Stone masonry confinement with FRP and FRCM composites

  • Estevan, Luis
  • Baeza, F. Javier
  • Bru, David
  • Ivorra, Salvador
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Bru, David|||/items/00098396-76d2-44fc-8652-746908d86a33
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
In the last decades, there are many reports on the use of composites as reinforcement of structural elements under compression, especially regarding the confinement of concrete structures, but works on stone or masonry columns are limited. Initially, FRP jackets were used because their high structural performance. However, they present some drawbacks like aesthetics or water impermeability, which can affect their applicability in historical constructions made in stone. Recently, FRCM appeared as an alternative with better compatibility with masonry structures. In the present study, a comparison between different composite materials to confine masonry specimens was made. FRPs with carbon or glass fibers and epoxy matrix, and FRCM with basalt or glass fiber mesh in a cementitious matrix were used to confine masonry, made in calcarenite cylindrical pieces and lime mortar. Strength and ductility gains under compressive loads were measured, and compared to the recommendations of different guidelines. Unidirectional FRPs were the optimal solution from a strengthening point of view. On the other hand, FRCM confinement offered more ductility than unreinforced masonry, but showed a softening behavior. Finally, regarding the studied design codes, the specific parameters included for masonry structures seemed enough to obtain accurate predictions of the compressive strength increase due to the confinement with the tested composites.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Enhancing fire resistance of masonry structures: The potential of ultra high performance concrete (UHPC)

  • Estevan, Luis
  • Torres, Benjamín
  • Baeza, F. Javier
  • Gattulli, Vincenzo
  • Ivorra, Salvador
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
  • Torres, Benjamín|||/items/605a19b9-d11e-44d5-b7d8-28a71eaaaa72
The potential of ultra high performance concrete (UHPC) for strengthening masonry structures is evaluated in this work, both under normal service conditions and after exposure to high temperatures, as a significant gap has been identified on this topic at the present time. The mechanical properties of UHPC exposed up to 800 °C are analyzed by means of destructive and non-destructive tests, and the UHPC-to-masonry bond capacity is tested, depending on temperature and substrate preparation. The strengthening of masonry columns by confinement is studied, proving that UHPC jackets can double the compressive strength and provide ductility, even after exposure to high temperatures. Strengthening of masonry walls to in-plane loads is also evaluated, finding that UHPC layers can increase the shear strength and prevent brittle failures. Experimental results are compared with the predictions of theoretical models from some design guides, slightly adapted to the context of this research, obtaining a good degree of accuracy.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Numerical analysis of residual tensile properties and strain rate sensitivity of textile reinforced mortar interface behavior after thermal exposure

  • La Scala, Armando
  • Foti, Dora
  • Pereiro-Barceló, Javier
  • Ivorra, Salvador
  • Pereiro-Barceló, Javier|||/items/6dce1875-46f5-4715-9229-958f7be7228d
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
This study presents a comprehensive finite element (FE) investigation of Textile-Reinforced Mortar (TRM) composites subjected to uniaxial tensile loading at temperatures of 20, 200, and 400 °C. A detailed micro-modeling approach with cohesive zone models was implemented to characterize the complex interface mechanics between textile reinforcement and mortar matrix. The numerical models were rigorously validated against experimental data from tensile tests and Digital Image Correlation (DIC) measurements, demonstrating excellent agreement with deviations below 7%. The research identified critical interface parameters governing TRM behavior, including normal and tangential stiffness components, strength limits, and damage evolution characteristics across different temperature regimes. Results revealed distinct temperature-dependent transitions in failure mechanisms, shifting from predominantly shear-dominated behavior at ambient temperature to slip-dominated responses at elevated temperatures. A notable finding was the enhanced mechanical performance at 200 °C, attributed to improved fiber-matrix interface properties, followed by severe degradation at 400 °C. Parametric sensitivity analyses identified key relationships between interface parameters and mechanical response, with a critical threshold temperature at 200 °C where interface properties showed heightened sensitivity to parameter variations. Extended numerical simulations indicated potential loading-rate dependency, particularly pronounced at elevated temperatures. This work provides essential insights into the thermal degradation mechanisms of TRM systems and establishes a robust numerical framework for predicting their residual performance after thermal exposure, providing a foundational framework for multi-hazard assessment.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Evaluation of the mechanical response of calcarenite specimens confined with fiber reinforced polymers after high temperature exposure

