Pasar al contenido principal

ELIMINACION E INFLUENCIA DE LOS MICROPLASTICOS Y NANOPLASTICOS EN BIORREACTORES DE MEMBRANA Y EN PROCESOS DE REGENERACION DE AGUAS RESIDUALES CON MEMBRANAS

RTI2018-096916-B-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT POLITÈCNICA DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 13
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Influence of bisphenol A occurrence in wastewaters on biomass characteristics and activated sludge process performance

  • Ferrer-Polonio, Eva|||0000-0001-6412-3825
  • Mendoza Roca, José Antonio
  • Bes-Piá, M.A.|||0000-0001-8005-7450
  • Alonso Molina, José Luís|||0000-0002-2079-910X
  • Bretas Alvim, C.
  • Fernández-Navarro, J.
  • Mompó-Curell, R.
  • Amoros, Inmaculada
[EN] In this work, the influence of bisphenol A (BPA) on biological wastewater treatment was studied. For it, two sequencing batch reactors (SBRs) were operated for three months. Both SBRs were fed with synthetic wastewater (SW), adding 1 mg.L-1 of BPA into the feed of reactor SBR-BPA, while the other one operatedwithout BPA as a control reactor (SBR-B). In addition, batch experiments were performed with adapted and non-adapted activated sludge, simulating the reaction step of SBR-BPA, to determine the pathways for BPA removal. Results of batch experiments showed that adsorption and biodegradation were the only significant BPA removal routes. BPA removal by biodegradation was more efficient when adapted biomass was used in the tests (32.2% and 8.2% with adapted and non-adapted biomass, respectively), while BPA adsorption removal route was similar in both types of activated sludge (around 40%). Regarding the SBRs experiments, after 16 days no BPA concentration was detected in SBR-BPA effluent. In the adaptation process, SBR-BPA biomass was more sensitive to low temperatures resulting in higher effluent turbidity, COD and solublemicrobial products concentrations than in SBR-B. However, once temperature increased, adapted biomass from SBR-BPA presented higher activity than SBR-B biomass, showing higher values of sludge production, microbial hydrolytic enzymatic activities and specific dynamic respiration rate. The bacterial community study revealed the increase of abundance of Proteobacteria (especially Thiothrix species) and Actinobacteria (especially Nocardioides species) phyla at the expense of Bacteroidetes and Chloroflexi phyla in SBR-BPA during its operation., Authors thank the Spanish Ministry of Science, Innovation and Universities for the financial support (Reference of the project: RTI2018096916BI00).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Identification of microfibers in drinking water with Nile Red. Limitations and strengths

  • Alvim, C. Bretas
  • Bes-Piá, M.A.|||0000-0001-8005-7450
  • Mendoza Roca, José Antonio
  • Alonso Molina, José Luís|||0000-0002-2079-910X
[EN] Traditional drinking water treatment plants (DWTP) are not specifically designed for removing microplastics (MPs) from drinking water. Therefore, this emergent contaminant has been identified in water sources and final drinking water. Microfibers from plastic-based materials are a relevant category of MPs that has attracted attention in recent studies due to their significant presence in environmental samples. This study investigated the presence of microfibers (> 10 & mu;m) in the raw water and the final drinking water of a DWTP located in Spain. It was observed that the DWTP studied was capable of removing 86% of microfibers from raw water. Even with this high removal rate, an amount of 613 microfibers/L (including natural, artificial, and synthetic materials) was counted in drinking water after disinfection. The reactive Nile Red was tested to investigate its use for staining microfibers from the mentioned DWTP and also from tap and bottled water samples in order to identify them. It was observed that microfibers from environmental samples can have different manifestations of fluorescence compared to pristine polymers, and it could be related to degrees of degradation and/or adsorption of organic and inorganic material on the microfibers' surfaces. For this reason, the use of Nile Red could help understand the levels of degradation of these materials in the environment, and thus its use could go beyond the identification of MPs, which was initially proposed in previous studies., Authors thank the Spanish Ministry of Science, Innovation, and Universities for the financial support (Reference of the project: RTI2018-096916-B-I00).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Methodology for removing microplastics and other anthropogenic microparticles from sludge dewatering system

