Pasar al contenido principal

SISTEMAS LOCALES DE LOCALIZACION: ENFOQUE HOLISTICO DESDE EL SENSADO A LA ANALITICA

RTI2018-095168-B-C55

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 9
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Energy-Efficient Indoor Localization WiFi-Fingerprint System: An Experimental Study

  • Salazar González, Jose L.
  • Soria Morillo, Luis Miguel
  • Álvarez-García, Juan A.
  • Enríquez de Salamanca Ros, Fernando
  • Jiménez Ruiz, Antonio R.
In order to apply indoor localization systems in real environments it is necessary to provide an accurate location without implying a high impact on the user’s normal behaviour. To achieve this goal, in this paper, a combination of battery saving techniques with a system based on WiFi fingerprinting is proposed. This is done by transferring the location calculation workload to the server, leaving user’s mobile devices the only responsibility of making periodic WiFi network scans at dynamic intervals based on user activity, through an application running on background. There are not many studies analyzing energy consumption of existing localization systems, even though it is an important factor in real applications. In this paper, both energy consumption and accuracy are analyzed, having an energy consumption of only 0.8 Wh (having a 3.7 V battery) during a 24-hour cycle and an average localization error of 4.51 meters. Worth to mention that as computation is done on server side the system can be expanded to multiple buildings and floors. Finally, the dataset used in this paper has been published making possible to test new algorithms in the same environment., This work was supported in part by the Spanish Ministry of Economy and Competitiveness through the VICTORY Project under Grant TIN2017-82113-C2-1-R MINECO/FEDER R&D, UE, and in part by the Spanish Ministry of Science, Innovation, and Universities through the MICROCEBUS Project under Grant RTI2018-095168-B-C55 MCIU/AEI/FEDER,UE., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Detecting Fall Risk and Frailty in Elders with Inertial Motion Sensors: A Survey of Significant Gait Parameters

  • Ruiz-Ruiz, Luisa
  • Jiménez Ruiz, Antonio R.
  • García-Villamil, Guillermo
  • Seco Granja, Fernando
In the elderly, geriatric problems such as the risk of fall or frailty are a challenge for society. Patients with frailty present difficulties in walking and higher fall risk. The use of sensors for gait analysis allows the detection of objective parameters related to these pathologies and to make an early diagnosis. Inertial Measurement Units (IMUs) are wearables that, due to their accuracy, portability, and low price, are an excellent option to analyze human gait parameters in health-monitoring applications. Many relevant gait parameters (e.g., step time, walking speed) are used to assess motor, or even cognitive, health problems in the elderly, but we perceived that there is not a full consensus on which parameters are the most significant to estimate the risk of fall and the frailty state. In this work, we analyzed the different IMU-based gait parameters proposed in the literature to assess frailty state (robust, prefrail, or frail) or fall risk. The aim was to collect the most significant gait parameters, measured from inertial sensors, able to discriminate between patient groups and to highlight those parameters that are not relevant or for which there is controversy among the examined works. For this purpose, a literature review of the studies published in recent years was carried out; apart from 10 previous relevant reviews using inertial and other sensing technologies, a total of 22 specific studies giving statistical significance values were analyzed. The results showed that the most significant parameters are double-support time, gait speed, stride time, step time, and the number of steps/day or walking percentage/day, for frailty diagnosis. In the case of fall risk detection, parameters related to trunk stability or movements are the most relevant. Although these results are important, the total number of works found was limited and most of them performed the significance statistics on subsets of all possible gait parameters; this fact highlights the need for new frailty studies using a more complete set of gait parameters., This research was funded by the European Union, NEXTPERCEPTION project, Grant No. ECSEL-2019-2-RIA, Ref. 876487, and by the Spanish Ministry of Science, Grant No. MICROCEBUS RTI2018-095168-B-C55 (MCIU/AEI/FEDER, UE)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Datasets and Supporting Materials for the IPIN 2020 Competition Track 3 (Smartphone-based, off-site)