  • Estevan, Luis
  • Baeza, F. Javier
  • Varona Moya, Francisco de Borja
  • Ivorra, Salvador
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
  • Varona Moya, Francisco de Borja|||/items/b2f78412-2138-4bd9-a2e5-a9b3e391373e
Although the confinement of compressed columns with composite materials has been extensively studied during the last decades, scarce research has been conducted in the particular case of reinforcement of stone or masonry elements subjected to high temperatures. This work reports an experimental study on the mechanical behavior of cylindrical stone specimens exposed to temperatures of 600 °C and subsequently cooled with two different methods: slow air cooling or rapid water immersion. The effect of confinement by means of carbon or glass fiber reinforced polymers (FRP) is studied. The mechanical properties of the rock are also analyzed by non-destructive tests, which constitute very appropriate techniques when working on heritage buildings. In general terms, it was found that the effect of temperature significantly reduced the strength and elastic modulus of the rock. On the other hand, FRP confinement provided large increases in strength and ultimate strain, compared to unreinforced samples. An important finding of this work is that the response of the confined specimens seems to depend basically on the properties of the FRP laminate, and not on the damage that the stone core may have suffered. Finally, the experimental results are compared with the predictions of analytical confinement models included in the most relevant international design guides. It has been proven that these models seem to provide accurate results in the case of unheated and unaltered stone, although they show larger deviations in the case of high temperature exposed specimens.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Shear strengthening of masonry walls with Textile Reinforced Mortars (TRM) under high temperature exposure

  • Estevan, Luis
  • Torres, Benjamín
  • Varona Moya, Francisco de Borja
  • Baeza, F. Javier
  • Ivorra, Salvador
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
  • Torres, Benjamín|||/items/605a19b9-d11e-44d5-b7d8-28a71eaaaa72
  • Varona Moya, Francisco de Borja|||/items/b2f78412-2138-4bd9-a2e5-a9b3e391373e
The behavior of masonry walls strengthened with Textile Reinforced Mortars (TRM) is a topic that has received considerable attention from researchers in recent years. However, the response of such elements after exposure to high temperature is an issue that remains to be explored extensively. This study analyzes the behavior of TRM-strengthened brick masonry panels with glass and carbon fiber meshes subjected to temperatures up to 600 °C, and subsequently tested under diagonal compression. The reinforcements were applied before or after temperature exposure, to analyze the effectiveness of damaged or undamaged TRMs, thus simulating different scenarios that might occur in a real building under a fire event. In general terms, the results showed that TRMs with carbon fibers exhibited a better response in these conditions, restoring the walls to their original capacity and providing additional ductility, whilst reinforcements with glass fibers seemed to be more affected by temperature. Finally, the experimental results are here compared to predictions from available design guides, in order to assess the accuracy that these codes would provide in these circumstances.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Influence of masonry bonding patterns on the diagonal compressive strength of brick walls