  • Alvim, C. Bretas
  • Navajas-Valiente, Samuel|||0009-0007-1379-9316
  • Bes-Piá, M.A.|||0000-0001-8005-7450
  • Mendoza Roca, José Antonio
[EN] Anthropogenic microparticles (e.g., microplastics) are present in sewage plants, especially in sludge streams. However, the lack of standardized protocols to scrutinize the presence of anthropogenic microparticles in sludge makes the comparison between studies unfeasible. To tackle the knowledge gap regarding the efficiency of methodologies on the extraction of anthropogenic microparticles from the complex organic matrix, dewatered sludge, and digested sludge was treated with peroxidation and density separation, and the recovery of microparticles from these samples was investigated. The results showed that with the use of a higher density solution (NaI, 1.5 g/cm(3)) a much better recovery of anthropogenic microparticles from sludge samples (approximately 1000 microparticles/g-dw and 2000 microparticles/g-dw, from dewatered and digested sludge, respectively) was achieved in comparison with the use of a lower density solution (NaCl, 1.2 g/cm(3)) (200 microparticles/g-dw and 600 microparticles/g-dw from dewatered and digested sludge, respectively). Moreover, although the use of peroxidation is an essential step to break down the sludge structure and to release microparticles to the liquid phase, the use of peroxidation after or before density separation did not affect the overall recovery of microparticles. Polyethylene, polypropylene, and copolymer ethylene-ethyl-acrylate were the main microplastic fragments identified in digested sludge and dewatered sludge. However, no relation was observed between the method applied and the polymer recovered. Regarding the presence of anthropogenic microparticle in centrifuge effluent, 450 +/- 212 microparticles/L were counted, and although little is known about this stream, in can be a relevant source of anthropogenic microparticles., Authors thank the Spanish Ministry of Science, Innovation and Universities for the financial support (Reference of the project: RTI 2018-096916-B-I00)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Tesis doctoral (DoctoralThesis)

Caracterización de microplásticos en aguas naturales y residuales, y su influencia y separación en procesos biológicos de depuración

