Pasar al contenido principal

PROTEOMICA Y MIRNOMICA DIRIGIDA PARA ABORDAR BIOMARCADORES DE ENFERMEDADES INFECCIOSAS, NEURODEGENERATIVAS Y CANCER

PID2021-127137OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE BARCELONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Development of a trifluoroacetic acid-free liquid chromatography-mass spectrometry method for protein profiling of bovine milk and authentication of A2 milk, Desarrollo de un método de cromatografía líquida-espectrometría de masas sin ácido trifluoroacético para el perfil proteico de la leche bovina y la autenticación de la leche A2

  • Tehrani, Tahereh|||0009-0009-2893-3033
  • Pont, Laura|||0000-0003-0520-0450
  • Juan Godoy, Bibiana|||0000-0002-6870-179X
  • Trujillo, Antonio-José|||0000-0003-1437-6060
  • Benavente, Fernando|||0000-0002-1688-1477
Las proteínas de la leche, en particular las caseínas y las proteínas del suero, son esenciales para las propiedades nutricionales y funcionales de la leche. Sin embargo, comprender su composición detallada y sus variaciones genéticas requiere técnicas analíticas precisas y fiables. En este estudio, presentamos un nuevo método para la determinación del perfil proteico de la leche bovina mediante cromatografía líquida con absorción ultravioleta y detección por espectrometría de masas (LC-UV y LC-MS, respectivamente). Inicialmente, se desarrolló un método LC-UV de fase reversa, utilizando una columna C4 de poro ancho y fases móviles de acetonitrilo:agua con ácido fórmico (HFor) al 0,1 % (v/v), en sustitución del ácido trifluoroacético (TFA), agente de apareamiento iónico comúnmente utilizado. El TFA no se recomienda en las mejores prácticas para LC-MS, ya que interfiere con la ionización por electrospray (ESI) en línea y contamina el espectrómetro de masas debido a sus efectos de supresión iónica. Al adoptar HFor en LC-UV, el tiempo total de análisis se redujo en 10 minutos y la separación se vio ligeramente afectada. Además, el método sin TFA fue totalmente compatible con LC-MS, demostrando un rendimiento consistente con bajas desviaciones estándar relativas (%RSD) en el tiempo de retención y el área de pico a lo largo de secuencias extensas de análisis, sin contaminación del espectrómetro de masas. El análisis LC-MS se realizó utilizando un espectrómetro de masas de alta resolución con tiempo de vuelo (TOF), lo que permitió la identificación y cuantificación precisas de proteínas clave de la leche bovina a partir de fracciones de suero y caseína, incluyendo proteoformas con sutiles diferencias estructurales, como la β-caseína (β-CN) A1 y A2. Esto permitió la diferenciación entre varios genotipos de β-caseína (A1A1, A1A2 y A2A2) y la cuantificación de bajos niveles de contaminación de la leche A2A2 con leche A1A1. Estos hallazgos resaltan el potencial del método para la investigación láctea de alto rendimiento, confiable y eficiente, el control de calidad y la autenticación, sin comprometer el rendimiento del espectrómetro de masas., Milk proteins, particularly caseins and whey proteins, are essential to the nutritional and functional properties of milk. However, understanding their detailed composition and genetic variations requires precise and reliable analytical techniques. In this study, we present a novel method for protein profiling of bovine milk using liquid chromatography with ultraviolet absorption and mass spectrometry detection (LC-UV and LC-MS, respectively). Initially, a reversed-phase LC-UV method was developed, using a wide-pore C4 column and acetonitrile: water mobile phases with 0.1 % (v/v) formic acid (HFor), replacing the commonly used ion-pairing agent trifluoroacetic acid (TFA). TFA is not recommended in best practices for LC-MS, as it interferes with on-line electrospray ionization (ESI) and contaminate the mass spectrometer due to its ion-suppression effects. By adopting HFor in LC-UV, the total analysis time was reduced by 10 min, and separation was slightly affected. Moreover, the TFAfree method was fully compatible with LC-MS, demonstrating consistent performance with low relative standard deviations (%RSDs) in retention time and peak area across extended sequences of analyses, with no mass spectrometer contamination. LC-MS analysis was performed using an accurate mass, high-resolution time-of-flight (TOF) mass spectrometer, enabling accurate identification and quantification of key bovine milk proteins from whey and casein fractions, including proteoforms with subtle structural differences, such as beta-casein (beta-CN) A1 and A2. This allowed differentiation between various beta-casein genotypes (A1A1, A1A2, and A2A2) and the quantification of low levels of contamination of A2A2 milk with A1A1 milk. These findings highlight the method's potential for high-throughput, reliable, and efficient dairy research, quality control, and authentication, without compromising the mass spectrometer performance.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Rapid and Highly Efficient Separation of i-Motif DNA Species by CE-UV and Multivariate Curve Resolution

  • Bchara, Laila
  • Eritja Casadellà, Ramón
  • Gargallo, Raimundo
  • Benavente, Fernando
The i-motif is a class of nonstandard DNA structure with potential biological implications. A novel capillary electrophoresis with an ultraviolet absorption spectrophotometric detection (CE-UV) method has been developed for the rapid analysis of the i-motif folding equilibrium as a function of pH and temperature. The electrophoretic analyses are performed in reverse polarity of the separation voltage with 32 cm long fused silica capillaries permanently coated with hydroxypropyl cellulose (HPC), after an appropriate conditioning procedure was used to achieve good repeatability. However, the electrophoretic separation between the folded and unfolded conformers of the studied cytosine-rich i-motif sequences (i.e., TT, Py39WT, and nmy01) is compromised, especially for Py39WT and nmy01, which result in completely overlapped peaks. Therefore, deconvolution with multivariate curve resolution-alternating least-squares (MCR-ALS) has been required for the efficient separation of the folded and unfolded species found at different concentration levels at pH 6.5 and between 12 and 40 °C, taking advantage of the small dissimilarities in the electrophoretic mobilities and UV spectra levels. MCR-ALS has also provided quantitative information that has been used to estimate melting temperatures (Tm), which are similar to those determined by UV and circular dichroism (CD) spectroscopies. The obtained results demonstrate that CE-UV assisted by MCR-ALS may become a very useful tool to get novel insight into the folding of i-motifs and other complex DNA structures., The authors thank funding from MCIN/AEI/10.13039/501100011033 and “ERDF A way of making Europe” (Grants PID2019-107158GB-I00, PID2020-118145RB-I00, and PID2021-127137OB-I00)., Peer reviewed