  • Reynau, Ricardo
  • Bru, David
  • Ivorra, Salvador
  • Bru, David|||/items/00098396-76d2-44fc-8652-746908d86a33
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
During the 19th and 20th centuries, brick and masonry load-bearing walls were widely used in the construction of residential and public buildings. These structural elements exhibit relatively low compressive strength and brittle failure behavior under horizontal seismic loads. Moreover, the internal arrangement of brick units and mortar joints varies according to the masonry bond pattern selected by master builders, directly impacting the wall’s mechanical performance. This study aims to clarify how different masonry bond patterns influence the structural integrity of these walls, specifically examining diagonal compressive strength, transverse elastic modulus, and detailed failure typologies and zones. To achieve these insights, two complementary testing methods were employed: traditional displacement sensors and digital image correlation (DIC), an advanced optical technique that captures high-resolution strain and crack propagation data. Findings indicate that crack patterns and shear strength significantly depend on the masonry bond type, highlighting the critical role of bonding arrangements in determining a wall’s resilience and failure behavior under loading. These results provide a refined understanding of the factors contributing to masonry wall collapse, with specific bond types showing distinct vulnerability or resistance patterns. Overall, this research offers valuable guidance for the assessment, preservation, and reinforcement of historical masonry structures, allowing engineers and conservation specialists to better anticipate structural responses and mitigate potential risks associated with lateral and seismic forces.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

FRP Confinement of Stone Samples after Real Fire Exposure

  • Estevan, Luis
  • Baeza, F. Javier
  • Varona Moya, Francisco de Borja
  • Ivorra, Salvador
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
  • Varona Moya, Francisco de Borja|||/items/b2f78412-2138-4bd9-a2e5-a9b3e391373e
The mechanical properties of stone materials can be severely affected by exposure to high temperatures. The effect of fire on stone buildings could cause irreversible damage and make it necessary to retrofit the affected elements. Particularly, the strengthening of columns by confinement with composites has been widely improved during the last decades. Today, fiber reinforced polymer (FRP) confinement represents a very interesting alternative to traditional steel solutions. This work studied the behavior of cylindrical stone specimens subjected to real fire action and confined by means of CFRP or GFRP jackets, with the aim of assessing the effectiveness of these reinforcement systems applied to a material that has previously been seriously damaged by high temperature exposure. In general, the strengthened samples showed notable increases in strength and ductility. The response seemed to depend basically on the FRP properties and not on the degree of damage that the stone core may have suffered. Finally, the results obtained experimentally were compared with the confinement models proposed by the available design guides, in order to evaluate the accuracy that these models can offer under the different situations addressed in this research.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Effect of high temperature on textile reinforced Mortar-to-masonry bond

  • Estevan, Luis
  • Baeza, F. Javier
  • Varona Moya, Francisco de Borja
  • Pereiro-Barceló, Javier
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Pereiro-Barceló, Javier|||/items/6dce1875-46f5-4715-9229-958f7be7228d
  • Varona Moya, Francisco de Borja|||/items/b2f78412-2138-4bd9-a2e5-a9b3e391373e
One of the most important factors that define the effectiveness of Textile Reinforced Mortar (TRM) is their bond capacity to the substrate. This property may be compromised in case of exposure to high temperatures, although the information available on this topic is very limited at the moment. This paper analyzes the bond behavior on clay brick substrates of TRMs with carbon or glass textiles and different hydraulic lime mortar matrix. The effect of bond length and 3 levels of exposure temperature (20, 200 and 400 °C) are studied. The results show that at 200 °C the TRMs analyzed retain a significant part of their bond capacity, although textile slippage within the mortar matrix occurs and the tensile capacity of the fibers cannot be fully exploited, even if the meshes are properly anchored. At 400 °C the bond capacity may be completely lost, and debonding at the matrix-to-substrate interface may occur at very low stresses, depending on the properties of each TRM.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Experimental Damage Identification in Masonry Structures by OMA

