NUEVAS PERSPECTIVAS Y HERRAMIENTAS PARA IDENTIFICAR REGIONES FUNCIONALES CRITICAS DE TEJIDO ARRITMOGENICO MEDIANTE PROCESADO ARRAY DE MAPAS LOCALES EN CATHETER MULTIELECTRODO

PID2022-142514OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para Impulsar la Investigación Científico-Técnica y su Transferencia
Subprograma Subprograma Estatal de Generación de Conocimiento
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2022
Plan Estatal 2021-2023 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 7
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

EGM analyzer: A modular software platform for visualization and analysis of cardiac electrograms

  • Elisa
  • Raúl
  • Castells, Francisco|||0000-0001-5044-3545
  • Millet Roig, José|||0000-0002-8879-003X
  • Ruiperez-Campillo, Samuel
  • Cervigon, Raquel
[EN] Background and Objectives: The analysis of intracardiac electrograms (EGMs) is crucial for understanding the electrophysiological mechanisms underlying cardiac arrhythmias. However, the diversity of mapping systems and data formats poses challenges for data integration, visualization, and the comparison of electrophysiological biomarkers. In this work, we develop a modular and extensible software platform for the visualization, analysis, and comparison of intracardiac electrograms and related biomarkers in both research and clinical contexts. Methods: A custom software tool was developed with an interactive graphical user interface (GUI) capable of loading, processing, and visualizing cardiac mapping data. The platform supports three-dimensional (3D) representations of cardiac geometries and allows users to display multiple biomarkers including peak-to-peak amplitude, local activation times (LATs), ablation points, and other derived metrics. The tool enables the visual ization of unipolar and bipolar electrograms, as well as the computation of omnipolar signals. The open-source software is made available. Results: The platform provides a unified environment for handling heterogeneous electrophysiological data. Users can visualize cardiac geometries, overlay various signal-derived maps, and interactively inspect local elec trograms. The modular design enables the integration of new biomarkers and analytical methods with minimal effort, facilitating both clinical interpretation and research development. Conclusions: This software bridges a key gap in electrophysiological data analysis by enabling consistent visual ization and comparison of intracardiac signals across datasets and biomarkers. Its modular and extensible design supports ongoing research in cardiac electrophysiology and provides clinicians with an intuitive environment for multimodal analysis., This work has been supported by PID2022-142514OB-I00 (National Research Program, Ministerio de Ciencia e Innovacion, Spanish Government) , CIBERCV CB16/11/00486 (Instituto de Salud Carlos III, Spain) and FPU22/02462 (Ministerio de Ciencia e Innovacion, Spanish Government) .
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Vector Field Heterogeneity for the Assessment of Locally Disorganised Cardiac Electrical Propagation Wavefronts From High-Density Multielectrodes

  • Pancorbo, Lucía
  • Ruiperez-Campillo, Samuel
  • Tormos, Álvaro
  • Cervigón, Raquel
  • Alberola, Antonio
  • Chorro, Francisco Javier
  • Guill Ibáñez, Antonio|||0000-0001-8546-264X
  • Millet Roig, José|||0000-0002-8879-003X
  • Castells, Francisco|||0000-0001-5044-3545
[EN] High-density multielectrode catheters are becoming increasingly popular in cardiac electrophysiology for advanced characterisation of the cardiac tissue, due to their potential to identify impaired sites. These are often characterised by abnormal electrical conduction, which may cause locally disorganised propagation wavefronts. To quantify it, a novel heterogeneity parameter based on vector field analysis is proposed, utilising finite differences to measure direction changes between adjacent cliques. The proposed Vector Field Heterogeneity metric has been evaluated on a set of simulations with controlled levels of organisation in vector maps, and a variety of grid sizes. Furthermore, it has been tested on animal experimental models of isolated Langendorff-perfused rabbit hearts. The proposed parameter exhibited superior capturing ability of heterogeneous propagation wavefronts compared to the classical Spatial Inhomogeneity Index, and simulations proved that the metric effectively captures gradual increments in disorganisation in propagation patterns. Notably, it yielded robust and consistent outcomes for $\mathbf {4\times 4}$ grid sizes, underscoring its suitability for the latest generation of orientation-independent cardiac catheters., This work was supported in part by the National Research Program, Ministerio de Ciencia e Innovación, Spanish Government under Grants PID2019- 109547RB-I00 and PID2022-142514OB-I00, and in part by Instituto de Salud Carlos II under Grant CIBERCV CB16/11/00486.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

