Pasar al contenido principal

EFECTOS DE LA APLICACION DE DIFERENTES CALENTAMIENTOS ESPECIFICOS [PAPE: POSTACTIVATION PERFORMANCE ENHANCEMENT] EN LA RESPUESTA MUSCULAR, FISIOLOGICA Y TECNICA EN NADADORES D

PID2022-142147NB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSIDAD DE GRANADA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 4
Encontrada(s) 1 página(s)

RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Swimming Performance in Elite Triathletes: Comparison Between Open Water and Pool Conditions

  • López-Belmonte, Óscar
  • Ruiz-Navarro, Jesús J.
  • Gay, Ana
  • Cuenca-Fernández, Francisco
  • Arellano, Raúl
  • Cejuela, Roberto
  • Cejuela, Roberto|||/items/effb4561-df37-407b-8573-e9bde0ba5f68
This study aimed to compare performance, kinematic, and physiological variables between open water and pool swimming conditions in elite triathletes and to examine the associations between conditions on these variables. Fourteen elite triathletes (10 males and 4 females [23.4 ± 3.8 years]) performed two 1500-m swimming tests in open water and in a 25-m pool. Swimming speed, stroke rate (SR), length (SL) and index (SI), heart rate (HR), blood lactate concentrations [La−], and end-exercise oxygen uptake (EEV̇O2) were assessed in both conditions. Lower SL and SI and higher SR were obtained in open water compared with pool swimming (p < 0.05). Moreover, kinematic variables changed as a function of distance in both conditions (p < 0.05). No differences were found in the main physiological variables (HR, [La−], and EEV̇O2) between conditions. Respiratory exchange ratio presented lower values in open water than in pool conditions (p < 0.05), while time constant was higher in open water (p = 0.032). The fastest triathletes in open water obtained the best performance in the pool (r = 0.958; p < 0.001). All kinematic variables, HR and peak [La−] presented positive associations between conditions (r > 0.6; p < 0.05). Despite physiological invariance, triathletes and coaches should monitor specific open water training to adapt their swimming technique to the competitive environment.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Open Water Swimming in Elite Triathletes: Physiological and Biomechanical Determinants

  • López-Belmonte, Óscar
  • Gay, Ana
  • Ruiz-Navarro, Jesús J.
  • Cuenca-Fernández, Francisco
  • Cejuela, Roberto
  • Arellano, Raúl
  • Cejuela, Roberto|||/items/effb4561-df37-407b-8573-e9bde0ba5f68
This study aimed (i) to analyze the 1500 m open water swimming performance, (ii) to examine the associations between physiological and biomechanical variables with swimming performance, and (iii) to determine which variables can predict swimming performance in triathletes. Fourteen elite triathletes (23.4±3.8 y) performed a 1500 m test in open water swimming conditions. Swimming performance was assessed using World Aquatics Points Scoring, and data were obtained from the 1500 m open water swimming test. Heart rate, end-exercise oxygen uptake (EE˙VO2) and blood lactate concentrations were measured. The initial 250 m of the 1500 m swimming test presented the highest values of biomechanical variables in males (i. e. swimming speed, stroke rate (SR), length (SL), index (SI)). A decrease in SL was observed in the last 250 m in both sexes. Positive association were found between EE˙VO2 (r=0.513; p=0.030), swimming speed (r=0.873; p<0.001) and SI (r=0.704; p=0.002) with swimming performance. In contrast, time constant of the oxygen uptake (r=−0.500; p=0.034) and buoy-turn times (r=−0.525; p=0.027) were negatively associated with performance. SI was the main predictor (R 2=0.495) of open water swimming performance in triathletes. In conclusion, triathletes and coaches must conduct open water training sessions to maximize SI (i. e. swimming efficiency).
UPCommons. Portal del coneixement obert de la UPC
Publicación Contribución de congreso (ConferenceOutput)

Exploratory validation of temporal and event-based metrics from triton 2 unit in swimmers with and without disability

