PAID-11-21). The author received a scholarship from Ministerio de Universidades, Gobierno de España, under grant Ayudas para la Formación de Profesorado Universitario (FPU18/05105). The author’s research stay at Jožef Stefan Institute was funded partly by Vicer- rectorado de Investigación de la Universitat Politècnica de València (PAID-11- 21), and partly by Erasmus+ Student Mobility for Traineeship 2020.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Tesis doctoral (DoctoralThesis)

Modelo músculo-esquelético del miembro inferior para rehabilitación con robot paralelo

  • Zamora Ortiz, Pau
[ES] El aumento de la esperanza de vida y la inversión de la pirámide poblacional plantean un desafío al sector sanitario debido al incremento de lesiones articulares y cirugías reconstructivas per cápita. Esto aumenta la demanda de personal rehabilitador en una sociedad con menos población activa. La robotización de las terapias puede aliviar esta presión al automatizar los ejercicios repetitivos. Además, el uso de tecnologías como los modelos músculo-esqueléticos mejoran las terapias, acortando los tiempos de recuperación y optimizan los resultados. La aplicación de modelos músculo-esqueléticos en robots de rehabilitación garantiza la seguridad del paciente al limitar las fuerzas excesivas y evitar posiciones peligrosas. Al mismo tiempo, brinda información adicional al personal rehabilitador para un seguimiento más preciso y personalizado de las terapias a los pacientes. Sin embargo, estos modelos son costosos computacionalmente, lo que dificulta su implementación en el control de robots. En el proyecto en el cual se integra esta tesis, se ha establecido el objetivo de construir un robot de rehabilitación que integre un modelo músculo-esquelético capaz de calcular en tiempo real las fuerzas musculares y articulares. Conocer las fuerzas garantiza la seguridad del paciente, proporciona información sobre las fuerzas durante los ejercicios y optimiza las terapias. Además, a partir del modelo músculo-esquelético se busca desarrollar nuevas herramientas para personalizar los ejercicios y mejorar los resultados. El modelo del miembro inferior, con seis grados de libertad, se ha simplificado para garantizar el cálculo en tiempo real. Se ha utilizado el concepto de grado de libertad funcional para predecir las relaciones entre los grados de libertad en un ejercicio concreto, reduciendo la carga computacional y permitiendo su uso en tiempo real durante los ejercicios de rehabilitación. El modelo consta de tres grados de libertad para la cadera, simulando una junta esférica, modelada como tres pares de revolución perpendiculares entre sí, uno para la rodilla, modelada como un mecanismo de cuatro barras, que simula el movimiento relativo entre el fémur y la tibia, y dos grados de libertad para el tobillo. Se calcula el centro de giro de la cadera y los parámetros del mecanismo de cuatro barras mediante ejercicios de calibración articular para lograr una mayor personalización del modelo. El tobillo se ha modelado empleando los datos de Klein Horsman debido a su dificultad de calibración. Del mismo trabajo se han tomado los parámetros musculares, los cuales se han simplificado para reducir el coste computacional. Se calculan las tensiones musculares mediante las condiciones de Karush-Kuhn-Tucker, minimizando el sumatorio cuadrático de las tensiones de los músculos. El modelo se ha validado y verificado siguiendo las recomendaciones de buenas prácticas de Hicks. Se han comparado los resultados del presente modelo con otro similar generado en AnyBody y con los datos empíricos del ``Grand Challenge", se ha analizado la solidez del modelo frente a las simplificaciones realizadas y los errores de los datos de entrada. Según los resultados obtenidos, el modelo músculo-esquelético es lo suficientemente preciso para ser utilizado en un robot de rehabilitación, garantizando la seguridad de los pacientes y prediciendo la activación muscular. Por último, se han desarrollado dos nuevas herramientas utilizando el modelo actual. La primera estima la Máxima Contracción Voluntaria del sujeto proyectando las fuerzas musculares al efector final del robot. La segunda herramienta calcula la fuerza externa necesaria para garantizar una fuerza muscular específica. Empleando ambas herramientas se logra una mayor personalización de las terapias de rehabilitación, mejorando el proceso. Ambas herramientas han sido probadas empleando el robot de rehabilitación., [CA] L'augment de l'esperança de vida i la inversió de la piràmide poblacional plantegen un desafiament al sector sanitari a causa de l'increment de lesions articulars i cirurgies reconstructives. Això augmenta la demanda de personal rehabilitador en una societat amb menys població activa. La robotització de les teràpies pot alleujar aquesta pressió a l'autoritzar els exercisses repetitius. A més, l'ús de tecnologies com els models múscul-esquelètics milloren les teràpies, acurtant els temps de recuperació i optimitzant els resultats. L'aplicació de models múscul-esquelètics en robots de rehabilitació garanteix la seguretat del pacient en limitar les forces excessives i evitar posicions perilloses. Al mateix temps, ofereix informació addicional al personal rehabilitador per a un seguiment més precís i personalitzat de les teràpies als pacients. No obstant això, aquests models són costosos computacionalment, el que dificulta la seua implementació en el control de robots. En el projecte en el qual