State of the Art of Artificial Intelligence in Clinical Electrophysiology in 2025: A Scientific Statement of the European Heart Rhythm Association (EHRA) of the ESC, the Heart Rhythm Society (HRS), and the ESC Working Group on E-Cardiology

  • Svennberg, Emma
  • Han, Janet K.
  • Caiani, Enrico G.
  • Engelhardt, Sandy
  • Ernst, Sabine
  • Friedman, Paul
  • Garcia, Rodrigue
  • Ghanbari, Hamid
  • Hindricks, Gerhard
  • Man, Sharon H.
  • Narayan, Sanjiv M.
  • Ng, G. Andre
  • Noseworthy, Peter A.
  • Tjong, Fleur V. Y.
  • Millet Roig, José|||0000-0002-8879-003X
[EN] Aims Artificial intelligence (AI) has the potential to transform cardiac electrophysiology (EP), particularly in arrhythmia detection, procedural optimization, and patient outcome prediction. However, a standardized approach to reporting and understanding AI-related research in EP is lacking. This scientific statement aims to develop and apply a checklist for AI-related research reporting in EP to enhance transparency, reproducibility, and understandability in the field. Methods and results An AI checklist specific to EP was developed with expert input from the writing group and voted on using a modified Delphi process, leading to the development of a 29-item checklist. The checklist was subsequently applied to assess reporting practices to identify areas where improvements could be made and provide an overview of the state of the art in AI-related EP research in three domains from May 2021 until May 2024: atrial fibrillation (AF) management, sudden cardiac death (SCD), and EP lab applications. The EHRA AI checklist was applied to 31 studies in AF management, 18 studies in SCD, and 6 studies in EP lab applications. Results differed between the different domains, but in no domain reporting of a specific item exceeded 55% of included papers. Key areas such as trial registration, participant details, data handling, and training performance were underreported (<20%). The checklist application highlighted areas where reporting practices could be improved to promote clearer, more comprehensive AI research in EP. Conclusion The EHRA AI checklist provides a structured framework for reporting AI research in EP. Its use can improve understanding but also enhance the reproducibility and transparency of AI studies, fostering more robust and reliable integration of AI into clinical EP practice.; [GRAPHICS]; ., E.S. is supported by the Stockholm County Council (Clinical researcher appointment), the Swedish Research Council (DNR 2022-01466), the Swedish Heart and Lung foundation, CIMED, S.E. is supported by research grants from German Center for Cardiovascular Research (DZHK), the Carl-Zeiss Foundation in the project Multi-dimension AI. J Millet (e-cardiology) reports grant support PID2022-142514OB-I00 from Spanish Research Agency. Professor GA Ng reports grant support from the British Heart Foundation [Research Excellence Award (RE/24/13003) and Healthcare Innovation Fund (HI/C2/24/360038)], the National Institute for Health and Care Research Invention for Innovation Award (NIHR204553). F.V.Y.T. is supported by personal research grants from the Dutch Research Council (NWO), Amsterdam Cardiovascular Sciences, and Health Holland. J.R. acknowledges funding from the European Union-NextGenerationEU, fellowship RYC2021-031413-I from MCIN/AEI/10.13039/501100011033, and from the European Union "NextGenerationEU/PRTR" and from grants PID2021-128972OA-I00, CNS2023-143599 and PID2023-148975OB-I00, funded by MCIN/AEI/10.13039/501100011033. N.T. (HRS) is supported by NIH grants R01HL166759 and R01HL174440 and a grant from the Leducq Foundation.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

The art of selecting the ECG input in neural networks to classify heart diseases: a dual focus on maximizing information and reducing redundancy

