Design optimization for the measurement accuracy improvement of a large range nanopositioning stage

  • Torralba Gracia, Marta
  • Yagüe Fabra, José Antonio
  • Albajez García, José Antonio
  • Aguilar Martín, Juan José
Both an accurate machine design and an adequate metrology loop definition are critical factors when precision positioning represents a key issue for the final system performance. This article discusses the error budget methodology as an advantageous technique to improve the measurement accuracy of a 2D-long range stage during its design phase. The nanopositioning platform NanoPla is here presented. Its specifications, e.g., XY-travel range of 50 mm ˆ 50 mm and sub-micrometric accuracy; and some novel designed solutions, e.g., a three-layer and two-stage architecture are described. Once defined the prototype, an error analysis is performed to propose improvement design features. Then, the metrology loop of the system is mathematically modelled to define the propagation of the different sources. Several simplifications and design hypothesis are justified and validated, including the assumption of rigid body behavior, which is demonstrated after a finite element analysis verification. The different error sources and their estimated contributions are enumerated in order to conclude with the final error values obtained from the error budget. The measurement deviations obtained demonstrate the important influence of the working environmental conditions, the flatness error of the plane mirror reflectors and the accurate manufacture and assembly of the components forming the metrological loop. Thus, a temperature control of ¿0.1 ¿C results in an acceptable maximum positioning error for the developed NanoPla stage, i.e., 41 nm, 36 nm and 48 nm in X-, Y- and Z-axis, respectively.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Large range nanopositioning stage design: A three-layer and two-stage platform

  • Torralba, M.
  • Valenzuela , M.
  • Yagüe-Fabra, J. A.
  • Albajez, J. A.
  • Aguilar, J. J.
In this article, a novel two-dimensional nanopositioning platform (NanoPla) design is described. Its requirements are not only sub-micrometer accuracy for nanotechnology applications, but also long working range (XY-motion 50 mm × 50 mm). These features increase the common range operation of devices for nanotechnology issues (e.g. an atomic force microscope), and the number of potential metrological applications: positioning for manufacturing, manipulation or sample characterization. This novel design is characterized by a three-layer architecture and a two-stage motion strategy, which minimizes the measurement error. The manufactured prototype is here justified considering precision engineering principles and a wide state-of-art study of the literature, regarding long range nanopositioning stages. The simulations, the experimental results and the error budget also allowed, first, the optimization and, secondly, the validation of the design at nanometer scale.