  • Febles Castro, Adrián
  • Rodríguez Fernández, Antonio|||0000-0002-6272-8326
  • Ruiz Navarro, Jesús Juan
  • Marcé Gil, Jaume
  • Arellano Colomina, Raúl
BACKGROUND: Wearable inertial sensors are increasingly used to monitor swimming performance; however, evidence regarding their validity remains limited and inconsistent, particularly in Para swimmers, whose alterations in coordination, symmetry and propulsion may challenge head- mounted inertial event detection. This study aimed to provide a preliminary evaluation of the validity and agreement of the Triton 2 Unit system (triaxial accelerometer, gyroscope and magnetometer) against video-based analysis in swimmers with and without disabilities. METHODS: Four male and two female competitive swimmers (three without disabilities and three Paralympic swimmers) performed a structured training protocol under controlled conditions. Performance metrics derived from the head-worn inertial sensor were compared with a video-based reference. Variables analysed included lap time, mean stroke rate, number of strokes, underwater time, and turn time. Agreement and accuracy were assessed using median bias, interquartile range (IQR), median absolute percentage error (MdAPE), Lin’s concordance correlation coefficient (¿c), and non-parametric 95% limits of agreement. RESULTS: In swimmers without disabilities, Triton showed high agreement for lap time (¿c = 0.968), stroke rate (¿c = 0.962), and number of strokes (¿c = 0.955), with low relative errors. Moderate agreement was observed for underwater time (¿c = 0.829), while turn time showed poor agreement (¿c = 0.228). In Para swimmers, agreement was generally lower and more variable, with wider limits of agreement across all variables. Lap time (¿c = 0.869) and stroke rate (¿c = 0.822) showed the highest consistency, whereas underwater time, number of strokes, and turn time showed reduced agreement. In one swimmer with severe impairment (S5), the device failed to correctly identify lap structure, leading to invalid outputs. CONCLUSIONS: Triton 2 Unit provides acceptable accuracy for selected metrics in swimmers without disabilities under ecological conditions. In Para swimmers, increased variability and occasional detection failures limit its applicability, particularly for event-based variables and severe impairments., The authors would like to sincerely thank all swimmers and coaches involved in this study for their valuable time, commitment, and collaboration. Their contribution was fundamental to the successful completion of this research. This research was partially supported by the ALECTOR2024 grant from the Universitat Politècnica de Catalunya – BarcelonaTech (UPC) and by the Grant PID2022-142147NB- I00 (SWIM III) funded by MICIU/AEI/10.13039/501100011033/ and by ERDF, EU. AFC holds an FPI fellowship, which is funded through the aforementioned grant., Peer Reviewed
Recercat. Dipósit de la Recerca de Catalunya
Publicación Contribución de congreso (ConferenceOutput)

Exploratory validation of temporal and event-based metrics from triton 2 unit in swimmers with and without disability

  • Febles Castro, Adrián
  • Rodríguez Fernández, Antonio
  • Ruiz Navarro, Jesús Juan
  • Marcé Gil, Jaume
  • Arellano Colomina, Raúl
BACKGROUND: Wearable inertial sensors are increasingly used to monitor swimming performance; however, evidence regarding their validity remains limited and inconsistent, particularly in Para swimmers, whose alterations in coordination, symmetry and propulsion may challenge head- mounted inertial event detection. This study aimed to provide a preliminary evaluation of the validity and agreement of the Triton 2 Unit system (triaxial accelerometer, gyroscope and magnetometer) against video-based analysis in swimmers with and without disabilities. METHODS: Four male and two female competitive swimmers (three without disabilities and three Paralympic swimmers) performed a structured training protocol under controlled conditions. Performance metrics derived from the head-worn inertial sensor were compared with a video-based reference. Variables analysed included lap time, mean stroke rate, number of strokes, underwater time, and turn time. Agreement and accuracy were assessed using median bias, interquartile range (IQR), median absolute percentage error (MdAPE), Lin’s concordance correlation coefficient (¿c), and non-parametric 95% limits of agreement. RESULTS: In swimmers without disabilities, Triton showed high agreement for lap time (¿c = 0.968), stroke rate (¿c = 0.962), and number of strokes (¿c = 0.955), with low relative errors. Moderate agreement was observed for underwater time (¿c = 0.829), while turn time showed poor agreement (¿c = 0.228). In Para swimmers, agreement was generally lower and more variable, with wider limits of agreement across all variables. Lap time (¿c = 0.869) and stroke rate (¿c = 0.822) showed the highest consistency, whereas underwater time, number of strokes, and turn time showed reduced agreement. In one swimmer with severe impairment (S5), the device failed to correctly identify lap structure, leading to invalid outputs. CONCLUSIONS: Triton 2 Unit provides acceptable accuracy for selected metrics in swimmers without disabilities under ecological conditions. In Para swimmers, increased variability and occasional detection failures limit its applicability, particularly for event-based variables and severe impairments., The authors would like to sincerely thank all swimmers and coaches involved in this study for their valuable time, commitment, and collaboration. Their contribution was fundamental to the successful completion of this research. This research was partially supported by the ALECTOR2024 grant from the Universitat Politècnica de Catalunya – BarcelonaTech (UPC) and by the Grant PID2022-142147NB- I00 (SWIM III) funded by MICIU/AEI/10.13039/501100011033/ and by ERDF, EU. AFC holds an FPI fellowship, which is funded through the aforementioned grant., Peer Reviewed, Postprint (published version)