Pasar al contenido principal

DESARROLLO DE METODOS RAPIDOS BASADOS EN ESPECTROMETRIA DE MASAS PARA LA DETERMINACION DE BIOMARCADORES DE EXPOSICION Y DE EFECTO. ESTUDIOS DE CORRELACION.

PID2021-127679NB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2021
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE SALAMANCA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Dispersive liquid-liquid aerosol phase extraction for the determination of acetylated bromophenols in urine by gas chromatography – mass spectrometry

  • Sánchez, Raquel|||/items/06c6cd36-b88e-43e0-929a-9b92d670da54
  • Peña, Javier
  • Todolí Torró, José Luis|||/items/e63cf980-21e8-48ec-8493-cdb380f1cccc
  • González-Mariño, Iria
Background. Bromophenols are urinary biomarkers of human exposure to brominated flame retardants, but their determination remains challenging because they occur at ultra-trace levels in this complex biological matrix. Results Under optimized conditions, the acetylating reagent (acetic anhydride) and the extracting solvent (heptane) are nebulized directly into the buffered urine sample, generating an interfacial surface area that accelerates mass transfer. The extraction is completed in 80 s and yields a ready-to-inject organic extract through spontaneous phase separation, avoiding the time-consuming centrifugation steps typically required in conventional liquid-liquid extraction. The method demonstrated satisfactory trueness (recoveries of 74–130 %), good overall precision with RSD values generally ≤20 %, and limits of quantification ranging from 70 to 370 pg mL-1 in human urine. Finally, it was successfully applied to urine samples from five healthy adult volunteers with no known exposure to brominated flame retardants, allowing the quantification of several mono-, di-, and tri-bromophenols at sub-ng mL-1 levels. Significance The study represents the first application of DLLAPE to the extraction of organic compounds from aqueous matrices, specifically from urine. It provides a rapid, solvent-minimized, and high-throughput alternative to conventional liquid-liquid extraction for the determination of bromophenols in urine.