  • Bretas Alvim, Clara
[ES] Los microplásticos (MPs) son partículas de material plástico menores que 5 mm que están siendo identificadas en el agua, tierra y aire. La presencia de estos contaminantes emergentes en el medio ambiente supone una preocupación global actualmente, ya que no se sabe con exactitud su concentración y composición debido a la falta de protocolos de cuantificación e identificación estandarizados en los diferentes medios donde se encuentran. Igualmente, se desconoce el alcance de los efectos negativos que podrían provocar en el medio ambiente. La presente tesis estudia la presencia de microplásticos en diferentes corrientes de agua residual y natural, así como en fangos de depuración generados en las estaciones depuradoras de aguas residuales. El objetivo principal de la tesis consiste en evaluar diferentes protocolos para la extracción de microplásticos contenidos en muestras con diferentes características, así como su cuantificación e identificación. Para ello, se propusieron metodologías para la extracción de microplásticos en matrices con elevada carga orgánica (licor mezcla, fango digerido anaeróbicamente y fango deshidratado) y también en efluentes residuales, así como en aguas naturales tratadas (potables) y sin tratar. Asimismo, se evaluaron los posibles efectos de la presencia de microplásticos en un proceso de depuración mediante un reactor biológico de fangos activos, así como la distribución de estas micropartículas en el fango y en el efluente depurado. Además, se contempló también la posible fragmentación de microplásticos en nanoplásticos (NPs) en un sistema de depuración de aguas residuales y, por lo tanto, también se evaluaron los posibles efectos de los nanoplásticos en la biomasa de los fangos activos. Se observó que cuanto mayor era la concentración de carga orgánica en una muestra más difícil era el proceso tanto de purificación de la muestra como de identificación de microplásticos. Por lo tanto, para las muestras de fango fue necesario aplicar protocolos más complejos de extracción de microplásticos. La peroxidación, demostró ser un tratamiento eficaz de todas las muestras estudiadas, resultando en la reducción de la materia orgánica y en la mejora de la identificación visual. En los ensayos con el reactor biológico se observó una acumulación significativa de microplásticos en el licor mezcla (fango activo) frente al efluente. Esta acumulación de microplásticos en el fango puede suponer la contaminación de los suelos agrícolas cuando estos son aplicados como fertilizantes. Con el objetivo de mitigar la contaminación de suelos agrícolas por microplasticos presentes en fangos, se propuso el uso de la técnica de ultrasonidos para la extracción de estas micropartículas presentes en el licor de mezcla. Mediante esta técnica, cantidades significativas de microplasticos fueron separadas de la matriz orgánica de los fangos, que es la que se aplica al campo. Finalmente, se estudió la presencia de microfibras en aguas naturales y potables mediante a técnica de tinción con Rojo Nilo con el objetivo de investigar la viabilibilidad y limitaciones de este método. Se observó que la emisión de fluorescencia, por parte de microfibras vírgenes y microfibras separadas de estas muestras de agua, puede manifestar diferentes comportamientos de fluorescencia lo cual podría estar relacionado con el grado de degradación de los materiales de las microfibras., [CA] Els microplàstics (MPs) són partícules de material plàstic menors que 5 mm que estan siguent identificades en l'aigua, terra i aire. Actualment, la presència d'aquests contaminants emergents en el medi ambient suposa una preocupació global, ja que no se sap amb exactitud la seua concentració i composició a causa de la falta de protocols de quantificació i identificació estandarditzats en els diferents medis on es troben. Igualment, es desconeix l'abast dels efectes negatius que podrien provocar en el medi ambient. La present tesi estudia la presència de microplàstics en diferents corrents d'aigua residual i natural, així com en fangs de depuració generats en les estacions depuradores d'aigües residuals. L'objectiu principal de la tesi consisteix a avaluar diferents protocols per a l'extracció de microplàstics continguts en mostres amb diferents característiques, així com la seua quantificació i identificació. Per a això, es van proposar metodologies per a l'extracció de microplàstics en matrius amb elevada càrrega orgànica (licor mescla, fang digerit anaeróbicamente i fang deshidratat) i també en efluents residuals, així com en aigües naturals tractades (potables) i sense tractar. Així mateix, es van avaluar els possibles efectes de la presència de microplàstics en un procés de depuració mitjançant un reactor biològic de fangs actius, així com la distribució d'aquestes micropartícules en el fang i en l'efluent depurat. A més, es va contemplar també la possible fragmentació de microplàstics en nanoplásticos (NPs) en un sistema de depuració d'aigües residuals i, per tant, també es van avaluar els possibles efectes dels nanoplásticos en la biomassa dels fangs actius. Es va observar que com més gran era la concentració de càrrega orgànica en una mostra, més difícil era el procés tant de purificació de la mostra com d'identificació de microplàstics. Per tant, per a les mostres de fang va ser necessari aplicar protocols més complexos d'extracció de microplàstics. La peroxidació, va demostrar ser un tractament eficaç de totes les mostres estudiades, resultant en la reducció de la matèria orgànica i en la millora de la identificació visual. En els assajos amb el reactor biològic es va observar una acumulació significativa de microplàstics en el licor mescla (fang actiu) enfront de l'efluent. Aquesta acumulació de microplàstics en el fang pot suposar la contaminació dels sòls agrícoles quan aquests són aplicats com a fertilitzants. Amb l'objectiu de mitigar la contaminació de sòls agrícoles per microplàstics presents en fangs, es va proposar l'ús de la tècnica d'ultrasons per a l'extracció d'aquestes micropartícules presents en el licor de mescla. Mitjançant aquesta tècnica, quantitats significatives de microplàstics van ser separades de la matriu orgànica dels fangs, que és la que s'aplica al camp. Finalment, es va estudiar la presència de microfibres en aigües naturals i potables mitjançant a tècnica de tinció amb Rojo Nil amb l'objectiu d'investigar la viabilibilitat i limitacions d'aquest mètode. Es va observar que l'emissió de fluorescència, per part de microfibres verges i microfibres separades d'aquestes mostres d'aigua, pot manifestar diferents comportaments de fluorescència la qual cosa podria estar relacionada amb el grau de degradació dels materials de les microfibres., [EN] Microplastics (MPs) are particles of plastic material smaller than 5 mm that are being identified in water, soil, and air. The presence of these emerging contaminants in the environment is currently a global concern since their concentration and composition are unknown exactly due to the lack of standardized quantification and identification protocols in the different media where they are found. Likewise, the extent of the negative effects that they could cause in the environment is unknown. This thesis studies the presence of microplastics in different streams of wastewater and natural water, as well as in sewage sludge generated in wastewater treatment plants. The main objective of the thesis is to evaluate different protocols for the extraction of microplastics contained in samples with different characteristics, as well as their quantification and identification. For this, methodologies were proposed for the extraction of microplastics in matrices with a high organic load (mixed liquor, anaerobically digested sludge, and dehydrated sludge) and also in wastewater, as well as in treated (potable) and untreated natural waters. Likewise, the possible effects of the presence of microplastics in a depuration process using an activated sludge biological reactor were evaluated and the distribution of these microparticles in the sludge and in the final effluent. In addition, the possible fragmentation of microplastics into nanoplastics (NPs) in a wastewater treatment system was also considered and, therefore, the possible effects of nanoplastics on the biomass of activated sludge were also evaluated. It was observed that the higher the concentration of organic load in a sample, the more difficult the process of both sample purification and microplastic identification. Therefore, for the sludge samples, it was necessary to apply more complex microplastic extraction protocols. Peroxidation proved to be an effective treatment for all the samples studied, resulting in the reduction of organic matter and the improvement of visual identification. In the tests with the biological reactor, a significant accumulation of microplastics was observed in the mixed liquor (activated sludge) compared to the effluent. This accumulation of microplastics in the sludge can lead to the contamination of agricultural soils when they are applied as fertilizers. To mitigate the contamination of agricultural soils by microplastics present in sludge, the use of the ultrasound technique was proposed for the extraction of these microparticles present in the mixed liquor. Through this technique, significant amounts of microplastics were separated from the organic matrix of the sludge, which is what is applied to the field. Finally, the presence of microfibers in natural and drinking water was studied using the Nile Red staining technique to investigate the feasibility and limitations of this method. It was observed that the fluorescence emission by virgin microfibers and microfibers separated from these water samples can show different fluorescence behaviors which could be related to the degree of degradation of the microfiber materials., Authors thank the Spanish Ministry of Science, Innovation and Universities for the financial support (Reference of the project: RTI2018-096916-B-I00)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Influence of bisphenol A concentration on organic matter removal and nitrification in biological wastewater treatment

