Pasar al contenido principal

AUTOENFOQUE EN IMAGEN ULTRASONICA TRIDIMENSIONAL

RTI2018-099118-A-I00

•
Nombre agencia financiadora Agencia Estatal de Investigación
Acrónimo agencia financiadora AEI
Programa Programa Estatal de I+D+i Orientado a los Retos de la Sociedad
Convocatoria Proyectos I+D+i Retos de Investigación
Año convocatoria 2018
Plan Estatal 2017-2020 Plan Estatal de Investigación Científica y Técnica y de Innovación
Centro beneficiario AGENCIA ESTATAL CONSEJO SUPERIOR DE INVESTIGACIONES CIENTIFICAS (CSIC)

Resultados relacionados

Resultados totales (Incluyendo duplicados): 3
Encontrada(s) 1 página(s)

DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Ferroelectret Ultrasonic Transducers for Pulse-Echo Water Immersion

  • Quirce Aguilar, Julio
  • Svilainis, Linas
  • Camacho Sosa-Días, Jorge
  • Gómez Álvarez-Arenas, Tomás
Ferroelectrets are thin and porous polymeric films with a cellular microstructure, high porosity, permanent polarization and piezoelectric response. They have been used for different applications, where one of the most interesting ones is for the fabrication of air-coupled ultrasonic transducers. More recently they have been tested as water immersion transducers, showing a promising wide bandwidth but limited sensitivity along with other technical problems. This paper investigates ultrasonic transducers for water immersion and pulse-echo operation based on ferroelectret films. Two different ferroelectret foams with different resonant frequencies, acoustic impedances and cellular structures were tried. Flat and spherically focused prototypes (radius of curvature of 22 and 35 mm) were produced and tested. Finally, different materials and methods were tried to provide a protective surface coating. Acoustic field measurements for the focused transducers confirm the possibility to efficiently focus the ultrasonic beam by the proposed fabrication method, with focal spot size of 1.86 mm at −6 dB. Results show that in spite of the reduced sensitivity (about −115 dB), some of the tried ferroelectret films provide a very wide band response (−6 dB band from 0.29 to 2.7 MHz) and short pulse duration (2–3 us) that can be of interest for different applications, This work was supported in part by Ministerio de Economía y Competitividad under grants ECERES (DPI2016- 78876-R, AEI/FEDER, UE) and AIMUT (RTI2018-099118-A-I00, MCIU/AEI/FEDER, UE) and received partial funding (LS) from European Regional Development Fund (project No. 01.2.2-LMT-K-718-03-0026) under grant agreement with the Research Council of Lithuania (LMTLT)., This work was supported in part by Ministerio de Economía y Competitividad under grants ECERES (DPI2016- 78876-R, AEI/FEDER, UE) and AIMUT (RTI2018-099118-A-I00, MCIU/AEI/FEDER, UE) and received partial funding (LS) from European Regional Development Fund (project No. 01.2.2-LMT-K-718-03-0026) under grant agreement with the Research Council of Lithuania (LMTLT)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Artificial Intelligence and Democratization of the Use of Lung Ultrasound in COVID-19: On the Feasibility of Automatic Calculation of Lung Ultrasound Score

  • Camacho Sosa-Días, Jorge
  • Muñoz, Mario
  • Genovés, Vicente
  • Herráiz, Joaquín L.
  • Ortega, Ignacio
  • Belarra, Adrián
  • González, Ricardo
  • Sánchez, David
  • Giacchetta, Roberto Carlos
  • Trueba Vicente, Ángela
  • Tung-Chen, Yale
9 páginas, 6 figuras, 3 tablas, During the COVID-19 pandemic, lung ultrasound has been revealed as a powerful technique for diagnosis and follow-up of pneumonia, the principal complication of SARS-CoV-2 infection. Nevertheless, being a relatively new and unknown technique, the lack of trained personnel has limited its application worldwide. Computer-aided diagnosis could possibly help to reduce the learning curve for less experienced physicians, and to extend such a new technique such as lung ultrasound more quickly. This work presents the preliminary results of the ULTRACOV (Ultrasound in Coronavirus disease) study, aimed to explore the feasibility of a real-time image processing algorithm for automatic calculation of the lung ultrasound score (LUS). A total of 28 patients positive on COVID-19 were recruited and scanned in 12 thorax zones following the lung score protocol, saving a 3 s video at each probe position. Those videos were evaluated by an experienced physician and by a custom developed automated detection algorithm, looking for A-Lines, B-Lines, consolidations, and pleural effusions. The agreement between the findings of the expert and the algorithm was 88.0% for B-Lines, 93.4% for consolidations and 99.7% for pleural effusion detection, and 72.8% for the individual video score. The standard deviation of the patient lung score difference between the expert and the algorithm was ±2.2 points over 36. The exam average time with the ULTRACOV prototype was 5.3 min, while with a conventional scanner was 12.6 min. Conclusion: A good agreement between the algorithm output and an experienced physician was observed, which is a first step on the feasibility of developing a real-time aided-diagnosis lung ultrasound equipment. Additionally, the examination time was reduced to less than half with regard to a conventional ultrasound exam. Acquiring a complete lung ultrasound exam within a few minutes is possible using fairly simple ultrasound machines that are enhanced with artificial intelligence, such as the one we propose. This step is critical to democratize the use of lung ultrasound in these difficult times., This research was partially funded by CDTI (Spanish acronym: Centre for Industrial Technological Development), funding number COI-20201153. Partially supported by the Google Cloud Research Credits program with the funding number GCP19980904, by the project RTI2018-099118-A-I00 founded by MCIU/AEI/FEDER UE and by the European Commission–NextGenerationEU, through CSIC’s Global Health Platform (PTI Salud Global)., Peer reviewed
DIGITAL.CSIC. Repositorio Institucional del CSIC
Publicación Artículo científico (JournalArticle)

