Publicación Artículo científico (JournalArticle)

Rotational Speed Control Using ANN-Based MPPT for OWC Based on Surface Elevation Measurements

  • M'Zoughi, Fares
  • Garrido Hernández, Izaskun
  • Garrido Hernández, Aitor Josu
  • De la Sen Parte, Manuel
This paper presents an ANN-based rotational speed control to avoid the stalling behavior in Oscillating Water Columns composed of a Doubly Fed Induction Generator driven by a Wells turbine. This control strategy uses rotational speed reference provided by an ANN-based Maximum Power Point Tracking. The ANN-based MPPT predicts the optimal rotational speed reference from wave amplitude and period. The neural network has been trained and uses wave surface elevation measurements gathered by an acoustic Doppler current profiler. The implemented ANN-based rotational speed control has been tested with two different wave conditions and results prove the effectiveness of avoiding the stall effect which improved the power generation., This work was supported in part by the Basque Government, through project IT1207-19 and by the MCIU/MINECO through RTI2018-094902-B-C21/RTI2018-094902-B-C22 (MCIU/AEI/FEDER, UE).
RUC. Repositorio da Universidade da Coruña
Publicación Contribución de congreso (ConferenceOutput)

Estabilización de eólica marina flotante mediante control de flujo de aire en columnas de agua oscilante, Airflow Control Strategy of Oscillating Water Columns for Floating Offshore Wind Turbine Stabilization

  • M’zoughi, Fares
  • Aboutalebi, Payam
  • Garrido, Izaskun
  • Garrido, Aitor J.
  • Sen, Manuel de la
[Resumen] En este artículo se presenta un nuevo tipo de control aplicado a una plataforma flotante multipropósito tipo barcaza capaz de aprovechar la energía eólica y undimotriz de manera simultánea. Además, los captadores de energía undimotriz se componen de columnas de agua oscilante (OWC) que ayudarán a estabilizar la plataforma y la turbina eólica flotante (FOWT) reduciendo el desplazamiento longitudinal de la parte superior de la torre. Para ello se implementa una estrategia de control de flujo de aire actuando sobre las válvulas de la cámara de captura de los dispositivos OWC. El estudio comparativo entre una FOWT estándar y la FOWT sobre la plataforma dotada de dispositivos controlados OWC propuesta, muestra una considerable mejora en la estabilidad del sistema., [Abstract] This paper presents the idea of incorporating oscillating water columns (OWCs) into the barge platform of a floating offshore wind turbines (FOWT) to make it a multi-purpose platform for harnessing both wind and wave energies. Moreover, the OWCs will help stabilize the FOWT platform by means of an airflow control strategy used to reduce the platform pitch and tower top fore-aft displacement. This is achieved by a proposed airflow control strategy to control the valves within the OWCs. The comparative study between a standard FOWT and the proposed OWC-based FOWT shows an improvement in the platform’s stability., Gobierno Vasco; IT1207-19, Este trabajo ha sido apoyado en parte por el Gobierno Vasco a través del proyecto IT1207-19 y por el MCIU/MINECO a través de los proyectos RTI2018-094902-B-C21 y RTI2018-094902-B-C22 (MCIU / AEI / FEDER, UE), https://doi.org/10.17979/spudc.9788497498043
RUC. Repositorio da Universidade da Coruña
Publicación Contribución de congreso (ConferenceOutput)

Nueva estrategia de control para la reducción de oscilaciones en turbinas eólicas flotantes, A Novel Control Strategy for Oscillation Reduction in Floating Wind Turbines

