Pasar al contenido principal

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

The challenges of solar hybrid PVT systems in the food processing industry

  • Herrando, María
  • Simón Allué, Raquel
  • Guedea, Isabel
  • Fueyo, Norberto
14 figures, 3 tables., This paper assesses the challenges of alternative solar systems based on hybrid PVT collectors coupled with an absorption chiller (AbCH, single-stage NH3-H2O) in the food-processing industry, from the technical, economic and environmental points of view. This type of industry is usually characterised by a constant cooling demand throughout the year, hot water demand for production processes and electricity consumption for factory equipment and lighting. To the authors¿ knowledge, this work constitutes one of the first studies to address the integration of PVT-water collectors with a single-stage NH3-H2O AbCH for industrial applications. Two alternative PVT-water collectors are analysed, covered and uncovered. A biomass boiler is proposed as an auxiliary heater. To compare the proposed solar solutions, a vegetable and fruit processing and canning factory is considered as a representative case study. Hourly transient simulations considering the real factory demands and real weather data are performed over a year. Two main challenges are found for the solar systems based on the covered PVT collectors, an AbCH and a biomass boiler: the overlapping of the cooling and hot water demands of the food-processing industry, and the high hot water temperatures required. If, alternatively, the current electrical chillers are retained, the system based on uncovered PVT collectors has a reasonable-to-attractive payback time (14.3 years). When the potential environmental benefit is quantified (through carbon pricing), all the proposed solar systems become economically attractive, i.e., with positive total cost savings at the end of the system lifetime. Still, the high cost of PVT collectors, along with the considerably lower price of fuels compared to electricity, hinder the potential of systems that displace fossil fuels., This work was undertaken in the framework of 3GSol, a project funded under the Retos-Colaboración 2017 Programme, National R&D and Innovation Plan, by the Spanish Government, Ministry of Science, Innovation and Universities and co-funded by the EU, through the European Regional Development Fund (ERDF) [grant number RTC-2017-6026-3]., Peer reviewed
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

The challenges of solar hybrid PVT systems in the food processing industry

  • Herrando, M.
  • Simón, R.
  • Guedea, I.
  • Fueyo, N.
This paper assesses the challenges of alternative solar systems based on hybrid PVT collectors coupled with an absorption chiller (AbCH, single-stage NH3-H2O) in the food-processing industry, from the technical, economic and environmental points of view. This type of industry is usually characterised by a constant cooling demand throughout the year, hot water demand for production processes and electricity consumption for factory equipment and lighting. To the authors’ knowledge, this work constitutes one of the first studies to address the integration of PVT-water collectors with a single-stage NH3-H2O AbCH for industrial applications. Two alternative PVT-water collectors are analysed, covered and uncovered. A biomass boiler is proposed as an auxiliary heater. To compare the proposed solar solutions, a vegetable and fruit processing and canning factory is considered as a representative case study. Hourly transient simulations considering the real factory demands and real weather data are performed over a year. Two main challenges are found for the solar systems based on the covered PVT collectors, an AbCH and a biomass boiler: the overlapping of the cooling and hot water demands of the food-processing industry, and the high hot water temperatures required. If, alternatively, the current electrical chillers are retained, the system based on uncovered PVT collectors has a reasonable-to-attractive payback time (14.3 years). When the potential environmental benefit is quantified (through carbon pricing), all the proposed solar systems become economically attractive, i.e., with positive total cost savings at the end of the system lifetime. Still, the high cost of PVT collectors, along with the considerably lower price of fuels compared to electricity, hinder the potential of systems that displace fossil fuels.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Experimental validation of a solar system based on hybrid photovoltaic-thermal collectors and a reversible heat pump for the energy provision in non-residential buildings