Inter-Rater Variability in the Evaluation of Lung Ultrasound in Videos Acquired from COVID-19 Patients

  • Herráiz, Joaquín L.
  • Freijo, Clara
  • Camacho Sosa-Días, Jorge
  • Muñoz, Mario
  • González, Ricardo
  • Alonso-Roca, Rafael
  • Álvarez-Troncoso, Jorge
  • Beltrán-Romero, Luis Matías
  • Bernabeu-Wittel, Máximo
  • Blancas, Rafael
  • Calvo-Cebrián, Antonio
  • Campo-Linares, Ricardo
  • Chehayeb-Morán, Jaldún
  • Chorda-Ribelles, José
  • García-Rubio, Samuel
  • García-de-Casasola, Gonzalo
  • Gil-Rodrigo, Adriana
  • Henríquez-Camacho, César
  • Hernandez-Píriz, Alba
  • Hernández-Quiles, Carlos
  • Llamas-Fuentes, Rafael
  • Luordo, Davide
  • Marín-Baselga, Raquel
  • Martínez-Díaz, María Cristina
  • Mateos-González, María
  • Mendez-Bailon, Manuel
  • Miralles-Aguiar, Francisco
  • Nogue, Ramón
  • Nogué, Marta
  • Ortiz de Urbina-Antia, Borja
  • Oviedo-García, Alberto Ángel
  • Porcel, José M.
  • Rodríguez, Santiago
  • Rodríguez-Serrano, Diego Aníbal
  • Sainz, Talía
  • Sánchez-Barrancos, Ignacio Manuel
  • Torres-Arrese, Marta
  • Torres-Macho, Juan
  • Trueba Vicente, Ángela
  • Villén-Villegas, Tomás
  • Zafra-Sánchez, Juan José
  • Tung-Chen, Yale
12 páginas, 7 figuras, 1 tabla, Lung ultrasound (LUS) allows for the detection of a series of manifestations of COVID-19, such as B-lines and consolidations. The objective of this work was to study the inter-rater reliability (IRR) when detecting signs associated with COVID-19 in the LUS, as well as the performance of the test in a longitudinal or transverse orientation. Thirty-three physicians with advanced experience in LUS independently evaluated ultrasound videos previously acquired using the ULTRACOV system on 20 patients with confirmed COVID-19. For each patient, 24 videos of 3 s were acquired (using 12 positions with the probe in longitudinal and transverse orientations). The physicians had no information about the patients or other previous evaluations. The score assigned to each acquisition followed the convention applied in previous studies. A substantial IRR was found in the cases of normal LUS (κ = 0.74), with only a fair IRR for the presence of individual B-lines (κ = 0.36) and for confluent B-lines occupying < 50% (κ = 0.26) and a moderate IRR in consolidations and B-lines > 50% (κ = 0.50). No statistically significant differences between the longitudinal and transverse scans were found. The IRR for LUS of COVID-19 patients may benefit from more standardized clinical protocols., This research was partially funded by CDTI (Spanish acronym: Centre for Industrial Tech- nological Development), funding number COI-20201153. Partially supported by the Google Cloud Research Credits program with the funding number GCP19980904, by the project RTI2018-099118- A-I00 founded by MCIU/AEI/FEDER UE and by the European Commission–NextGenerationEU, through CSIC’s Global Health Platform (PTI Salud Global)., Peer reviewed