  • Elisa
  • Castells, Francisco|||0000-0001-5044-3545
  • Millet Roig, José|||0000-0002-8879-003X
  • Ruiperez-Campillo, Samuel
  • Casado-Arroyo, Rubén
  • Merino, José Luis
  • Vogt, Julia E.
[EN] Background and Objectives Accurate diagnosis of cardiovascular diseases often relies on the electrocardiogram (ECG). Since the cardiac vector is located within a three-dimensional space and the standard ECG comprises 12 projections or leads derived from it, redundant information is inherently present. This study aims to quantify this redundancy and its impact on classification tasks using Convolutional Neural Networks (CNNs) in cardiovascular diseases.Methods We employed signal theory and mutual information to introduce a novel redundancy metric and explored techniques for redundancy augmentation and reduction. This involved lead selection and transformation to evaluate the effects on neural network performance.Results Our findings indicate that optimizing input configurations through redundancy reduction techniques can enhance the performance of deep learning models in cardiovascular diagnostics, provided that the information is preserved and minimally distorted.Conclusion For the first time, this research has quantified the redundancy present in the input by validating various redundancy reduction techniques using a CNN. This discovery paves the way for advancing biomedical signal processing research, simplifying model complexity, and enhancing diagnostic performance in cardiovascular medicine within reduced lead systems, such as Holter monitors or wearables., The author(s) declare that financial support was received for the research, authorship, and/or publication of this article. This work has been supported by PID 2022-142514OB-I00 (National Research Program, Ministerio de Ciencia e Innovacion, Spanish Government) and CIBERCV CB16/11/00486 (Instituto de Salud Carlos III).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Novel synchronization method for vectorcardiogram reconstruction from ECG printouts: A comprehensive validation approach

  • Elisa
  • Castells, Francisco|||0000-0001-5044-3545
  • Millet Roig, José|||0000-0002-8879-003X
  • Ruiperez-Campillo, Samuel
  • Casado-Arroyo, Rubén
[EN] Background and Objectives: The extensive collection of electrocardiogram (ECG) recordings stored in paper format has provided opportunities for numerous digitization studies. However, the traditional 10 s 12-lead ECG printout typically splits the ECG signals into four asynchronous sections of 3 leads and 2.5 s each. Since each lead corresponds to different time instants, developing a synchronization method becomes necessary for applications such as vectorcardiogram (VCG) reconstruction. Methods: A beat-level synchronization method has been developed and validated using a dataset of 21,674 signals. This method effectively addresses synchronization distortions caused by RR interval variations and preserves the time lags between R peaks across different leads for each beat. Results: The results demonstrate that the proposed method successfully synchronizes the ECG, allowing a VCG reconstruction with an average Pearson Correlation Coefficient of 0.9815±0.0426. The Normalized Root Mean Squared Error (NRMSE) and Mean Absolute Error (MAE) values for the reconstructed VCG are 0.0248±0.0214 mV and 0.0133±0.0123 mV, respectively. These metrics indicate the reliability of the VCG reconstruction achieved by means of the proposed synchronization method. Conclusions: The synchronization method has demonstrated its robustness and high performance compared to existing techniques in the field. Its effectiveness has been observed across a wide variety of signals, showcasing its applicability in real clinical environments. Moreover, its ability to handle a large number of signals makes it suitable for various applications, including retrospective studies and the development of machine learning methods., This work has been supported by PID2022-142514OB-I00 (National Research Program, Ministerio de Ciencia e Innovación, Spanish Government) and CIBERCV CB16/11/00486 (Instituto de Salud Carlos III,Spain).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Vector field heterogeneity as a novel omnipolar mapping metric for functional substrate characterization in scar-related ventricular tachycardias

