Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 6
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms

  • Alcaraz, Raúl
  • Hornero, Fernando
  • Rieta, J J|||0000-0002-3364-6380
The standard electrocardiogram (ECG) is the most common non-invasive way to study atrial fibrillation (AF). In this respect, previous works have shown that the surface lead V 1 reflects mainly the dominant atrial frequency (DAF) of the right atrium (RA), which has been widely used to study AF. In a similar way, AF organization and fibrillatory (f) wave amplitude are two recently proposed non-invasive AF markers. These markers need to be validated with invasive recordings in order to assess their capability to reliably reflect the internal fibrillatory activity dynamics. In this work, these two non-invasive metrics have been compared with similar measures recorded from two unipolar atrial electrograms (AEGs). For both ECG and AEG signals, AF organization has been computed by applying a nonlinear regularity index, such as sample entropy (SampEn), to the atrial activity (AA) and to its fundamental waveform, defined as the main atrial wave (MAW). The surface and epicardial f wave amplitude has been estimated through their mean power. Results obtained for 38 patients showed statistically significant correlations between the values measured from surface and invasive recordings, thus corroborating the usefulness of the aforesaid markers in the non-invasive study of AF. Precisely, for AF organization computed from the MAW, the correlation coefficients between surface and both AEGs were R = 0.926 (p < 0.001) and R = 0.932 (p < 0.001). For f wave amplitude, slightly lower significant relationships were noticed, the correlation coefficients being R = 0.765 (p < 0.001) and R = 0.842 (p < 0.001). These outcomes together with interesting linear relationships found among the parameters suggest that AF regularity estimated via SampEn and f wave amplitude can non-invasively characterize the epicardial activity related to AF. © 2011 Institute of Physics and Engineering in Medicine., This work was supported by projects TEC2007-64884 and TEC2010-20633 from the Spanish Ministry of Science and Innovation, PII2C09-0224-5983, PPII11-0194-8121 and PII1C09-0036-3237 from Junta de Comunidades de Castilla La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Surface ECG organization time course analysis along onward episodes of paroxysmal atrial fibrillation

  • Alcaraz, Raul
  • Hornero, Fernando
  • Rieta, J J|||0000-0002-3364-6380
The complete understanding of the mechanisms leading to the initiation, maintenance and self-termination of atrial fibrillation (AF) still is an unsolved challenge for cardiac electrophysiology. Studies in which AF has been induced have shown that electrophysiological and structural remodeling of the atria during the arrhythmia could play an important role in the transition from paroxysmal to persistent AF. However, to this day, the time course of the atrial remodeling along onward episodes of non-induced paroxysmal AF has not been investigated yet. In this work, a non-invasive method, based on the regularity estimation of AF through sample entropy (SampEn), has been used to assess the organization evolution along onward episodes of paroxysmal AF. Given that AF organization has been associated to the number of existing wavelets wandering throughout the atrial tissue, SampEn could be considered as a concomitant estimator of atrial remodeling. The achieved results, in close agreement with previous findings obtained from invasive recordings, proved several relevant aspects of arial remodeling. Firstly, a progressive disorganization increase (SampEn increase) along onward episodes of AF has been observed for 63% of the analyzed patients, whereas a stable AF organization degree has been appreciated in the remaining 37%. Next, a positive correlation between episode duration and SampEn has been obtained (R = 0.541, p< 0.01). Finally, a remarkable influence of the fibrillation-free interval, preceding each episode, on the corresponding level of AF organization at the onset of the subsequent AF episode has been observed, with a correlation between these two indices of R = 0.389 (p< 0.01). As a consequence, it could be considered that atrial electrophysiological dynamics that occur along onward paroxysmal AF episodes are reflected and can be quantified from ECG recordings through non-invasive organization estimation. © 2010 IPEM., This work was supported by the projects TEC2010-20633 from the Spanish Ministry of Science and Innovation, PII2C09-0224-5983 and PPII11-0194-8121 from Junta de Comunidades de Castilla La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Classification of paroxysmal and persistent atrial fibrillation in ambulatory ECG recordings

  • Alcaraz, Raúl
  • Sandberg, Frida
  • Sornmo, Leif
  • Rieta, J J|||0000-0002-3364-6380
The problem of classifying short atrial fibrillatory segments in ambulatory ECG recordings as being either paroxysmal or persistent is addressed by investigating a robust approach to signal characterization. The method comprises preprocessing estimation of the dominant atrial frequency for the purpose of controlling the subbands of a filter bank, computation of the relative subband (harmonics) energy, and the subband sample entropy. Using minimum-error-rate classification of different feature vectors, a data set consisting of 24-h ambulatory recordings from 50 subjects with either paroxysmal (26) or persistent (24) atrial fibrillation (AF) was analyzed on a 10-s segment basis; a total of 212,196 segments were classified. The best performance in terms of area under the receiver operating characteristic curve was obtained for a feature vector defined by the subband sample entropy of the dominant atrial frequency and the relative harmonics energy, resulting in a value of 0.923, whereas that of the dominant atrial frequency was equal to 0.826. It is concluded that paroxysmal and persistent AFs can be discriminated from short segments with good accuracy at any time of an ambulatory recording. © 2006 IEEE., January 11, 2011; accepted January 22, 2011. Date of publication February 10, 2011; date of current version April 20, 2011. This work was supported in part by the Spanish Ministry of Science and Innovation under Project TEC2010-20633 and the Junta de Comunidades de Castilla La Mancha under Project PII2C09-0224-5983, Project PII1C09-0036-3237, and Project PPII11-0194-8121. Asterisk indicates corresponding author.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Application of artificial neural networks for versatile preprocessing of electrocardiogram recordings