  • Torres-Sospedra, Joaquín
  • Quezada Gaibor, Darwin
  • Jiménez Ruiz, Antonio R.
  • Pérez-Navarro, Antoni
  • Seco Granja, Fernando
This package contains the datasets and supplementary materials used in the IPIN 2020 Competition. Contents: IPIN2020_Track03_TechnicalAnnex_V1-01.pdf: Technical annex describing the competition 01-Logfiles: This folder contains a subfolder with the 78 training logfiles, 72 of them single floor, 4 in bookshelves areas and 2 of them in floor-transition zones, a subfolder with the 13 validation logfiles, and a subfolder with the 1 blind evaluation logfile as provided to competitors. 02-Supplementary_Materials: This folder contains the matlab/octave parser, the raster maps, the files for the matlab tools and the trajectory visualization. 03-Evaluation: This folder contains the scripts used to calculate the competition metric, the 75th percentile on the 82 evaluation points. It requires the Matlab Mapping Toolbox. The ground truth is also provided as a CSV file. Since the results must be provided with a 2Hz freq. starting from apptimestamp 0, the GT includes the closest timestamp matching the timing provided by competitors. It contains a sample of reported estimations and the corresponding results. Additionally, we provide a second script to provide a more detailed report on the results file (requires export_fig folder to run)., Parts of this work were carried out with the financial support received from projects and grants: - A-WEAR (H2020-MSCA-ITN-2018, Grant Agreement 813278) - INSIGNIA (PTQ2018-009981) - REPNIN+ network (TEC2017-90808-REDT) - LORIS (TIN2012-38080-C04-04) - SmartLoc(CSIC-PIE Ref.201450E011) - TARSIUS (TIN2015-71564-C4-2-R, MINECO/FEDER) - MICROCEBUS (MICINN, ref. RTI2018-095168-B-C55, MCIU/AEI/FEDER UE) ., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Datasets and Supporting Materials for the IPIN 2021 Competition Track 3 (Smartphone-based, off-site)

  • Torres-Sospedra, Joaquín
  • Aranda Polo, Fernando J.
  • Parralejo, Felipe
  • Bellavista Parent, Vladimir
  • Álvarez, Fernando J.
  • Pérez-Navarro, Antoni
  • Jiménez Ruiz, Antonio R.
  • Seco Granja, Fernando
This package contains the datasets and supplementary materials used in the IPIN 2021 Competition. Contents: IPIN2021_Track03_TechnicalAnnex_V1-02.pdf: Technical annex describing the competition 01-Logfiles: This folder contains a subfolder with the 105 training logfiles, 80 of them single floor indoors, 10 in outdoor areas, 10 of them in the indoor auditorium with floor-trasitio and 5 of them in floor-transition zones, a subfolder with the 20 validation logfiles, and a subfolder with the 3 blind evaluation logfile as provided to competitors. 02-Supplementary_Materials: This folder contains the matlab/octave parser, the raster maps, the files for the matlab tools and the trajectory visualization. 03-Evaluation: This folder contains the scripts used to calculate the competition metric, the 75th percentile on the 82 evaluation points. It requires the Matlab Mapping Toolbox. The ground truth is also provided as 3 csv files. Since the results must be provided with a 2Hz freq. starting from apptimestamp 0, the GT files include the closest timestamp matching the timing provided by competitors for the 3 evaluation logfiles. It contains samples of reported estimations and the corresponding results., We would like to thank GISS Research team at University of Extremadura for their support in colllecting the datasets and the ISTI-CNR for managing the competition and find sponsors for the winner's award. We are also grateful to Francesco Potortì, Sangjoon Park and the ISTI-CNR team for their invaluable committment in organizing and promoting the IPIN competition and conference. This work has been done within the framework of the IPIN 2021 Conference in Lloret de Mar, organised by A. Pérez-Navarro, R. Montoliu and J. Torres-Sospedra. Parts of this work were carried out with the financial support received from projects and grants: - A-WEAR (H2020-MSCA-ITN-2018, Grant Agreement 813278) - INSIGNIA (PTQ2018-009981) - REPNIN+ network (TEC2017-90808-REDT) - LORIS (TIN2012-38080-C04-04) - SmartLoc(CSIC-PIE Ref.201450E011) - TARSIUS (TIN2015-71564-C4-2-R, MINECO/FEDER) - MICROCEBUS (MICINN, ref. RTI2018-095168-B-C55, MCIU/AEI/FEDER UE), Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Off-Line Evaluation of Indoor Positioning Systems in Different Scenarios: The Experiences From IPIN 2020 Competition

