Pasar al contenido principal

MICROSCOPIO MULTIMODAL PARA LA OBTENCION DE IMAGENES BIOMEDICAS 3D

RTI2018-099041-B-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario UNIVERSITAT DE VALÈNCIA

Resultados relacionados

Resultados totales (Incluyendo duplicados): 5
Encontrada(s) 1 página(s)

RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Fast and robust wave optics-based reconstruction protocol for Fourier lightfield microscopy

  • Incardona, Nicolo
  • Tolosa, Angel
  • Saavedra, Genaro
  • Martinez-Corral, Manuel
  • Sánchez-Ortiga, Emilio|||0000-0001-5524-5302
[EN] Fourier lightfield microscopy (FLMic) is a powerful technique to record 3D images of thick dynamic samples. Belonging FLMic to the general class of computational imaging techniques, its efficiency is determined by sev-eral factors, like the optical system, the calibration process, the reconstruction algorithm, or the computation architecture. In the case of FLMic the calibration and the reconstruction algorithm should be fully adapted to the singular features of the technique. To this end, and concerning the reconstruction, we discard the use of experimental PSFs, and propose the use of a synthetic one, which is calculated on the basis of paraxial optics and taking into account the equal influence of diffraction and pixelation. Using this quite simple PSF, performing the adequate calibration and finally implementing the algorithm in GPU, we demonstrate here the possibility of obtaining 3D images with good results in terms of resolution and strong improvement in terms of computation time. In summary, and aiming to accelerate the widespread of FLMic among microscopy users and researchers, we are proposing a fast protocol fully adapted to FLMic and that is very flexible and robust against any slight misalignment or against the change of any optical element., This research was funded by Grant RTI2018-099041-B-I00, which is co-founded by the Ministerio de Ciencia, Innovacion y Universidades (Spain), by the European Regional Development Fund, and by Generalitat Valenciana (Spain) under Grant PROMETEO/2019/048.
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Publicación Artículo científico (JournalArticle)

Resolution limit in opto-digital systems revisited

  • Galdón, Laura
  • Garcia-Sucerquia, Jorge
  • Saavedra, Genaro
  • Martinez-Corral, Manuel
  • Sánchez-Ortiga, Emilio|||0000-0001-5524-5302
[EN] The resolution limit achievable with an optical system is a fundamental piece of information when characterizing its performance, mainly in case of microscopy imaging. Usually this information is given in the form of a distance, often expressed in microns, or in the form of a cutoff spatial frequency, often expressed in line pairs per mm. In modern imaging systems, where the final image is collected by pixelated digital cameras, the resolution limit is determined by the performance of both, the optical systems and the digital sensor. Usually, one of these factors is considered to be prevalent over the other for estimating the spatial resolution, leading to the global performance of the imaging system ruled by either the classical Abbe resolution limit, based on physical diffraction, or by the Nyquist resolution limit, based on the digital sensor features. This estimation fails significantly to predict the global performance of opto-digital imaging systems, like 3D microscopes, where none of the factors is negligible. In that case, which indeed is the most common, neither the Abbe formula nor the Nyquist formula provide by themselves a reliable prediction for the resolution limit. This is a serious drawback since systems designers often use those formulae as design input parameters. Aiming to overcome this lack, a simple mathematical expression obtained by finely articulating the Abbe and Nyquist formulas, to easily predict the spatial resolution limit of opto-digital imaging systems, is proposed here. The derived expression is tested experimentally, and shows to be valid in a broad range of opto-digital combinations., Universidad Nacional de Colombia (Hermes 347 grants (53712,50069,49570)); Generalitat Valenciana (PROMETEO/2019/048); European Regional Development Fund (RTI2018-099041-B-I00); Ministerio de Ciencia, Innovación y Universidades (RTI2018-099041-B-I00).
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

An indirect measurement of the speed of light in a General Physics Laboratory

  • Arribas Garde, Enrique
  • Escobar García, Isabel
  • Ramírez Vázquez, Raquel
  • Franco, María Teresa
  • Beléndez, Augusto
  • Beléndez, Augusto
  • Beléndez, Augusto|||/items/1ea7a525-ee45-4792-bd9a-a54f76963120
This paper features an indirect method to measure the speed of light. First, the electrical permittivity of air ε0, is obtained, by using a capacitance meter to measure the capacitance of a parallel-plate capacitor, by varying the separation between its plates. By means of a least squares adjustment, the slope of the straight line is calculated which is related to ε0. Next, the magnetic permittivity of air μ0 is obtained by using a solenoid through which different currents are circulated and the magnetic field is measured in its centre using the Hall sensor of a Smartphone. By means of a least squares adjustment, the slope of the straight line is calculated which is related to μ0. Once ε0 and μ0 have been obtained, the speed of light is calculated by the expression with its corresponding absolute and relative errors, to verify if the obtained value is compatible with the exact value of c.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Projectile motion revisited: Does the distance between the launcher and the object always increase?

  • Escobar García, Isabel
  • Arribas Garde, Enrique
  • Ramírez Vázquez, Raquel
  • Beléndez, Augusto
  • Beléndez, Augusto
  • Beléndez, Augusto|||/items/1ea7a525-ee45-4792-bd9a-a54f76963120
In this paper, we have shown that parabolic motion from a critical launch angle has an unexpected property related to the distance between the object and the launcher. This distance decreases in a time interval that occurs between two moments: one, in which distance has a maximum and another in which it has a minimum. As it will be shown, this only happens in launch angles greater than cos∅c = 1/3, that is ∅c ≅ 70.53º. The launch we have studied occurs from the ground and we have not taken into account air friction. We have not considered the possible variations in the acceleration of gravity, that is, we have taken it as a constant throughout the movement of the projectile. We have used dimensionless coordinates so that the focus is on the angular variable. In addition, at the end of the study, we have used polar variables to visualize what happened. This is a very didactic approach, which can be used in the first year of STEM university degrees. It will also prove useful for teachers that wish to explain parabolic motion in their classes.
Repositorio Institucional de la Universidad de Burgos (RIUBU)
Publicación Artículo científico (JournalArticle)

Machine Learning-Based View Synthesis in Fourier Lightfield Microscopy

  • Rostan, Julen
  • Incardona, Nicolo
  • Sánchez-Ortiga, Emilio
  • Martínez-Corral, Manuel
  • Latorre Carmona, Pedro
Current interest in Fourier lightfield microscopy is increasing, due to its ability to acquire 3D images of thick dynamic samples. This technique is based on simultaneously capturing, in a single shot, and with a monocular setup, a number of orthographic perspective views of 3D microscopic samples. An essential feature of Fourier lightfield microscopy is that the number of acquired views is low, due to the trade-off relationship existing between the number of views and their corresponding lateral resolution. Therefore, it is important to have a tool for the generation of a high number of synthesized view images, without compromising their lateral resolution. In this context we investigate here the use of a neural radiance field view synthesis method, originally developed for its use with macroscopic scenes acquired with a moving (or an array of static) digital camera(s), for its application to the images acquired with a Fourier lightfield microscope. The results obtained and presented in this paper are analyzed in terms of lateral resolution and of continuous and realistic parallax. We show that, in terms of these requirements, the proposed technique works efficiently in the case of the epi-illumination microscopy mode., This research was funded by Grant RTI2018-099041-B-I00, which is co-founded by the Ministerio de Ciencia, Innovacion y Universidades (Spain), by the European Regional Development Fund, and by Generalitat Valenciana (Spain) under Grant PROMETEO/2019/048.