Pasar al contenido principal

BUSQUEDA DIRECTA DE MATERIA OSCURA CON LA COLABORACION GLOBAL ARGON DARK MATTER COLLABORATION

PID2022-138357NB-C22

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario CENTRO DE INVESTIGACION ENERGETICA MEDIOAMBIENTAL Y TECNOLOGICA (CIEMAT)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

A new hybrid gadolinium nanoparticles-loaded polymeric material for neutron detection in rare event searches

  • Cebrián, Susana
  • Acerbi, F.
  • Adhikari, P.
  • Agnes, P.
  • Ahmad, I.
  • Albergo, S.
  • Albuquerque, I.F.
  • Alexander, T.
  • Alton, A.K.
  • Amaudruz, P.
  • Angiolilli, M.
  • Aprile, E.
  • Martínez, M.
Experiments aimed at direct searches for WIMP dark matter require highly effective reduction of backgrounds and control of any residual radioactive contamination. In particular, neutrons interacting with atomic nuclei represent an important class of backgrounds due to the expected similarity of a WIMP-nucleon interaction, so that such experiments often feature a dedicated neutron detector surrounding the active target volume. In the context of the development of DarkSide-20k detector at INFN Gran Sasso National Laboratory (LNGS), several R&D projects were conceived and developed for the creation of a new hybrid material rich in both hydrogen and gadolinium nuclei to be employed as an essential element of the neutron detector. Thanks to its very high cross-section for neutron capture, gadolinium is one of the most widely used elements in neutron detectors, while the hydrogen-rich material is instrumental in efficiently moderating the neutrons. In this paper results from one of the R&Ds are presented. In this effort the new hybrid material was obtained as a poly(methyl methacrylate) (PMMA) matrix, loaded with gadolinium oxide in the form of nanoparticles. We describe its realization, including all phases of design, purification, construction, characterization, and determination of mechanical properties of the new material.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The underground argon project: procurement and purification of argon for dark matter searches and beyond

  • Agnes, P.
  • Back, H. O.
  • Bonivento, W.
  • Boulay, M. G.
  • Canci, N.
  • Caravati, M.
  • Cebrian, S.
  • Cocco, V.
  • Diaz Mairena, D.
  • Franco, D.
  • Gabriele, F.
  • Gahan, D.
  • Galbiati, C.
  • Garcia Abia, P.
  • Gendotti, A.
  • Hessel, T.
  • Horikawa, S.
  • Lopez Manzano, R.
  • Luzzi, L.
  • Martinez, M.
  • Pesudo, V.
  • Razeti, M.
  • Renshaw, A. L.
  • Romero, L.
  • Rubbia, A.
  • Santorelli, R.
  • Simeone, M.
  • Stefanizzi, R.
  • Steri, A.
  • Sulis, S.
The existence of dark matter in the universe is inferred from abundant astrophysical and cosmological observations. The Global Argon Dark Matter Collaboration (GADMC) aims to perform the searches for dark matter in the form of weakly interacting massive particles (WIMPs), whose collisions with argon nuclei would produce nuclear recoils with tens of keV energy. Argon has been considered an excellent medium for the direct detection of WIMPs as argon-based scintillation detectors can make use of pulse shape discrimination (PSD) to separate WIMP-induced nuclear recoil signals from electron recoil backgrounds with extremely high efficiency. However, argon-based direct dark matter searches must confront the presence of intrinsic 39Ar as the predominant source of electron recoil backgrounds (it is a beta-emitter with an endpoint energy of 565 keV and half-life of 269 years). Even with PSD, the 39Ar activity in atmospheric argon (AAr), mainly produced and maintained by cosmic ray-induced nuclear reactions, limits the ultimate size of argon-based detectors and restricts their ability to probe very-low-energy events. The discovery of argon from deep underground wells with significantly less 39Ar than that in AAr was an important step in the development of direct dark matter detection experiments using argon as the active target. Thanks to pioneering research and successful R&D, in 2012, the first 160 kg batch of underground argon (UAr) was extracted from a CO2 well in Cortez, Colorado. The DarkSide-50 experiment at the Gran Sasso National Laboratory (LNGS) in Italy, the first liquid argon detector ever operated with a UAr target, demonstrated a ∼ 1,400 suppression of the 39Ar activity with respect to the atmospheric argon. An even larger suppression is expected for 42Ar (another intrinsic beta-emitter with the 42K daughter isotope, also a beta-emitter) as its production is expected mainly in the upper atmosphere. Following the results of DarkSide-50, the GADMC initiated the UAr project for extraction from underground and cryogenic purification of 100 t of argon to be used as a target in the next-generation experiment DarkSide-20k. This paper contains a description of the Urania Plant in Cortez, Colorado, where UAr is extracted; the Aria Plant in Sardinia, Italy, an industrial-scale plant comprising a 350-m state-of-the-art cryogenic isotopic distillation column, designed for further purification of the extracted argon and further reduction of the isotopic abundance of 39Ar; and DArT, a facility for UAr radiopurity qualification at the Canfranc Underground Laboratory (LSC), Spain. Moreover, the high radiopurity of UAr leads to other possible applications, for instance, for those neutrinoless double-beta decay experiments using argon as shielding material or, more generally, for all those activities on argon-based detectors in high-energy physics or nuclear physics, which will be briefly discussed.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Benchmarking the design of the cryogenics system for the underground argon in DarkSide-20k