  • Aboutalebi, Payam
  • M’zoughi, Fares
  • Garrido, Izaskun
  • Garrido, Aitor J.
[Resumen] En este trabajo se ha propuesto una nueva estrategia de control para mejorar la estabilidad de turbinas eólicas flotantes (FWT). Al objeto de estudiar la reducción de oscilaciones no deseadas en el sistema, y en particular en los movimientos de cabeceo de la plataforma y de proa-popa de la nacelle, se ha considerado una plataforma tipo barcaza de forma cuadrada y equipada con cuatro columnas de agua oscilantes (OWC) colocadas de manera simétrica. De esta forma, las válvulas de control de flujo de aire de las cámaras de captura permiten operar las citadas columnas de aire para controlar los movimientos de la barcaza causados por la dinámica oscilatoria de la ola incidente. Para ello, se ha efectuado un análisis de los operadores de amplitud de respuesta (RAO) que permite implementar una nueva estrategia de control de conmutación para regular adecuadamente la transición apertura/cierre de las válvulas de control de flujo. Los resultados obtenidos muestran que la topología de plataforma híbrida propuesta, dotada de sistemas controlados OWC, presenta un mejor rendimiento que una plataforma análoga tradicional., [Abstract] In this work, a new control strategy has been proposed to improve the stability of floating wind turbines (FWT). In order to study the reduction of undesired oscillations in the system, and in particular in the platform pitch and fore-aft nacelle movements. A square-shaped barge-type platform has been considered and equipped with four symmetrically located Oscillating Water Columns (OWCs). In this way, the air flow control valves of the capture chambers allow the aforementioned air columns to be operated so that to control the movements of the barge caused by the oscillatory dynamics of the incident wave. To do so, an analysis of the response amplitude operators (RAO) has been carried out, which in turn allows the implementation of a new switching control strategy to properly regulate the transition of the flow control valves. The results obtained show that the proposed hybrid platform topology, equipped with OWC controlled systems, presents better performance than a traditional analog platform., Gobierno Vasco; IT1207-19, Los autores del presente trabajo quisieran agradecer el apoyo del Gobierno Vasco mediante el proyecto IT1207-19 y del MCIU/MINECO a través de los proyectos RTI2018-094902-B-C21 y RTI2018-094902-B-C22 (MCIU/AEI/FEDER, UE), https://doi.org/10.17979/spudc.9788497498043
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

On the use of entropy issues to evaluate and control the transients in some epidemic models

  • De la Sen, Manuel|||0000-0001-9320-9433
  • Nistal, Raul|||0000-0003-2196-1989
  • Ibeas, Asier|||0000-0001-5094-3152
  • Garrido, Aitor J.|||0000-0002-3016-4976
This paper studies the representation of a general epidemic model by means of a first-order differential equation with a time-varying log-normal type coefficient. Then the generalization of the first-order differential system to epidemic models with more subpopulations is focused on by introducing the inter-subpopulations dynamics couplings and the control interventions information through the mentioned time-varying coefficient which drives the basic differential equation model. It is considered a relevant tool the control intervention of the infection along its transient to fight more efficiently against a potential initial exploding transmission. The study is based on the fact that the disease-free and endemic equilibrium points and their stability properties depend on the concrete parameterization while they admit a certain design monitoring by the choice of the control and treatment gains and the use of feedback information in the corresponding control interventions. Therefore, special attention is paid to the evolution transients of the infection curve, rather than to the equilibrium points, in terms of the time instants of its first relative maximum towards its previous inflection time instant. Such relevant time instants are evaluated via the calculation of an "ad hoc" Shannon's entropy. Analytical and numerical examples are included in the study in order to evaluate the study and its conclusions.
Dipòsit Digital de Documents de la UAB
Publicación Artículo científico (JournalArticle)

Supervision of the infection in an si (Si-rc) epidemic model by using a test loss function to update the vaccination and treatment controls

  • De la Sen, Manuel|||0000-0001-9320-9433
  • Ibeas, Asier|||0000-0001-5094-3152
  • Nistal, Raul|||0000-0003-2196-1989
  • Alonso-Quesada, Santiago|||0000-0002-4724-7583
  • Garrido, Aitor J|||0000-0002-3016-4976
This paper studies and proposes some supervisory techniques to update the vaccination and control gains through time in a modified SI (susceptible-infectious) epidemic model involving the susceptible and subpopulations. Since the presence of linear feedback controls are admitted, a compensatory recovered (or immune) extra subpopulation is added to the model under zero initial conditions to deal with the recovered subpopulations transferred from the vaccination and antiviral/antibiotic treatment on the susceptible and the infectious, respectively. Therefore, the modified model is referred to as an SI(RC) epidemic model since it integrates the susceptible, infectious and compensatory recovered subpopulations. The defined time-integral supervisory loss function can evaluate weighted losses involving, in general, both the susceptible and the infectious subpopulations. It is admitted, as a valid supervisory loss function, that which involves only either the infectious or the susceptible subpopulations. Its concrete definition involving only the infectious is related to the Shannon information entropy. The supervision problem is basically based on the implementation of a parallel control structure with different potential control gains to be judiciously selected and updated through time. A higher decision level structure of the supervisory scheme updates the appropriate active controller (i.e., that with the control gain values to be used along the next time window), as well as the switching time instants. In this way, the active controller is that which provides the best associated supervisory loss function along the next inter-switching time interval. Basically, a switching action from one active controller to another one is decided as a better value of the supervisory loss function is detected for distinct controller gain values to the current ones.