RECUBRIMIENTOS DE BIOMATERIALES DE DOBLE ACCION PARA INFECCIONES BACTERIANAS E INTEGRACION DE TEJIDOS

RTI2018-098075-B-C22

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT INTERNACIONAL DE CATALUNYA,FUNDACIO PRIVADA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 34
Encontrada(s) 1 página(s)

Minerva. Repositorio Institucional de la Universidad de Santiago de Compostela
Publicación Artículo científico (JournalArticle)

Comparison between Sandblasted Acid-Etched and Oxidized Titanium Dental Implants: In Vivo Study

  • Velasco Ortega, Eugenio
  • Ortiz García, Iván
  • Jiménez Guerra, Álvaro
  • Monsalve Guil, Loreto
  • Muñoz Guzón, Fernando María
  • Pérez, Román A.
  • Gil, F. Javier
The surface modifications of titanium dental implants play important roles in the enhancement of osseointegration. The objective of the present study was to test two different implant surface treatments on a rabbit model to investigate the osseointegration. The tested surfaces were: a) acid-etched surface with sandblasting treatment (SA) and b) an oxidized implant surface (OS). The roughness was measured by an interferometeric microscope with white light and the residual stress of the surfaces was measured with X-ray residual stress Bragg–Bentano diffraction. Six New Zealand white rabbits were used for the in vivo study. Implants with the two different surfaces (SA and OS) were inserted in the femoral bone. After 12 weeks of implantation, histological and histomorphometric analyses of the blocks containing the implants and the surrounding bone were performed. All the implants were correctly implanted and no signs of infection were observed. SA and OS surfaces were both surrounded by newly formed trabeculae. Histomorphometric analysis revealed that the bone–implant contact % (BIC) was higher around the SA implants (53.49 ± 8.46) than around the OS implants (50.94 ± 16.42), although there were no significant statistical differences among them. Both implant surfaces (SA and OS) demonstrated a good bone response with significant amounts of newly formed bone along the implant surface after 12 weeks of implantation. These results confirmed the importance of the topography and physico–chemical properties of dental implants in the osseointegration.
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Titanium Surface Characteristics Induce the Specific Reprogramming of Toll-like Receptor Signaling in Macrophages

  • González-Sánchez, Zaida
  • Areal-Quecuty, Victoria
  • Jimenez-Guerra, Alvaro
  • Cabanillas-Balsera, Daniel
  • Gil, Francisco Javier
  • Velasco-Ortega, Eugenio
  • Pozo, David
Most of the research on titanium-based dental implants (Ti-discs) is focused on how they are able to stimulate the formation of new tissue and/or cytotoxic studies, with very scarce data on their effects on functional responses by immunocompetent cells. In particular, the link between the rewiring of innate immune responses and surface biomaterials properties is poorly understood. To address this, we characterize the functional response of macrophage cultures to four different dental titanium surfaces (MA: mechanical abrasion; SB + AE: sandblasting plus etching; SB: sandblasting; AE: acid etching). We use different Toll-like receptor (TLR) ligands towards cell surface receptors (bacterial lipopolysaccharide LPS for TLR4; imiquimod for TLR7; synthetic bacterial triacylated lipoprotein for TLR2/TLR1) and endosomal membrane receptor (poly I:C for TLR3) to simulate bacterial (cell wall bacterial components) or viral infections (dsRNA and ssRNA). The extracellular and total LDH levels indicate that exposure to the different Ti-surfaces is not cytotoxic for macrophages under resting or TLR-stimulated conditions, although there is a tendency towards an impairment in macrophage proliferation, viability or adhesion under TLR4, TLR3 and TLR2/1 stimulations in SB discs cultures. The secreted IL-6 and IL-10 levels are not modified upon resting macrophage exposure to the Ti-surfaces studied as well as steady state levels of iNos or ArgI mRNA. However, macrophage exposure to MA Ti-surface do display an enhanced immune response to TLR4, TLR7 or TLR2/1 compared to other Ti-surfaces in terms of soluble immune mediators secreted and M1/M2 gene expression profiling. This change of characteristics in cellular phenotype might be related to changes in cellular morphology. Remarkably, the gene expression of Tlr3 is the only TLR that is differentially affected by distinct Ti-surface exposure. These results highlight the relevance of patterned substrates in dental implants to achieve a smart manipulation of the immune responses in the context of personalized medicine, cell-based therapies, preferential lineage commitment of precursor cells or control of tissue architecture in oral biology., This research was funded by the Regional Ministry of Transformación Económica, Industria, Conocimiento y Universidades (PAID2020, CTS677 to D.P.), the Catedra de Investigación Galimplant de Implantología Oral de la Universidad de Sevilla (3795-0116 to E.V.-O.) and the Spanish Goverment Ministry of Science and Innovation of Spain (RTI2018-098075-B-C22 to F.J.G and RTI2018-098432-BI00 to D.P.), co-funded by the European Regional Development Fund (ERDF), a way to build Europe
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Osteoblastic cell behavior and gene expression related to bone metabolism on different titanium surfaces

  • Velasco-Ortega, Eugenio
  • Fos-Parra, Isabel
  • Cabanillas-Balsera, Daniel
  • Gil, FJ
  • Ortiz-García, Iván
  • Giner, Mercè
  • Bocio-Núñez, Jesús
  • Montoya-García, María-José
  • Jiménez-Guerra, Álvaro
The work was supported by the Spanish Government and the Ministry of Science and Innovation of Spain by research projects RTI2018-098075-B-C21 and RTI2018-098075-B-C22 (co-funded by the European Regional Development Fund (ERDF), a way to build Europe). Catedra de investigacion en implantologia oral de la Universidad de Sevilla-Galimplant., The surface topography of titanium dental implants has a great influence on osseointegration. In this work, we try to determine the osteoblastic behavior and gene expression of cells with different titanium surfaces and relate them to the physicochemical properties of the surface. For this purpose, we have used commercial titanium discs of grade 3: as-received corresponds to machined titanium without any surface treatment (MA), chemically acid etched (AE), treated via sand blasting with Al2O3 particles (SB) and a sand-blasting treatment with acid etching (SB+AE). The surfaces have been observed using scanning electron microscopy (SEM) and the roughness, wettability and surface energy with dispersive and polar components have been characterized. Osteoblastic cultures were performed with SaOS-2 osteoblastic cells determining cell viability as well as alkaline phosphatase levels for 3 and 21 days, and osteoblastic gene expression was determined. The roughness values of the MA discs was 0.02 μm, which increases to 0.3 μm with acid attack and becomes the maximum for the sand-blasted samples, reaching values of 1.2 μm for SB and SB+AE. The hydrophilic behavior of the MA and AE samples with contact angles of 63° and 65° is superior to that of the rougher samples, being 75° for SB and 82° for SB+AE. In all cases, they show good hydrophilicity. GB and GB+AE surfaces present a higher polar component in the surface energy values, 11.96 and 13.18 mJ/m2, respectively, than AE and MA, 6.64 and 9.79 mJ/m2, respectively. The osteoblastic cell viability values at three days do not show statistically significant differences between the four surfaces. However, the viability of the SB and SB+AE surfaces at 21 days is much higher than that of the AE and MA samples. From the alkaline phosphatase studies, higher values were observed for those treated with sand blasting with and without acid etching compared to the other two surfaces, indicating a greater activity in osteoblastic differentiation. In all cases except in the Osterix (Ostx) —osteoblast-specific transcription factor—a decrease in gene expression is observed in relation to the MA samples (control). The most important increase was observed for the SB+AE condition. A decrease in the gene expression of Osteoprotegerine (OPG), Runt-related transcription factor 2 (Runx2), Receptor Activator of NF-κB Ligand (RANKL) and Alkaline Phosphatase (Alp) genes was observed in the AE surface., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Effect of fluoride content of mouthwashes on superelastic properties of NiTi orthodontic archwires

  • Pastor, Francisco
  • Rodríguez, Juan Carlos
  • Barrera, José María
  • Delgado García-Menocal, José Angel
  • Brizuela, Aritza
  • Puigdollers, Andreu
  • Espinar, Eduardo
  • Gil, FJ
The work was supported by the Spanish Government and the Ministry of Science and Innovation of Spain by research projects RTI2018-098075-B-C21 and RTI2018-098075-B-C22 (co-funded by the European Regional Development Fund (ERDF). A way to build Europe)., The influence of sodium fluoride (NaF) concentration in mouthwashes on the properties of superelastic NiTi orthodontic wires has been studied. In this work, 55.8%Ni and 44.2%Ti (in weight) wires were introduced in commercial mouthwashes with different NaF contents (0, 130, 200 and 380 ppm). The release of Ni2+ and Ti4+ ions was by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) at 1, 4, 7 and 14 days. Superelastic orthodontic wires present at oral temperature the austenitic phase which is transformed into a plastic phase (martensite) by cooling. The temperatures at which this occurs are influenced by the chemical composition. The release of ions from the wire will produce variations in the temperatures and stresses of the stress-induced martensitic transformation. Ms, Mf, As, Af were determined by Differential Scanning Calorimeter (DSC). The transformation stresses (austenite to stress induce martensite) were determined with a servo-hydraulic testing machine at 37 °C. The surfaces for the different times and mouthwash were observed by Scanning Electron Microscope (SEM). The release of Ni2+ in mouthwashes with 380 ppm NaF concentrations reaches 230,000 ppb in 14 days and for Ti4+ 175,000 ppb. When NaF concentrations are lower than 200 ppm the release of Ni and Ti ions is around 1500 ppb after 14 days. This variation in compositions leads to variations in Ms from 27 °C to 43.5 °C in the case of higher NaF concentration. The increasing immersion time and NaF concentrations produce a decrease of Ni in the wires, increasing Ms which exceed 37 °C with the loss of superelasticity. In the same way, the stresses (tooth position corrective) decrease from 270 MPa to 0 MPa due to the martensitic phase. The degradation can produce the growth of precipitates rich in Ti (Ti2Ni). These results are of great interest in the orthodontic clinic in order to avoid the loss of the therapeutic properties of superelastic NiTi due to long immersion in fluoride mouthwashes., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Titanium surface characteristics induce the specific reprogramming of toll-like receptor signaling in macrophages