  • Acerbi, F.
  • Adhikari, P.
  • Agnes, P.
  • Ahmad, I.
  • Albergo, S.
  • Albuquerque, I.F.M.
  • Alexander, T.
  • Alton, A.K.
  • Amaudruz, P.
  • Angiolilli, M.
  • Aprile, E.
  • Ardito, R.
  • Atzori Corona, M.
  • Auty, D.J.
  • Ave, M.
  • Avetisov, I.C.
  • Azzolini, O.
  • Back, H.O.
  • Balmforth, Z.
  • Barrado Olmedo, A.
  • Barrillon, P.
  • Batignani, G.
  • Bhowmick, P.
  • Blua, S.
  • Bocci, V.
  • Bonivento, W.
  • Bottino, B.
  • Boulay, M.G.
  • Buchowicz, A.
  • Bussino, S.
  • Busto, J.
  • Cadeddu, M.
  • Cadoni, M.
  • Calabrese, R.
  • Camillo, V.
  • Caminata, A.
  • Canci, N.
  • Capra, A.
  • Caravati, M.
  • Cárdenas-Montes, M.
  • Cargioli, N.
  • Carlini, M.
  • Castellani, A.
  • Castello, P.
  • Cavalcante, P.
  • Cebrian, S.
  • Cela Ruiz, J.
  • Chashin, S.
  • Chepurnov, A.
  • Cifarelli, L.
  • Cintas, D.
  • Citterio, M.
  • Cleveland, B.
  • Coadou, Y.
  • Cocco, V.
  • Colaiuda, D.
  • Conde Vilda, E.
  • Consiglio, L.
  • Costa, B.S.
  • Czubak, M.
  • D'Aniello, M.
  • D'Auria, S.
  • Da Rocha Rolo, M.D.
  • Darbo, G.
  • Davini, S.
  • De Cecco, S.
  • De Guido, G.
  • Dellacasa, G.
  • Derbin, A.V.
  • Devoto, A.
  • Di Capua, F.
  • Di Ludovico, A.
  • Di Noto, L.
  • Di Stefano, P.
  • Dias, L.K.
  • Díaz Mairena, D.
  • Ding, X.
  • Dionisi, C.
  • Dolganov, G.
  • Dordei, F.
  • Dronik, V.
  • Elersich, A.
  • Ellingwood, E.
  • Erjavec, T.
  • Fernandez Diaz, M.
  • Ficorella, A.
  • Fiorillo, G.
  • Franchini, P.
  • Franco, D.
  • Frandini Gatti, H.
  • Frolov, E.
  • Gabriele, F.
  • Gahan, D.
  • Galbiati, C.
  • Galinski, G.
  • Gallina, G.
  • Gallus, G.
  • Garbini, M.
  • Garcia Abia, P.
  • Gawdzik, A.
  • Gendotti, A.
  • Ghisi, A.
  • Giovanetti, G.K.
  • Goicoechea Casanueva, V.
  • Gola, A.
  • Grandi, L.
  • Grauso, G.
  • Grilli di Cortona, G.
  • Grobov, A.
  • Gromov, M.
  • Guerzoni, M.
  • Gulino, M.
  • Guo, C.
  • Hackett, B.R.
  • Hallin, A.
  • Hamer, A.
  • Haranczyk, M.
  • Harrop, B.
  • Hessel, T.
  • Hill, S.
  • Horikawa, S.
  • Hu, J.
  • Hubaut, F.
  • Hucker, J.
  • Hugues, T.
  • Hungerford, E.V.
  • Ianni, A.
  • Ippolito, V.
  • Jamil, A.
  • Jillings, C.
  • Jois, S.
  • Kachru, P.
  • Keloth, R.
  • Kemmerich, N.
  • Kemp, A.
  • Kendziora, C.L.
  • Kimura, M.
  • Kish, A.
  • Kondo, K.
  • Korga, G.
  • Kotsiopoulou, L.
  • Koulosousas, S.
  • Kubankin, A.
  • Kunzé, P.
  • Kuss, M.
  • Kuzniak, M.
  • Kuzwa, M.
  • La Commara, M.
  • Lai, M.
  • Le Guirriec, E.
  • Leason, E.
  • Leoni, A.
  • Lidey, L.
  • Lissia, M.
  • Luzzi, L.
  • Lychagina, O.
  • Macfadyen, O.
  • Machulin, I.N.
  • Manecki, S.
  • Manthos, I.
  • Mapelli, L.
  • Marasciulli, A.
  • Mari, S.M.
  • Mariani, C.
  • Maricic, J.
  • Martinez, M.
  • Martoff, C.J.
  • Matteucci, G.
  • Mavrokoridis, K.
