Pasar al contenido principal

CONTROL DE GLUCOSA EN MUJERES VERSUS HOMBRES: HACIA TERAPIAS DE INSULINA ESPECIFICAS POR SEXO EN DIABETES TIPO 1

PID2022-137723OB-C22

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT DE GIRONA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 2
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Accuracy of FreeStyle Libre 3 During Moderate-Intensity Continuous Aerobic Exercise at Different Phases of the Menstrual Cycle in Females with Type 1 Diabetes

  • Cuerda del Pino, Alba
  • Laguna Sanz, Alejandro José
  • Díez, José-Luís
  • Rossetti, Paolo
  • Romero, Cynthia Marco
  • Ampudia-Blasco, F. Javier
  • Martín-San Agustín, Rodrigo
  • Bondía Company, Jorge|||0000-0001-7286-3719
[EN] Background: The use of continuous glucose monitoring (CGM) devices in managing type 1 diabetes (T1D) has been associated with improved glycemic control in individuals with T1D. A key challenge for CGMs, however, is achieving accuracy, particularly under conditions where glucose levels may fluctuate rapidly, such as during exercise. Another factor contributing to blood glucose variability is the menstrual cycle, during which hormonal fluctuations affect insulin sensitivity, leading to variable glucose levels. This study aimed to assess the accuracy of FreeStyle Libre-3 (FSL3) during continuous moderate-intensity aerobic exercise (CONT) performed in the follicular and luteal phases of the menstrual cycle in females with T1D.Methods: Participants underwent CONT sessions on a cycle ergometer, one in the follicular phase and one in the luteal phase of the menstrual cycle, at the Research Laboratory of the Faculty of Physiotherapy. Glucose levels were measured every 10 min using FSL3 and the YSI 2500 as a gold standard. Measurements began 20 min before CONT and continued for 20 min after exercise.Results: A total of 26 females (mean age 32.2 +/- 6.1 years and mean duration of diabetes 16.4 +/- 8.4 years) participated in this study. FSL3 showed significant differences compared with YSI glucose data for both phases of the menstrual cycle (about 16 mg/dL higher in FSL3). There were no differences in mean absolute relative differences (MARDs) between the follicular (16.06%) and luteal (16.43) phases. Moreover, exercise did not affect MARDs, which were 14.21% pre-exercise and 17.63% postexercise for the follicular phase and 14.95% pre-exercise and 17.71% postexercise for the luteal phase.Conclusions: The findings suggest that the accuracy of FSL3 is not affected by CONT, showing good accuracy levels in both phases of the menstrual cycle. Thus, this study is the first to examine the influence of the menstrual cycle and exercise on the accuracy of a CGM device.The study was also prospectively registered at clinicaltrials.gov (NCT06086067)., This work received support from grants PID2019-107722RB-C21 and PID2022-137723OB-C21 funded by MCIN/AEI/10.13039/501100011033 and CIBER (Consorcio Centro de Investigacion Biomedica en Red), group number CB17/08/00004, Instituto de Salud Carlos III, Ministerio de Ciencia e Innovacion, and from the European Union-European Regional Development Fund. Cuerda-del Pino is supported by the University Teaching Training Program (FPU) of the Ministry of Science, Innovation and Universities of Spain. Grant number: FPU20/07337.
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

The Impact of Missing Continuous Blood Glucose Samples on Machine Learning Models for Predicting Postprandial Hypoglycemia: An Experimental Analysis

  • Rehman, Najib Ur
  • Contreras, Ivan
  • Beneyto Tantiña, Aleix
  • Vehí, Josep
This study investigates how missing data samples in continuous blood glucose data affect the prediction of postprandial hypoglycemia, which is crucial for diabetes management. We analyzed the impact of missing samples at different times before meals using two datasets: virtual patient data and real patient data. The study uses six commonly used machine learning models under varying conditions of missing samples, including custom and random patterns reflective of device failures and arbitrary data loss, with different levels of data removal before mealtimes. Additionally, the study explored different interpolation techniques to counter the effects of missing data samples. The research shows that missing samples generally reduce the model performance, but random forest is more robust to missing samples. The study concludes that the adverse effects of missing samples can be mitigated by leveraging complementary and informative non-point features. Consequently, our research highlights the importance of strategically handling missing data, selecting appropriate machine learning models, and considering feature types to enhance the performance of postprandial hypoglycemia predictions, thereby improving diabetes management, This work was partially supported by the Spanish Ministry of Science and Innovation: PID2020-117171RA-I00 and PID2022-137723OB-C22; MCIN: MCIN/AEI/10.13039/501100011033; Government of Catalonia: 2017SGR1551—2021 FI_B 00896