Docta Complutense
Publicación Artículo científico (JournalArticle)

Robustness of single- and dual-energy deep-learning-based scatter correction models on simulated and real chest X-rays

  • Freijo, Clara
  • López Herraiz, Joaquín
  • Arias Valcayo, Fernando
  • Ibáñez García, Paula Beatriz
  • Moreno, Gabriela
  • Villa Abaunza, Amaia
  • Udías Moinelo, José Manuel
Chest X-rays (CXRs) represent the first tool globally employed to detect cardiopulmonary pathologies. These acquisitions are highly affected by scattered photons due to the large field of view required. Scatter in CXRs introduces background in the images, which reduces their contrast. We developed three deep-learning-based models to estimate and correct scatter contribution to CXRs. We used a Monte Carlo (MC) ray-tracing model to simulate CXRs from human models obtained from CT scans using different configurations (depending on the availability of dual-energy acquisitions). The simulated CXRs contained the separated contribution of direct and scattered X-rays in the detector. These simulated datasets were then used as the reference for the supervised training of several NNs. Three NN models (single and dual energy) were trained with the MultiResUNet architecture. The performance of the NN models was evaluated on CXRs obtained, with an MC code, from chest CT scans of patients affected by COVID-19. The results show that the NN models were able to estimate and correct the scatter contribution to CXRs with an error of <5%, being robust to variations in the simulation setup and improving contrast in soft tissue. The single-energy model was tested on real CXRs, providing robust estimations of the scatter-corrected CXRs.
Docta Complutense
Publicación Artículo científico (JournalArticle)

Reconstruction of multi-animal PET acquisitions with anisotropically variant PSF

  • Arias Valcayo, Fernando
  • Galve Lahoz, Pablo
  • López Herraiz, Joaquín
  • Vaquero, J J
  • Desco, M
  • Udías Moinelo, José Manuel
Among other factors such as random, attenuation and scatter corrections, uniform spatial resolution is key to performing accurate quantitative studies in Positron emission tomography (PET). Particularly in preclinical PET studies involving simultaneous acquisition of multiple animals, the degradation of image resolution due to the depth of interaction (DOI) effect far from the center of the Field of View (FOV) becomes a significant concern. In this work, we incorporated a spatially-variant resolution model into a real time iterative reconstruction code to obtain accurate images of multi-animal acquisition. We estimated the spatially variant point spread function (SV-PSF) across the FOV using measurements and Monte Carlo (MC) simulations. The SV-PSF obtained was implemented in a GPU-based Ordered subset expectation maximization (OSEM) reconstruction code, which includes scatter, attenuation and random corrections. The method was evaluated with acquisitions from two preclinical PET/CT scanners of the SEDECAL Argus family: a Derenzo phantom placed 2 cm off center in the 4R-SuperArgus, and a multi-animal study with 4 mice in the 6R-SuperArgus. The SV-PSF reconstructions showed uniform spatial resolution without significant increase in reconstruction time, with superior image quality compared to the uniform PSF model.