  • Mompó-Curell, Raúl|||0000-0002-7837-8025
  • Ferrer-Polonio, Eva|||0000-0001-6412-3825
  • Alonso Molina, José Luís|||0000-0002-2079-910X
  • Mendoza Roca, José Antonio
  • Bes-Piá, M.A.|||0000-0001-8005-7450
[EN] Microplastics and plastic additives have become ubiquitous in our environment, posing a major challenge to wastewater treatment processes. This study investigated the impact of Bisphenol A (BPA), a common plastic additive, on the efficiency of organic matter removal and nitrification in biological wastewater treatment. The obtained results indicated that a BPA concentration of 10¿mg·L¿1 in the influent affected the Chemical Oxygen Demand (COD) in the effluent. In comparison, concentrations of 1 or 5¿mg·L¿1 did not show such noticeable differences. Additionally, an increase in BPA load inhibited the nitrification process, resulting in a high concentration of nitrogen in its ammoniacal form in the effluent when the BPA concentration was increased to 10¿mg·L¿1. In fact, the microbial community analysis revealed a considerable reduction of Nitrosomonas in the reactor fed with wastewater containing 10¿mg·L¿1 of BPA. Despite compromising the nitrification process, this situation did not deprive the biomass of its ability to remove BPA from the system, as this component was not detected in the effluent once the microorganisms completed their adaptation process. 16 S rRNA gene sequencing showed that the predominant phyla across all samples were associated with Proteobacteria, Bacteroidota, Patescibacteria and Actinobacteriota, similar to previous studies., The authors thank the Spanish Ministry of Science, Innovation and Universities for the financial support (Reference of the project: RTI2018-096916-B-I00) . Raul Mompo-Curell particularly thanks Aula Cemex Sostenibilidad (Universitat Politecnica de Valencia) for supporting his Master Thesis Project, included in several of the studies presented.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of polystyrene nanoplastics on the activated sludge process performance and biomass characteristics. A laboratory study with a sequencing batch reactor