  • González-Sánchez, Zaira
  • Areal-Quecuty, Victoria
  • Jimenez-Guerra, Alvaro
  • Cabanillas-Balsera, Daniel
  • Gil, FJ
  • Velasco-Ortega, Eugenio
  • Pozo Perez, David
This research was funded by the Regional Ministry of Transformación Económica, Industria, Conocimiento y Universidades (PAID2020, CTS677 to D.P.), the Catedra de Investigación Galimplant de Implantología Oral de la Universidad de Sevilla (3795-0116 to E.V.-O.) and the Spanish Goverment Ministry of Science and Innovation of Spain (RTI2018-098075-B-C22 to F.J.G and RTI2018-098432-BI00 to D.P.), co-funded by the European Regional Development Fund (ERDF), a way to build Europe., Most of the research on titanium-based dental implants (Ti-discs) is focused on how they are able to stimulate the formation of new tissue and/or cytotoxic studies, with very scarce data on their effects on functional responses by immunocompetent cells. In particular, the link between the rewiring of innate immune responses and surface biomaterials properties is poorly understood. To address this, we characterize the functional response of macrophage cultures to four different dental titanium surfaces (MA: mechanical abrasion; SB + AE: sandblasting plus etching; SB: sandblasting; AE: acid etching). We use different Toll-like receptor (TLR) ligands towards cell surface receptors (bacterial lipopolysaccharide LPS for TLR4; imiquimod for TLR7; synthetic bacterial triacylated lipoprotein for TLR2/TLR1) and endosomal membrane receptor (poly I:C for TLR3) to simulate bacterial (cell wall bacterial components) or viral infections (dsRNA and ssRNA). The extracellular and total LDH levels indicate that exposure to the different Ti-surfaces is not cytotoxic for macrophages under resting or TLR-stimulated conditions, although there is a tendency towards an impairment in macrophage proliferation, viability or adhesion under TLR4, TLR3 and TLR2/1 stimulations in SB discs cultures. The secreted IL-6 and IL-10 levels are not modified upon resting macrophage exposure to the Ti-surfaces studied as well as steady state levels of iNos or ArgI mRNA. However, macrophage exposure to MA Ti-surface do display an enhanced immune response to TLR4, TLR7 or TLR2/1 compared to other Ti-surfaces in terms of soluble immune mediators secreted and M1/M2 gene expression profiling. This change of characteristics in cellular phenotype might be related to changes in cellular morphology. Remarkably, the gene expression of Tlr3 is the only TLR that is differentially affected by distinct Ti-surface exposure. These results highlight the relevance of patterned substrates in dental implants to achieve a smart manipulation of the immune responses in the context of personalized medicine, cell-based therapies, preferential lineage commitment of precursor cells or control of tissue architecture in oral biology., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Mechanical properties of CoCr dental-prosthesis restorations made by three manufacturing processes: influence of the microstructure and topography

  • Padrós, Roberto
  • Punset fuste, Miquel
  • Molmeneu, Meritxell
  • Brizuela Velasco, Aritza
  • Herrero-Climent, Mariano
  • Rupérez de Gracia, Elisa
  • Gil, FJ
The work was supported by the Spanish government and the Ministry of Science and Innovation number RTI2018-098075-B-C21 and RTI2018-098075-B-C22, cofounded by the EU through the European Regional Development Funds (MINECO-FEDER, EU). Authors also acknowledge Generalitat de Catalunya for the funding through 2017SGR-1165 project., The aim of this study is to compare the mechanical properties of three different dental restorations’ manufacturing processes (CADCAM milling, casting and laser sintering) generated by only one laboratory scanner focusing on marginal fit analysis and their mechanical properties. A chrome-cobalt (Cr-Co) alloy from the same batch was used for three different methods to make an implant abutment. This simulates a maxillary right first molar that was fixed in a hemi-maxillary stone model. Five scans were performed by each tested framework. Nine frameworks were manufactured for each manufacture procedure. Field-Emission Scanning Electron Microscope (FE-SEM) direct vision was used to marginal gap measurement in five critical points for each specimen. In order to fix the samples in the microscope chamber, the restorations were submitted at a compression load of 50 N. The samples always have the same orientation and conditions. The resolution of the microscope is 4 nm and it is equipped by J image software. The microstructure of the samples was also determined with the FE-SEM equipped with EDS-microanalysis. Roughness parameters were measured using White Light Interferometry (WLI). The arithmetical mean for the Ra and Rq of each sample was calculated. The samples were mechanically characterized by means of microhardness and flexural testing. Servo-hydraulic testing machine was used with cross-head rate of 1 mm/min. Two-way ANOVA statistical analysis was performed to determine whether the marginal discrepancies and mechanical properties were significantly different between each group (significance level p < 0.05). The overall mean marginal gap values were: from 50.53 ± 10.30 µm for the samples produced by CADCAM to 85.76 ± 22.56 µm for the samples produced by the casting method. Laser sintering presents a marginal gap of 60.95 ± 20.66 µm. The results revealed a statistically significant difference (p-value < 0.005) in the mean marginal gap between the CADCAM systems studied. The higher flexure load to fracture for these restorations were for CADCAM restoration and the lower was for the casting samples. For these restorations, CADCAM Restoration yielded a higher flexure load to fracture and Casting ones yielded the lower. Porosity and microstructure play a very important role in the mechanical properties., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Relevant aspects of titanium topography for osteoblastic adhesion and inhibition of bacterial colonization

  • Rodriguez González, Raquel
  • Monsalve-Guil, Loreto
  • Jimenez-Guerra, Alvaro
  • Velasco-Ortega, Eugenio
  • Moreno Muñoz, Jesús
  • Nuñez-Marquez, Enrique
  • Perez, Roman
  • Gil, FJ
  • Ortiz-Garcia, Ivan
The work was supported by the Spanish Government and the Ministry of Science and Innovation of Spain by research projects RTI2018-098075-B-C21 and RTI2018-098075-B-C22 (cofounded by the European Regional Development Fund (ERDF), a way to build Europe)., The influence of the surface topography of dental implants has been studied to optimize titanium surfaces in order to improve osseointegration. Different techniques can be used to obtain rough titanium, however, their effect on wettability, surface energy, as well as bacterial and cell adhesion and differentiation has not been studied deeply. Two-hundred disks made of grade 4 titanium were subjected to different treatments: machined titanium (MACH), acid-attacked titanium (AE), titanium sprayed with abrasive alumina particles under pressure (GBLAST), and titanium that has been treated with GBLAST and then subjected to AE (GBLAST + AE). The roughness of the different treatments was determined by confocal microscopy, and the wettability was determined by the sessile drop technique; then, the surface energy of each treatment was calculated. Osteoblast-like cells (SaOs-2) were cultured, and alkaline phosphatase was determined using a colorimetric test. Likewise, bacterial strains S. gordonii, S. oralis, A. viscosus, and E. faecalis were cultured, and proliferation on the different surfaces was determined. It could be observed that the roughness of the GBLAST and GBLAS + AE was higher, at 1.99 and 2.13 μm of Ra, with respect to the AE and MACH samples, which were 0.35 and 0.20 μm, respectively. The abrasive treated surfaces showed lower hydrophilicity but lower surface energy. Significant differences could be seen at 21 days between SaOS-2 osteoblastic cell adhesion for the blasted ones and higher osteocalcin levels. However, no significant differences in terms of bacterial proliferation were observed between the four surfaces studied, demonstrating the insensitivity of bacteria to topography. These results may help in the search for the best topographies for osteoblast behavior and for the inhibition of bacterial colonization., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

On-growth and In-growth osseointegration enhancement in PM porous Ti-scaffolds by two different bioactivation strategies: alkali thermochemical treatment and RGD Ppeptide coating