  • Herrando, M.
  • Coca-Ortegón, A.
  • Guedea, I.
  • Fueyo, N.
This work aims to validate a transient model of a solar hybrid pilot plant based on photovoltaic-thermal (PV-T) collectors integrated via thermal storage tanks with an air-to-water reversible heat pump (rev-HP). The pilot plant is in operation and provides space heating, cooling, domestic hot water (DHW) and electricity to an industrial building located in Zaragoza (Spain). The plant consists of eight uncovered PV-T collectors (2.6 kWe, 13.6 m2), two water tanks and a rev-HP with a nominal thermal power of 16 kW for heating and 10.5 kW for cooling. The validation results show that the transient model fits the experimental performance of the PV-T collectors, with an average error of -16% and 3%, for the thermal and electrical generation respectively. The accuracy of the estimated rev-HP performance depends on the operation mode. The estimated COP in cooling mode has an average error of 14%, while in heating mode has an average error of -10%. The results show that the integration of the thermal and electrical generation of the PV-T collectors with a high-performance rev-HP allows the solar PV-T system to be self-sufficient to satisfy the building energy demand.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Numerical analysis of the fluid flow and heat transfer of a hybrid PV-thermal collector and performance assessment

  • Herrando, María
  • Fantoni, Guillermo
  • Cubero, Ana
  • Simón-Allué, Raquel
  • Guedea, Isabel
  • Fueyo, Norberto
In recent years, new materials and absorber configurations have been proposed to improve the performance of hybrid photovoltaic-thermal (PV-T) collectors. This work analyses the fluid flow and the energy performance of an uncovered water-based PV-T collector with a roll-bond thermal absorber. A detailed CFD model was developed and the results were compared with the experimental performance features provided by the PV-T manufacturer. The fluid flow results show uneven flow distribution among the roll-bond microchannels which leads to areas with larger PV cell temperatures and thus a lower electricity generation. The PV-T collector layers were also modelled using the energy transfer equations layer-by-layer. The model was run for several water inlet temperatures and water flow-rates to obtain the thermal performance curve. The results show that the electrical efficiency of the PV-T collector is 14.5–10.3% larger than for a PV-only system for water inlet temperatures of 20–30 °C, respectively. The developed CFD model reproduces accurately the thermal performance of the PV-T collector, with a maximum error of 6.5% for inlet water temperatures of 20–60 °C. Therefore, this model can be used with confidence to propose alternative designs that achieve a homogeneous temperature distribution in the PV layer and improve the overall PV-T collector performance.
Zaguán. Repositorio Digital de la Universidad de Zaragoza
Publicación Artículo científico (JournalArticle)

Life Cycle Assessment of solar energy systems for the provision of heating, cooling and electricity in buildings: A comparative analysis

  • Herrando, María
  • Elduque, Daniel
  • Javierre, Carlos
  • Fueyo, Norberto
A detailed Life Cycle Assessment (LCA) “from cradle to grave” is performed to a solar combined cooling, heating and power (S-CCHP) system that provides space heating, cooling, domestic hot water and electricity, following two different methodologies (the ReCiPe 2016 Endpoint (H/A) v1.03 and the carbon footprint IPCC 2013 100 years). The innovative S-CCHP system is currently in operation in an industrial building located in Zaragoza (Spain), and the transient model developed to estimate the annual energy outputs has been validated. The system consists of hybrid photovoltaic-thermal (PV-T) collectors integrated via two parallel thermal storage tanks with an air-to-water reversible heat pump (rev-HP). Another contribution is that the detailed LCA analysis is also performed to a conventional PV-system and a grid-based system, viz building electricity consumption supplied from the grid (baseline configuration). The results show that the proposed S-CCHP system has half of the environmental impact of the grid-based system, according to the ReCiPe 2016 Endpoint (H/A) and the IPCC GWP 100a methods (4.48 kPts vs 8.87 kPts, and 82.4 tons of CO2 eq vs 166.9 tons of CO2 eq, respectively). The PV-system has 30% less environmental impact than the grid-based system. Another novelty and contribution are the sensitivity analyses performed to assess the influence of the system lifetime, the solar irradiance and the power generation mix (also known as the electricity mix) on the LCA results. The results show that the proposed S-CCHP system appears as an up-and-coming alternative to reduce the environmental impacts of buildings in all the considered solar irradiance levels and electricity mix scenarios, even in climates with low irradiance levels or in countries with a highly decarbonised electricity supply. © 2022 The Authors