  • Potortì, Francesco
  • Torres-Sospedra, Joaquín
  • Quezada Gaibor, Darwin
  • Jiménez Ruiz, Antonio R.
  • Seco Granja, Fernando
  • Pérez-Navarro, Antoni
  • Ortiz, Miguel
  • Zhu, Ni
  • Renaudin, Valerie
  • Ichikari, Ryosuke
  • Shimomura, Ryo
  • Plets, David
  • Opiela, Miroslav
  • Džama, Jakub
  • Zhang, Liqiang
  • Li, Hu
  • Chen, Boxuan
  • Liu, Yu
  • Yean, Seanglidet
  • Lim, Bo Zhi
  • Teo, Wei Jie
  • Lee, Bu Sung
  • Oh, Hong Lye
  • Ohta, Nozomu
  • Nagae, Satsuki
  • Kurata, Takeshi
  • Wei, Dongyan
  • Ji, Xinchun
  • Zhang, Wenchao
  • Kram, Sebastian
  • Stahlke, Maximilian
  • Mutschler, Christopher
  • Crivello, Antonino
  • Barsocchi, Paolo
  • Girolami, Michele
  • Palumbo, Filippo
  • Chen, Ruizhi
  • Wu, Yuan
  • Li, Wei
  • Yu, Yue
  • Xu, Shihao
  • Huang, Lixiong
  • Liu, Tao
  • Kuang, Jian
  • Niu, Xiaoji
  • Yoshida, Takuto
  • Nagata, Yoshiteru
  • Fukushima, Yuto
  • Fukatani, Nobuya
  • Hayashida, Nozomi
  • Asai, Yusuke
  • Urano, Kenta
  • Ge, Wenfei
  • Lee, Nien-Ting
  • Fang, Shih-Hau
  • Jie, You-Cheng
  • Young, Shawn-Rong
  • Chien, Ying-Ren
  • Yu, Chih-Chieh
  • Ma, Chengqi
  • Wu, Bang
  • Zhang, Wei
  • Wang, Yankun
  • Fan, Yonglei
  • Poslad, Stefan
  • Selviah, David R.
  • Wang, Weixi
  • Yuan, Hong
  • Yonamoto, Yoshitomo
  • Yamaguchi, Masahiro
  • Kaichi, Tomoya
  • Zhou, Baoding
  • Liu, Xu
  • Gu, Zhining
  • Yang, Chengjing
  • Wu, Zhiqian
  • Xie, Doudou
  • Huang, Can
  • Zheng, Lingxiang
  • Peng, Ao
  • Jin, Ge
  • Wang, Qu
  • Luo, Haiyong
  • Xiong, Hao
  • Bao, Linfeng
  • Zhang, Pushuo
  • Zhao, Fang
  • Yu, Chia-An
  • Hung, Chun-Hao
  • Antsfeld, Leonid
  • Chidlovskii, Boris
  • Jiang, Haitao
  • Xia, Ming
  • Yan, Dayu
  • Li, Yuhang
  • Dong, Yitong
  • Silva, Ivo
  • Pendão, Cristiano
  • Meneses, Filipe
  • Nicolau, Maria João
  • Costa, António
  • Moreira, Adriano
  • De Cock, Cedric
Every year, for ten years now, the IPIN competition has aimed at evaluating real-world indoor localisation systems by testing them in a realistic environment, with realistic movement, using the EvAAL framework. The competition provided a unique overview of the state-of-the-art of systems, technologies, and methods for indoor positioning and navigation purposes. Through fair comparison of the performance achieved by each system, the competition was able to identify the most promising approaches and to pinpoint the most critical working conditions. In 2020, the competition included 5 diverse off-site off-site Tracks, each resembling real use cases and challenges for indoor positioning. The results in terms of participation and accuracy of the proposed systems have been encouraging. The best performing competitors obtained a third quartile of error of 1 m for the Smartphone Track and 0.5 m for the Foot-mounted IMU Track. While not running on physical systems, but only as algorithms, these results represent impressive achievements., Track 3 organizers were supported by the European Union’s Horizon 2020 Research and Innovation programme under the Marie Skłodowska Curie Grant 813278 (A-WEAR: A network for dynamic WEarable Applications with pRivacy constraints), MICROCEBUS (MICINN, ref. RTI2018-095168-B-C55, MCIU/AEI/FEDER UE), INSIGNIA (MICINN ref. PTQ2018-009981), and REPNIN+ (MICINN, ref. TEC2017-90808-REDT). We would like to thanks the UJI’s Library managers and employees for their support while collecting the required datasets for Track 3. Track 5 organizers were supported by JST-OPERA Program, Japan, under Grant JPMJOP1612. Track 7 organizers were supported by the Bavarian Ministry for Economic Affairs, Infrastructure, Transport and Technology through the Center for Analytics-Data-Applications (ADA-Center) within the framework of “BAYERN DIGITAL II. ” Team UMinho (Track 3) was supported by FCT—Fundação para a Ciência e Tecnologia within the R&D Units Project Scope under Grant UIDB/00319/2020, and the Ph.D. Fellowship under Grant PD/BD/137401/2018. Team YAI (Track 3) was supported by the Ministry of Science and Technology (MOST) of Taiwan under Grant MOST 109-2221-E-197-026. Team Indora (Track 3) was supported in part by the Slovak Grant Agency, Ministry of Education and Academy of Science, Slovakia, under Grant 1/0177/21, and in part by the Slovak Research and Development Agency under Contract APVV-15-0091. Team TJU (Track 3) was supported in part by the National Natural Science Foundation of China under Grant 61771338 and in part by the Tianjin Research Funding under Grant 18ZXRHSY00190. Team Next-Newbie Reckoners (Track 3) were supported by the Singapore Government through the Industry Alignment Fund—Industry Collaboration Projects Grant. This research was conducted at Singtel Cognitive and Artificial Intelligence Lab for Enterprises (SCALE@NTU), which is a collaboration between Singapore Telecommunications Limited (Singtel) and Nanyang Technological University (NTU). Team KawaguchiLab (Track 5) was supported by JSPS KAKENHI under Grant JP17H01762. Team WHU&AutoNavi (Track 6) was supported by the National Key Research and Development Program of China under Grant 2016YFB0502202. Team YAI (Tracks 6 and 7) was supported by the Ministry of Science and Technology (MOST) of Taiwan under Grant MOST 110-2634-F-155-001., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Assessing falls in the elderly population using G-STRIDE foot-mounted inertial sensor