s'integra aquesta tesi, s'ha establit l'objectiu de construir un robot de rehabilitació que integre un model múscul-esquelètic capaç de calcular en temps real les forces musculars i articulars. Conéixer les forces garanteix la seguretat del pacient, proporcionant informació sobre les forces durant els exercicis i optimitza les teràpies. A més, a partir del model múscul-esquelètic es busca desenvolupar noves ferramentes per a personalitzar els exercicis millorar els resultats. El model del membre inferior, amb sis graus de llibertat, s'ha simplificat per garantir el càlcul en temps real. S'ha utilitzat el concepte de grau de llibertat funcional per a predir les relacions entre els graus de llibertat d'un exercici concret, reduint la càrrega computacional i permitent el seu ús en temps real durant els exercisses de rehabilitació. El model consta de tres graus de llibertat per al maluc, simulant una junta esfèrica, modelant com tres parells de revolucions perpendiculars entre si, un per al genoll, modelat com un mecanisme de quatre barres, què simula el moviment relatiu entre el fèmur i la tíbia, i dos graus de llibertat per al turmell. Es calcula el centre de gir del maluc i els paràmetres del mecanisme de quatre barres mitjançant exercicis de calibratge articular per a aconseguir una major personalització del model. El turmell s'ha modelat emprant les dades de Klein Horsman a causa de la seua dificultat de calibració. Del mateix treball s'han pres els paràmetres musculars, els quals s'han simplificat per a reduir el cost computacional. S'ha calculat les tensions musculars mitjançant les condicions de Karush-Kuhn-Tucker, minimitzant el sumatori quadràtic de les tensions musculars. El model s'ha validat i verificat seguint les recomanacions de bones pràctiques d'Hicks. S'ha comparat els resultats del present model amb altre similar generat en AnyBody i amb les dades empíriques del ''Grand Challenge", s'ha analitzat la solidesa del model enfront de les simplificacions realitzades i els errors de les dades d'entrada. Segons els resultats obtinguts, el model múscul-esquelètic és prou precís per a ser utilitzat en un robot de rehabilitació, garantint la seguretat dels pacients i predient l'activació muscular. En últim lloc, s'han desenvolupat dues noves ferramentes utilitzant el model actual. La primera estima la Màxima Contracció Voluntària del subjecte projectant les forces musculars a l'efector final del robot. La segona ferramenta calcula la força externa necessària per a garantir una força muscular específica. Emprant totes dues eines s'aconsegueix una major personalització de les teràpies de rehabilitació, millorant el procés. Totes dues ferramentes han sigut provades fent servir el robot de rehabilitació., [EN] Increasing life expectancy and the inversion of the population pyramid pose a challenge to the healthcare sector due to the rise in joint injuries and reconstructive surgeries per capita. This increases the demand for rehabilitation personnel in a society with a smaller active population. The robotization of therapies can alleviate this pressure by automating repetitive exercises. Furthermore, the use of technologies like musculoskeletal models enhances therapies, reducing recovery times, and optimizing outcomes. The application of musculoskeletal models in rehabilitation robots ensures patient safety by limiting excessive forces and avoiding dangerous positions. At the same time, it provides additional information to rehabilitation personnel for more precise and personalized monitoring of patient therapies. However, these models have a high computational cost, which makes their implementation in robot control challenging. In the project that integrates this thesis, the objective has been set to build a rehabilitation robot that incorporates a musculoskeletal model capable of real-time calculation of muscular and joint forces. Understanding these forces ensures patient safety, provides information about forces during exercises, and optimizes therapies. Additionally, based on the musculoskeletal model, new tools are being developed to personalize exercises and improve results. The lower limb model, with six degrees of freedom, has been simplified to enable real-time calculation. The concept of functional degrees of freedom has been used to predict the relationships between degrees of freedom in a specific exercise, reducing the computational burden and enabling real-time use during rehabilitation exercises. The model consists of three degrees of freedom for the hip, simulating a spherical joint, modeled as three sets of perpendicular revolute pairs, one for the knee, modeled as a four-bar mechanism, that simulates the relative movement between the femur and the tibia, and two degrees of freedom for the ankle. The hip's pivot center and the parameters of the four-bar mechanism have been calculated through joint calibration exercises to achieve a higher level of model personalization. The ankle has been modeled using Klein Horsman's data due to its calibration complexity. Muscle parameters from the same work have been taken and simplified to reduce computational costs. Muscle tensions are calculated using the Karush-Kuhn-Tucker conditions, minimizing the squared sum of muscle tensions. The model has been validated and verified following Hicks' best practices recommendations. The results of this model have been compared with a similar one generated in AnyBody and with empirical data from the ``Grand