  • McDonald, A.B.
  • Mclaughlin, J.
  • Merzi, S.
  • Messina, A.
  • Milincic, R.
  • Minutoli, S.
  • Mitra, A.
  • Moharana, A.
  • Moioli, S.
  • Monroe, J.
  • Moretti, E.
  • Morrocchi, M.
  • Mroz, T.
  • Muratova, V.N.
  • Murphy, M.
  • Murra, M.
  • Muscas, C.
  • Musico, P.
  • Nania, R.
  • Nessi, M.
  • Nieradka, G.
  • Nikolopoulos, K.
  • Nikoloudaki, E.
  • Nowak, J.
  • Olchanski, K.
  • Oleinik, A.
  • Oleynikov, V.
  • Organtini, P.
  • Ortiz de Solórzano, A.
  • Pallavicini, M.
  • Pandola, L.
  • Pantic, E.
  • Paoloni, E.
  • Papi, D.
  • Pastuszak, G.
  • Paternoster, G.
  • Peck, A.
  • Pegoraro, P.A.
  • Pelczar, K.
  • Pellegrini, L.A.
  • Perez, R.
  • Perotti, F.
  • Pesudo, V.
  • Piacentini, S.I.
  • Pino, N.
  • Plante, G.
  • Pocar, A.
  • Poehlmann, M.
DarkSide-20k (DS-20k) is a dark matter detection experiment under construction at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It utilises ∼ 100 t of low radioactivity argon from an underground source (UAr) in its inner detector, with half serving as target in a dual-phase time projection chamber (TPC). The UAr cryogenics system must maintain stable thermodynamic conditions throughout the experiment's lifetime of over 10 years. Continuous removal of impurities and radon from the UAr is essential for maximising signal yield and mitigating background. We are developing an efficient and powerful cryogenics system with a gas purification loop with a target circulation rate of 1000 slpm. Central to its design is a condenser operated with liquid nitrogen which is paired with a gas heat exchanger cascade, delivering a combined cooling power of more than 8 kW. Here we present the design choices in view of the DS-20k requirements, in particular the condenser's working principle and the cooling control, and we show test results obtained with a dedicated benchmarking platform at CERN and LNGS. We find that the thermal efficiency of the recirculation loop, defined in terms of nitrogen consumption per argon flow rate, is 95 % and the pressure in the test cryostat can be maintained within ±(0.1–0.2) mbar. We further detail a 5-day cool-down procedure of the test cryostat, maintaining a cooling rate typically within -2 K/h, as required for the DS-20k inner detector. Additionally, we assess the circuit's flow resistance, and the heat transfer capabilities of two heat exchanger geometries for argon phase change, used to provide gas for recirculation. We conclude by discussing how our findings influence the finalisation of the system design, including necessary modifications to meet requirements and ongoing testing activities.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Production, quality assurance and quality control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