  • Neira Álvarez, Marta
  • Jiménez Ruiz, Antonio R.
  • García Villamil, Guillermo
  • Huertas-Hoyas, Elisabet
  • Espinoza Cerda, Maria Teresa
  • Pérez Delgado, Laura
  • Reina Robles, Elena
  • Del Ama Espinosa, Antonio José
  • Ruiz-Ruiz, Luisa
  • García de Villa, Sara
  • Rodríguez Sánchez, Cristina
Falls are one of the main concerns in the elderly population due to their high prevalence and associated consequences. Guidelines for the management of the elder with falls are comprised of multidimensional assessments, especially gait and balance. Daily clinical practice needs for timely, effortless, and precise tools to assess gait. This work presents the clinical validation of the G-STRIDE system, a 6-axis inertial measurement unit (IMU) with onboard processing algorithms, that allows the calculation of walking-related metrics correlated with clinical markers of fall risk. A cross-sectional case-control study was conducted with 163 participants (falls and non-falls groups). All volunteers were assessed with clinical scales and conducted a 15-min walking test at a self-selected pace while wearing the G-STRIDE. G-STRIDE is a low-cost solution to facilitate the transfer to society and clinical evaluations. It is open hardware and flexible and, thus, has the advantage of providing runtime data processing. Walking descriptors were derived from the device, and a correlation analysis was conducted between walking and clinical variables. G-STRIDE allowed measuring walking parameters in non-restricted walking conditions (e.g. hallway). Walking parameters statistically discriminate between falls and non-falls groups. We found good/excellent estimation accuracy (ICC = 0.885; p<0.000) for walking speed, showing good/excellent correlation between gait speed and several clinical variables. G-STRIDE can calculate walking-related metrics that allow for discrimination between falls and non-falls groups, which correlates with clinical indicators of fall risk. A preliminary fall-risk assessment based on the walking parameters was found to improve the Timed Up and Go test in the identification of fallers., Spanish Ministry of Science, Grants No. MICROCEBUS RTI2018-095168-B-C55 and INDRI PID2021-122642OB-C43 (MCIU/AEI/10.13039/501100011033/FEDER, UE) and NEXTPERCEPTION European Union NextGenerationEU/PRTR project funded by ECSEL Joint Undertaking (JU), under Grant agreement No. 876487 (ECSEL-2019-2-RIA), which receives support from the European Union’s Horizon 2020 research and innovation programm and Finland, Spain (MCIN/AEI PCI2020-112040), Italy, Germany, Czech Republic, Belgium, Netherlands and FUNDACION MAPFRE “Ayudas a la investigación de Ignacio H. de Larramendi, año 2020”., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Stratification of Older Adults According to Frailty Status and Falls Using Gait Parameters Explored Using an Inertial System