  • Tonko, Johanna
  • Ruiperez-Campillo, Samuel
  • Cabero-Vidal, Gema
  • Cabrera, Eva
  • Roney, Caroline
  • Lambiase, Pier
  • Saiz, Juan Ángel
  • Millet Roig, José|||0000-0002-8879-003X
  • Castells, Francisco|||0000-0001-5044-3545
[EN] BACKGROUND Vector field heterogeneity (VFH) is a novel omnipolar metric to quantify local propagation heterogeneities that may identify functionally critical sites for ablation in scar-related ventricular tachycardia (VT). OBJECTIVE This study aims to assess the diagnostic value of VFH to identify abnormal propagation patterns during ventricular substrate mapping and compare VFH in VT isthmus sites (IS), low-voltage bystander area (LVA) , and normal voltage areas (NVAa). METHODS Substrate maps acquired with a 16-pole grid catheter in patients with scar-related VT were segmented into sites corresponding to IS, LVA, and NVA (defined as omnipolar voltages > and <1.5 mV) based on corresponding VT activation maps. For each 4 ! 4 electrode-array acquisition, omnipolar-derived vector maps of the directions of electrical propagation were computed offline, and a VFH value per clique ranging from 0 (perfect planar wave) to 1 (maximal disorganization) derived. RESULTS Sixteen patients were studied (56.3% ischemic), evaluating 9 endocardial and 7 epicardial substrate maps. VFH metric at IS was 0.57 6 0.26, LVA 0.52 6 0.34, and NVA 0.16 6 0.24. VFH at IS was higher (more disorganized) than at LVA (P < .001). VFH in NVA was significantly lower (ie, more homogeneous) compared with IS and LVA (P < .001, respectively). Within the isthmus, highest heterogeneity was recorded at entry (0.61 6 0.24), lowest at exit sites (0.44 6 0.27). CONCLUSION VFH mapping identified a significant increase in electrical heterogeneity at IS compared with bystanders with highest heterogeneity at the entrance. Yet, absolute differences were small, and substantial overlap among sites was recorded, precluding its use as a stand-alone mapping approach. VFH may be integrated in existing mapping strategies as complementary information to support identification of ablation targets., Dr Lambiase has received support from UCL/UCLH Biomedicine NIHR, and the British Heart Foundation. Dr Tonko has received research-fellowship support from Bart s Charity London, UK (Grant Nr G-002669). Dr Millet has received support from the National Research Program, Ministerio de Ciencia e Innovación, Spanish Government Grants PID2022-142514OB-I00, Instituto de Salud Carlos III Grant CIBERCV CB16/11/00486.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Ultra-high resolution for accurate analysis in cardiac mapping: a path towards fulfillment of assumptions in omnipolar technology

  • Elisa
  • Raúl
  • Millet Roig, José|||0000-0002-8879-003X
  • Tonko, Johanna
  • Ruiperez-Campillo, Samuel
  • Gsell, Matthias A.F.
  • Plank, Gernot
  • Lambiase, Pier
  • Castells, Francisco
[EN] Omnipolar technology has improved the characterisation of complex arrhythmias by enabling more accurate, direction-independent electrogram analysis. Omnipolar EGMs are reconstructed assuming locally planar and homogeneous propagation. However, anatomical complexity, electrode spacing, tissue heterogeneity, or poor catheter contact may violate this assumption. This study aims to quantify the extent to which key assumptions are fulfilled in clinical settings by analysing amplitude and morphology variability, as well as wavefront non-planarity. Additionally, we evaluate how such deviations affect the accuracy of omnipolar EGM reconstruction and propagation direction estimation. To en hance performance, we introduce the concept of Ultra-High Resolution-defined as the resolution required to meet these assumptions-and propose electrical field interpolation as a method to bridge this target with feasible interelectrode spacing in practical devices. Results are validated using in silico simulations and clinical recordings acquired with the Advisor TMHD Grid Mapping Catheter. The results show that at 4 mm interelectrode spacing-common in current catheters-deviations from the underlying assumptions are frequent, leading to inaccurate omnipolar signal computation and derived parame ters. The proposed Ultra-High Resolution proves reliable, as evidenced by low normalised root mean square error and high Pearson correlation of the interpolated unipolar signals. By effectively reducing interelectrode spacing through interpolation, compliance with the underlying assumptions improves significantly. Accurate omnipolar mapping requires tighter interelectrode spacing than current catheters provide. We show that interpolation reliably enhances spatial resolution, enabling assumption compliance without hard ware changes. A spacing of 0.5 mm defines Ultra-High Resolution, beyond which further gains are negligible. We establish a practical benchmark for future catheter design and signal processing., This work has been supported by PID2022-142514OB-I00 (National Research Program, Ministerio de Ciencia e Innovación, Spanish Government), CIBERCV CB16/11/00486 (Instituto de Salud Carlos III, Spain) and FPU22/02462 (Ministerio de Ciencia e Innovación, Spanish Government).