  • Bru, David
  • Ivorra, Salvador
  • Camassa, Domenico
  • Bru, David|||/items/00098396-76d2-44fc-8652-746908d86a33
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
This paper presents a study carried out in different types of masonry structures to identify existing damage through dynamic identification techniques using operational modal analysis. A cross vault, a masonry wall and a simple clay brick construction have been analyzed. The three cases have been tested on a full scale in the laboratory. The cross vault has been subjected to a settlement of one of its supports, the damage has occurred and then it has been repaired by using Textile Reinforced Mortars (TRM). In the case of the wall and the simple construction, the damage has been generalized by means of horizontal loads simulating a seismic action by a cyclic incremental load, after the generation of the damage, it has been repaired using TRM. In all cases, a dynamic identification has been carried out prior to the generation of the damage, after the generation of the damage and later after its repair, finally after a new process of damage the structural health changes have been monitored. In the four phases, an identification of the dynamic characteristics of the structures has been carried out, both main frequencies and damping factor associated with each mode shape. Regarding operational modal analysis, the first vibration modes have been identified. Singular Value Plot have been obtained through the EFDD technique. In general terms, the results of the investigation showed that the effect of cracking generated by both horizontal cyclic loads and vertical displacements located in one of the supports generated a decrease in the vibration frequencies and an increase in the structural damping factors for the different vibration modes. On the other hand, in relation to the effect of the reinforcement techniques employed, the results showed the feasibility of recovering or even slightly increasing the stiffness of the original damaged structure. However, the results for the strengthened structures also showed that the intervention on the damaged structure tended to reduce the structural damping factors with respect to the unreinforced structure. In addition, it was also observed that after the tests the reinforced and newly damaged structures showed dynamic characteristics very similar to the unreinforced damaged structures.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Mechanical behavior of TRM masonry panels previously damaged by high temperatures

  • Torres, Benjamín
  • Varona Moya, Francisco de Borja
  • Baeza, F. Javier
  • Estevan, Luis
  • Ivorra, Salvador
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
  • Torres, Benjamín|||/items/605a19b9-d11e-44d5-b7d8-28a71eaaaa72
  • Varona Moya, Francisco de Borja|||/items/b2f78412-2138-4bd9-a2e5-a9b3e391373e
Masonry walls exhibit low tensile strength and high material heterogeneity, which makes them especially vulnerable against accidental loadings. There are a large number of studies, both experimentally and numerically, of the masonry behaviour under accidental loadings such as earthquakes. In this regard, the most relevant research focuses on (1) evaluating the shear strength of masonry with diagonal compression tests, (2) its behavior against in-plane cyclical loadings and (3) textile reinforced mortars TRM-based reinforcement techniques. However, there are very few studies that analyse the behavior of masonry under high temperature exposure, such as those that can occur in a fire. This paper describes the preliminary results of an experimental tests in which masonry panels (reinforced with TRM and unreinforced) have been tested in diagonal compression, previously damaged by the fire exposure. For this, masonry panels were subjected to different temperature levels, up to a maximum of 600 °C using an electric oven. In general, the results show that high temperatures causes a decrease in shear strength, as well as the transverse stiffness modulus. However, the walls reinforced with TRM based on carbon fiber were the ones that presented the best performance, since their mechanical properties were reduced by a smaller percentage.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Textile Reinforced Mortars (TRM) tensile behavior after high temperature exposure

  • Estevan, Luis
  • Varona Moya, Francisco de Borja
  • Baeza, F. Javier
  • Torres, Benjamín
  • Bru, David
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Bru, David|||/items/00098396-76d2-44fc-8652-746908d86a33
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Torres, Benjamín|||/items/605a19b9-d11e-44d5-b7d8-28a71eaaaa72
  • Varona Moya, Francisco de Borja|||/items/b2f78412-2138-4bd9-a2e5-a9b3e391373e
Although one of the main advantages of Textile Reinforced Mortars (TRM) is their non-combustible character, their behavior against fire or high temperatures has not been sufficiently studied at present. This work analyzes the behavior of different commercial systems containing inorganic mortars and fabric reinforcements based on glass, carbon and basalt fibers, subjected to different temperature levels. To characterize the mechanical response of the different systems, non-destructive tests have been carried out to determine the dynamic modulus of elasticity of the different materials, and subsequent destructive tests to determine their strength and stress-strain relationship. For this purpose, the TRM coupons have been subjected to uniaxial tensile tests and the deformations have been monitored using LVDT (Linear Variable Displacement Transducer) sensors and DIC (Digital Image Correlation), in order to evaluate cracking patterns and failure modes. The results show, in general terms, that the mechanical capacity of these materials is seriously compromised at temperatures in the order of 400 to 600 °C, which can easily be reached during a fire inside a building. Therefore, it can be concluded that although these systems are erroneously perceived as fire resistant in many cases, they may require additional protection depending on the specific use for which they are intended.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Textile reinforced mortars (TRM) for repairing and retrofitting masonry walls subjected to in-plane cyclic loads. An experimental approach