  • Rappe, Katrin Steffanie
  • Ortiz, Monica
  • Punset fuste, Miquel
  • Molmeneu, Meritxell
  • Barba, Albert
  • Mas-Moruno, Carlos
  • Guillem-Marti, Jordi
  • Caparrós, Cristina
  • Ruperez, Elisa
  • Calero, José
  • Manzanares Céspedes, Maria Cristina
  • Gil, FJ
  • Franch, Jordi
This research was funded by Spanish Government, grant number RTI2018-098075-B-C21, RTI2018-098075-BC22 and PID2020-114019RB-I00/AEI/10.13039/501100011033., A lack of primary stability and osteointegration in metallic implants may result in implant loosening and failure. Adding porosity to metallic implants reduces the stress shielding effect and improves implant performance, allowing the surrounding bone tissue to grow into the scaffold. However, a bioactive surface is needed to stimulate implant osteointegration and improve mechanical stability. In this study, porous titanium implants were produced via powder sintering to create different porous diameters and open interconnectivity. Two strategies were used to generate a bioactive surface on the metallic foams: (1) an inorganic alkali thermochemical treatment, (2) grafting a cell adhesive tripeptide (RGD). RGD peptides exhibit an affinity for integrins expressed by osteoblasts, and have been reported to improve osteoblast adhesion, whereas the thermochemical treatment is known to improve titanium implant osseointegration upon implantation. Bioactivated scaffolds and control samples were implanted into the tibiae of rabbits to analyze the effect of these two strategies in vivo regarding bone tissue regeneration through interconnected porosity. Histomorphometric evaluation was performed at 4 and 12 weeks after implantation. Bone-to-implant contact (BIC) and bone in-growth and on-growth were evaluated in different regions of interest (ROIs) inside and outside the implant. The results of this study show that after a long-term postoperative period, the RGD-coated samples presented higher quantification values of quantified newly formed bone tissue in the implant’s outer area. However, the total analyzed bone in-growth was observed to be slightly greater in the scaffolds treated with alkali thermochemical treatment. These results suggest that both strategies contribute to enhancing porous metallic implant stability and osteointegration, and a combination of both strategies might be worth pursuing., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Benefits of residual aluminum oxide for sand blasting titanium dental implants: osseointegration and bactericidal effects

  • Gil, FJ
  • Pérez Antoñanzas, Román
  • Herrero-Climent, Mariano
  • Rizo-Gorrita, María
  • Torres-Lagares, Daniel
  • Gutierrez, Jose Luis
The authors would like to thank SOADCO (Escaldes-Engordany, Andorra) for the financial support provided. This research was funded by Spanish Government and European Union FEDER by the concession of the grant RTI2018-098075-B-C22, the Spanish Government by the Ramón y Cajal Program (RYC2018-025977-I) and the research group Generalitat de Catalunya 2017SGR708., Objectives. The purpose of this work was to determine the influence of residual alumina after sand blasting treatment in titanium dental implants. This paper studied the effect of alumina on physico-chemical surface properties, such as: surface wettability, surface energy. Osseointegration and bacteria adhesion were determined in order to determine the effect of the abrasive particles. Materials and Methods. Three surfaces were studied: (1) as-received, (2) rough surface with residual alumina from sand blasting on the surface and (3) with the same roughness but without residual alumina. Roughness was determined by white light interferometer microscopy. Surface wettability was evaluated with a contact angle video-based system and the surface free energy by means of Owens and Wendt equation. Scanning electron microscopy equipped with microanalysis was used to study the morphology and determine the chemical composition of the surfaces. Bacteria (Lactobacillus salivarius and Streptococcus sanguinis) were cultured in each surface. In total, 110 dental implants were placed into the bone of eight minipigs in order to compare the osseointegration. The percentage of bone-to-implant contact was determined after 4 and 6 weeks of implantation with histometric analysis. Results. The surfaces with residual alumina presented a lower surface free energy than clean surfaces. The in vivo studies demonstrated that the residual alumina accelerated bone tissue growth at different implantation times, in relation to clean dental implants. In addition, residual alumina showed a bactericidal effect by decreasing the quantity of bacteria adhering to the titanium. Conclusions. It is possible to verify the benefits that the alumina (percentages around 8% in weight) produces on the surface of titanium dental implants. Clinical relevance. Clinicians should be aware of the benefits of sand-blasted alumina due to the physico-chemical surface changes demonstrated in in vivo tests., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Influence of implant design and under-preparation of the implant site on implant primary stability: an In vitro study

  • Herrero-Climent, Mariano
  • Ferreira de Lemos, Bernardo
  • Herrero-Climent, Mariano
  • Falcao-Costa, Carlos
  • Oliveira, Hélder Line
  • Herrera, Manuela
  • Gil, FJ
  • RÍOS-CARRASCO, BLANCA
  • Ríos-Santos, José-Vicente
The work was supported by the Spanish government and the Ministry of Science and Innovation of Spain by the research project number RTI2018-098075-B-C21 and RTI2018-098075-B-C22, cofounded by the EU through the European Regional Development Funds (MINECO-FEDER, EU)., The aim of this study was to evaluate the effects of different implant sites an under-preparation sequence associated with two different implant designs on implant primary stability measured by two parameters: insertion torque (IT) and implant stability quotient (ISQ). It used two different implants: one cylindrical as a control and another one with a tapered design. The implants were inserted in type III fresh humid bovine bone and four drilling sequences were used: one control, the one proposed by the implant company (P1), and three different undersized (P2, P3 and P4). P2 was the same as P1 without the cortical drill, P3 was without the last pilot drill and P4 was without both of them. The sample size was n = 40 for each of the eight groups. Final IT was measured with a torquemeter and the ISQ was measured with Penguin resonance frequency analysis. Results showed that both ISQ and IT have a tendency to increase as the preparation technique reduces the implant site diameter when compared with the standard preparation, P1. The preparations without cortical drill, P2 and P4, showed the best results when compared with the ones with a cortical drill. Tapered implants always showed higher or the same ISQ and IT values when compared with the cylindrical implants. Giving the limitations of this study, it can be concluded that reducing implant preparation can increase IT and ISQ values. Removing the cortical drill and the use of a tapered design implant are also effective methods of increasing primary implant stability., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Fracture and fatigue of titanium narrow dental implants: new trends in order to improve the mechanical response

  • Velasco-Ortega, Eugenio
  • Flichy-Fernández, Antonio
  • Punset fuste, Miquel
  • Jiménez-Guerra, Alvaro
  • Manero, José María
  • Gil, FJ
The authors kindly acknowledge the collaboration of many individuals and institutons in the present manuscript. The authors are grateful to the Spanish Government and European Union FEDER for concession of the project RTI2018-098075-B-C22., Sixty-four fractured commercially pure titanium (cp-Ti) narrow dental implants (NDIs) with similar macrogeometry and connection designs were studied after different implantation times in humans in order to determine their reliability and to evaluate the causes of the fracture. These NDIs were compared with other similar implants, made with alloyed titanium with 15% Zr and with 12% strained titanium. Original implants were tested under static and fatigue conditions, simulating the tri-axial loads in the mouth by means of a Bionix hydraulic test machine. Fractography was studied using field-emission scanning electron microscopy (FSEM). The results showed that cp-Ti NDI exhibits low strength for mechanical cycling, and the alloyed Ti and strained titanium increase the mechanical strength, guaranteeing long term mechanical behavior. NDIs fractured due to fatigue, and, in some cases, the presence of cracks in the original NDIs quickly led to fracture. These cracks were attributed to plastic deformation during machining were found to be exacerbated due to acid etching in the passivation process. All cases of fracture were cp-Ti dental implants due to the low fatigue limit. The results show that, when titanium is alloyed or cold-worked, the fatigue limit is higher than cp-Ti. This in vitro research will help clinicians to select a better NDI system for safer treatment., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Effect of fluoride content of mouthwashes on the metallic ion release in different orthodontics archwires

  • Pastor, Francisco
  • Rodríguez Fernández, Juan Carlos
  • Barrera, José María
  • Delgado García-Menocal, José Angel
  • Brizuela, Aritza
  • Puigdollers, Andreu
  • Espinar, Eduardo
  • Gil, FJ
The work was supported by the Spanish Government and the Ministry of Science and Innovation of Spain by research projects RTI2018-098075-B-C21 and RTI2018-098075-B-C22 (co-funded by the European Regional Development Fund (ERDF), a way to build Europe)., Metal ion release studies were carried out on three of the most commonly used orthodontic wires in the clinic: austenitic stainless steel, Ti-Mo, and superelastic NiTi, using three mouthwashes with different fluoride concentrations: 130, 200, and 380 ppm. Immersions were carried out in these mouthwashes at 37 °C for 1, 4, 7, and 14 days, and the ions released were determined by inductively coupled plasma-mass spectrometry (ICP-MS). All wires were observed by scanning electron microscopy (SEM). The results showed a moderate ion release in the stainless steel wires, with nickel and chromium values of 500 and 1000 ppb in the worst conditions for the wires: concentrations of 380 ppm fluoride and 14 days of immersion. However, in the Ti-Mo and NiTi alloys, an abrupt change in release was observed when the samples were immersed in 380 ppm fluoride concentrations. Titanium releases in Ti-Mo wires reached 200,000 ppb, creating numerous pits on the surface. Under the same conditions, the release of Ni and Ti ions from the superelastic wires also exceeded 220,000 ppb and 180,000 ppb, respectively. This release of ions causes variations in the chemical composition of the wires, causing the appearance of martensite plates in the austenitic matrix after 4 days of immersion. This fact causes it to lose its superelastic properties at a temperature of 37 °C. In the case of immersion in 380 ppm mouthwashes for more than 7 days, rich-nickel precipitates can be seen. These embrittle the wire and lose all tooth-correcting properties. It should be noted that the release of Ni ions can cause hypersensitivity in patients, particularly women. The results indicate that the use of mouthwashes with a high content of fluoride should not be recommended with orthodontic archwires., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Citric acid in the passivation of titanium dental implants: corrosion resistance and bactericide behavior