  • Neira Álvarez, Marta
  • Huertas-Hoyas, Elisabet
  • Novak, Robert
  • Sipols, Ana Elizabeth
  • García-Villamil, Guillermo
  • Rodríguez Sánchez, María Cristina
  • Del-Ama, Antonio J.
  • Ruiz-Ruiz, Luisa
  • García-de-Villa, Sara
  • Jiménez Ruiz, Antonio R.
Background: TheWorld Health Organization recommends health initiatives focused on the early detection of frailty and falls. Objectives: 1—To compare clinical characteristics, functional performance and gait parameters (estimated with the G-STRIDE inertial sensor) between different frailty groups in older adults with and without falls. 2—To identify variables that stratify participants according to frailty status and falls. 3—To verify the sensitivity, specificity and accuracy of the model that stratifies participants according to frailty status and falls. Methods: Observational, multicenter case-control study. Participants, adults over 70 years with and without falls were recruited from two outpatient clinics and three nursing homes from September 2021 to March 2022. Clinical variables and gait parameters were gathered using the G-STRIDE inertial sensor. Random Forest regression was applied to stratify participants. Results: 163 participants with a mean age of 82.6 ± 6.2 years, of which 118 (72%) were women, were included. Significant differences were found in all gait parameters (both conventional assessment and G-STRIDE evaluation). A hierarchy of factors contributed to the risk of frailty and falls. The confusion matrix and the performance metrics demonstrated high accuracy in classifying participants. Conclusions: Gait parameters, particularly those assessed by G-STRIDE, are effective in stratifying individuals by frailty status and falls. These findings underscore the importance of gait analysis in early intervention strategies, This research was funded by G-STRIDE de la Convocatoria Fundación Mapfre—ayudas a la investigación Ignacio Larramendi 2021; MI-CROCEBUS RTI2018-095168-B-C55 (MCIU/AEI/FEDER, UE) for the development of CSIC PDR techniques. Collaboration with laboratories SENIALAB (Laboratorio de sistemas de navegación sensorial y de sistemas de monitorización) of the REDLABU of the Universidad Rey Juan Carlos and CAR-CSIC, Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

A database with frailty, functional and inertial gait metrics for the research of fall causes in older adults