  • Acerbi, F.
  • Cebrian, S.
  • Dylon, F.
  • Franco, D.
  • Hidalgo, C.
  • Keloth, R.
  • Leoni, A.
  • Martinez, M.
  • Ortiz de Solórzano, A.
  • Queiroga Bazetto, M.
  • Raffaelli, F.
  • Sabia, M. A.
  • Torres-Lara, S.
  • Unzhakov, E. V.
  • Ventura, P.
  • Wada, M.
  • Yang, C. Zykova, M. P.
The DarkSide-20k dark matter direct detection experiment will employ a 21 m2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. 16 Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Review of neutron yield from (α, n) reactions: data, methods, and prospects

  • Cano-Ott, D
  • Cebrián, S
  • Dimitriou, P
  • Gromov, M
  • Haranczyk, M
  • Kish, A
  • Kluck, H
  • Kudryavtsev, V A
  • Lazanu, I
  • Lozza, V
  • Luzón, G
  • Mendoza, E
  • Parvu, M
  • Pesudo, V
  • Pocar, A
  • Santorelli, R
  • Selvi, M
  • Westerdale, S
  • Zuzel, G
Understanding the radiogenic neutron production rate from the (α, n)reaction is crucial in many areas of physics, including dark mattersearches, neutrino studies, and nuclear astrophysics.In addition to itsrelevance forfundamentalresearch, the (α, n)reaction also plays a significantrole in nuclear energy technologies, for example by contributing to neutron production in subcritical systems using UO2, aswell asin applicationssuch as medical physics. Thisreviewexaminesthe currentstate of(α, n) yield calculations and neutron spectra, describesthe computational tools used fortheir estimation, and discussesthe available cross-section data. We investigate the uncertainties affecting (α, n) yield estimations and propose strategiesto enhance their accuracy. Furthermore,we highlight the need for new measurements of(α, n) cross-sectionsfor a variety ofrelevant materials. Such measurements are key to improving neutron flux predictions and reducing uncertaintiesin sensitivity estimatesfor next-generation physics experiments operating in the keV–MeVrange.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The Darkside-20k Data Acquisition System