  • Verdeguer, Pablo
  • Gil Mur, Francisco Javier
  • Punset fuste, Miquel
  • Manero, José María
  • Nart, Jose
  • Vilarrasa, Javi
  • Ruperez, Elisa
The work was supported by the Spanish government and the Ministry of Science and Innovation of Spain by the research project numbers RTI2018-098075-B-C21 and RTI2018-098075-BC22, cofounded by the EU through the European Regional Development Funds (MINECO-FEDER, EU). Authors also acknowledge Generalitat de Catalunya for funding through the 2017SGR-1165 project and the 2017SGR708 project., The passivation of titanium dental implants is performed in order to clean the surface and obtain a thin layer of protective oxide (TiO2) on the surface of the material in order to improve its behavior against corrosion and prevent the release of ions into the physiological environment. The most common chemical agent for the passivation process is hydrochloric acid (HCl), and in this work we intend to determine the capacity of citric acid as a passivating and bactericidal agent. Discs of commercially pure titanium (c.p.Ti) grade 4 were used with different treatments: control (Ctr), passivated by HCl, passivated by citric acid at 20% at different immersion times (20, 30, and 40 min) and a higher concentration of citric acid (40%) for 20 min. Physical-chemical characterization of all of the treated surfaces has been carried out by scanning electronic microscopy (SEM), confocal microscopy, and the ‘Sessile Drop’ technique in order to obtain information about different parameters (topography, elemental composition, roughness, wettability, and surface energy) that are relevant to understand the biological response of the material. In order to evaluate the corrosion behavior of the different treatments under physiological conditions, open circuit potential and potentiodynamic tests have been carried out. Additionally, ion release tests were realized by means of ICP-MS. The antibacterial behavior has been evaluated by performing bacterial adhesion tests, in which two strains have been used: Pseudomonas aeruginosa (Gram–) and Streptococcus sanguinis (Gram+). After the adhesion test, a bacterial viability study has been carried out (‘Life and Death’) and the number of colony-forming units has been calculated with SEM images. The results obtained show that the passivation with citric acid improves the hydrophilic character, corrosion resistance, and presents a bactericide character in comparison with the HCl treatment. The increasing of citric acid concentration improves the bactericide effect but decreases the corrosion resistance parameters. Ion release levels at high citric acid concentrations increase very significantly. The effect of the immersion times studied do not present an effect on the properties., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Influence of connection type and platform diameter on titanium dental implants fatigue: non-axial loading cyclic test analysis

  • Nicolas-Silvente, Ana Isabel
  • Velasco-Ortega, Eugenio
  • Ortiz-Garcia, Iván
  • Jiménez Guerra, Álvaro
  • Monsalve-Guil, Loreto
  • Ayuso-Montero, Raul
  • Gil, FJ
  • Lopez-Lopez, Jose
The authors acknowledge the Spanish Government for financial support through a Ramon y Cajal grant of C.M.M. (RYC-2015-18566) and projects RTI2018-098075-B-C21, RTI2018-098075-B-C22, and MAT2017-83905-R, cofounded by the EU through the European Regional Development Funds (MINECO-FEDER, EU)., Two-pieces dental implants must provide stability of the implant-abutment-interface. The connection type and platform diameter could influence the biomechanical resistance and stress distribution. This study aims to evaluate the fatigue for different types of connections, external and internal, and different platform diameters. Three implant designs with the same length were used: (a) external hexagon/narrow platform; (b) internal double hexagon/narrow platform; (c) internal octagon/regular platform. A fatigue test was developed to establish the number of cycles needed before fracture. A 30º oblique load with a sinusoidal function of fatigue at a frequency of 15 Hz and 10% stress variation was applied to each system. The fatigue load limit (FLL) for design (a) was 190 N, being the nominal-curvature-moment (NCM) = 1.045; FLL = 150 N, with a NCM = 0.825 for (b), and FLL = 325 N, with a NCM = 1.788 for (c). The platform diameter affects the FLL, obtaining lower FLL on a narrow platform. The connection type interferes with the implant walls’ width, especially in narrow implants, making internal connections more unstable at this level. Long-term clinical studies to assess the restoration’s success rate and survival are mandatory., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Influence of the CAD-CAM systems on the marginal accuracy and mechanical properties of dental restorations

  • Padrós, Roberto
  • Giner-Tarrida, Luis
  • Herrero-Climent, Mariano
  • Falcao-Costa, Carlos
  • Ríos-Santos, José-Vicente
  • Gil, FJ
The work was supported by the Spanish government. Ministerio Economía y Competitividad and FEDER (UE) by the research project number RTI2018-098075-B-C22., The aim of this study was to compare the quality of different computer-assisted-design and computer assisted manufacturing systems (CAD-CAM) generated by only one scanner, focusing on vertical fit discrepancies and the mechanical properties. A master model was obtained from a real clinical situation: the replacement of an absent (pontic) tooth, with the construction of a fixed partial denture on natural abutments with three elements. Nine scans were performed by each tested and 36 copies were designed using a dental CAD-CAM software (Exocad). The frameworks were manufactured using three-axis and five-axis, with the same batch of the chrome-cobalt (CrCo) alloy. The frameworks were not cemented. A focus ion beam-high resolution scanning electron microscope (FIB-HRSEM) allowed us to obtain the vertical gap measurements in five points for each specimen. Roughness parameters were measured using white light interferometry (WLI). The samples were mechanically characterized by means of flexural tests. A servo-hydraulic testing machine was used with a cross-head rate of 1 mm/min. One-way ANOVA statistical analysis was performed to determine whether the vertical discrepancies and mechanical properties were significantly different between each group (significance level p < 0.05). The overall mean marginal gap values ranged: from 92.38 ± 19.24 µm to 19.46 ± 10.20 µm, for the samples produced by three-axis and five-axis machines, respectively. Roughness was lower in the five-axis machine than the three-axis one, and as a consequence, the surface quality was better when the five-axis machine was used. These results revealed a statistically significant difference (p < 0.005) in the mean marginal gap between the CAD-CAM systems studied. The flexural strength for these restorations range from 6500 to 7000 N, and does not present any statistical differences’ significance between two CAD-CAM systems studied. This contribution suggests that the number of axes improves vertical fit and surface quality due to the lower roughness. These claims show some discrepancies with other studies., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

New bactericide orthodonthic archwire: NiTi with silver nanoparticles

  • Gil, FJ
  • Espinar Escalona, Eduardo
  • Clusellas, Núria
  • Fernandez-Bozal, Javier
  • Artes Ribas, Montserrat
  • Puigdollers, Andreu
This research was funded by Spanish Government and and European Union FEDER by the concession of the grant RTI2018-098075-B-C22 and the research group Generalitat de Catalunya 2017SGR708., A potential new bactericide treatment for NiTi orthodontic archwires based in the electrodeposition of silver nanoparticles on the surface was studied. Twenty-five archwires were treated by electrodeposition, obtaining nanoparticles of silver embedded on the archwire surface. These were evaluated in order to investigate the possible changes on the superelastic characteristics (critical temperatures and stresses), the nickel ion release, and the bacteria culture behavior. The chemical composition was analyzed by Energy Dispersive X-Ray Spectroscopy-microanalysis; the singular temperatures of the martensitic transformation were obtained by a flow calorimeter. Induced martensitic transformation stresses were obtained by mechanical testing apparatus. Nickel ion release was analyzed by inductively coupled plasma-mass spectrometry (ICP-MS) equipment using artificial saliva solution at 37 °C. Bacterial tests were studied with the most used oral bacterial strains: Streptococcus sanguinis and Lactobacillus salivarius. NiTi samples were immersed in bacterial suspensions for 2 h at 37 °C. Adhered bacteria were separated and seeded on agar plates: Tood-Hewitt (TH) and Man-Rogosa-Sharpe (MRS) for S. sanguinis and for L.salivarius, respectively. These were then incubated at 37 °C for 1 day and the colonies were analyzed. The results showed that the transformation temperatures and the critical stresses have not statistically significant differences. Likewise, nickel ion release at different immersion times in saliva at 37 °C does not present changes between the original and treated with silver nanoparticles archwires. Bacteria culture results showed that the reduction of the bacteria due to the presence to the nanoparticles of silver is higher than 90%. Consequently, the new treatment with nanoparticles of silver could be a good candidate as bactericidic orthodontic archwire., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

"In vitro" study about variables that influence in arch friction with conventional and self-ligating brackets

  • Moyano Lleixà, Javier
  • Mases, Laia
  • Izeta, Telmo
  • Flores, Teresa
  • Fernandez-Bozal, Javier
  • Gil, FJ
  • Puigdollers, Andreu
This article belongs to the Special Issue Orthodontic Materials and Adhesive Interfaces, The authors are grateful to the Spanish Government and the European Union FEDER for the concession of the project RTI2018-098075-B-C22., Many advantages have been described surrounding self-ligating (SL) brackets compared to metallic conventional ligating (CL) brackets, such as: Less total treatment time, alignment efficiency, patient comfort, plaque retention, and low friction. The objective of this in vitro simulation was to know the variables that affect arch displacement in CL and SL brackets—active (ASL) and passive (PSL)—and analyze if static friction values are affected by bracket design, arch wire section, kind of ligature, and use of a friction reducer agent (FRA) in a wet state. Larger values of static friction were found in CL with metallic ligature (ML) (8.01 ± 1.08 N/mm) and elastic ligature (EL) (6.96 ± 0.48 N/mm). Lower values were found in PSL brackets combined with FRA (0.58 ± 0.21 N/mm). The study was carried out using different stereographical models of a maxillary upper right quadrant with canine, first and second premolar, and first molar bonded brackets. A section of 25 mm of 0.019 × 0.025” stainless steel arch with a rectangular section (SS) and hybrid section (HY) was inserted into the different bracket models. Static friction values were collected using a universal test machine in wet conditions and testing the effect of a friction reducer agent (FRA). To assure the reliability of the study, different wire combinations were repeated after two weeks by the same operator and a linear analysis of regression was done. Each bracket model analysis—with the different wires, use of the FRA, and comparison among brackets in similar conditions—was done using an ANOVA test with a confidence interval of 95% and comparative Post-Hoc tests (LSD). In this in vitro simulation we found higher static friction values in CL compared to ASL and PSL. In PSL, lower values were achieved. CL brackets using ML showed the highest static friction values with a great variability. In this setting, the use of HY wires did not reduce static friction values in ASL and PSL, while in CL brackets with EL friction the values were reduced significantly. An FRA combined with ASL reduced significantly static friction values but not with PSL. In the case of CL, the FRA effect was higher with SS and better than with HY wires. ML values were similar to ASL static friction. The direct extrapolation of the results might be inaccurate, since all these findings should be tested clinically to be validated., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Influence of bone-level dental implants placement and of cortical thickness on osseointegration: in silico and In vivo analyses