  • Mateo, Jorge
  • Rieta, J J|||0000-0002-3364-6380
[EN] The electrocardiogram (ECG) is the most widely used method for diagnosis of heart diseases, where a good quality of recordings allows the proper interpretation and identification of physiological and pathological phenomena. However, ECG recordings often have interference from noises including thermal, muscle, baseline and powerline noises. These signals severely limit ECG recording utility and, hence, have to be removed. To deal with this problem, the present paper proposes an artificial neural network (ANN) as a filter to remove all kinds of noise in just one step. The method is based on a growing ANN which optimizes both the number of nodes in the hidden layer and the coefficient matrices, which are optimized by means of the Widrow-Hoff delta algorithm. The ANN has been trained with a database comprising all kinds of noise, both from synthesized and real ECG recordings, in order to handle any noise signal present in the ECG. The proposed system improves results yielded by conventional techniques of ECG filtering, such as FIR-based systems, adaptive filtering and wavelet filtering. Therefore, the algorithm could serve as an effective framework to substantially reduce noise in ECG recordings. In addition, the resulting ECG signal distortion is notably more reduced in comparison with conventional methodologies. In summary, the current contribution introduces a new method which is able to suppress all ECG interference signals in only one step with low ECG distortion and a high noise reduction., This work was partly sponsored by Universidad de Castilla-La Mancha, Patronato Universitario Cardenal Gil de Albornoz from Cuenca, the project TEC2010–20633 from the Spanish Ministry of Science and Innovation and PII2C09–0224–5983 and PII1C09–0036–3237 from Junta de Comunidades de Castilla La Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Radial basis function neural networks applied to efficient QRST cancellation in atrial fibrillation

  • Mateo, Jorge
  • Rieta, J J|||0000-0002-3364-6380
The most extended noninvasive technique for medical diagnosis and analysis of atrial fibrillation (AF) relies on the surface elctrocardiogram (ECG). In order to take optimal profit of the ECG in the study of AF, it is mandatory to separate the atrial activity (AA) from other cardioelectric signals. Traditionally, template matching and subtraction (TMS) has been the most widely used technique for single-lead ECGs, whereas multi-lead ECGs have been addressed through statistical signal processing techniques, like independent component analysis. In this contribution, a new QRST cancellation method based on a radial basis function (RBF) neural network is proposed. The system is able to provide efficient QRST cancellation and can be applied both to single and multi-lead ECG recordings. The learning algorithm used for training the RBF makes use of a special class of network, known as cosine RBF, by updating selected adjustable parameters to minimize the class-conditional variances at the outputs of the network. The experiments verify that RBFs trained by the proposed learning algorithm are capable of reducing the QRST complex dramatically, a property that is not shared by other methods and conventional feed-forward neural networks. Average Results (mean +/- std) for the RBF method in cross-correlation (CC) between original and estimated AA are CC = 0.95 +/- 0.038 being the mean square error (MSE) for the same signals, MSE = 0.311 +/- 0.078. Regarding spectral parameters, the dominant amplitude (DA) and the mean power spectral (MP) were DA = 1.15 +/- 0.18 and MP = 0.31 +/- 0.07, respectively. In contrast, traditional TMS-based methods yielded, for the best case, CC = 0.864 +/- 0.041, MSE = 0.577 +/- 0.097, DA = 0.84 +/- 0.25 and MP = 0.24 +/- 0.07. The results prove that the RBF based method is able to obtain a remarkable reduction of ventricular activity and a very accurate preservation of the AA, thus providing high quality dissociation between atrial and ventricular activities in AF recordings. (C) 2012 Elsevier Ltd. All rights reserved., This work has been supported by the projects TEC2010-20633 from the Spanish Ministry of Science and Innovation, PII1C09-0036-3237 and PII2C09-0224-5983 from Junta de Comunidades de Castilla la Mancha.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Noninvasive time and frequency predictors of long-standing atrial fibrillation early recurrence after electrical cardioversion

  • Alcaraz, Raúl
  • Hornero, Fernando
  • Rieta, J J|||0000-0002-3364-6380
Background: Several clinical factors have been studied to predict atrial fibrillation (AF) recurrence after electrical cardioversion (ECV) with limited predictive value. Methods: A method able to predict robustly long-standing AF early recurrence by characterizing noninvasively the electrical atrial activity (AA) with parameters related to its time course and spectral features is presented. To this respect, 63 patients (20 men and 43 women; mean age 73.4 ± 9.0 years; under antiarrhythmic drug treatment with amiodarone) who were referred for ECV of persistent AF were studied. During a 4-week follow-up, AF recurrence was observed in 41 patients (65.1%). Results: RR variability and the studied AA spectral features, including dominant atrial frequency (DAF), its first harmonic and their amplitude, provided poor statistical differences between groups. On the contrary, f waves power (fWP) and Sample Entropy (SampEn) of the AA behaved as very good predictors. Patients who relapsed to AF presented lower fWP (0.036 ± 0.019 vs 0.081 ± 0.029 n.u. 2, P < 0.001) and higher SampEn (0.107 ± 0.022 vs 0.086 ± 0.033, P < 0.01). Furthermore, fWP presented the highest predictive accuracy of 82.5%, whereas SampEn provided a 79.4%. The remaining features revealed accuracies lower than 70%. A stepwise discriminant analysis (SDA) provided a model based on fWP and SampEn with 90.5% of accuracy. Conclusions: The fWP has proved to predict long-standing AF early recurrence after ECV and can be combined with SampEn to improve its diagnostic ability. Furthermore, a thorough analysis of the results allowed outlining possible associations between these two features and the concomitant status of atrial remodeling., This work was supported by the projects TEC2010-20633 from the Spanish Ministry of Science and Innovation and PII2C09-0224-5983 and PPII11-0194-8121 from Junta de Comunidades de Castilla-La Mancha.