  • Torres, Benjamín
  • Ivorra, Salvador
  • Baeza, F. Javier
  • Estevan, Luis
  • Varona Moya, Francisco de Borja
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
  • Torres, Benjamín|||/items/605a19b9-d11e-44d5-b7d8-28a71eaaaa72
  • Varona Moya, Francisco de Borja|||/items/b2f78412-2138-4bd9-a2e5-a9b3e391373e
Masonry walls exhibit low tensile strength and high material heterogeneity, which makes them especially vulnerable against cyclic loading conditions, such as those typical in earthquakes. This paper presents the experimental results obtained from tests on three masonry walls reinforced with textile reinforced mortar (TRM) materials subjected to in-plane cyclic loading. These full-scale masonry walls were tested in the LARGE laboratory at the University of Alicante (Alicante, Spain). The walls had been built using a traditional construction technique, with solid clay bricks layered with lime mortar. One specimen was tested and damaged by in-plane cyclic loading and was subsequently strengthened by a vertical layer of TRM with an overlapping of 200 mm. It was then tested again until failure in a second test. In addition, another undamaged specimen had been previously reinforced with the same TRM technique and tested until failure, thus providing a third test. A network of sensors and digital image correlation systems were used to monitor displacements and crack patterns. The comparison between these experimental results made it possible to assess the effectiveness of TRM in restoring the structural integrity of damaged masonry walls and almost doubling their load-bearing capacity under cyclic loads. Conclusions obtained here provide valuable information to the scientific community, architects and structural engineers about the strengthening and repair of severely damaged masonry walls.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Masonry walls strengthened with Textile Reinforced Mortars (TRM) and subjected to in-plane cyclic loads after real fire exposure

  • Estevan, Luis
  • Torres, Benjamín
  • Baeza, F. Javier
  • Varona Moya, Francisco de Borja
  • Ivorra, Salvador
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
  • Torres, Benjamín|||/items/605a19b9-d11e-44d5-b7d8-28a71eaaaa72
  • Varona Moya, Francisco de Borja|||/items/b2f78412-2138-4bd9-a2e5-a9b3e391373e
A key feature that determines the seismic performance of masonry buildings is the ability of the walls to withstand in-plane cyclic loads. In this context, Textile Reinforced Mortars (TRM) have proven to be a very suitable strengthening solution, although their effectiveness after high temperature exposure is currently practically unexplored. This paper proposes an experimental campaign with full-scale brick walls and carbon fiber TRM, tested to failure under horizontal cyclic in-plane loads, after being exposed to temperatures of about 1000 °C by exposure to real fire. TRM is applied on one or both sides of the walls, and after or before exposure to fire, to simulate different scenarios that a real building could be exposed to. The results show that high temperatures can seriously compromise the integrity of the walls, while TRM can provide effective protection and prevent cracking of masonry from fire. Even after previous fire damage, the reinforcements can double the shear strength of unreinforced damaged walls, and provide high ductility and energy dissipation capacity. However, it is important to note that TRM, even undamaged, may not be able to properly retrofit a severely fire-damaged wall.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