  • Gil, FJ
  • Sandino, Clara
  • Cerrolaza, Miguel
  • Pérez, Román
  • Herrero-Climent, Mariano
  • RÍOS-CARRASCO, BLANCA
  • Rios-Santos, Jose Vicente
  • Brizuela Velasco, Aritza
The authors would like to thank SOADCO (Escaldes-Engordany, Andorra) for the financial support provided. This research was funded by the Spanish Government and the European Union FEDER by the concession of the grant RTI2018-098075-B-C22, the Spanish Government by the Ramón y Cajal Program (RYC2018-025977-I) and the research group Generalitat de Catalunya 2017SGR708., The purpose of this research is to study the biomechanical response of dental implants in bone-level type locations, 0.5 mm above and below the bone level. In addition, the influence of the thickness of the cortical bone on osseointegration is determined due to the mechanical loads transfer from the dental implant to the cortical and trabecular bone. The thicknesses studied were 1.5 mm and 2.5 mm. Numerical simulations were performed using a finite element method (FEM)-based model. In order to verify the FEM model, the in silico results were compared with the results obtained from a histological analysis performed in an in vivo study with 30 New Zealand rabbits. FEM was performed using a computerized 3D model of bone-level dental implants inserted in the lower jawbone with an applied axial load of 100 N. The analysis was performed using different distances from the bone level and different thicknesses of cortical bone. The interface area of bone growth was evaluated by analyzing the bone–implant contact (BIC), region of interest (ROI) and total bone area (BAT) parameters obtained through an in vivo histological process and analyzed by scanning electron microscopy (SEM). Bone-level implants were inserted in the rabbit tibiae, with two implants placed per tibia. These parameters were evaluated after three or six weeks of implantation. FEM studies showed that placements 0.5 mm below the bone level presented lower values of stress distribution compared to the other studied placements. The lower levels of mechanical stress were then correlated with the in vivo studies, showing that this position presented the highest BIC value after three or six weeks of implantation. In this placement, vertical bone growth could be observed up the bone level. The smallest thickness of the study showed a better transfer of mechanical loads, which leads to a better osseointegration. In silico and in vivo results both concluded that the implants placed 0.5 mm below the cortical bone and with lower thicknesses presented the best biomechanical and histological behavior in terms of new bone formation, enhanced mechanical stability and optimum osseointegration., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Optimization of titanium dental mesh surfaces for biological sealing and prevention of bacterial colonization

  • Cruz, Nuno
  • tondela, joão paulo
  • Martins, Maria Inês
  • Velasco-Ortega, Eugenio
  • Gil, FJ
This work was supported by the Spanish Government and the Ministry of Science and Innovation of Spain by research projects RTI2018-098075-B-C21 and RTI2018-098075-B-C22 (co-funded by the European Regional Development Fund (ERDF)—A Way to Build Europe). The authors also acknowledge Generalitat de Catalunya for the funding through the projects 2017SGR-1165 and 2017SGR708., Titanium dental meshes have a wide application in order to ensure the retention of calcium phosphate-based biomaterials to regenerate bone tissue. These meshes are temporary and must grow a soft tissue to prevent bacterial colonization and provide stability. In this work, we aimed to optimize the roughness of the meshes to obtain a good biological seal while maintaining a behavior that did not favor bacterial colonization. To this end, six types of surfaces were studied: machined as a control, polished, sandblasted with three different alumina sizes and sintered. The roughness, contact angles and biological behavior of the samples using fibroblast cultures at 7, 24 and 72 h were determined as well as cytotoxicity studies. Cultures of two very common bacterial strains in the oral cavity were also carried out: Streptococcus sanguinis and Lactobacillus salivarius. The results showed that the samples treated with alumina particles by sandblasting at 200 micrometers were the ones that performed best with fibroblasts and also with the number of bacterial colonies in both strains. According to the results, we see in this treatment a candidate for the surface treatment of dental meshes with an excellent performance., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Fatigue of narrow dental implants: influence of the hardening method

  • Pérez Antoñanzas, Roman
  • Gargallo-Albiol, Jordi
  • Altuna, Pablo
  • Herrero-Climent, Mariano
  • Gil, FJ
The work was supported by the Spanish government. Ministerio Economía y Competitividad and FEDER (UE) under the research project number RTI2018-098075-B-C22., The use of narrow titanium dental implants (NDI) for small ridges, reduced interdental space, or missing lateral incisors can be a viable option when compared to the conventional wider dental implants. Furthermore, in many cases, standard diameter implant placement may not be possible without grafting procedures, which increases the healing time, cost, and morbidity. The aim of this study was to analyze the mechanical viability of the current narrow implants and how narrow implants can be improved. Different commercially available implants (n = 150) were tested to determine maximum strength, strain to fracture, microhardness, residual stress, and fatigue obtaining the stress–number of cycles to fracture (SN) curve. Fractography was studied by scanning electron microscopy. The results showed that when the titanium was hardened by the addition of 15% of Zr or 12% cold worked, the fatigue limit was higher than the commercially pure grade 4 Ti without hardening treatment. Grade 4 titanium without hardening treatment in narrow dental implants can present fractures by fatigue. These narrow implants are subjected to high mechanical stresses and the mechanical properties of titanium do not meet the minimal requirements, which lead to frequent fractures. New hardening treatments allow for the mechanical limitations of conventional narrow implants to be overcome in dynamic conditions. These hardening treatments allow for the design of narrow dental implants with enhanced fatigue life and long-term behavior., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Relevant aspects of piranha passivation in Ti6Al4V alloy dental meshes

  • Cruz, Nuno
  • Gil Mur, Francisco Javier
  • Punset fuste, Miquel
  • Manero, José María
  • tondela, joão paulo
  • Verdeguer, Pablo
  • Aparicio, Conrado
  • Ruperez, Elisa
The work was supported by the Spanish Government and the Ministry of Science and Innovation of Spain by research projects RTI2018-098075-B-C21 and RTI2018-098075-B-C22 (cofunded by the European Regional Development Fund (ERDF), a way to build Europe). Authors also acknowledge Generalitat de Catalunya for funding through the 2017SGR-1165 project and the 2017SGR708 project., Passivation of titanium alloy dental meshes cleans their surface and forms a thin layer of protective oxide (TiO2) on the surface of the material to improve resistance to corrosion and prevent release of ions to the physiological environment. The most common chemical agent for the passivation process of titanium meshes is hydrochloric acid (HCl). In this work, we introduce the use of Piranha solution (H2SO4 and H2O2) as a passivating and bactericidal agent for metallic dental meshes. Meshes of grade 5 titanium alloy (Ti6Al4V) were tested after different treatments: as-received control (Ctr), passivated by HCl, and passivated by Piranha solution. Physical-chemical characterization of all treated surfaces was carried out by scanning electron microscopy (SEM), confocal microscopy and sessile drop goniometry to assess meshes’ topography, elemental composition, roughness, wettability and surface free energy, that is, relevant properties with potential effects for the biological response of the material. Moreover, open circuit potential and potentiodynamic tests were carried out to evaluate the corrosion behavior of the differently-treated meshes under physiological conditions. Ion release tests were conducted using Inductively Coupled Plasma mass spectrometry (ICP-MS). The antibacterial activity by prevention of bacterial adhesion tests on the meshes was performed for two different bacterial strains, Pseudomonas aeruginosa (Gram-) and Streptococcus sanguinis (Gram+). Additionally, a bacterial viability study was performed with the LIVE/DEAD test. We complemented the antibacterial study by counting cells attached to the surface of the meshes visualized by SEM. Our results showed that the passivation of titanium meshes with Piranha solution improved their hydrophilicity and conferred a notably higher bactericidal activity in comparison with the meshes passivated with HCl. This unique response can be attributed to differences in the obtained nanotextures of the TiO2 layer. However, Piranha solution treatment decreased electrochemical stability and increased ion release as a result of the porous coating formed on the treated surfaces, which can compromise their corrosion resistance. Framed by the limitations of this work, we conclude that using Piranha solution is a viable alternative method for passivating titanium dental meshes with beneficial antibacterial properties that merits further validation for its translation as a treatment applied to clinically-used meshes., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Do titanium mini-implants have the same quality of finishing and degree of contamination before and after different manipulations? An in vitro study