  • Acerbi, Fabio
  • Adhikari, Pushparaj
  • Agnes, Paolo
  • Ahmad, Iftikhar
  • Albergo, Sebastiano
  • Albuquerque, Ivone F.M.
  • Alexander, Thomas
  • Alton, Andrew Knight
  • Amaudruz, Pierre-André
  • Anastasi, Gioacchino Alex
  • Angiolilli, Michele
  • Aprile, Elena
  • Auty, David J.
  • Ave Pernas, Maximo
  • Azzolini, Oscar
  • Back, Henning Olling
  • Balmforth, Zoe
  • Barrado Olmedo, Ana Isabel
  • Barrillon, Pierre
  • Batignani, Giovanni
  • Bharat, Swadheen
  • Bhowmick, Pritindra
  • Blua, Sofia
  • Bocci, Valerio
  • Bonivento, Walter
  • Bottino, Bianca
  • Boulay, Mark G.
  • Braun, Titanilla
  • Buchowicz, Andrzej
  • Bussino, Severino
  • Busto, José
  • Cadeddu, Matteo
  • Cadoni, Mariano
  • Calabrese, Roberta
  • Camillo, Vincenzo
  • Caminata, Alessio
  • Capra, Andrea
  • Canci, Nicola
  • Caravati, Mauro
  • Cárdenas-Montes, Miguel
  • Cargioli, Nicola
  • Carlini, Marco
  • Castello, Paolo
  • Cavalcante, Paolo
  • Cebrian, Susana
  • Choudhary, Sarthak
  • Cifarelli, Luisa
  • Coadou, Yann
  • Coarasa, Iván
  • Cocco, Valentina
  • Conde Vilda, Estefania
  • Consiglio, Lucia
  • Coombes, Harrison
  • Ventura Cortez, André Filipe
  • Costa, Barbara S.
  • Czubak, Milena
  • D'Auria, Saverio
  • Da Rocha Rolo, Manuel Dionisio
  • Dainty, Alexander
  • Darbo, Giovanni
  • Davini, Stefano
  • de Asmundis, Riccardo
  • De Cecco, Sandro
  • De Napoli, Marzio
  • Dellacasa, Giulio
  • Di Noto, Lea
  • Di Stefano, Philippe
  • Díaz Mairena, Daniel
  • Dionisi, Carlo
  • Dordei, Francesca
  • Elersich, Aaron
  • Ellingwood, Emma
  • Erjavec, Tyler
  • Fearon, Niamh
  • Fernandez Diaz, Marta
  • Ferro, Luca
  • Ficorella, Andrea
  • Fiorillo, Giuliana
  • Fleming, Dylon
  • Franchini, Paolo
  • Franco, Davide
  • Frandini Gatti, Heriques
  • Gabriele, Federico
  • Gahan, Devidutta
  • Galbiati, Cristiano
  • Galinski, Grzegorz
  • Gallina, Giacomo
  • Garbini, Marco
  • Garcia Abia, Pablo
  • Gawdzik, Andrzej
  • Giovanetti, Graham Kurt
  • Gola, Alberto
  • Grandi, Luca
  • Grauso, Gianfrancesco
  • Grilli di Cortona, Giovanni
  • Guerrero Cánovas, Julián
  • Martínez, María
  • Sarsa, María Luisa
  • Seoane, Carmena,
DarkSide-20k is a Weakly Interacting Massive Particles (WIMPs) search experiment using liquid argon as a target, designed to perform a background-free search for dark matter with unprecedented sensitivity, and is currently under construction at INFN Laboratori Nazionali del Gran Sasso, Italy. The detector comprises a dual-phase Time Projection Chamber (TPC) complemented with external veto systems and is equipped with a total of 2720 Silicon PhotoMultiplier (SiPM)-based readout channels. This work presents the Data Acquisition (DAQ) system designed for DarkSide-20k. The system is capable of continuous, triggerless digitisation of the waveforms with high single-photoelectron detection efficiency and online processing, ensuring data reduction for long-term storage. The DarkSide-20k DAQ system employs commercial CAEN VX2745 digitisers with custom FPGA firmware implementation, identifying pulses in the digitised waveforms. Timing and synchronisation across all 48 digitisers are provided by custom Global and Crate Data Manager boards distributing a phase-aligned clock derived from a disciplined rubidium standard. Waveform segments are processed in real time by Front End Processor machines. Data are organised into collections containing whole detector information and distributed across a farm of Time Slice Processors for event reconstruction, classification, and further reduction before storage and offline analysis. A full “Quadrant” of the system, corresponding to one quarter of the final DAQ, has been assembled and validated at TRIUMF laboratory in Canada. The Quadrant has been stress-tested with simultaneous pulses and demonstrated sustained digitiser readout exceeding expected physics rates and stable long-term performance.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Sensitivity to low-mass WIMPs with an improved liquid argon ionization response model within the DarkSide program

  • Acerbi, F.
  • Adhikari, P.
  • Agnes, P.
  • Ahmad, I.
  • Albergo, S.
  • Albuquerque, I.¿F.
  • Alexander, T.
  • Alton, A.¿K.
  • Amaudruz, P.
  • Bharat, S.
  • Cebrián, S.
  • Coarasa I.
  • Martínez, M.
  • Ortiz de Solórzano, A.
  • Sarsa, M. L.
  • Seoane, C.
Dark matter detection experiments using liquid argon rely on a precise characterization of the ionization response to nuclear recoils, especially in the keV energy range relevant for light dark matter interactions. In this work, we present a comprehensive analysis that combines new measurements from the ReD setup, part of the DarkSide experimental program, with calibration data from DarkSide-50, as well as results from the ARIS and SCENE experiments. These combined datasets enable improved constraints on atomic screening effects in the modeling of the ionization response of liquid argon to nuclear recoils. The analysis is performed within the Thomas-Imel recombination framework adopted in previous DarkSide studies, and is here further constrained by the inclusion of ReD data, which allow the screening function to be determined from calibration measurements. By including the updated ionization model into the DarkSide-50 analysis framework, we obtain stronger exclusion limits on low-mass weakly interacting massive particle (WIMP) interactions, setting new world-leading constraints in the 1–3  GeV/c2 WIMP mass range. Finally, we recast the sensitivity projections for the upcoming DarkSide-20k detector, demonstrating a significantly enhanced discovery potential for low-mass dark matter candidates.