  • Alvim, C. Bretas
  • Fernández-Navarro, J.
  • Amorós-Muñoz, I.
  • Ferrer-Polonio, Eva|||0000-0001-6412-3825
  • Bes-Piá, M.A.|||0000-0001-8005-7450
  • Mendoza Roca, José Antonio
  • Alonso Molina, José Luís|||0000-0002-2079-910X
[EN] The fate and presence of nanoplastics in wastewater treatment systems is a topic of increasing interest. Furthermore, challenges related to their quantification and identification have made it difficult to set up experimental conditions and compare results between studies. In this study, the effect of 100 nm polystyrene nanoplastics on activated sludge was evaluated. A concentration of 2 mu g/L was used to continuously feed a sequencing batch reactor (SBR-NPs). Under the experimental conditions used in this study, no changes were observed in the process performance of the SBR-NPs compared to the reactor used as a control. Neither nitri-fication nor organic matter removal efficiency, which was 96% for both SBRs, were affected by the presence of 100 nm polystyrene nanoplastics, which suggests that the tested nanoplastics were not sufficiently toxic to the biomass. Although no significant differences in the relative abundances of predominant phyla between SBR-Control and SBR-NPs were observed, a slight shift in the relative abundance of Patescibacteria (1.5 +/- 0.6% and 3.7 +/- 0.8% in SBR-Control and SBR-NPs, respectively, at the end of the test) occurred. The higher abundance this phylum in SBR-NPs compared to SBR-Control may suggest that these bacteria have some sensitivity to the presence of 100 nm polystyrene nanoplastics. Furthermore, even with the absence of nitrification inhibition, it was observed stagnation of the growth of Nitrotoga bacteria in SBR-NPs, which also suggests that the polystyrene nanoplastics could have an inhibitory effect on these cells and an impact on nitrification in the long term., Authors thank the Spanish Ministry of Science, Innovation and Universities for the financial support (Reference of the project: RTI2018-096916-B-I00).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

An innovative approach to the application of ultrasounds to remove polyethylene microspheres from activated sludge

  • Alvim, Clara
  • Bes-Piá, M.A.|||0000-0001-8005-7450
  • Mendoza Roca, José Antonio
[EN] During the secondary treatment of Wastewater Treatment Plants (WWTP) previous studies have reported that microplastics (MPs), which correspond to plastic fragments smaller than 5 mm, are mostly retained in the activated sludge. Since the sludge can be applied as a fertilizer in agricultural land, the presence of MPs in this matrix can lead to soil contamination. In this study, the application of ultrasounds at a frequency of 80 kHz was tested to remove polyethylene (PE) microspheres from activated sludge samples in order to reduce their concentration in this organic matrix. The application of ultrasounds at a power of 50 W and 8 min 45 sec promoted the removal of 48 ± 4% of MPs from the mixed liquor (2820 ± 51 mg/L of TSS). However, under the same operating conditions, 12 ± 4% of MPs were recovery from the concentrated mixed liquor (9395 ± 164 mg/L of TSS). For the concentrated sludge, a higher power and a longer sonication time (80 kHz; 90 W; 30 min) was necessary to improve the MP recovery. Under these conditions 38 ± 4% of MPs were removed from the sludge. This is the first study applying ultrasounds to remove MPs from activated sludge and the results indicate that ultrasonication can be a suitable instrument in minimizing the concentration of PE microspheres in activated sludge, and thereby minimizing soil contamination when biosolids are applied to agriculture., Authors thank the Spanish Ministry of Science, Innovation and Universities for the financial support (Reference of the project: RTI2018096916-B-I00).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Tesis de maestría (MasterThesis)