  • Zogheib, Tatiana
  • Walter, André
  • De la Iglesia, Fernando
  • Espinar Escalona, Eduardo
  • Gil, FJ
  • Puigdollers, Andreu
This research was funded by Spanish Government and and European Union FEDER by the concession of the grant RTI2018-098075-B-C22 and the research group Generalitat de Catalunya 2017SGR708., Evaluate the quality of finishing and degree of contamination before and after handling and surface treatment of titanium (Ti) orthodontic mini-implants (OMIs). A scanning electron microscope (SEM) study on ninety-six titanium OMIs was done. Energy-Dispersive X-ray Analysis (EDX) identified the present particles on manufactured OMIs surfaces. Then, OMIs were manipulated with gauze (dry sterile, soaked in chlorhexidine) and gloves (latex, nitrile) to evaluate the contamination of these handling materials. Finally, OMIs underwent surface treatments and were placed in bone to observe the contaminants they released. Roughness (Ra) and wettability with contact angle parameter (CA) were measured on these treated OMIs. Machined OMIs presented surface irregularities and were contaminated with manufacturing-process particles (carbon, plastic Polyvinyl Chloride PVC, aluminum). Hand-manipulated OMIs were also contaminated by the handling materials. OMIs surface characteristics were as follows: acid-etched (Ra ≈ 1.3 μm, CA ≈ 66°), machined (Ra ≈ 0.3 μm, CA ≈ 68°), SB (Ra ≈ 3.3 μm, CA ≈ 78°), and SBAO (Ra ≈ 3.1 μm, CA ≈ 92°). Bone was contaminated by OMIs surface defects and extra particles. Manufactured OMIs have surface contaminants that increase with clinical handling. Surface treatments (SBAO, a combination of sandblasting and anodic oxidation) increase the roughness and contact angle, which play an important role in osseointegration. Surface-treated OMIs leave titanium particles in the bone during their insertion-removal. The use of a gauze soaked in chlorhexidine is recommended when handling OMIs. Further investigations would be interesting to study more variables and confirm the present results., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Effect of the acid-etching on grit-blasted dental implants to improve osseointegration: histomorphometric analysis of the bone-implant contact in the rabbit tibia model

  • RÍOS-CARRASCO, BLANCA
  • Ferreira de Lemos, Bernardo
  • Herrero-Climent, Mariano
  • Gil, FJ
  • Ríos-Santos, JV
The authors are grateful to Klockner dental implants for donating the samples. This research was funded by the Spanish Government and European Union FEDER via concession of the grant RTI2018-098075-B-C22, and the research group Generalitat de Catalunya 2017SGR708., Previous studies have shown that the most reliable way to evaluate the success of an implant is by bone-to-implant contact (BIC). Recent techniques allow modifications to the implant surface that improve mechanical and biological characteristics, and also upgrade osseointegration. Objective: The aim was to evaluate the osseointegration in rabbit tibia of two different titanium dental implant surfaces: shot-blasted with Al2O3 (SB) and the same treatment with an acid-etching by immersion for 15 s in HCl/H2SO4 (SB + AE). Material and methods: Roughness parameters (Ra, Rt, and Rz) were determined by white light interferometer microscopy. Surface wettability was evaluated with a contact angle video-based system using water, di-iodomethane, and formamide. Surface free energy was determined by means of Owens and Wendt equations. Scanning electron microscopy equipped with X-ray microanalysis was used to study the morphology and determine the chemical composition of the surfaces. Twenty-four grade 4 titanium dental implants (Essential Klockner®) were implanted in the rabbit’s tibia, 12 for each surface treatment, using six rabbits. Six weeks later the rabbits were sacrificed and the implants were sent for histologic analysis. Resonance frequency analysis (RFA) was recorded both at the time of surgery and the end of the research with each device (Osstell Mentor and Osstell ISQ). Results: The roughness measurements between the two treatments did not show statistically significant differences. However, the effect of the acid etching made the surface slightly more hydrophilic (decreasing contact angle from 74.7 for SB to 64.3 for SB + AE) and it presented a higher surface energy. The bone-to-implant contact ratio (BIC %) showed a similar tendency, with 55.18 ± 15.67 and 59.9 ± 13.15 for SB and SB + AE implants, respectively. After 6 weeks of healing, the SB + AE showed an implant stability quotient (ISQ) value of 76 ± 4.47 and the shot-blasted one an ISQ value of 75.83 ± 8.44 (no statistically significant difference). Implants with different surface properties had distinctive forms of behavior regarding osseointegration. Furthermore, the Osstell system was an invasive and reliable method to measure implant stability. Conclusion: Both surfaces of implants studied showed high osseointegration. The SB and SB + AE implants used in our study had similar behavior both in terms of BIC values and RFA. The RFA systems in Osstell Mentor and Osstell ISQ confirmed nearly perfect reproducibility and repeatability., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Corrosion resistance and ion release of dental prosthesis of CoCr obtained by CAD-CAM milling, casting and laser sintering

  • Padrós, Roberto
  • Giner-Tarrida, Luis
  • Herrero-Climent, Mariano
  • Punset fuste, Miquel
  • Gil, FJ
The work was supported by the Spanish government and the Ministry of Science and Innovation of Spain by the research project number RTI2018-098075-B-C21 and RTI2018-098075-B-C22, cofounded by the EU through the European Regional Development Funds (MINECO-FEDER, EU). Authors also acknowledge Generalitat de Catalunya for its funding through the 2017SGR-1165 project., Corrosion resistance and ion release behavior have been evaluated for thirty dental restoration samples obtained by three different manufacturing systems: computer-aided design and manufacturing (CAD-CAM), traditional casting and laser sintering. The alloy used was the CoCr alloy (same batch) generally used in clinical dentistry. Corrosion resistance has been evaluated by electrochemical testing in an artificial saliva medium at 37 °C. Corrosion parameters such as critical current density (icr), corrosion potential (Ecorr), and passive current density (ip), have been determined. Cobalt and Chromium ions released from the different samples have also been analyzed in an artificial saliva medium at 37 °C by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) at different immersion times. The casted samples showed higher corrosion rates and ion-release levels. The CAD-CAM milled samples presented lower ion-release levels and better corrosion resistance due to the total solubility of the chemical elements in only one phase with the same chemical composition. This homogeneity avoids the formation of electrochemical corrosion. Moreover, the absence of defects and residual stresses increases the corrosion resistance. Casted and laser sintered prostheses have shown the presence of Cr, W, and Nb rich-precipitates which are detrimental to the corrosion resistance. These precipitates produce a decrease in the Cr content on the surface. It is well known that the corrosion resistance increases with the Cr content by the formation of Chromium oxide on the surface that increases passivation. Consequently, the decrease in Cr induces an increase in corrosion and ion release., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Use of porous titanium trabecular as a bone defect regenerator: in vivo study

  • Torres Pérez, Ana Isabel
  • Fernandez-Fairen, Mariano
  • Torres Pérez, Ángel Antonio
  • Gil, FJ
This research was funded by Spanish Government and European Union FEDER by the concession of the grant RTI2018-098075-B-C22., The application of porous materials is increasingly being used in orthopaedic surgery due to its good results. Bone growth within the pores results in excellent mechanical fixation with the bone, as well as good bone regeneration. The pores, in addition to being colonised by bone, produce a decrease in the modulus of elasticity that favours the transfer of loads to the bone. This research shows the results of an experimental study where we have created critical osteoperiosteal defects of 10 mm on rabbit’s radius diaphysis. In one group of 10 rabbits (experimental group) we have implanted a bioactive porous titanium cylinder, and in another group we have allowed spontaneous regeneration (control group). Mechanical tests were performed to assess the material. Image diagnostic techniques (X-ray, scanner and 3D scan: there are no references on the literature with the use of CT-scan in bone defects) and histological and histomorphometric studies post-op and after 3, 6 and 12 months after the surgery were performed. All the control cases went through a pseudoarthrosis. In 9 of the 10 cases of the experimental group complete regeneration was observed, with a normal cortical-marrow structure established at 6 months, similar to normal bone. Titanium trabecular reached a bone percentage of bone inside the implant of 49.3% on its surface 3 months post-op, 75.6% at 6 months and 81.3% at 12 months. This porous titanium biomaterial has appropriate characteristics to allow bone ingrowth, and it can be proposed as a bone graft substitute to regenerate bone defects, as a scaffold, or as a coating to achieve implant osteointegration., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación

Comparison between sandblasted acid-etched and oxidized titanium dental implants: in vivo study

  • Velasco-Ortega, Eugenio
  • Ortiz-Garcia, Iván
  • Jiménez Guerra, Álvaro
  • Monsalve Guil, Loreto
  • Muñoz Guzón, Fernando
  • Pérez Antoñanzas, Roman
  • Gil Mur, Francisco Javier
The authors are grateful to the Spanish Government and European Union FEDER by the concession of the project RTI2018-098075-B-C22., The surface modifications of titanium dental implants play important roles in the enhancement of osseointegration. The objective of the present study was to test two di erent implant surface treatments on a rabbit model to investigate the osseointegration. The tested surfaces were: a) acid-etched surface with sandblasting treatment (SA) and b) an oxidized implant surface (OS). The roughness was measured by an interferometeric microscope with white light and the residual stress of the surfaces was measured with X-ray residual stress Bragg–Bentano di raction. Six New Zealand white rabbits were used for the in vivo study. Implants with the two di erent surfaces (SA and OS) were inserted in the femoral bone. After 12 weeks of implantation, histological and histomorphometric analyses of the blocks containing the implants and the surrounding bone were performed. All the implants were correctly implanted and no signs of infection were observed. SA and OS surfaces were both surrounded by newly formed trabeculae. Histomorphometric analysis revealed that the bone–implant contact % (BIC) was higher around the SA implants (53.49 8.46) than around the OS implants (50.94 16.42), although there were no significant statistical di erences among them. Both implant surfaces (SA and OS) demonstrated a good bone response with significant amounts of newly formed bone along the implant surface after 12 weeks of implantation. These results confirmed the importance of the topography and physico–chemical properties of dental implants in the osseointegration., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Comparison of zirconia degradation in dental implants and femoral balls: an X-ray diffraction and nanoindentation study