Challenge". The model's robustness against the made simplifications and input data errors has been analyzed. According to the obtained results, the musculoskeletal model is accurate enough to be used in a rehabilitation robot, ensuring patient safety and predicting muscle activation. Finally, two new tools have been developed using the current model. The first one estimates the Maximum Voluntary Contraction of the subject by projecting muscular forces to the robot's end effector. The second tool calculates the external force required to achieve a specific muscular force. By employing both tools, greater personalization of rehabilitation therapies is achieved, improving the process. Both tools have been tested using the rehabilitation robot., Esta tesis y la investigación realizada han sido financiadas por la Agencia Estatal de Investigación con los proyectos “Integración de modelos biomecánicos en el desarrollo y operación de robots rehabilitadores reconfigurables” (DPI2017-84201-R-AR) y “Sistema robótico paralelo con control basado en modelo músculo-esquelético para la monitorización y entrenamiento del sistema propioceptivo” (PID2021-125694OB-I00). El autor de la presente tesis recibió la beca de la Agencia Estatal de Investigación: Ayuda para contrato predoctoral para la formación de doctores Zamora Ortiz, Pau. (PRE2018-083847). Con la cual ha podido dedicarse a tiempo completo a la formación e investigación que ha dado como fruto esta tesis doctoral.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of non-specific neck pain on the path of the instantaneous axis of rotation of the neck during its flexion-extension movement

  • Page Del Pozo, Alvaro Felipe|||0000-0002-5432-310X
  • Inglés, Marta
  • Venegas, William
  • Mollà-Casanova, Sara
  • Serra-Añó, Pilar
[EN] Non-specific neck pain is a common musculoskeletal disorder with a high prevalence and involves impaired joint movement pattern. Therefore, this study aimed to compare the trajectory of the instantaneous axis of rotation(IAR) in flexion-extension movements of the neck between people with and without nonspecific neck pain, using functional data analysis techniques. Furthermore, possible relationships between neck kinematics and perceived pain and disability were explored. Seventy-three volunteers participated in this cross-sectional study. They were allocated in a non-specific pain group (PG, n = 28) and a control group (CG, n = 45). A cyclic flexion-extension movement was assessed by a video photogrammetry system and numerical and functional variables were computed to analyze IAR trajectory during movement. Moreover, to explore possible relationships of these variables with pain and neck disability, a visual analogue scale (VAS) and the neck disability index (NDI) were used. The instantaneous axis of rotation trajectory during the flexion-extension cyclic movement described a path like Greek letter rho both in the CG and the PG, but this trajectory was shorter and displaced upward in the PG, compared to the CG. A reduction of the displacement range and a rise in the vertical position of the IAR were related to VAS and NDI scores. Non-specific neck pain is associated with a higher location of the instantaneous axis of rotation and a decrease in length of the path traveled during the flexion-extension movement. This study contributes to a better description of neck movement in people with non-specific neck pain, which would help to plan an individualized treatment., This work was partially supported by the Spanish Government and co-financed by EU FEDER funds (Grant PID2021-125694OB-I00), by the Escuela Politecnica Nacional de Quito (Proj. PIS 20-04) and by the Universitat de Valencia (INV19-01-13-07).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Estimation of the equivalent external force using a musculoskeletal model withmuscle coactivation

  • Zamora-Ortiz, Pau
  • Escarabajal, Rafael J.
  • Pulloquinga, José L.
  • Valera Fernández, Ángel|||0000-0001-6843-6394
  • Vallés Miquel, Marina|||0000-0002-6396-0098
[EN] The present work introduces a novel method to determine the force vector that a subject must exert at the end of a limb in order to achieve the desired muscle force, taking into account muscle coactivation. The obtained force vector is referred to as the equivalent external force, as it represents the exerted force at the end-effector needed to provoke a desired muscle force. By using a musculoskeletal model of the lower limb and applying the Karush-Kuhn-Tucker conditions, a precise solution has been achieved to calculate the equivalent external force at the foot for the desired muscle force. The method has been tested with a four-degree-of-freedom robot, generating optimal activation trajectories for the vasti and confirming that the desired force level is achieved. The results validate the effectiveness of the proposed method and highlight its potential applications in both medical rehabilitation and sports training. This significant advancement in the field of biomechanics would provide a valuable tool for health and sports professionals, improving training and rehabilitation strategies., This work was partially funded by the Agencia Estatal de Investigacion (Ministerio de Ciencia e Innovacion, Spanish Government) and Fondos FEDER through the project ref. PID2021-125694OB-I00 and by the Conselleria de Innovacion, Universidades, Ciencia y Sociedad Digital (Generalitat Valenciana) through the project ref. CIAICO/2023/074.