Separacion e identificación de microfibras textiles en aguas residuales y potables mediante técnicas de tinción

  • Bretas Alvim, Clara
[ES] El presente Trabajo Fin de Máster tiene como objetivo evaluar el empleo de técnicas de tinción con los reactivos Rosa-Bengala y Rojo Nilo, para la identificación de microfibras (< 5mm) naturales y sintéticas (microplásticos - MPs) en agua potable y en agua residual de una Estación Depuradora de Aguas Residuales (EDAR). De acuerdo con la literatura, el reactivo Rosa-Bengala reacciona con materiales naturales tiñéndolos de rosa. Su aplicación puede ayudar en la identificación de microfibras textiles naturales, como el algodón y la lana. A diferencia del Rosa-Bengala, el reactivo Rojo Nilo tiñe materiales plásticos, aportándoles fluorescencia la cual puede ser observada en un microscopio adecuado. Las microfibras textiles fueron elegidas cómo objeto de estudio porque investigaciones recientes apuntan a estos materiales como los más identificados en la línea de agua de las EDARs y en el agua potable. Con la adopción de técnicas de tinción se pretende evitar el uso de métodos de espectrometría como Raman y el FTIR, los cuales pueden resultar más caros, requieren más tiempo de análisis y formación específica para el manejo de los equipos. Finalmente, con los resultados obtenidos se pretende estimar la contaminación del agua por fibras textiles naturales y MPs. Además, las ventajas, desventajas y limitaciones de las técnicas empleadas serán abordadas y discutidas., [EN] This master's thesis aims to evaluate the use of staining techniques with the Rosa-Bengal and Nile Red reagents, for the identification of natural and synthetic microfibers (<5mm) (microplastics - MPs) in drinking water and in wastewater from a Wastewater Treatment Plant (WWTP). According to the literature, the Rose-Bengal reagent reacts with natural materials staining them pink. Its application can help in the identification of natural textile microfibers, such as cotton and wool. Unlike Rose Bengal, the Nile Red reagent stains plastic materials, providing them with fluorescence which can be observed in a suitable microscope. Textile microfibers were chosen as the object of study because recent research points to these materials as the most identified in the water lines of WWTPs and in drinking water. With the adoption of staining techniques, it is intended to avoid the use of spectrometry methods such as Raman and FTIR, which can be more expensive, require more analysis time and specific training to operate the equipment. Finally, the results obtained are intended to estimate water pollution by natural textile fibers and PMs. In addition, the advantages, disadvantages and limitations of the techniques used will be addressed and discussed.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Assessment of Microplastics Distribution in a Biological Wastewater Treatment

  • Castelluccio, Stefano
  • Alvim, Clara Bretas
  • Fiore, Silvia
  • Bes-Piá, M.A.|||0000-0001-8005-7450
  • Mendoza Roca, José Antonio
[EN] Full-scale wastewater treatment facilities are not able to prevent microplastics (MPs) from discharging into natural waters and they are also associated with the land application of the sludge. This study evaluates the distribution of microfibers (MFs) in a lab-scale sequencing batch reactor (SBR) fed by synthetic wastewater (SW) for 93 days. The MFs were analyzed through optical microscopy in the mixed liquor (ML) and the effluent, and sulfuric acid digestion was applied to discriminate between natural and synthetic MFs (i.e., MPs). The results of the optical microscopy analyses were further validated through FTIR spectroscopy. A model describing the evolution over time of the MF concentration in the ML was created, accounting for the MFs entering the system through the SW and atmospheric deposition. The ratio between the MF concentration in the ML and the effluent was 1409 ± 781, demonstrating that MFs settle with the sludge. Consistently, in the ML, 64.9% of the recovered MFs were smaller than 1000 µm (average size 968 µm), while in the effluent, 76.1% of MFs were smaller than 1000 µm (average size 772 µm). Overall, 72% of MFs recovered from the ML were natural fibers and sulfuric acid digestion was successful in eliminating the natural MFs., This research was funded by the Spanish Ministry of Science, Innovation and Universities (grant number: RTI2018-096916-B-I00).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Advances in analysis of microplastics in drinking water treatment plants. Fluorescence techniques using iDye Pink