  • Gil, FJ
  • Delgado‑García‑Menocal, José Angel
  • Velasco-Ortega, Eugenio
  • Bosch Canals, Begoña Maria
  • Delgado, Luis M.
  • Pérez Antoñanzas, Roman
  • Fernandez-Fairen, Mariano
This research was funded by Spanish Government and European Union FEDER by the concession of the grant RTI2018-098075-B-C22, the Spanish Government by the Ramón y Cajal Program (RYC2018-025977-I) and the research group Generalitat de Catalunya 2017SGR708., Background: New tetragonal zirconia polycrystal dental implants stabilized with yttria (Y-TZP) have appeared in the implantology market in the form of single piece or two-piece zircona implant system. These new type of implants improve the aesthetical properties compared to conventional commercially pure (c.p.) titanium used for implants, although the long term mechanical behavior of these new implants is not yet well known. In orthopaedics, the application of zirconia as femoral balls presented an important controversial use due to the premature fracture once implanted. Y-TZP dental implants can be affected by hydrothermal degradation and its behavior should be analysed to avoid a premature fracture. The scientific question behind the study is to analyse if the degradation mechanism observed in orthopaedics applications of Y-TZP is similar to that of Y-TZP for dental applications. Materials and methods: For this purpose, 30 original Y-TZP dental implants and 42 Y-TZP femoral balls fractured in vivo have been studied. Dental implants were submitted to an accelerated hydrothermal degradation to compare with the femoral balls fractured in vivo. Phase transformation as well as the mechanical behaviour of the degraded samples was studied by X ray diffraction and nanoindentation tests, respectively. Results: Results have shown that the fracture mechanism of dental implants does not resemble the mechanism observed in orthopaedic samples, presenting a good long-term behaviour. Conclusion: The results ensure the good performance of zirconia dental implants, because the degradation of the ceramic is very limited and does not affect the mechanical properties., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Bacteriostatic poly rthylene glycol plasma coatings for orthodontic titanium mini-implants

  • Rodríguez Fernández, Juan Carlos
  • Pastor, Francisco
  • Barrera Mora, Jose Maria
  • Brizuela, Aritza
  • Puigdollers, Andreu
  • Espinar, Eduardo
  • Gil, FJ
The work was supported by the Spanish Government and the Ministry of Science and Innovation of Spain by research projects RTI2018-098075-B-C21 and RTI2018-098075-B-C22 (co-funded by the European Regional Development Fund (ERDF), a way to build Europe)., Titanium mini-implants are used as anchorage for orthodontic tooth movements. However, these implants present problems due to the infection of surrounding tissues. The aim of this work was to obtain a polyethylene glycol (PEG) layer by plasma in order to achieve a bacteriostatic surface. Titanium surfaces were activated by argon plasma and, after, by PEG plasma with different powers (100, 150 and 200 W) for 30 and 60 min. The roughness was determined by white light interferometer microscopy and the wettability was determined by the contact angle technique. Surface chemical compositions were characterized by X-ray photoelectron spectroscopy (XPS) and cytocompatibility and cell adhesion studies were performed with fibroblast (hFFs) and osteoblast (SAOS-2) cells. Bacterial cultures with Spectrococcus Sanguinis and Lactobacillus Salivarius were performed, and bacterial colonization was determined. The results showed that plasma treatments do not affect the roughness. Plasma makes the surfaces more hydrophilic by decreasing the contact angles from 64.2° for titanium to 5.2° for argon-activated titanium, with values ranging from 12° to 25° for the different PEG treatments. The plasma has two effects: the cleaning of the surface and the formation of the PEG layer. The biocompatibility results were, for all cases, higher than 80%. The polymerization treatment with PEG reduced the adhesion of hFFs from 7000 to 6000 and, for SAOS-2, from 14,000 to 6500, for pure titanium and those treated with PEG, respectively. Bacterial adhesion was also reduced from 600 to 300 CFU/mm2 for Spetrococcuns Sanguinis and from 10,000 to 900 CFU/mm2 for Lactobacillus Salivarius. The best bacteriostatic treatment corresponded to PEG at 100 W and 30 s. As a consequence, the PEG coating would significantly prevent the formation of bacterial biofilm on the surface of titanium mini-implants., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Relevant design aspects to improve the stability of titanium dental implants

  • Herrero-Climent, Mariano
  • López-Jarana, P.
  • Lemos, B. F.
  • Gil, FJ
  • Falcao-Costa, Carlos
  • Ríos-Santos, José-Vicente
  • RÍOS-CARRASCO, BLANCA
The authors are grateful to the Spanish Government and European Union FEDER by the concession of the project RTI2018-098075-B-C22. The authors thank Jordi Martinez (engineer, Arquímedes Pro) for their help and contribution to this research., Post-extractional implants and immediate loading protocols are becoming much more frequent in everyday clinical practice. Given the existing literature about tapered implants, the objective of this paper was to understand whether implant shape had a direct influence on the results of the insertion torque (IT) and implant stability quotient (ISQ). Seven tapered implant prototypes were developed and distributed into three groups and compared with a control cylindrical implant—VEGA by Klockner Implant System. The implants were inserted into bovine bone type III according to Lekholm and Zarb Classification. The sample size was n = 30 for the three groups. Final IT was measured with a torquemeter, and the ISQ was measured with Penguin Resonance Frequency Analysis (RFA). Modifications done to the Prototype I did not reveal higher values of the ISQ and IT when compared to VEGA. In the second group, when comparing the five prototypes (II–VI) with VEGA, it was seen that the values of the ISQ and IT were not always higher, but there were two values of the ISQ that were statistically significantly higher with the 4.0 mm diameter Prototypes II (76.3 ± 6.1) and IV (78 ± 3.7). Prototype VII was the one with higher and significant values of the ISQ and IT. In both diameters and in both variables, all differences were statistically significant enough to achieve the higher values of primary stability values (IT and ISQ). Given the limitations of this study, it can be concluded that when there is an increase of the diameter of the implant and body taper, there is an increase of the ISQ and IT, showing that the diameter of the implant is an important criteria to obtain higher values of primary stability., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Antibacterial properties of triethoxysilylpropyl succinic anhydride silane (TESPSA) on titanium dental implants

  • Buxadera-Palomero, Judit
  • Godoy-Gallardo, Maria
  • Molmeneu, Meritxell
  • Punset fuste, Miquel
  • Gil, FJ
This research was funded by the Spanish Government and European Union FEDER by the concession of the project RTI2018-098075-B-C22, cofounded by the EU through the European Regional Development Funds, and the Generalitat de Catalunya through 2017SGR-1165 project., Infections related to dental implants are a common complication that can ultimately lead to implant failure, and thereby carries significant health and economic costs. In order to ward off these infections, this paper explores the immobilization of triethoxysilylpropyl succinic anhydride (TESPSA, TSP) silane onto dental implants, and the interaction of two distinct monospecies biofilms and an oral plaque with the coated titanium samples. To this end, titanium disks from prior machining were first activated by a NaOH treatment and further functionalized with TESPSA silane. A porous sodium titanate surface was observed by scanning electron microscopy and X-ray photoelectron spectroscopy analyses confirmed the presence of TESPSA on the titanium samples (8.4% for Ti–N-TSP). Furthermore, a lactate dehydrogenase assay concluded that TESPSA did not have a negative effect on the viability of human fibroblasts. Importantly, the in vitro effect of modified surfaces against Streptococcus sanguinis, Lactobacillus salivarius and oral plaque were studied using a viable bacterial adhesion assay. A significant reduction was achieved in all cases but, as expected, with different effectiveness against simple mono-species biofilm (ratio dead/live of 0.4) and complete oral biofilm (ratio dead/live of 0.6). Nevertheless, this approach holds a great potential to provide dental implants with antimicrobial properties., info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Mechanical characterization of dental prostheses manufactured with PMMA–graphene composites