FRP Confinement of Stone Specimens Subjected to Moisture and Preload

  • Estevan, Luis
  • Baeza, F. Javier
  • Maciá Mateu, Antonio
  • Ivorra, Salvador
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
  • Maciá Mateu, Antonio|||/items/f31a0a33-5d88-40e8-8434-fee7c2688ef8
There are many available studies on the reinforcement of columns by confinement with composite materials. However, in the particular case of stone elements, there is a lack of information regarding the performance of this solution under adverse conditions, which may occur during the life service of the structure. In this research, the confinement of calcarenite samples with a Fiber Reinforced Polymer (FRP) jacket has been studied in different scenarios, which simulate real conditions of structural retrofitting works. Specifically, the FRP’s efficiency was assessed in water saturation specimens, in damaged samples due to previous load, or the FRP jacket was casted directly in preloaded stone columns. As a general conclusion, FRP could improve notably the compressive strength of the unconfined material. In addition, the mechanical behavior seemed to depend on the FRP properties rather than the actual damage suffered by the rock core.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

Numerical Non-Linear Modelling Algorithm Using Radial Kernels on Local Mesh Support

  • Navarro-González, Francisco J.
  • Villacampa, Yolanda
  • Cortés-Molina, Mónica
  • Ivorra, Salvador
  • Cortés-Molina, Mónica|||/items/5846c5ef-c4e7-4af8-996e-e92785f1c1ce
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
  • Navarro-González, Francisco J.|||/items/9f1efaa0-7045-4f34-a1be-870ba61564ab
  • Villacampa, Yolanda|||/items/5d1c4e66-74be-4b8b-924a-7a6795ca96d5
Estimation problems are frequent in several fields such as engineering, economics, and physics, etc. Linear and non-linear regression are powerful techniques based on optimizing an error defined over a dataset. Although they have a strong theoretical background, the need of supposing an analytical expression sometimes makes them impractical. Consequently, a group of other approaches and methodologies are available, from neural networks to random forest, etc. This work presents a new methodology to increase the number of available numerical techniques and corresponds to a natural evolution of the previous algorithms for regression based on finite elements developed by the authors improving the computational behavior and allowing the study of problems with a greater number of points. It possesses an interesting characteristic: Its direct and clear geometrical meaning. The modelling problem is presented from the point of view of the statistical analysis of the data noise considered as a random field. The goodness of fit of the generated models has been tested and compared with some other methodologies validating the results with some experimental campaigns obtained from bibliography in the engineering field, showing good approximation. In addition, a small variation on the data estimation algorithm allows studying overfitting in a model, that it is a problematic fact when numerical methods are used to model experimental values.
RUA. Repositorio Institucional de la Universidad de Alicante
Publicación Otros (Other)

TRM (Textile Reinforced Mortars) sometidos a temperaturas elevadas: análisis de la adherencia sobre muros de ladrillo

  • Estevan, Luis
  • Baeza, F. Javier
  • Ivorra, Salvador
  • Baeza, F. Javier|||/items/e40f041d-5b10-47fa-abd4-dd4fb5f526b6
  • Estevan, Luis|||/items/5f18efe7-6bb3-4f03-8105-197f6c652db1
  • Ivorra, Salvador|||/items/f458a5ac-f699-440d-ad8a-ca0b6fec91bd
Uno de los aspectos más importantes que determina la eficacia de los Textile Reinforced Mortars (TRM) es su capacidad de adherencia respecto del sustrato base, cuestión esencial para garantizar una correcta transmisión de tensiones. Aunque este tema ha sido objeto de diferentes investigaciones durante la última década, la adherencia bajo el efecto de temperaturas elevadas apenas ha sido analizada hasta la fecha. En este trabajo se plantea el estudio experimental de la adherencia entre muros de ladrillo cerámico y distintas soluciones de TRM, con mallas de fibras de carbono o vidrio y diferentes matrices. Los ensayos se realizan a temperatura ambiente y tras exposición a 200 y 400 ºC, a fin de evaluar la incidencia que un eventual incendio podría tener en un edificio reforzado con estos materiales. Los resultados muestran, en líneas generales, que la exposición a temperaturas elevadas reduce notablemente la adherencia y puede comprometer seriamente la eficacia de estos refuerzos. Puede concluirse, por tanto, que aunque los TRM se perciben con frecuencia como sistemas resistentes al fuego y que pueden emplearse sin protección, en realidad no es así.