  • Alonso-Vázquez, Pablo|||0009-0001-0578-8066
  • Lujan Facundo, Maria Jose|||0000-0001-6871-0584
  • Cuartas Uribe, Beatriz Elena|||0000-0003-2835-900X
  • Bes-Piá, M.A.|||0000-0001-8005-7450
  • Alonso Molina, José Luís|||0000-0002-2079-910X
  • Mendoza Roca, José Antonio
[EN] Recently, the increasing amount of plastic waste has raised concerns about microplastics in aquatic environments. In this study, microplastics between 0.1 and 5 mm in samples from different points of three Drinking Water Treatment Plants (DWTP) were separated, quantified, and identified. Staining methods were used in combination with microscopic and spectroscopic techniques. On the one hand, the Rose Bengal dye was used to discriminate between natural and synthetic particles. On the other hand, Nile Red and iDye Pink reagents have been evaluated for staining microplastics, providing them with fluorescence. The nature of the particles is determined by comparison with a series of patterns by means of an epifluorescence microscope. In addition, "Micro Fourier Transform Spectrophotometer " and "Raman Spectroscopy" were used to identify the nature of the particles more accurately. Concerning the results, polyester was the most common material by fluorescence identification, and it was confirmed with Raman spectroscopy. Since most of the particles observed were microfibres, Raman proved to be a better identification technique than mu-FTIR, which could only identify large fragments. In addition, the global elimination of microplastics (MPs) resulted notable in the three DWTPs, being 81.47% for A, 88.98% for B, and 82.27% for C, thus guaranteeing a higher quality of drinking water., Authors thank to the Spanish Ministry of Science, Innovation and Universities (Reference of the project: RTI 2018 - 096916-B-100) , and Catedra UPV FACSA - FOVASA for the financial support.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Separation and identification of microplastics from primary and secondary effluents and activated sludge from wastewater treatment plants

  • Alvim, C. Bretas
  • Bes-Piá, M.A.|||0000-0001-8005-7450
  • Mendoza Roca, José Antonio
[EN] Although wastewater treatment plants can retain a high percentage of microplastics (MP) arriving at the facilities, no method for extracting and characterizing these microparticles has been still standardized in these units. This study investigated three protocols of chemical digestion, prior to analysis of microplastics, one directed to the effluents, using peroxidation, and two for activated sludge (peroxidation and Fenton). The samples (primary effluent, secondary effluent and activated sludge) were collected from a wastewater treatment plant (WWTP) located in Valencia (Spain). In addition, four common types of polymers (Low density polyethylene-LDPE, Polypropylene-PP, Polystyrene-PS and Polyethylene terephthalate-PET) were used to assess the influence of reagent exposure on microparticle integrity. Peroxidation was effective in treating the studied effluents (primary and secondary) and was also identified as the ideal protocol for activated sludge. The analysis showed that the use of H2O2 does not compromise the identification of the polymers evaluated by FTIR and also significantly reduced the concentration of suspended solids, resulting in an efficient visual separation of the microparticles. After been properly separated, the microparticles were characterized according to their size, colour and shape, and a fraction submitted to identification by mu-ATR-FTIR/ATR-FTIR. In all samples, a high presence of microfibers (MF) was observed, corresponding to more than 90% of the microparticles. However, in relation to secondary effluents, only 9% of these MF were identified as plastics, the remaining ones corresponded to cotton. The fragments found in the samples were classified as secondary in origin, and were mainly PE and PP, lower than 1 mm size., Authors thank the Spanish Ministry of Science, Innovation and Universities for the financial support (Reference of the project: RTI2018-096916-B-I00).
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of polyethylene microplastics on activated sludge process Accumulation in the sludge and influence on the process and on biomass characteristics