  • Punset fuste, Miquel
  • Brizuela Velasco, Aritza
  • Pérez-Pevida, Esteban
  • Herrero-Climent, Mariano
  • Manero, José María
  • Gil, FJ
The work was supported by the Spanish government and the Ministry of Science and Innovation of Spain by the research project numbers RTI2018–098075–B–C21 and RTI2018–098075–BC22, cofounded by the EU through the European Regional Development Funds (MINECO–FEDER, EU). The authors also acknowledge the Generalitat de Catalunya for funding through the projects 2017SGR–1165 and 2017SGR708., The use of a PMMA composite with graphene is being commercialized for application as dental prostheses. The different proportions of fibers provide a wide range of colors that favors dental esthetics in prostheses. However, there are no studies that have explained the influence that graphene has on the mechanical properties. In this contribution, we studied the PMMA and PMMA material with graphene fibers (PMMA-G) in the form of discs as supplied for machining. The presence of graphene fibers has been studied by Raman spectroscopy and the Shore hardness and Vickers micro hardness were determined. Mechanical compression tests were carried out to obtain the values of maximum strength and Young’s modulus (E) and by means of pin-on-disc wear tests, the specific wear rate and the friction coefficients were determined following the established international standards. Finally, the samples were characterized by field emission scanning electron microscopy (FESEM) to characterize the graphene’s morphology inside the PMMA. The results showed the presence of graphene in PMMA and was estimated in an amount of 0.1027% by weight in G-PMMA. The Shore hardness and Vickers microhardness values did not show statistically significant differences. Differences were observed in the compression maximum strength (129.43 MPa for PMMA and 140.23 for PMMA-G) and E values (2.01 for PMMA and 2.89 GPa for PMMA-G) as well as in the lower wear rate for the G-PMMA samples (1.93 × 10−7 for PMMA and 1.33 × 10−7 mm3/N·m) with a p < 0.005. The coefficients of friction for PMMA-G decreased from 0.4032 for PMMA to 0.4001 for PMMA-G. From the results obtained, a slight content in graphene produced a significant improvement in the mechanical properties that could be observed in the prosthesis material. Therefore, we can state that the main attraction of this material for dental prosthesis is its esthetics., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Biofunctionalization with a TGFβ-1 inhibitor peptide in the osseointegration of synthetic bone grafts: an in vivo study in beagle dogs

  • Cirera, Andrea
  • Manzanares-Céspedes, Maria Cristina
  • Sevilla Sánchez, Pablo
  • Ortiz-Hernández, Monica
  • Galindo-Moreno, Pablo
  • Gil Mur, Francisco Javier
The authors kindly acknowledge the collaboration of many individuals and institutions in the present manuscript. The authors are grateful to the Spanish Government and the European Union FEDER for the concession of the project RTI2018-098075-B-C22. The experimental animals’ surgery and care were carried out with the valuable collaboration of Jordi Franch and his surgical team, Albert Barba and Katrin Rappe, in the Veterinary Faculty, Autonomous University of Barcelona; the authors would like to thank Ricardo Fernández and Allinson Olaechea for their participation during surgeries. Eva Sanchez, from the Human Anatomy and Embryology laboratory at the Bellvitge campus, and the Serveis Científico-Técnics SEM Team of the University of Barcelona are kindly acknowledged for their technical support regarding the management of the undecalcified samples as well as Andrés Catena for his help during the statistical analysis., Objectives: The aim of this research was to determine the osseointegration of two presentations of biphasic calcium phosphate (BCP) biomaterial—one untreated and another submitted to biofunctionalization with a TGF-β1 inhibitor peptide, P144, on dental alveolus. Materials and Methods: A synthetic bone graft was used, namely, (i) Maxresorb® (Botiss Klockner) (n = 12), and (ii) Maxresorb® (Botiss Klockner) biofunctionalized with P144 peptide (n = 12). Both bone grafts were implanted in the two hemimandibles of six beagle dogs in the same surgical time, immediately after tooth extraction. Two dogs were sacrificed 2, 4, and 8 weeks post implant insertion, respectively. The samples were submitted to histomorphometrical and histological analyses. For each sample, we quantified the new bone growth and the new bone formed around the biomaterial’s granules. After optical microscopic histological evaluation, selected samples were studied using backscattered scanning electron microscopy (BS-SEM). Results: The biofunctionalization of the biomaterial’s granules maintains a stable membranous bone formation throughout the experiment timeline, benefitting from the constant presence of vascular structures in the alveolar space, in a more active manner that in the control samples. Better results in the experimental groups were proven both by quantitative and qualitative analysis. Conclusions: Synthetic bone graft biofunctionalization results in slightly better quantitative parameters of the implant’s osseointegration. The qualitative histological and ultramicroscopic analysis shows that biofunctionalization may shorten the healing period of dental biomaterials. View Full-Text, info:eu-repo/semantics/acceptedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

The characterization of titanium particles released from bone-level titanium dental implants: effect of the size of particles on the ion release and cytotoxicity behaviour

  • Callejas, Juan Antonio
  • Brizuela Velasco, Aritza
  • Ríos Carrasco, Blanca
  • Gil, FJ
The authors would like to thank SOADCO (Escaldes-Engordany, Andorra) for the financial support provided. This research was funded by the Spanish Government and European Union FEDER by the concession of the grant RTI2018-098075-B-C22., Many studies are being carried out on the particles released during the implantoplasty process in the machining of dental implants to remove bacterial biofilms. However, there are no studies on the release of particles produced by the insertion of bone-level dental implants due to the high compressive frictional loads between the rough titanium implant and the bone tissue. This paper aims to characterize the released particles and determine the release of titanium ions into the physiological environment and their cytocompatibility. For this purpose, 90 dental implants with a neck diameter of 4 mm and a torque of 22 Ncm were placed in 7 fresh cow ribs. The placement was carried out according to the established protocols. The implants had a roughness Ra of 1.92 μm. The arrangement of the particles in the bone tissue was studied by micro-CT, and no particle clusters were observed. The different granulometries of 5, 15, and 30 μm were obtained; the specific surface area was determined by laser diffraction; the topography was determined by scanning electron microcopy; and the particles were chemically analysed by X-ray energy microanalysis. The residual stresses of the particles were obtained by X-ray diffraction using the Bragg-Bentano configuration. The release of titanium ions to the physiological medium was performed using ICP-MS at 1, 3, 7, 14, and 21 days. The cytocompatibility of the particles with HFF-1 fibroblast and SAOS-2 osteoblast cultures was characterized. The results showed that the lowest specific surface area (0.2109 m2/g) corresponds to the particles larger than 30 μm being higher than 0.4969 and 0.4802 m2/g of those that are 5 and 15 μm, respectively, observing in all cases that the particles have irregular morphologies without contamination of the drills used in the surgery. The highest residual stresses were found for the small particles, −395 MPa for the 5 μm particles, and −369 for the 15 μm particles, and the lowest residual stresses were found for the 30 μm particles with values of −267 MPa. In all cases, the residual stresses were compressive. The lowest ion release was for the 30 μm samples, as they have the lowest specific surface area. Cytocompatibility studies showed that the particles are cytocompatible, but it is the smallest ones that are lower and very close to the 70% survival limit in both fibroblasts and osteoblasts., info:eu-repo/semantics/publishedVersion
Recercat. Dipósit de la Recerca de Catalunya
Publicación Artículo científico (JournalArticle)

Characteristics of particles and debris released after implantoplasty: a comparative study

  • Wu, xixi
  • Cai, Changjie
  • Gil, FJ
  • Jantz, Elizabeth
  • Al Sakka, Yacoub
  • Padial-Molina, Miguel
  • Suárez López del Amo, Fernando
The work was supported by Graduate Periodontic, College of Dentistry, OUHSC and Department of Occupational and Environmental Health, Hudson College of Public Health, OUHSC. The work was also supported by the Spanish Government and the Ministry of Science and Innovation of Spain by research projects RTI2018-098075-B-C21 and RTI2018-098075-B-C22 (co-funded by the European Regional Development Fund (ERDF), a way to build Europe)., Titanium particles embedded on peri-implant tissues are associated with a variety of detrimental effects. Given that the characteristics of these detached fragments (size, concentration, etc.) dictate the potential cytotoxicity and biological repercussions exerted, it is of paramount importance to investigate the properties of these debris. This study compares the characteristics of particles released among different implant systems (Group A: Straumann, Group B: BioHorizons and Group C: Zimmer) during implantoplasty. A novel experimental system was utilized for measuring and collecting particles generated from implantoplasty. A scanning mobility particle sizer, aerodynamic particle sizer, nano micro-orifice uniform deposit impactor, and scanning electron microscope were used to collect and analyze the particles by size. The chemical composition of the particles was analyzed by highly sensitive microanalysis, microstructures by scanning electron microscope and the mechanical properties by nanoindentation equipment. Particles released by implantoplasty showed bimodal size distributions, with the majority of particles in the ultrafine size range (<100 nm) for all groups. Statistical analysis indicated a significant difference among all implant systems in terms of the particle number size distribution (p < 0.0001), with the highest concentration in Group B and lowest in Group C, in both fine and ultrafine modes. Significant differences among all groups (p < 0.0001) were also observed for the other two metrics, with the highest concentration of particle mass and surface area in Group B and lowest in Group C, in both fine and ultrafine modes. For coarse particles (>1 µm), no significant difference was detected among groups in terms of particle number or mass, but a significantly smaller surface area was found in Group A as compared to Group B (p = 0.02) and Group C (p = 0.005). The 1 first minute of procedures had a higher number concentration compared to the second and third minutes. SEM-EDS analysis showed different morphologies for various implant systems. These results can be explained by the differences in the chemical composition and microstructures of the different dental implants. Group B is softer than Groups A and C due to the laser treatment in the neck producing an increase of the grain size. The hardest implants were those of Group C due to the cold-strained titanium alloy, and consequently they displayed lower release than Groups A and B. Implantoplasty was associated with debris particle release, with the majority of particles at nanometric dimensions. BioHorizons implants released more particles compared to Straumann and Zimmer. Due to the widespread use of implantoplasty, it is of key importance to understand the characteristics of the generated debris. This is the first study to detect, quantify and analyze the debris/particles released from dental implants during implantoplasty including the full range of particle sizes, including both micro- and nano-scales., info:eu-repo/semantics/publishedVersion