  • García-de-Villa, Sara
  • García-Villamil Neira, Guillermo
  • Neira Álvarez, Marta
  • Huertas-Hoyas, Elisabet
  • Ruiz-Ruiz, Luisa
  • del-Ama, Antonio J
  • Rodríguez Sánchez, María Cristina
  • Jiménez Ruiz, Antonio R.
The GSTRIDE database contains information of the health status assessment of 163 elderly adults. We provide socio-demographic data, functional and frailty variables, and the outcomes from tests commonly performed for the evaluation of elder people. the database contains gait parameters estimated from the measurements of an Inertial Measurement Unit (IMU) placed on the foot of volunteers. these parameters include the total walking distance, the number of strides and multiple spatio-temporal gait parameters, such as stride length, stride time, speed, foot angles and clearance, among others. the main processed database is stored, apart from MS Excel, in CSV format to ensure their usability. the database is complemented with the raw IMU recordings in tXt format, in order to let researchers test other algorithms of gait analysis. We include the Python programming codes as a base to reproduce or modify them. the database stores data to study the frailty-related parameters that distinguish faller and non-faller populations, and analyze the gait-related parameters in the frail subjects, which are essential topics for the elderly., This dataset creation was supported by a grant from the FUNDACIÓN MAPFRE “Ayudas a la investigación de Ignacio H. de Larramendi, 2020” and the contributions from other complementary resources: GAIT2CARE NextGeneration EU/PRTR project (TED2021-132429B-I00) by MCIN/AEI/10.13039/501100011033, INDRI PID2021-122642OB-C43 (MCIU/AEI/10.13039/501100011033/FEDER, UE), Spanish Ministry of Science, Grant No. MICROCEBUS RTI2018-095168-B-C55 (MCIU/AEI/FEDER, UE) and NEXTPERCEPTION European Union project funded by ECSEL Joint Undertaking (JU), under grant agreement No.876487 (ECSEL-2019-2-RIA), which receives support from the European Union’s Horizon 2020 research and innovation program and Finland, Spain (MCIN/AEI PCI2020-112040), Italy, Germany, Czech Republic, Belgium, Netherlands., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Datos de investigación Set de datos (Dataset)

Datasets and Supporting Materials for the IPIN 2025 Competition Track 3 (Smartphone-based, off-site)

  • Torres-Sospedra, Joaquín
  • Jiménez Ruiz, Antonio R.
  • Pérez-Navarro, Antoni
  • Palumbo, Filippo
  • La Rosa, Davide
  • Potortì, Francesco
  • Klus, Lucie
  • Klus, Roman
  • Ometov, Aleksandr
  • Lohan, Elena Simona
  • Nurmi, Jari
  • Ortiz, Miguel
The Track 3 competition aims to benchmark indoor localization methods based on smartphone sensors and radio signals, such as Wi-Fi, BLE, magnetic field, inertial, pressure, light, sound, and GNSS data. The recordings were performed in a realistic multi-floor university building while participants moved naturally through various environments., This work and competition are part of the IPIN 2025 Conference in Tampere, Finland., This dataset was collected for the IPIN 2025 Indoor Positioning Competition – Track 3 ("Smartphone-based"), organized within the 15th International Conference on Indoor Positioning and Indoor Navigation (IPIN 2025) in Tampere, Finland., This package provides the complete data used in the competition — including training, testing, and scoring trials, as well as the Matlab tools, maps, and evaluation scripts supporting the generation and assessment of the results., - POSITIONATE (CIDEXG/2023/17, Conselleria d’Educació, Universitats i Ocupació, Generalitat Valenciana) - GeoLibero (from CYTED) - INDRI (MICINN, ref. PID2021-122642OB-C42, PID2021-122642OB-C43, PID2021-122642OB-C44, MCIU/AEI/FEDER UE) - MICROCEBUS (MICINN, ref. RTI2018-095168-B-C55, MCIU/AEI/FEDER UE) - TARSIUS (TIN2015-71564-C4-2-R, MINECO/FEDER) - SmartLoc (CSIC-PIE Ref.201450E011) - LORIS (TIN2012-38080-C04-04), Peer reviewed