Pasar al contenido principal

VULNICONTROL-2: DIAGNOSTICO AVANZADO Y ESTRATEGIAS DE CONTROL DEL PATOGENO VIBRIO VULNIFICUS EN ACUICULTURA SOSTENIBLE

PID2024-162627OB-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal para la Investigación y el Desarrollo Experimental
Subprograma Subprograma Estatal de Generación de Conocimiento Científico-Técnico y Desarrollo Experimental
Convocatoria Proyectos de I+D+i (Generación de Conocimiento y Retos Investigación)
Año convocatoria 2024
Plan Estatal 2024-2027 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 1
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

A Fluorogenic Biosensor for Direct Detection of Vibrio vulnificus, a Climate Change Biomarker

  • Aranda-Sobrino, María Nieves
  • Carmona-Salido, Héctor
  • Sanjuán, Eva
  • Amaro, Carmen
  • Caballos-Gómez, María Isabel
  • López-Palacios, Alba|||0000-0002-4397-277X
  • Aznar, Elena|||0000-0003-0361-3876
  • Martínez-Máñez, Ramón|||0000-0001-5873-9674
  • Hernández-Montoto, Andy|||0000-0001-5623-9836
[EN] Vibrio vulnificus, a marine pathogen and climate change biomarker, poses serious risks to human and animal health through seafood consumption and seawater exposure. Rapid detection methods are urgently needed for both vibriosis diagnosis and surveillance in warming coastal waters. We report a fluorogenic biosensor based on nanoporous anodic alumina loaded with rhodamine B and capped with an oligonucleotide probe targeting a unique sequence of the vvhA cytolysin gene, specific to V. vulnificus. In the presence of the target DNA, the probe is displaced, pores open, and the fluorophore is released, generating a measurable signal. The biosensor exhibited high sensitivity and selectivity across diverse matrices, including fish mucus and serum, human serum, sterilized brackish water, and-critically-unprocessed natural lake and seawater samples, without DNA extraction or amplification. Detection limits ranged between 10 & sup2; and 5 & times; 10 & sup2; CFU mL(-)& sup1;, comparable in sensitivity to state-of-the-art qPCR assays. The biosensor outperformed conventional approaches in speed, simplicity, and cost-effectiveness, while maintaining accuracy. These findings underscore the potential of this platform for integrated One Health applications, bridging environmental monitoring with rapid diagnosis of vibriosis in humans and animals.Preliminary results from this study were previously made available as a preprint in SSRN (DOI: https://ssrn.com/abstract=5032822)., Ministerio de Ciencia, Innovación y Universidades (MICIU) and the Agencia Estatal de Investigación (AEI/10.13039/501100011033), with co‐ funding from the European Regional Development Fund (ERDF), European Union, Grant/Award Numbers: PID2020‐120619RB‐I00, PID2024‐162627OB‐I00, PID2021‐126304OB‐C41, PID2024‐155683OB‐C41; Generalitat Valenciana (Spain), Grant/Award Numbers: CIAICO/2021/293, CIAICO/2024/236; Spanish Ministry of Science and Innovation (MCIN) with funding from the European Union European Union NextGenerationEU (PRTR‐C17.I1) and the Generalitat Valenciana (GVA‐THINKINAZUL/2021/027; Principal Investigators: Carmen Amaro and B. Fouz, Universitat de València); Instituto de Salud Carlos III, Grant/Award Number: CIBER ConsorcioCentrodeInvestigaciónBiomédicaenRed(CB06/01/2012)