  • Alvim, C. Bretas
  • Castelluccio, S.
  • Fernández-Navarro, J.
  • Amoros, Inmaculada
  • Ferrer-Polonio, Eva|||0000-0001-6412-3825
  • Bes-Piá, M.A.|||0000-0001-8005-7450
  • Mendoza Roca, José Antonio
  • Alonso Molina, José Luís|||0000-0002-2079-910X
[EN] According to previous research, it has been proved that wastewater treatment plants (WWTPs) can retain more than 90 % of the MPs contained in wastewater. However, a significant fraction of the MPs removed in WWTPs is retained in the sludge floc and this may lead to an environmental issue since biosolids can be used as fertilizers. The purpose of this research was to evaluate how the presence of polyethylene (PE) could interfere with the activated sludge performance. For this, a sequencing batch reactor (SBR) was continuously fed during 93 days with synthetic sewage and PE microbeads. It was observed that 98 +/- 2% of the total amount of MPs that entered SBR was accumulated in the activated sludge. Despite the high accumulation of MPs in the sludge, the depuration performance of the reactor was not compromised. However, the presence of MPs decreased the richness (Chao1) and abundance-based coverage estimators (ACE) and diversity (Shannon) of the bacterial community on day 93. Based on the analysis of the diversity indices and the relative abundances of microbial taxa, it was concluded that MPs had selective effects on activated sludge microbial community. However, MPs did not affect the abundance of nitrifying and denitrifying bacteria in the sludge., Authors thank the Spanish Ministry of Science, Innovation and Universities for the financial support (Reference of the project: RTI2018-096916-B-I00)
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Effect of 4-nonylphenol on the performance and microbial community of a sequencing batch reactor

  • Ferrer-Polonio, Eva|||0000-0001-6412-3825
  • Mendoza Roca, José Antonio
  • Bes-Piá, M.A.|||0000-0001-8005-7450
  • Alonso Molina, José Luís|||0000-0002-2079-910X
  • Fernández-Navarro, J.
[EN] 4-nonylphenol (4-NP) is one of the most relevant endocrine-disrupting compounds that can be found in wastewaters. In this work, the effect of dosing 1 mg center dot L 1 of 4-NP to simulated wastewater on the activated sludge process was assessed. For it, two laboratory sequencing batch reactors (SBR) were operated for 94 days, adding 1 mg center dot L 1 of 4-NP to the wastewater entering one of them (SBR-NP), while the other one (SBR-B) worked as a control reactor. Holistic study of 4-NP influence on activated sludge treatment was carried out, which included both the evolution of the biomass characteristics and the effect of this substance on reactor performance. Although the COD removal efficiency in SBR-NP was lower than in the reactor without 4-NP addition (SBR-B), COD removal efficiency of SBR-NP was always higher than 90%. From day 50, nitrification bacteria were inhibited in SBR-NP and cellular viability decreased from 85.7 +/- 11.0% in the first 50 days to 63.0 +/- 10.2% in the last 44 days. Concerning the microbial community analysis, both Nitrosomonas and Nitrospira abundances decreased in SBR-NP (from 0.62% to 0.45%, and from 2.39% to 1.01%, respectively). Proteobacteria abundance was considerably higher in SBR-NP at the end of the experiment (44.28% in SBR-NP and 25.88% in SBR-B), which was due to increase of Aquabacterium genus (13.00% and 0.00% in SBR-NP and SBR-B, respectively), playing an important role in 4-NP degradation. Thus, 4-NP presence, in the concentrations studied, affected heterotrophic and autotrophic bacteria differently, having a negative effect in the second group., Acknowledgements Authors thank the Spanish Ministry of Science, Innovation and Universities for the financial support (Reference of the project: RTI2018-096916-B-I00) .